Product type

Industrial Data Loggers

An industrial data logger records measurements over time, unattended, in a place where nobody is standing. Its distinguishing feature is not the recording but the conditions: it is expected to run for weeks or months without attention, in a panel, on a wall or on a machine, and to hold its data until someone retrieves it.

What an industrial data logger is

An industrial data logger records measurements over time, unattended, in a place where nobody is standing. Its distinguishing feature is not the recording but the conditions: it is expected to run for weeks or months without attention, in a panel, on a wall or on a machine, and to hold its data until someone retrieves it.

What makes it industrial is the combination of the enclosure, the input range and the power arrangement. The inputs have to accept the signals actually present - a process current or voltage, a resistance thermometer, a thermocouple, a pulse from a meter - without a separate conditioner for each one. The enclosure has to suit where it is mounted. The power has to come from what is available, which on a remote site may be a small solar panel and a battery, and in a cabinet may be a supply.

The retrieval route is the decision most often left until last, and it is the one that determines whether the data is ever used. A logger whose data has to be collected by hand is a logger that is visited rarely; one that reports over a network is read continuously and can raise an alarm. This page covers that choice, the input and power decisions, and the boundary against the neighbouring acquisition and monitoring devices.

How an industrial data logger measures

A logger reads each channel on a defined interval, converts it to an engineering value, and writes it to memory with a timestamp. The interval and the channel count together determine how much memory is consumed, and that arithmetic decides whether it can run unattended for the intended period. Recording every second across many channels fills memory quickly; recording every fifteen minutes on a few channels may last for years.

Isolation and input range matter more in the field than on a bench. Signals arriving from a plant may sit on a different ground potential from the logger, and a channel that is not isolated can carry that difference into the instrument. A channel that accepts a wide input range directly avoids the fault-prone combination of a separate conditioner per sensor, though it brings its own decisions about resolution and accuracy at the range in use.

Unattended operation puts the emphasis on what happens when something goes wrong. A logger with no alarm output records a fault and is discovered later; one with alarm contacts, or one that reports over a network, can raise a warning while the event is still actionable. That distinction usually matters more to the value of the installation than the accuracy specification does.

Configuration choices

Most of the specification is fixed by these decisions rather than by the accuracy class. Each one constrains the next, which is why they are settled in order.

ConfigurationOptions to fixWhat it actually decides
Input channel count and type Universal channels that accept several signal types, or dedicated channels per signalWhether the existing sensors connect directly, and whether one instrument can serve a mixed set of measurements.
Recording interval From sub-second to hourlyHow much memory the intended period consumes, and whether short events are captured or averaged away.
Storage Internal memory, removable media, or bothWhether the record survives, and whether the data can be carried away without a computer at the site.
Communication and retrieval A wired connection, an RS-485 bus, Ethernet, wireless, or a cellular linkWhether the data can be read remotely or has to be collected by hand, which decides how often anyone looks at it at all.
Power source Mains supply, an internal battery, an external battery pack, or a solar arrangementHow long the installation runs unattended, and whether a power failure ends the record.
Enclosure and protection The ingress protection, and whether the enclosure is for a panel or for outdoor mountingWhere the logger can be installed, and whether an additional enclosure is needed.
Alarm and control outputs Digital outputs, relay contacts, or alarm messages sent over the networkWhether the installation can act on a limit breach, or only record it.
Time reference and synchronisation How the clock is set, and whether it synchronises over a networkWhether readings from several loggers can be compared, which they cannot be once their clocks have drifted apart.

How to choose an industrial data logger

FactorWhy it decides the answerHow to settle it before enquiring
What is being measured, and the signal each sensor gives The signal type decides the channels, and the count decides the instrumentList the sensors, with the signal each produces and the range of each.
Recording interval and duration Together with the channel count, these fix the memory requirementState the interval, the number of channels, and the period the record has to cover.
Whether the data must be retrieved remotely This is what decides between a simple logger and a communicating oneState whether anyone can visit the site, and how often.
Power available at the site Mains, battery or solar, and the temperature the battery will seeDescribe the supply, and the ambient conditions the installation will face.
Where it will be mounted A panel, a wall, a machine or an outdoor positionState the location, so that the enclosure and the temperature range follow from it.
Whether a limit breach must act Recording and alarming are separate capabilitiesSay whether the installation has to raise an alarm, or only keep a record.
Whether readings must align with other systems Comparing data from several devices requires a common time referenceState whether results are combined with other records, and how the clocks are kept together.

If any of these are still open, send what is known. A quotation can be issued against a duty description and refined once the gaps are filled.

The nearest alternatives

These are the types an enquiry for an industrial data logger usually turns out to be, and the point at which the choice is genuinely decided.

Nearest alternativeWhat separates it from an industrial data logger
Data acquisition systems Built for many channels at high speed, usually attached to a computer that captures and processes the data in real time. They suit laboratory and test-bench work where a large amount of data is taken in a short period; a logger suits a small number of channels observed over a long one.
Data loggers The general form of the same instrument, without the emphasis on surviving an industrial location. The distinction is the enclosure, the input range and the temperature rating rather than the recording function, which is common to both.
Temperature data loggers Dedicated to temperature, and often to a specific sensor type, which lets them be small, inexpensive and long-running. They are the right answer where temperature is the only measurement, and they have nothing to offer once a second quantity has to be recorded.
Humidity data loggers Dedicated to humidity, and usually to the temperature that accompanies it, since the two are measured together in most methods. They suit storage, transport and clean-room records, which is a narrower duty than a general industrial logger covers.
Wireless data loggers Use a radio or mesh network to relay readings, which removes the cost of cabling across a large site. The trade is in the power budget and in the reliability of the radio path, both of which have to be established before the installation is planned.
Monitoring software The layer above the logger: it stores readings, presents trends and raises alarms. A logger can run without it, but data that is never put in front of anyone is data that is never acted on, which is usually the point of the installation.

The retrieval route is the decision that determines whether the data is used. A logger whose readings have to be collected by hand tends to be visited rarely, whatever its specification says about accuracy.

What to include in the enquiry

The first reply can be a quotation rather than a set of questions if the enquiry carries these. Where a figure is not known, send the duty description and we will confirm what it implies.

  1. The sensors to be connected, with the signal each produces
  2. Number of channels, and whether the signal types are mixed
  3. Recording interval, and the period the record must cover
  4. Whether the data has to be retrieved remotely, and by what means
  5. Power available, and whether the installation has to survive a supply failure
  6. Where the logger will be mounted, indoors or outdoors
  7. Whether a limit breach has to raise an alarm or operate a contact
  8. Whether readings must be aligned with other records on site
  9. Quantity, destination port and required delivery date

Available products

1 model in Industrial Data Loggers

Black panel-mount paperless recorder shown at an angle, with a colour screen displaying six channels as coloured numeric values in two columns with units beside each reading, a column of round keys and a USB socket to the right of the screen, and louvres moulded into the side of the case

MIK-R200T (4 models) · Industrial Data Loggers

Paperless Data Recorder

Panel-mount paperless recorders in four model ranges, from 6 to 48 input channels, accepting current, voltage, resistance thermometer and thermocouple signals directly and storing the record in internal flash memory.

Model ranges
MIK-R200T, MIK-R5000C, MIK-R6000C and MIK-RN3000
Input channels
1 to 6 on MIK-R200T, 1 to 12 on MIK-R5000C, 1 to 48 on MIK-R6000C, 1 to 18 on MIK-RN3000
Sampling period
1 s, one sample per channel every second
Input types
Current, millivolt, voltage, resistance thermometer, thermocouple and linear resistance, by model

Also in Data Acquisition & Monitoring

Other product types in this category

Every type we quote for under Data Acquisition & Monitoring. A type with no link yet is still quoted for - it is described on the Data Acquisition & Monitoring overview, and gets a page of its own as soon as a model is published against it.

Frequently asked

Industrial Data Loggers questions

Logger or data acquisition system?

It depends on how much data is taken and over how long. An acquisition system takes many channels quickly and passes them to a computer, which suits a test lasting minutes or hours. A logger takes a few channels slowly and keeps the data on board, which suits an installation observed for months. The two overlap in the middle, and the deciding questions are the channel count, the speed, and whether a computer is present.

How long can it run on a battery?

That follows from the recording interval, the number of channels and how the data is retrieved, because each of those consumes energy. Lengthening the interval often costs nothing that matters and extends the life more than a larger battery does. Where the answer has to be a specific period, it is normally established against the actual channel list rather than assumed from a catalogue figure.

How is the data retrieved?

Either by collecting the instrument or its memory card, or over a network. The choice matters more than it appears: a logger that has to be visited is read at the interval somebody is willing to travel, which on a remote site may be months. A communicating logger can be read continuously and can raise an alarm while the event still matters. If the data is meant to inform a decision, the retrieval route has to be settled first.

Can it read a 4-20 mA signal directly?

Channels that accept standard process signals do so without a separate conditioner, which is one of the practical reasons to choose an industrial logger over a general-purpose one. The channel still has to be set to the right range and scaling, and the input has to be isolated where the sensor and the logger sit on different ground potentials. Both are worth confirming against the actual sensor list.

Quoting for Industrial Data Loggers

Send the specification and we will confirm the matching model, availability and lead time. Minimum order quantity is 1 pc.

Request for quotation

Request a quotation - Industrial Data Loggers

Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.

The more of this you can give us, the fewer exchanges are needed before we can quote.
No file chosen
Datasheet, drawing, BOM or photograph. One file, up to 10 MB (PDF, Office, image or ZIP).

By submitting this form you agree that we may contact you about this enquiry. We do not sell or share enquiry data. See our privacy policy.

Items held in stock are dispatched within 48 hours of order confirmation. Customized specifications are produced to order and typically ship within 2 to 10 days. Transit time then depends on the shipping method and destination.

Request a Quote WhatsApp