Products

Industrial instrumentation & measurement products

The portfolio covers flow, pressure, temperature, level and process analysis; electrical and mechanical test; non-destructive and dimensional inspection; laboratory and calibration equipment; industrial sensors, automation hardware and data acquisition. Products are organised by measurement function and by the engineering problem they solve, so a requirement can be followed from the physical property being measured down to a specific instrument type.

Eighteen categories sit on this page, and each one is a hub: what the category covers, which technologies belong to it, how those technologies differ, what to fix before ordering and what to include in an enquiry. 18 categories hold published products with full specifications today. The remainder are open for quotation against your specification, which is why a category can be listed here without a model on it yet.

Measurement & Process Instrumentation

Field instruments that turn a physical property of the process into a readable value: flow, pressure, temperature, level and the indicators, transmitters and valves that carry that value to the control room.

01 · AVAILABLE

Flow Measurement

Volumetric and mass flow meters for liquids, gases and steam, from clamp-on ultrasonic to sanitary electromagnetic designs.

14 product types: Electromagnetic Flow Meters · Ultrasonic Flow Meters · Vortex Flow Meters · Coriolis Mass Flow Meters · Turbine Flow Meters · Thermal Mass Flow Meters · Positive Displacement Flow Meters · Variable Area Flow Meters · Oval Gear Flow Meters · Open Channel Flow Meters · Flow Switches · Flow Controllers · Flow Indicators · Flow Totalizers

Open the flow measurement hub →
02 · AVAILABLE

Pressure Measurement

Gauges, transmitters and switches covering vacuum through to high-pressure service, including differential, absolute and hygienic designs.

16 product types: Pressure Gauges · Digital Pressure Gauges · Differential Pressure Gauges · Vacuum Gauges · Compound Pressure Gauges · Pressure Transmitters · Differential Pressure Transmitters · Absolute Pressure Transmitters · Pressure Transducers · Pressure Switches · Differential Pressure Switches · Vacuum Pressure Switches · Pressure Controllers · Diaphragm Seals · Pressure Manifolds · Pressure Accessories

Open the pressure measurement hub →
03 · AVAILABLE

Temperature Measurement

Thermocouples, RTDs, transmitters, infrared thermometers and controllers for contact and non-contact temperature work.

18 product types: Thermocouples · Type K Thermocouples · Type J Thermocouples · Type T Thermocouples · Type E Thermocouples · Type N Thermocouples · Type R Thermocouples · Type S Thermocouples · Type B Thermocouples · RTD Temperature Sensors · Resistance Temperature Detectors · Temperature Transmitters · Temperature Switches · Digital Thermometers · Infrared Thermometers · Temperature Indicators · Temperature Recorders · Temperature Controllers

Open the temperature measurement hub →
04 · AVAILABLE

Level Measurement

Continuous and point level instruments - radar, ultrasonic, hydrostatic, capacitance and float - for tanks, silos and interfaces.

15 product types: Radar Level Meters · Radar Level Transmitters · Ultrasonic Level Meters · Ultrasonic Level Transmitters · Hydrostatic Level Transmitters · Capacitive Level Sensors · Magnetostrictive Level Sensors · Float Level Sensors · Magnetic Level Gauges · Level Indicators · Level Switches · Vibrating Fork Level Switches · Rotary Paddle Level Switches · Capacitive Level Switches · Conductive Level Switches

Open the level measurement hub →
05 · AVAILABLE

Process Instrumentation

Panel indicators, controllers, transmitters, control valves and positioners - the single-instrument layer between the sensor and the control system.

10 product types: Process Indicators · Process Controllers · Process Transmitters · Signal Indicators · Panel Meters · Process Switches · Control Valves · Valve Positioners · Valve Accessories · Instrument Accessories

Open the process instrumentation hub →
White-bodied flow meter with a red transmitter housing, an integral display reading 13.625 m³/h and a running total, three buttons marked ESC, ENT and a direction key below the display, two cable glands on the side, and a red flow-direction arrow moulded on the white measuring section between two flanges

LDG-SUP · Electromagnetic Flow Meters

Intelligent Electromagnetic Flow Meter

A direct-display electromagnetic flow meter for conductive liquids, from DN10 to DN2000, with the liner and electrode selected against the medium and its temperature.

Model
LDG-SUP
Media
Conductive liquids at ≥50 µS/cm, including water, wastewater, coolant, paper stock and acid or alkali solutions; ≥2 µS/cm for the liquid-cooling form and ≥5 µS/cm for the slurry form
Nominal size
DN10 to DN2000 standard, DN6 to DN65 micro-bore, DN300 to DN2200 to order
Accuracy
±0.5 % of reading
Flow meter head with a blue casing, a dark liquid-crystal display and three buttons beneath it, carried on a stainless steel stem above a flanged pipe body with a large flange at each end, a separate armoured temperature probe on a flexible conduit beside it, and a small red flow-direction label on the body

LUGB-SUP (2 models) · Vortex Flow Meters

Vortex Steam Flow Meter

A vortex flow meter for steam, gas and liquid lines, supplied in an integral and a conventional form with pulse, current or serial output and optional temperature and pressure compensation.

Model
LUGB-SUP / LUGB-SUP-C
Media
Liquid, gas and steam, including saturated and superheated steam
Nominal size
DN15 to DN300 as a full-bore body; DN300 to DN1000 as an insertion type
Accuracy
1.0 % to 2.5 % of reading, according to medium, size and compensation
Wall-mounted flow meter in a light grey enclosure with a green backlit display showing zero flow, a printed label reading ULTRASONIC FLOWMETER above it, a numeric keypad marked 0 to 9 with menu and enter keys below, five cable glands along the bottom edge, and a pair of clamp-on transducers in blue and white housings lying beside it

SIN-1158S (3 models) · Ultrasonic Flow Meters

Clamp-On Ultrasonic Flow Meter

Clamp-on ultrasonic flow meter for heating, building and process water, supplied as a wall-mounted, handheld or fixed host with clamp-on and insertion transducers.

Model
SIN-1158S / SIN-2100H / SIN-FSC400
Mounting
Clamp-on transducers on the outside of the pipe, or an insertion transducer through the wall
Accuracy
±1 % of full scale, as stated in the material
Pipe range
DN20 to DN1200 according to host and transducer; DN80 to DN6000 with an insertion probe
Blue differential pressure transmitter with a stainless 316 twin-chamber body, six flange bolts, and an LCD reading 4.000 mA

Differential Pressure Transmitters

Differential Pressure Transmitter

A differential pressure transmitter from 0-1 kPa to 0-10 MPa, with 0.075 to 0.5 class accuracy, 4-20 mA with HART or RS-485, single and double flange forms, and 316L, Hastelloy or tantalum diaphragms.

Range
0-1 kPa to 0-10 MPa, with 0-3000 Pa, 0-30 kPa and 0-100 kPa as the low spans
Accuracy
0.075, 0.1, 0.2 or 0.5 class depending on the form
Output
4-20 mA with HART, or RS-485; 0-10 V on the micro-differential form
Supply
24 V DC as standard, 9-32 V DC on the transmitter shown
Stainless steel digital pressure gauge with a blue bezel, a four-digit LCD reading 10.000 MPa, and ON/OFF, SET and RESET keys

Digital Pressure Gauges

Digital Pressure Gauge

A battery or 24 V DC digital pressure gauge from 100 kPa to 100 MPa, with a four-digit display, six switchable units and a 304 stainless case for water, air, hydraulic and oil service.

Range
100 kPa to 100 MPa across the range, with 0-0.6, 0-1, 0-1.6, 0-2.5, 0-40, 0-60 and 0-100 MPa as the common spans
Accuracy
0.2, 0.4 or 0.5 class depending on the form
Display
Four digits with up to three decimal places, six switchable units and a backlight
Process connection
M20 x 1.5 as standard, with NPT 1/4 and G1/2 to order
Three stainless steel pressure transmitters side by side, one with a plug connector, one with a plug and tubular body, and one with a circular connector and cable gland

MIK-P300 · Pressure Transmitters

Configurable Pressure Transmitter

Diffusion silicon pressure transmitters built in a family of housings, from a plain plug version to sanitary, high-temperature, explosion-proof and 4G wireless forms, with 4-20 mA, voltage or RS-485 Modbus output.

Pressure ranges
-100 kPa to 60 MPa across the series
Pressure types
Gauge, absolute and sealed gauge
Accuracy
0.2, 0.25 or 0.5 grade, by range and configuration
Output
4-20 mA two-wire; 0-5 V, 1-5 V or 0-10 V three-wire; RS-485 with Modbus
Rectangular pressure switch with a transparent scale window showing RANGE and DIFF marks, two adjustment screws, a metal threaded pressure port and a circular push-in fitting on the side

PK503 (3 models) · Pressure Switches

Mechanical Pressure Switch

Mechanical pressure switches with a separate set point and differential screw, SPDT contacts and automatic reset, covering vacuum down to -0.05 MPa and positive pressure to 1.0 MPa in three range versions.

Ranges
PK503 -0.05 to 0.3 MPa; PK506 -0.05 to 0.6 MPa; PK510 0.1 to 1.0 MPa
Adjustable differential
0.035 to 0.15 MPa; 0.06 to 0.4 MPa; 0.1 to 0.3 MPa respectively
Contact form
SPDT, single pole double throw, terminals 1-3-5
Reset
Automatic
Black cased circular pressure gauge with a white dial graduated to 1.6 MPa, a red tipped pointer and a brass threaded connection below the case

Y-60 (2 models) · Pressure Gauges

Bourdon Tube Pressure Gauge

Bourdon tube pressure gauges in 60 mm and 100 mm dial sizes with brass connections, covering vacuum to 40 MPa on the 60 mm dial and offered across a wide range list on the 100 mm dial, in iron and stainless steel cases.

Dial sizes
60 mm (Y-60) and 100 mm (Y-100); a 150 mm size is named without a parameter table
Accuracy class
2.5 class on the 60 mm dial; 1.6 class on the 100 mm dial
Range, 60 mm dial
0-0.1 MPa up to 0-40 MPa in fourteen steps, plus -0.1-0 MPa vacuum
Range, 100 mm dial
0-0.1 MPa up to 0-60 MPa listed for the series, with compound and vacuum forms
Clamp-on thermocouple with a threaded stainless steel head, a braided stainless steel lead and fork terminals with red and blue sleeves

Thermocouples

Clamp-On Thermocouple

Spring-clamp thermocouple with a stainless steel M12×1.5 threaded head and a braided high-temperature shielded lead, for moulds, extruders, heating bands and other points that need a probe pressed into place.

Calibration types
K and E thermocouple, plus a PT100 resistance variant in the same body
Measuring range
K 0 to 800°C; E 0 to 400°C; PT100 -200 to 450°C
Thread
M12×1.5, removable
Probe front
5 mm tube outside diameter, 10 mm protruding
Two NTC thermistor probes with stainless steel sensing tips and coiled lead wires, one with a black cable and one with a grey cable

Resistance Temperature Detectors

NTC Thermistor Temperature Probe

Stainless steel NTC thermistor probe with a 10 kΩ element at 25°C and a 3950 K B value, supplied with lead wires and plug terminals for control boards and acquisition modules.

Resistance at 25°C
10 kΩ, ±1%
B constant B25/50
3950 K, ±1%
Thermal time constant
3 s, measured in stirred water from 25 to 50°C
Operating temperature
-30 to 180°C in the parameter table; -20 to 105°C on the main image
Two sheathed temperature probes with metal braided leads and fork terminals, one with two conductors and one with three

Temperature Transmitters

Temperature Transmitter Module

Two-wire temperature transmitter module for RTD and thermocouple inputs, converting the sensor signal to 4-20 mA or 0-10 V from 24 VDC, with 0.2%FS accuracy and zero and span potentiometers.

Input
RTD: Pt100, Cu50, Cu100, Pt1000; thermocouple: B, E, J, K, N, R, S, T, WRe3-25, WRe5-26
Sensor range covered
-200 to 1800°C across the range of input types
Output
Two-wire 4-20 mA as standard; a 0-10 V version is listed separately
Accuracy
0.2%FS
Wide benchtop temperature scanner with a 5 in colour screen showing sixteen channel readings in four columns, two USB sockets at the left, a power switch below them and a keypad with a round OK button at the right

HG-8 (2 models) · Temperature Recorders

Multi-Point Temperature Scanner and Recorder

Eight or sixteen channel thermocouple scanner with a 5 in touchscreen, a scan interval from one second to a day, live-circuit rating and MODBUS RTU communication.

Channels
8 on the HG-8, 16 on the HG-16
Thermocouple types
K, T, J, E, S, N, B and P
Range
−200 to 1350 °C
Accuracy
±0.5% ±0.6 °C
Benchtop temperature recorder with a 5 in colour screen showing eight channel readings in two rows above a row of file and view keys, a USB socket at the left and a keypad with a round Enter button at the right

LK1008S (4 models) · Temperature Recorders

64-Channel Temperature Recorder

Temperature recorder built from 8 to 64 channels, with 8 GB flash memory that holds data through a power cut, four-level alarms and a choice of a 5 in keyed or 7 in touch panel.

Channels
8, 16, 24, 32, 40, 48, 56 or 64
Accuracy
0.2% ±2 digits, thermocouple excluded; the model cards state 0.2% + 0.5 °C
Display range
−999.9 to 1999.9
Probes
Type K supplied; S, R, N, E, J, T, B, PT100, PT1000 and Cu50 by type
Benchtop temperature recorder seen from the front, with a colour screen showing eight channels of readings in two rows, a USB socket at the left, a round power button below it and a speaker grille at the right

TCP-400 (4 models) · Temperature Recorders

Multi-Channel Temperature Recorder and Scanner

Benchtop multi-channel temperature recorder for 8 to 64 thermocouple inputs, with a colour touchscreen, per-channel correction, four-level alarms and USB logging.

Channels
8 to 64, added in blocks of eight
Thermocouple types
K, S, R, B, N, E, J, T; W5/26 on the XL, 500 and 700 series
Display accuracy
0.2% + 0.5 °C ±2 digits, thermocouple not included
Temperature range
−270 to 2310 °C as marked on most units; a second listing gives −200 to 1300 °C
Benchtop recorder with a wide colour screen showing a multi-channel trend plot and a row of page tabs, a USB socket at the left, a round power button beneath it and a vent grille on the right of the front panel

YP4000 (3 models) · Temperature Recorders

Paperless Multi-Channel Temperature Recorder

Touchscreen temperature recorder for 8 to 64 isolated inputs, with four-level alarms, internal storage that survives power loss and wireless viewing from a PC or phone.

Channels
8 to 64, by series
Scan interval
0.1 to 9999 s, adjustable, with three preset speeds
Accuracy
±0.2% ±2 digits, thermocouple excluded
Range
−200 to 1800 °C, sensor dependent
Radar level meter with a blue cap over a stainless cylindrical housing carrying two cable entries and a cover screw, a black nameplate on the body, and a large stainless flange at the base drilled for bolts with a raised sealing face in the centre

MIK-RD908 (3 models) · Radar Level Meters

80 GHz Radar Level Meter

Radar level meter in 80 GHz, low-frequency and guided-wave series for tanks, silos, rivers and pressurised vessels, with spans from 10 m to 80 m.

Model
Fourteen models across three series, from MIK-RD908 to MIK-RD702
Series
80 GHz high-frequency, low-frequency, and guided-wave
Range
0 to 10 m through to 0 to 80 m, according to series and model
Accuracy
±5 mm on the shortest spans through to ±30 mm at a 70 m span
Stainless steel vibrating fork level switch with a ribbed heat-break section, G1/2 thread, two fork tines and a SET key on the housing

QDY30A-SX · Vibrating Fork Level Switches

Vibrating Fork Level Switch

A vibrating fork level switch for point level in tanks and pipes, rated to 2 MPa with a fork temperature of -30 to 150 °C, in relay, transistor or CAN output and 24 V DC or 220 V AC supply.

Model
QDY30A-SX
Pressure rating
2 MPa
Fork temperature
-30 to 150 °C, with higher temperatures to order
Ambient temperature
-20 to 70 °C at the housing
Integrated ultrasonic level meter standing upright with a translucent red top section, a grey threaded ring below it, a white body carrying two screened circular fittings on the front and the letters DC moulded beneath them, and a black lower section ending in the transducer face

SIN-MP-C (4 models) · Ultrasonic Level Meters

Ultrasonic Level Meter

Non-contact ultrasonic level meter for tanks, sumps, channels and silos, in integral and separate forms, with 4-20 mA and RS-485 outputs and a relay pair.

Model
SIN-MP-C / SIN-ULS-B / SIN-WSU100 / WSU200
Mounting
Non-contact, above the medium
Forms
Integral, with the transducer in the head, or separate, with the head and probe mounted apart
Range
0 to 1 m through to 0 to 15 m across the forms
Stainless steel cylindrical probe with a black end cap carrying a central pressure port and a ring of four smaller ports around it, joined to a coiled length of black cable with two bare conductors emerging at the far end

XK-136P · Hydrostatic Level Transmitters

Submersible Level Transmitter

Submersible hydrostatic level transmitter for water tanks, sumps, reservoirs and pits, from 1 m to 10 m as standard, with a probe rated IP68.

Model
XK-136P
Type
Submersible hydrostatic level transmitter with a vented cable
Range
0 to 1 m, 0 to 3 m, 0 to 5 m and 0 to 10 m as standard, to 500 m to order
Accuracy
0.5 class, with 0.2 class to order
A rectangular panel meter with a black bezel, showing a two-hundred-and-thirty volt reading in red digits and a current reading in blue digits, with a small split-core current transformer on a lead below it

AC-10A (3 models) · Panel Meters

Digital AC Panel Meter

Panel meter showing AC voltage and current together on two rows of digits, self-powered from the measured circuit and supplied with a split-core current transformer.

Voltage range
AC 60 to 500 V, for 220 V single-phase and 380 V three-phase circuits
Current ranges
10 A, 50 A and 100 A versions, the 10 A version resolving to 0.01 A
Supply
No separate supply; the measured voltage powers the instrument
Display
Two rows of digits, voltage in red and current in blue, with AC symbols on the right

Analysis & Monitoring

Instruments that answer not how much but what: composition, water and gas chemistry, laboratory analysis, and the monitoring networks that watch emissions and ambient conditions over time.

06 · AVAILABLE

Process Analysis

Online and in-line analysers for water chemistry, gas composition and moisture - built for continuous duty in the process, not the laboratory.

15 product types: pH Analyzers · Process pH Meters · ORP Analyzers · Conductivity Analyzers · Process Conductivity Meters · Dissolved Oxygen Analyzers · Turbidity Analyzers · Chlorine Analyzers · TDS Meters · Salinity Meters · Water Quality Analyzers · Gas Analyzers · Oxygen Analyzers · Moisture Analyzers · CO2 Analyzers

Open the process analysis hub →
08 · AVAILABLE

Environmental Monitoring

Air quality and dust monitors, particle counters, VOC detectors, noise and light meters, weather stations and data loggers.

12 product types: Air Quality Monitors · Dust Monitors · Particle Counters · VOC Detectors · Noise Meters · Light Meters · Weather Stations · Temperature & Humidity Data Loggers · Radiation Monitoring Equipment · Water Quality Monitoring Equipment · Environmental Data Loggers · Environmental Monitoring Systems

Open the environmental monitoring hub →
09 · AVAILABLE

Gas Detection & Safety Instruments

Portable and fixed gas detectors, toxic and combustible gas sensors, leak detectors and flame detection systems.

11 product types: Portable Gas Detectors · Fixed Gas Detectors · Multi-Gas Detectors · Single-Gas Detectors · Gas Leak Detectors · Combustible Gas Detectors · Toxic Gas Detectors · Oxygen Gas Detectors · Gas Detection Systems · Flame Detectors · Industrial Safety Instruments

Open the gas detection & safety instruments hub →
A panel-mount controller in a black enclosure with a colour graphic display, showing a live measurement with a temperature and a current output value, six keys along the lower edge and two indicator lamps

FK-EC480 (11 models) · Conductivity Analyzers

Online Conductivity Analyzer

Panel-mount online conductivity analyzer covering ultrapure water to brine, with automatic or manual temperature compensation, isolated current outputs, relays and a serial port, and a choice of contact or inductive electrodes.

Range
Set by the electrode cell constant: about 0 to 20 microsiemens per centimetre at a constant of 0.01, up to 0 to 600 millisiemens per centimetre on the high specification controller
Accuracy
Stated as 2.0 class on the flagship and high specification controllers and as 1.5 percent of full scale on the compact controller
Temperature
minus 10.0 to 130.0 degrees Celsius, with automatic or manual compensation
Temperature elements
NTC10K, Pt1000, NTC30K or Pt100 depending on the controller, matched to the element fitted in the electrode
White pen-shaped water quality tester with a small dark display showing a reading and a score, two round keys beneath it and a marked water line near the lower end

LS310 (2 models) · Water Quality Analyzers

Multi-Parameter Water Quality Tester

Pen-type water quality tester reading COD, TOC, UV275, TDS, conductivity and temperature in one immersion, with a four-colour score display and an IP67 probe.

Parameters
COD, TOC, UV275, TDS, conductivity and temperature; LS311 adds salinity, hardness and specific gravity
Measuring range
COD 0 to 100 mg/L; TOC 0 to 100 mg/L; UV275 0 to 1.0 au/cm; TDS 0 to 2000 ppm; conductivity 0 to 4000 µS/cm; temperature 0 to 50 °C
Resolution
COD and TOC 0.01 mg/L; UV275 0.001 au/cm; TDS 1 ppm; conductivity 1 µS/cm; temperature 0.1 °C
Accuracy
COD and TOC ±0.5 mg/L below 5 mg/L and ±10% H above; TDS and conductivity ±3% FS; temperature ±1 °C
Panel-mount process controller with a red front panel over a pale blue liquid crystal display reading 3.76 pH, five black buttons along the lower edge, and a glass electrode with a pale blue bulb lying below the case

MIK-pH8.5 (3 models) · pH Analyzers

Online pH/ORP Controller

Panel-mount pH and ORP controllers in three tiers, from a 4.3 inch display with two isolated current outputs and three alarm contacts down to a 96 x 96 mm case with one output, all reading pH to ±0.02 from a single glass or antimony electrode.

Tiers and displays
4.3 inch display on the flagship; 2.8 inch on the upgrade and economy tiers
Case size
151 x 144 x 118 mm flagship; 100 x 100 x 150 mm upgrade; 96 x 96 x 112 mm economy
pH range
-(2.00~16.00) pH on the flagship, with antimony electrode support; 0~14 pH on the upgrade and economy tiers
ORP range
±2000 mV on the flagship; -1000~+1000 mV on the economy tier; -1000~+1000 mV on the upgrade tier with ±2000 mV made to order
A panel-mount dissolved oxygen analyzer with a black bezel and a backlit liquid crystal display showing an output setup screen, with four keys beneath the screen, alongside a stainless-steel electrode with a threaded mounting body and a cable

OHR-DO10 (2 models) · Dissolved Oxygen Analyzers

Online Dissolved Oxygen Analyzer

Online dissolved oxygen analyzer for continuous water monitoring, with a membrane or an optical electrode, temperature, salinity and pressure compensation, two alarm relays, an analogue output and a serial port.

Measurement range, membrane controller
0 to 200 percent saturation and 0 to 20.00 mg/L or ppm, with a temperature channel from 0.0 to 65.0 degrees Celsius
Measurement range, optical controller
0 to 20.00 mg/L or ppm, with the saturation range carried as a reserved parameter; electrode temperature 0 to 60 degrees Celsius
Accuracy
plus or minus 1.5 percent of full scale on the membrane controller; plus or minus 0.5 mg/L on the optical controller; temperature to plus or minus 0.5 degrees Celsius
Compensation
Temperature automatically by a sensing element in the electrode or manually; salinity entered manually; pressure entered manually
White benchtop spectrophotometer with a rounded body, a red sample compartment lid set into the top, a sloped keypad panel carrying a small blue display at the right, and lettering printed along the lower front face above a black knob

LC-V1200E (9 models) · Spectrophotometers

UV-Vis Spectrophotometer

Benchtop single beam and double beam spectrophotometers in nine models, spanning the visible range on tungsten lamps and the ultraviolet and visible range on tungsten plus xenon, with bandwidths from 5 nm down to 1.8 nm.

Series
V series for the visible range on a tungsten lamp; UV series for the ultraviolet and visible range on tungsten plus xenon
Models
Nine model codes across the two series, from LC-V1200E to LC-UV1800
Wavelength range
350-1050 nm on LC-V1200E; 320-1100 nm on the other visible models; 190-1100 nm on every UV model
Spectral bandwidth
5 nm, 4 nm, 2 nm and 1.8 nm, by model
Pocket film tester in a white front plate and dark grey case, with a backlit display listing VLT, UVR and IRR above percentage bars, a single round key to the left and three small labels beside the screen

LS160 (6 models) · Spectrophotometers

Solar Film Transmittance Meter

Pocket solar film tester that reports visible transmission, ultraviolet rejection and infrared rejection together when a sample is placed in its slot, at either 940 or 1400 nm.

Measured quantities
VLT visible light transmission; UVR ultraviolet rejection; IRR infrared rejection
Peak wavelengths
Visible 530 nm; ultraviolet 365 nm; infrared 940 nm on LS160, LS162 and LS163, 1400 nm on the A versions
Sample thickness
Below 0.8 mm on the film models; 20 mm on LS101 and 47 mm on LS182
Resolution
0.1%
A hand-held colorimeter standing upright in a white housing, with a measurement aperture at the base and an alignment triangle below it, a round control on the top face, and a printed label carrying a model designation, a reference number and a square code

LS170 (7 models) · Colorimeters

Portable Colorimeter

Handheld colorimeter that reads the colour of a surface and reports its difference from a stored standard, with a choice of measurement geometry, a colour library held on the instrument and a tolerance that returns a pass or fail.

Measurement time
About 1 second per reading
Illumination
Full-spectrum LED source, evaluated at illuminant D65 with a 10 degree observer
Measurement geometry
45/0 on the LS170, LS172, LS175 and LS372; D/8 with the specular component included on the LS171, LS173 and LS176
Measurement aperture
8 mm on the LS170, LS171, LS172, LS173 and LS176; 20 mm on the LS175; 4 mm on the LS372
Square indoor air quality monitor with a black face, showing the time at the top, a semicircular index dial reading 047 between the good and bad ends of the scale, temperature and humidity beside it, and six pollutant rows beneath covering formaldehyde, total volatile organic compounds, benzene, carbon dioxide and the two particle fractions

Air Quality Monitors

Multi-Parameter Air Quality Monitor

Indoor air quality monitor reading formaldehyde, total volatile organic compounds, benzene, carbon dioxide, PM2.5, PM10 and a combined index with temperature, humidity, WiFi app logging and history curves.

Monitored parameters
Formaldehyde, total volatile organic compounds, benzene, carbon dioxide, PM2.5, PM10 and a combined air quality index, plus temperature, humidity, time and date on the flagship version
Sensing elements
Electrochemical for formaldehyde, a micro-electromechanical module for total volatile organic compounds, filtered non-dispersive infrared for carbon dioxide, laser scattering for the particle fractions, and dedicated elements for temperature and humidity
Indicative thresholds
Formaldehyde 0.080, total volatile organic compounds 0.600, benzene 0.030, carbon dioxide 1000, PM2.5 75, PM10 100 and index 100, above which the material calls a reading over the limit; the figures are printed without units
Alarm
An audible alarm sounds on the combined index only; the other parameters do not alarm
Two digital lux meters side by side, the smaller one in a green case with its sensor on a short stalk, a reading of 455 on the LCD and 23.3 degrees beneath it, and the larger one in a black case with a bigger round sensor head and a display reading 288.5 lux in automatic range

AS803F (5 models) · Light Meters

Digital Lux Meter

Digital lux meter covering 0 to 200,000 lx with a sensor head that rotates through 180 degrees, lux and foot-candle units, data hold, maximum and minimum capture and a separate ambient temperature reading.

Measuring range
0 to 200,000 lx on the four AS instruments; 1 to 100,000 lx on the ST instrument
Resolution
1 lx and 0.1 degrees Celsius on the AS instruments; 0.1 lx on the ST instrument
Accuracy
plus or minus 4 percent of reading plus 10 digits at or below 10,000 lx and plus or minus 5 percent plus 10 digits above it; plus or minus 3 percent plus 5 lx on the ST instrument
Sensor
Silicon photovoltaic cell with a colour-correction filter
Grey hand-held sound level meter with a black foam windscreen on the microphone, a red on and reset button above a liquid crystal display reading 58.6, and a sloped lower panel carrying the model number, the accuracy class against two standards, and control legends for the measurement functions

AWA5636-0 (5 models) · Noise Meters

Digital Sound Level Meter

Class 2 digital sound level meters in five configurations, from a basic instantaneous reading instrument up to an integrating and statistical model with 8000 records of storage.

Model range
AWA5636 in five configurations, numbered 0 to 4
Accuracy class
Class 2, stated against GB/T 3785.1-2010 and IEC 61672-1
Measurement range
40-130 dB(A) on the basic configuration; 30-130 dB(A) on configurations 1 to 4
Self-generated noise
<30 dB(A) on the basic configuration; <25 dB(A) on the others
Black hand-held gas detector with a blue display reading H2S 0 ppm, O2 20.3 %, CO 0 ppm and EX 0 %LEL, the words Gas Detector printed below the screen, three buttons beneath the panel and four grilles for the sensing elements in the lower body

BH-4 (2 models) · Portable Gas Detectors

Portable Gas Detector

Hand-held multi-gas and single-gas detectors with audible, visual and vibrating alarms, covering the four-gas confined space combination as standard and a long list of single gases to order.

Range
The BH-4 multi-gas instrument and the BH-90 single-gas instrument
Channels
Four on the BH-4, covering combustible gas, oxygen, hydrogen sulphide and carbon monoxide; one on BH-90
Display error
≤±5 %FS
Response time
T90 < 60 s
Orange flameproof gas detector in a round cast housing on a bracket, with a red beacon, a black antenna, a stainless steel sensing probe below the body, a digital display showing 8.8.8.8 and three small indicator labels below the display

GQ-KL800-L4 · Fixed Gas Detectors

Fixed Gas Detector

A point gas detector in an explosion-proof cast aluminium housing for continuous monitoring of combustible gas, oxygen, hydrogen sulphide and carbon monoxide, supplied as a stand-alone unit or with a controller over wired or wireless links.

Model
GQ-KL800-L4
Gases
Combustible gas, oxygen, hydrogen sulphide and carbon monoxide, with other gases available to order
Detection principle
Catalytic combustion for combustible gas; electrochemical cells for the toxic and oxygen channels
Explosion protection
Ex db IIC T6 Gb, flameproof
Hand-held gas detector lying at an angle with a flexible metal gooseneck probe rising from its top, a display reading zero against the percentage of the lower explosive limit and naming the gas group, and a vertical row of three keys below it

JLY-CP100 (2 models) · Gas Leak Detectors

Combustible Gas Leak Detector

Portable combustible gas leak detector reading 3 to 20 percent of the lower explosive limit with a flexible gooseneck probe, a three-way alarm and a full-colour display.

Detection range
3 to 20 percent of the lower explosive limit, with sub-ranges of 0 to 1000 ppm and 0 to 100 percent of the lower explosive limit
Alarm set point
10 percent of the lower explosive limit
Indication error
plus or minus 5 percent of the lower explosive limit
Gases
Methane, natural gas, biogas, hydrogen, coal gas, acetone, petrol and ethanol, with the material also naming oxides and sulfides and stating that organic combustible vapours from liquids such as petrol are detected

Test & Inspection

Bench and portable instruments used to verify electrical performance, mechanical properties, material integrity and dimensional accuracy of a product before it ships or while it is in service.

10 · AVAILABLE

Electrical Test & Measurement

Power meters, multimeters, clamp meters, insulation and earth testers, LCR meters and safety testers for electrical verification.

15 product types: Digital Multimeters · Clamp Meters · Insulation Resistance Testers · Earth Resistance Testers · Voltage Testers · Current Meters · LCR Meters · Power Meters · Energy Meters · Power Quality Analyzers · Frequency Counters · Phase Meters · Electrical Safety Testers · Circuit Testers · Electrical Test Equipment

Open the electrical test & measurement hub →
11 · AVAILABLE

Industrial Testing Equipment

Hardness, tensile and compression testers, coating thickness gauges, roughness testers, leak and pressure test benches.

12 product types: Hardness Testers · Tensile Testing Machines · Compression Testing Machines · Impact Testing Machines · Material Testing Machines · Coating Thickness Gauges · Surface Roughness Testers · Vibration Test Equipment · Leak Testers · Pressure Test Equipment · Temperature Test Equipment · Industrial Inspection Equipment

Open the industrial testing equipment hub →
Clamp meter held in one hand by its body, with the orange transformer jaw at the top, a rotary function selector and three function keys below the display, and the two test sockets along the bottom face

3266TA (3 models) · Clamp Meters

AC/DC True-RMS Clamp Meter

Clamp meter range reading current through a 25 mm jaw without breaking the circuit, from an AC-only model up to an AC/DC instrument with true-RMS conversion, 6000 counts and a 100 mF capacitance range.

Jaw opening
25 mm
AC current
1 mA to 600 A on the two AC-only models; 10 mA to 600 A on the AC/DC model
DC current
10 mA to 600 A on the AC/DC model only
AC and DC voltage
AC 1 mV to 600 V; DC 0.1 mV to 600 V
Compact programmable safety tester shown from the front with the two-line LCD at the upper left, a row of function keys beneath it and the test terminals along the lower right

7110 (8 models) · Electrical Safety Testers

Compact AC/DC Withstand Voltage and Insulation Tester

Compact programmable safety tester with 5 kV AC and 6 kV DC withstand voltage, insulation resistance to 9999 MΩ, five stored programs and PLC remote control.

AC output
0 to 5.00 kV, 12 mA
DC output
0 to 6.00 kV, 5 mA, on four of the eight models
Frequency
50 or 60 Hz, selectable
Leakage limits
0.10 to 12.00 mA AC and 0.02 to 5.00 mA DC, upper and lower set independently
Benchtop ground bond tester seen from the front, with a red reset button and a green test button at the left, a two-line LCD above four setup keys at the centre and current and return terminals at the right

7305 (3 models) · Electrical Safety Testers

Programmable Ground Bond Resistance Tester

Programmable ground bond tester with a regulated AC test current, settable resistance limits, self-zero lead correction and PLC remote control in three current classes.

Output current
3 to 33 A on 7305, 1 to 40 A on 7314, 1 to 60 A on 7316
Maximum output voltage
6 V on 7305, 8 V on 7314, 12 V on 7316
Resistance range
0 to 510 mΩ on 7305; 0 to 600 mΩ on 7314 and 7316
Frequency
50 or 60 Hz, selectable, ±100 ppm
Benchtop safety compliance analyser seen from the front, with a backlit dot matrix display at the upper centre, a red reset button and a green test button at the left, function keys and a numeric keypad below the display, and current and return terminals at the right

7440 (4 models) · Electrical Safety Testers

Four-in-One Electrical Safety Compliance Tester

Bench safety compliance analyser combining AC and DC withstand, insulation resistance and, on the top model, ground bond testing, with stored programs and a matrix scanner interface.

AC withstand
0 to 5 kV, up to 40 mA
DC withstand
0 to 6 kV, up to 9999 μA
Insulation resistance
100 to 1000 V DC, 1 to 9999 MΩ
Ground bond
3 to 40 A, 0 to 600 mΩ, on 7440 only
Benchtop high voltage tester seen from the front, with a backlit two-line display at the upper centre, a red reset button and a green test button at the left, function keys and a numeric keypad beneath the display, and high voltage and return terminals at the right

7460 (2 models) · Electrical Safety Testers

10 kV Programmable Withstand Voltage Tester

Programmable high voltage withstand tester in an alternating and a direct version, with a regulated output, fifty linked program groups, arc detection and remote control.

AC output
0.00 to 10.00 kV at 10 mA, on 7460
DC output
0.00 to 10.00 kV at 5000 μA, on 7462
Voltage resolution
0.01 kV
Leakage limits, AC
Upper 0 to 10.0 mA, lower 0.1 to 10.0 mA
Bench insulation tester in a white case seen from the front, with a two-line liquid crystal display in the centre showing a set voltage and a resistance limit, a red reset button and a green test button at the left, four small keys below the display and a red high-voltage terminal beside a black return terminal at the right

8205 (2 models) · Insulation Resistance Testers

Insulation Resistance and Battery Short-Circuit Tester

Bench insulation tester with a 100 to 1000 V direct output, resistance measurement to 9999 MΩ, programmable rise and test times, a PLC remote interface and automatic discharge.

Output voltage
100 to 1000 V DC, 1 V resolution, ripple below 2%
Resistance range
1 MΩ to 9999 MΩ, automatically selected
Resistance accuracy
±(2% of setting + 2 counts) from 1 to 1000 MΩ; ±(3% + 2 counts) to 9999 MΩ
Rise time
1.0 to 999.9 s in the parameter table; 0.1 to 999.9 s in the description, both carried
Small black bench instrument with a colour display reading 0.500 V and zero current, six blue preset voltage keys beneath it, a power switch at the lower left, a round knob at the upper right and a pair of red and black output terminals on the right

B0102 (3 models) · Electrical Test Equipment

Battery Simulator for Protection Board Testing

Bidirectional battery simulator range from 5 V to 60 V, sinking and sourcing current at the same terminals, with microamp current resolution and six stored voltages.

Voltage range
0 to 5 V on B0102; 0 to 20 V on 906B; up to 60 V on the 906 variants
Current range
0 to 2 A on B0102; 0 to 12 A on 906B; up to 30 A on the 906 variants
Power range
0 to 10 W on B0102; 0 to 240 W on 906B; up to 500 W on the 906 variants
Setting resolution
1 mV on voltage, 1 mA on current
Bench turns tester with a vertical sensing rod rising from the top cover, a green LED display across the front showing an open-circuit indication, three alarm setup keys at the lower right and a power switch at the far right

CH1201 (4 models) · LCR Meters

Coil and Winding Turns Counter with DC Resistance

Bench turns counters for coils up to 80,000 turns, with automatic ranging, no calibration before a measurement, and DC resistance measurement on the two R models.

Turns range
1 to 80,000 on CH1201 and CH1201R; 1 to 30,000 on CH1200 and CH1200R
Turns accuracy
±0 turns to ±1 turn at the low end, then ±0.2% or ±0.3%, and ±0.5% at the top of the 80,000 range
Turns speed
3 readings per second on CH1201; 1.5 on CH1200
DC resistance
100 µΩ to 200 kΩ on CH1201R; 100 µΩ to 20 kΩ on CH1200R
Bench instrument in a blue-grey case with a 4.3 inch colour screen at the left showing two columns of voltage, current and power readings, a numeric keypad and a rotary knob in the centre, and two load terminals at the lower right

CH2711 (4 models) · Power Meters

Combined Electronic Load and Power Meter Tester

Bench instrument combining a 150 W electronic load in four modes with a true root mean square power meter, on a 4.3 inch colour screen with a numeric keypad and USB data storage.

Load ratings
0 to 150 V at 0.1 mA to 30 A, or 0 to 500 V at 0.1 mA to 15 A, 150 W
Load modes
Constant current, constant voltage, constant resistance and constant power
Load resolution
0.1 mV and 0.1 mA at the bottom of the scale
Meter input
5 to 600 V AC, 10 mA to 20 A AC; 0.05 mA to 5 A AC on the two small-current models
Rear panel of a bench power meter in a blue-grey case, with four binding posts in two pairs at the left, a wiring diagram between them, and a mains inlet, fuse holder, USB socket and a nine-pin serial socket at the right

CH2801 (5 models) · Power Meters

Single-Channel Digital Power Meter with Harmonic Analysis

Single-channel bench power meter with a 4.3 inch colour screen, true root mean square measurement, energy totals, and five models reaching 40 A or down to 0.05 mA, one with harmonic analysis.

Channels
One, single-phase
Voltage
5 to 600 V AC, 700 V AC peak, 0.1 V resolution
Current
10 mA to 10 A or 20 A as printed; 5 mA to 20 A, 0.05 mA to 5 A or 0.5 mA to 40 A by model
Power
0.1 W to 12 kW; 0.001 W to 3000 W on the low-current model
Benchtop instrument seen from the front, with a colour display at the left showing a large voltage and current readout above a row of smaller values, a keypad and direction keys at the right, a USB port on the front panel and two screw terminals marked plus and minus along the lower right

CH6311A (5 models) · Electrical Test Equipment

Ripple Voltage and Current DC Electronic Load

Five-model programmable DC load with 150 V or 500 V input, 150 W or 300 W, six load modes and 500 kHz ripple measurement with peak and valley capture.

Input voltage
0 to 150 V on three models; 0 to 500 V on two
Input current
0.1 mA to 15 A, 30 A or 60 A depending on model
Input power
150 W on CH6311A; 300 W on the other four
Load modes
Constant voltage, constant current, constant power, constant resistance, short circuit and open circuit
Off-white benchtop load seen from the front, with a colour screen at the left showing voltage, current and power readings, a numeric keypad and adjustment knob beside it, ventilation slots across the right-hand half and two pairs of input terminals with sense terminals along the bottom right

CH6321A (5 models) · Electrical Test Equipment

Programmable DC Electronic Load

Programmable DC electronic load with 150 V and 500 V inputs, 60 to 240 A, 600 to 1500 W, six load modes and battery, dynamic and OCP test functions.

Input voltage
0 to 150 V on four models; 0 to 500 V on four models
Input current
0.1 mA to 60 A, 120 A or 240 A depending on model
Input power
600 W, 900 W, 1200 W or 1500 W depending on model
Load modes
Constant voltage, constant current, constant power, constant resistance, short circuit and open circuit
Benchtop electronic load seen from the front, with a colour display at the left showing voltage, current and power readings, a numeric keypad and rotary knob beside it, a vent grille across the right half, and two pairs of binding posts marked as sense and input along the lower right

CH8811+ (6 models) · Electrical Test Equipment

High Power Programmable DC Electronic Load

Six-model programmable DC load from 600 W to 1200 W, with 120 V or 360 V input, 60 A, six load modes, battery discharge with curve plotting and remote sense.

Input voltage
0 to 120 V on three models; 0 to 360 V on the other three
Input current
1 mA to 60 A on all six, as printed in the parameter table
Input power
600 W, 900 W or 1200 W, one of each in both voltage classes
Load modes
Constant voltage, constant current, constant power, constant resistance, short circuit and open circuit
Bench instrument in a dark blue case with a colour display showing voltage and current readings at the left, a numeric keypad and a rotary knob at the right, and a pair of output terminals marked BATTERY along the lower right

CH906A (2 models) · Electrical Test Equipment

Charge and Discharge Battery Simulator

Linear battery simulator in two ranges, 20 V at 10 A or 10 V at 2 A, with automatic changeover between charge and discharge, microamp readback and a 4.3-inch touchscreen.

Discharge voltage
0.1 to 20 V on CH906A; 0.1 to 10 V on CH906D
Discharge current
0 to 10 A on CH906A; 0 to 2 A on CH906D
Charge voltage
0.2 to 20 V on CH906A; 0.2 to 10 V on CH906D
Charge current
Up to 10 A below 10 V and 5 A above on CH906A; up to 2 A on CH906D
Benchtop electronic load seen from the front, with a colour display at the left showing voltage, current and power readings against limit values, a numeric keypad and two rotary knobs at the right, soft keys along the lower edge and carrying brackets at the sides

CH9720B (4 models) · Electrical Test Equipment

Wide-Range Programmable DC Electronic Load

Four-model programmable DC electronic load with a 0 to 360 V input, 150 W or 300 W, five load modes, battery discharge testing and 500 kHz ripple measurement.

Input voltage
0 to 360 V on all four models
Input current
1 mA to 30 A as printed in the parameter table; 0.1 mA on the model cards
Input power
150 W on CH9720B and CH9720BU; 300 W on CH9720C and CH9720CU
Load modes
Constant voltage, constant current, constant power, constant resistance and short circuit
Benchtop fast-charge tester seen from the front, with a colour display at the left showing voltage, current and power readings beside a protocol panel, a numeric keypad and a rotary knob at the right, and three load terminals along the lower edge

CH9721P+ (5 models) · Electrical Test Equipment

Fast Charge Protocol and Electronic Load Tester

Four-model series combining a programmable DC load with fast-charge protocol detection, 500 kHz sampling, ripple measurement and over-current protection testing.

Input power
150 W on the three 60 V and 150 V models; 300 W on the largest
Input voltage
0 to 60 V, or 0 to 150 V on the two higher models
Input current
0.1 mA to 6 A, or 0.1 mA to 30 A on the two higher models
Accuracy
±(0.05% + 0.03% FS) on voltage and current
Multi-channel resistance scanner seen from the front, with a colour display showing eight channel readings in two columns, a keypad at the right and a four-terminal socket at the lower right

CXT2518-4 (5 models) · Electrical Test Equipment

Multi-Channel and Multi-Point Resistance Scanner

Bench scanners that step a four-wire measuring circuit through 2 to 64 channels, applying per-channel limits, in ranges from 1 µΩ to 2 MΩ and at up to 40 readings per second.

Channels
2 to 64 per instrument; 3 to 100 on one family, to order
Measurement
DC resistance, four terminals per channel
Resistance range
1 µΩ to 2 MΩ on the wide families; 10 µΩ to 200 kΩ on the common ones
Accuracy
0.05% typical; 0.02% on one family
Benchtop winding resistance tester in a grey case, with a colour display divided into line and phase resistance columns above a row of soft keys, a numeric keypad at the right and three test sockets marked A, B and C along the lower edge

CXT3513 · Electrical Test Equipment

Motor Winding Resistance Unbalance Tester

Benchtop tester measuring the three winding resistances of a three-phase motor from 10 µΩ to 20 kΩ, calculating spread and unbalance for star or delta connection and sorting against limits.

Resistance range
10 µΩ to 20 kΩ
Basic accuracy
0.05%, with the detailed specification in the operating manual
Test current
≤ 100 mA
Display
4.3 inch IPS colour LCD, 480 × 272, 4½ digit readings
Hand-held digital multimeter in an orange sleeve shown from the front with the LCD reading 19.99, the rotary range selector below it and four test sockets along the bottom edge, together with a second view of the same instrument from the side

DT9205A (3 models) · Digital Multimeters

Handheld Digital Multimeter

Handheld digital multimeter with a 1999-count display and 32 ranges covering AC and DC voltage and current, resistance, capacitance, diodes and transistors, with continuity, overload protection and automatic switch-off.

Display
1999 counts, 3½ digits
DC voltage
200 mV to 1000 V in five ranges
AC voltage
200 V and 750 V
DC and AC current
2 mA to 20 A
Narrow benchtop power supply seen from the front, with a large LED display reading 30.00 volts, 5.000 amps and 0.000 watts, two adjustment knobs, an ON/OFF key, a quick-charge USB socket and one red and one black output terminal

eTM-152MF (5 models) · Electrical Test Equipment

Miniature Adjustable DC Power Supply

Bench DC power supply in a narrow 80 mm case, with 15 to 150 V and 2 to 20 A models, four-digit voltage, current and power readout, and preset without shorting the output.

Output voltage
15, 30, 60, 100 or 150 V maximum, by model
Output current
2 to 20 A maximum, by model
Readout
Four-digit LED for voltage, current and power at the same time
Setting resolution
10 mV below 100 V, 0.1 V at 100 V and above
Benchtop high-voltage tester seen from the front, with a blue dot-matrix display at the upper left showing a voltage and a current reading, soft keys beside it, a direction pad and numeric keypad at the right, and two round test sockets along the lower edge

HG2536 · Electrical Test Equipment

Gas Discharge Tube Characteristic Tester

Tester for ceramic gas discharge tubes and surge arrester parts, with 5 to 2000 V output, leakage measurement to 2200 µA and a HANDLER interface for sorting.

Output voltage
5 to 2000 V, continuously settable, ±1%
Voltage rise rate
100 V per second, ±1%
Voltage measurement accuracy
0.5% ±0.1 V
Leakage range
0.00 to 2200.0 µA, error within ±1%
Benchtop diode tester seen from the front, with a blue dot-matrix display at the upper left showing four stacked readings labelled for reverse voltage, reverse leakage, forward current and forward voltage, soft keys beside it, a direction pad and numeric keypad at the right, and two round test sockets along the lower edge

HG2600 · Electrical Test Equipment

Diode Reverse Voltage and Leakage Current Tester

Benchtop diode tester measuring forward voltage and forward current, reverse voltage to 1200 V and reverse leakage to 2200 µA, with three test speeds and a PLC interface.

Parameters measured
Reverse voltage Vka, reverse leakage Ika, forward current Iak and forward voltage Vak
Forward voltage
0.1 to 2.5 V
Forward current
0.00 to 30 A, with the range separator not legible in the source
Reverse voltage
5 to 1200 V, in two ranges split at 135 V
Bench capacitor test instrument seen from the front, with two green LED readouts across the upper panel, a row of four BNC terminals and a ground terminal along the lower left, and a keypad with arrow keys at the lower right

HG2611D · LCR Meters

Electrolytic Capacitor Leakage Current Tester

Bench leakage current tester for aluminium electrolytic capacitors, with a 0 to 500 V adjustable charging voltage, three current ranges from 0.01 µA to 30 mA and settable charge and discharge times.

Test voltage
0 to 500 V, continuously adjustable
Leakage ranges
0.01 to 3 µA, 3 µA to 3 mA, 3 mA to 30 mA
Reading error
±1% ±2 digits
Charge time
0 to 99 s, ±2%
Benchtop inductance meter seen from the front, with a blue backlit LCD at the left showing an inductance value and a quality factor, a numeric keypad and arrow keys at the right, and four BNC terminals with a ground terminal along the lower front edge

HG2776A (2 models) · LCR Meters

Precision Inductance Meter with Wide Frequency Coverage

Two bench inductance meters, one covering 100 Hz to 200 kHz in 37 points at 0.05% accuracy and one covering four points to 10 kHz at 0.1%, both with four-terminal connection and multi-parameter display.

Test frequency
100 Hz to 200 kHz in 37 points on HG2776A; 100 Hz to 10 kHz in four points on HG2775A
Basic accuracy
0.05% on HG2776A; 0.1% on HG2775A
Test level
10 mV to 2.00 V in 10 mV steps on HG2776A; 0.1 V, 0.3 V or 1 V on HG2775A
Inductance range
0.01 nH to 9999.99 H
Benchtop tester seen from the front, with a blue dot-matrix display at the upper left showing two measured parameters, a column of soft keys beside it, a direction pad and numeric keypad at the right, and two round test sockets along the lower edge

HG2788 · Electrical Test Equipment

Piezo Buzzer Plate Parameter Tester

Benchtop tester for piezoelectric buzzer plates, measuring equivalent resistance Rs and resonant frequency Fs, with seven-bin sorting, three test speeds and a HANDLER interface.

Parameters measured
Equivalent resistance Rs and resonant frequency Fs
Basic accuracy
±1% ±5 Ω
Resistance display
25 Ω to 2200 Ω; the display-range row gives a 20 Ω lower limit
Frequency display
0.8 kHz to 19.99 kHz
Bench LCR bridge in a grey case, with a five-digit LED display showing a primary and a secondary reading, four coaxial test terminals across the lower centre of the panel, a column of range and function keys at the right and the power switch at the left

HG2810B (6 models) · LCR Meters

Bench LCR Digital Bridge

Bench LCR bridges covering fixed-frequency and wide-band models, with 0.10% or 0.05% basic accuracy, five-terminal connections, bin sorting and optional RS232 and HANDLER interfaces for incoming inspection and production sorting.

Test frequencies
100 Hz, 120 Hz, 1 kHz and 10 kHz on the general models; up to 100 kHz on HG2817 and HG2817B; 8 points to 100 kHz on HG2817D; 37 points from 50 Hz to 200 kHz on HG2817A
Basic accuracy
0.10% on the general models; 0.05% on HG2816A and HG2817A
Test level
0.3 V on HG2810B; 0.1 V, 0.3 V or 1.0 V on most other models; 10 mV to 2.00 V in 10 mV steps on HG2816A and HG2817A
Display ranges
L 0.01 µH to 99999 H and C 0.01 pF to 99999 µF on the general models, with wider ranges on the LCD models
Benchtop core tester seen from the front, with a blue dot-matrix display at the upper left showing a voltage reading in millivolts and a column of range values, soft keys beside it, a direction pad and numeric keypad at the right, and two round test sockets along the lower edge

HG2900 · Electrical Test Equipment

Magnetic Core Magnetization Characteristic Tester

Benchtop tester for soft magnetic cores and core-sorting machines, measuring induced voltage from 1 μV and magnetomotive force to 2.00 A, with fourteen pass bins and five test speeds.

Voltage range
1 μV to 33 mV, in three ranges of 0.3, 3.0 and 30 mV
Voltage resolution
1 μV
Magnetomotive force
0.00 to 2.00 A, accuracy ±1%
Sorting
One under-limit bin, fourteen pass bins and one over-limit bin
Benchtop winding resistance tester seen from the front, with a blue backlit LCD at the left showing three channel readouts stacked vertically, a numeric keypad and arrow keys at the right, and two circular multi-pin test connectors along the lower front edge beside the power switch

HG3030 · LCR Meters

Three-Phase Motor Winding Resistance Balance Tester

Three-channel DC resistance tester for motor windings, covering 10 µΩ to 2 MΩ at 0.05% accuracy, with simultaneous three-phase display, percentage comparison and pass or fail sorting.

Channels
Three, measured and displayed together
Resistance range
10 µΩ to 2 MΩ
Best accuracy
0.05%
Test current
DC 100 mA down to 1 µA, eight ranges
Benchtop insulation resistance meter in a pale grey case, with a colour screen at the left showing a resistance reading above a current reading and a column of menu labels, a keypad at the right and an input socket beside two high-voltage terminals at the lower right

HG7683 (2 models) · Insulation Resistance Testers

High-Speed Wide-Range Insulation Resistance Tester

Bench insulation resistance meter with a voltage range from 1 V, resistance to 100 TΩ, three measuring speeds, five-bin sorting and 600 stored records on the wide-range model.

Test voltage
1 to 1000 V continuous on the wide-range model; 10 to 1000 V settable on the other
Resistance range
500 Ω to 100 TΩ on the wide-range model; 100 kΩ to 1 TΩ on the other
Current range
1 pA to 2 mA on the wide-range model; 0.001 to 200.0 µA on the other
Accuracy
1% while resistance is below 10 GΩ and current above 10 nA; ±3% ±3 digits below 1 TΩ and ±8% ±3 digits above it on the other model
Bench transformer tester in a light grey case, with a colour LCD at the left listing turns ratio, inductance, leakage inductance and resistance readings, a column of soft keys and a numeric keypad at the right, and a test fixture resting on top of the case connected to the front panel by a ribbon cable and two coaxial leads

HG7729 (4 models) · LCR Meters

Transformer Comprehensive Tester

Four transformer testers with 20-channel scanning, LCR and DC resistance measurement at 0.05% basic accuracy, built-in DC bias and test frequencies from 20 Hz to 1 MHz for production testing of wound components.

Test frequency
20 Hz to 200 kHz on HG7729; 20 Hz to 300 kHz on HG7729A and HG7729B; 20 Hz to 1 MHz on HG7729C
Scanning
20-channel transformer scan on all four models
LCR parameters
|Z|, |Y|, C, L, X, B, R, G, D, Q and phase, plus DC resistance, turns and phase
Transformer scan parameters
Turns ratio, number of turns, phase, inductance, capacitance, leakage inductance, quality factor, AC resistance, DC resistance, balance, pin short and LED
Benchtop hipot tester seen from the front, with a red stop button at the left, a colour display showing a withstand test, a keypad and function keys at the right, eight channel terminals labelled CH1 to CH8 along the lower edge and output and return terminals at the far right

HG7804 (2 models) · Electrical Safety Testers

High-Power AC/DC Withstand and Insulation Tester

High-power safety tester with AC and DC withstand, insulation resistance, open and short detection and arc detection, in a four-channel and an eight-channel version with scanner expansion.

AC withstand
0.05 to 5 kV, 0.1 to 30 mA, 50 or 60 Hz
DC withstand
0.05 to 6 kV, 0.01 to 10 mA
Insulation resistance
0.05 to 1 kV, 0.1 MΩ to 10 GΩ
Test power
150 V/A as printed in the material
Precision LCR bridge seen from the front, with a colour TFT display at the left showing capacitance, dissipation factor and series resistance readings, a column of soft keys beside the display, a rotary knob and numeric keypad at the right, and a row of coaxial test terminals along the lower edge

HG7829A (3 models) · LCR Meters

Precision LCR Digital Bridge with Graphical Sweep

Precision bench LCR bridges covering 20 Hz to 300 kHz, 500 kHz or 1 MHz at 0.05% basic accuracy, with 1 mHz frequency resolution, a 7-inch colour display, 40-point list sweeps and graphical analysis.

Test frequency
20 Hz to 300 kHz on HG7829A, to 500 kHz on HG7829B, to 1 MHz on HG7829C
Frequency resolution
1 mHz, continuously variable
Basic accuracy
0.05%
Test level
5 mV to 2 V as standard; 5 mV to 10 V on the enhanced version
Bench winding insulation tester in a light grey case, with a 7-inch colour LCD at the left showing two overlaid pulse waveforms and a green OK result, a column of soft keys beside the screen, a rotary knob and numeric keypad at the right, and a ground terminal beside a red high-voltage terminal at the lower right

HG9813 (4 models) · LCR Meters

Winding Insulation Tester

Four impulse winding testers reaching up to 10 kV, with corona analysis, high-speed waveform capture, a 7-inch colour display and pass or fail outputs for inter-turn insulation testing of coils and windings.

Pulse voltage
100 V to 3000 V on HG9813, 100 V to 5000 V on HG9815, 200 V to 6000 V on HG9816 and 300 V to 10,000 V on HG9810, all in 10 V steps at 5% ±10 V
Pulse energy
0.09 J on HG9813, 0.25 J on HG9815, 0.36 J on HG9816 and 0.5 J on HG9810
Inductance range
≥10 µH on HG9813, HG9815 and HG9816; ≥50 µH on HG9810
Test speed
15 per second on HG9813 and HG9815, 12 on HG9816 and 8 on HG9810
Light grey bench instrument with a liquid crystal display showing a table of battery readings on the left, a keypad with arrow keys and a numeric block on the right, and four terminals marked P+, R+, P- and R- along the lower right

HTB-2020 (2 models) · Electrical Test Equipment

Battery Capacity and Internal Resistance Tester

Two-model battery tester measuring voltage to 80 V, over-current to 20 A, internal resistance, identification resistance and capacity, with a built-in DC supply for charge and discharge.

Battery voltage range
0 to 20.000 V on HTB-2020; 0 to 80.000 V on HTB-2060, at 0.001 V
Over-current range
0 to 10.000 A on HTB-2020; 0 to 20.000 A on HTB-2060, at 0.001 A
Internal resistance
0 to 999.0 mΩ, resolution 0.1 mΩ
Identification resistance
0.1 to 999.9 kΩ, resolution 0.1 kΩ
White bench instrument with an 8-inch touchscreen showing a menu of icons, a power switch and a USB socket on the left, and four round multi-pin test sockets labelled CH1 to CH4 on the right

KS8651 (6 models) · Electrical Test Equipment

Multi-Port Fast-Charge Comprehensive Tester

Bench fast-charge tester with a built-in electronic load, 60 V and 10 A per port, protocol testing to PD3.1, four or eight ports and an 8-inch Android touchscreen.

Maximum test voltage
60 V
Maximum test current
10 A
Maximum test power
150 W on the standard models, 300 W on the H models
Port arrangements
Single module with 4 ports; four modules with 4 or 8 ports
White bench instrument with a 10-inch touchscreen showing a menu of six icons, a power switch and a USB socket on the left, and ten round multi-pin test sockets in two vertical columns labelled M1-0 to M1-4 and M2-0 to M2-4 on the right

KS8661 · Electrical Test Equipment

Power Bank Comprehensive Tester

Ten-port bench tester for power banks, adapters and storage supplies, with a built-in electronic load, 20 V and 10 A per port, 200 W and a 10-inch touchscreen.

Maximum test voltage
20 V
Maximum test current
10 A
Maximum test power
200 W
Channel arrangement
Four modules, ten ports
Bench instrument with a light grey case and black front panel, a colour display showing four large zero readings above five soft keys, a row of status values beneath, a single large adjustment knob at the upper right and a pair of output terminals marked IN and OUT at the lower right

KS9830 (5 models) · Electrical Test Equipment

Battery Simulator Power Supply

Five-model battery simulator range covering 20 to 48 V and up to 20 A, with 1 mV and 1 mA setting resolution, four-wire remote sensing and readback of voltage, current and power.

Output voltage
0 to 20 V on KS9830; 0 to 24 V on KS9831 and KS9831A; 0 to 48 V on KS9832 and KS9832A
Output current
0 to 12 A on KS9830; 10 or 20 A switchable on the other four
Output power
0 to 240 W on KS9830, KS9831 and KS9831A; 0 to 450 W on KS9832 and KS9832A
Setting resolution
1 mV on voltage, 1 mA on current
Light grey benchtop meter seen from the front, with three range keys and a power switch at the left, a four-digit red LED display in the centre showing 0.000, two red current terminals below it, and an INPUT socket with a COM terminal at the right beside two warning symbols

LK149A (5 models) · Electrical Safety Testers

Digital High Voltage Meter

Benchtop high voltage meter for verifying hipot tester output, covering 10 kV and 20 kV AC/DC ranges with 0.001 kV resolution and 0.4% DC accuracy.

Voltage ranges
0 to 10.000 kV AC and DC on LK149A, LK7005 and LK7015; 0 to 19.999 kV on LK149B and LK7020
DC accuracy
±(1% + 2 counts) on LK149A and LK149B; ±(0.4% of reading + 0.02% of range) on LK7005, LK7020 and LK7015
AC accuracy
±(1% + 2 counts) on LK149A and LK149B; ±(0.8% of reading + 0.02% or 0.04% of range) on the other three
Resolution
0.001 kV on every model
Light grey benchtop tester seen from the front, with a small model plate at the upper left, three red LED readouts across the top centre labelled for time, leakage current and voltage, a large grey voltage knob at the lower left, a row of setting keys in the middle and two high-voltage output terminals at the right

LK2670AX (6 models) · Electrical Safety Testers

Adjustable AC/DC Withstand Voltage Tester

Adjustable hipot tester series with 0 to 5 kV and 0 to 10 kV outputs, leakage ranges to 500 mA, presettable test time and optional PLC control.

Output voltage
0 to 5 kV AC or AC/DC on the 5 kV models; 0 to 10 kV AC or AC/DC on the 10 kV models; 0 to 3 kV DC on LK2673C
Leakage current ranges
0 to 2 mA or 20 mA; 100 mA, 200 mA and 500 mA ranges on the higher-current models
Accuracy
±(5% + 3 counts) across the series
Test time
1 to 99 s as standard, 1 to 999 s on LK2672C+ and available as a custom setting
Grey benchtop tester seen from the front, with a model plate at the upper left, three green LED readouts across the top, a control column at the left holding a preset knob and green and red buttons, a large voltage knob in the centre and two large red high-voltage output sockets at the right

LK2674 (5 models) · Electrical Safety Testers

Ultra-High-Voltage AC/DC Hipot Tester

Ultra-high-voltage hipot tester reaching 15, 20, 30 or 50 kV, with AC or AC/DC output, leakage ranges to 20 mA and a 1 to 99 s preset test time.

Output voltage
0 to 15 kV, 0 to 20 kV, 0 to 30 kV or 0 to 50 kV depending on model
Output type
AC on the AC models; AC and DC on the AC/DC models, selected by a front-panel switch
Leakage range
0 to 2 mA or 10 mA on the standard models; 0 to 2 mA or 20 mA on the + models
Accuracy
±(5% + 5 counts); ±(5% + 3 counts) on the 15 kV and 20 kV models
Off-white benchtop tester seen from the front, with a model plate at the upper left, three red digital readouts in a black strip across the top, a row of setting keys and two indicator lamps beneath them, a large voltage knob at the left, a blue selector and a red start button at the bottom centre, and a universal mains socket at the right

LK2675A (5 models) · Electrical Safety Testers

Appliance Leakage Current Tester

Leakage current tester with 0 to 250 V adjustable output, 300 VA to 2000 VA supplies, true-RMS AC/DC measurement to 1 MHz and a three-phase model.

Output voltage
0 to 250 V on the single-phase models; three-phase on LK2675S
Transformer capacity
300 VA, 1000 VA or 2000 VA depending on model; LK2675E and LK2675S use an external variac
Leakage range
0 to 2 mA or 0 to 20 mA, accuracy ±(5% + 5 counts)
Measurement
True-RMS AC/DC conversion, responding to direct, alternating, sine and composite waveforms
Off-white benchtop tester seen from the front, with a large grey current knob at the left, a black display strip carrying three red digital readouts across the centre, a row of small keys below it and two pairs of red and black terminals on a separate panel at the right

LK2678BX (4 models) · Electrical Safety Testers

Four-Wire Ground Bond Resistance Tester

Four-terminal ground bond tester with 1 to 50 A output across four models, 0 to 600 mΩ ranges, presettable test time and upper limit alarm.

Output current
5 to 32 A on LK2678BX, 10 to 50 A on LK2678, 3 to 32 A on LK7305, 0.01 to 45 A on LK7340
Resistance range
0 to 200 mΩ or 0 to 600 mΩ on LK2678BX and LK2678; 0 to 510 mΩ on LK7305; 0 to 600 mΩ on LK7340
Resistance accuracy
±5% on LK2678BX and LK2678; ±2% on LK7305 and LK7340
Test time
1 to 99 s on LK2678BX, 1 to 999 s on LK2678, 0.1 to 999.9 s on LK7305, 0 or 0.5 to 999.9 s on LK7340
Bench insulation resistance tester in a pale grey case, with a two-line backlit liquid crystal display showing a stored setting and a test voltage in the centre, a red reset button and a green test button at the left, four small keys below the display and a red high-voltage terminal beside a black return terminal at the right

LK2679C (6 models) · Insulation Resistance Testers

Programmable Insulation Resistance Tester

Programmable insulation resistance tester with 0.5 to 1000 V direct output, resistance to 10 TΩ, leakage current from 10 pA and SCPI control over USB, RS232, RS485 or a handler interface.

Resistance range
10 kΩ to 10 TΩ on the programmable 1 kV model; 100 kΩ to 10 TΩ on the manual 1 kV model
Test voltage
0.5 to 1000 V continuously on the programmable models; fixed taps from 10 V on the manual ones
Leakage current
10 pA to 1 mA on the programmable models
Accuracy
±2% above 10 nA, ±5% below 10 nA and ±10% below 1 nA
Light grey benchtop tester seen from the front, with a model plate at the upper left, three green LED readouts across the top, a preset control column at the left, a row of setting knobs above a green start key and a red reset key, a large voltage knob in the centre and a single high-voltage output socket at the right

LK2680A (4 models) · Electrical Safety Testers

Medical Electrical Safety Tester

Medical safety test range covering withstand voltage, ground bond resistance and leakage current, with arc detection, true-RMS measurement and 1 MHz response.

Withstand output
0 to 5 kV AC on LK2680A; 0 to 5 kV AC or DC on LK2680D
Leakage ranges
0 to 2 mA or 20 mA, AC on LK2680A and LK2680CX; AC or DC on LK2680D
Ground bond
5 to 32 A through 0 to 600 mΩ on LK2680B, open-circuit voltage 6 V or less
Leakage test voltage
0 to 250 V on LK2680CX, with a 500 VA isolation transformer as standard
Light grey benchtop tester seen from the front, with a green start button and a red stop button stacked at the left, a yellow-green two-line LCD in the centre showing a set voltage and current, four soft keys beneath it, three indicator lamps at the upper right and a high-voltage terminal with a return terminal below it

LK7110+ (5 models) · Electrical Safety Testers

SCPI Programmable Hipot and Insulation Tester

Menu-driven programmable hipot tester with 5 kV AC and 6 kV DC outputs, insulation resistance to 9999 MΩ, four test modes and standard RS232 and PLC interfaces.

Output voltage
0 to 5 kV AC on all models; 0 to 6 kV DC on LK7122+, LK7122U and LK9302
Leakage ranges
0 to 12 mA AC and 0 to 5 mA DC; 0 to 999.9 µA AC or DC on LK7122U
Insulation resistance
1 to 9999 MΩ at 100 to 1000 V DC on LK7122+, LK7122U and LK9302
Test modes
Withstand, insulation, withstand then insulation, insulation then withstand; LK7110+ and LK9302B run the withstand mode only
Light grey benchtop tester seen from the front, with a green start button above a red stop button at the left, a colour screen showing a test menu in the centre, a keypad with menu keys and numeric keys at the right, and a row of eight identical high-voltage terminals along the bottom edge beside a separate output terminal

LK7140P (6 models) · Electrical Safety Testers

Multi-Channel Programmable Hipot Tester

Programmable hipot and insulation tester with 5 kV AC and 6 kV DC outputs, 50 GΩ insulation range, arc detection and four or eight scanning channels.

AC output
0.10 to 5.00 kV, 0 to 20.00 mA
DC output
0.10 to 6.00 kV, 0 to 10.00 mA
Insulation resistance
0.1 MΩ to 50.0 GΩ at 0.10 to 1.00 kV
Current accuracy
±(2% of reading + 5 counts) on both AC and DC
Grey benchtop instrument seen from the front, with a blue LCD showing a multi-step test menu at the left, five function keys beside it, a numeric keypad and arrow keys in the centre, four indicator lamps above the keypad and a red reset button above a green test button at the right

LK9661D (3 models) · Electrical Safety Testers

Six-in-One Electrical Safety Compliance Tester

Combined safety compliance tester running withstand, insulation, ground bond, leakage and no-load power tests in one sequence, with 100 programs of eight steps.

AC withstand
200 to 5000 V, 0.10 to 25.00 mA, 1 to 300 s
DC withstand
0 to 10 mA at 0.3 to 6 kV on LK9661D only
Insulation resistance
1 to 2000 MΩ at 500 or 1000 V DC
Ground bond
5.0 to 30.0 A into 10.0 to 600 mΩ, 1 to 60 s
Benchtop power meter with a pale case, four red LED windows arranged two by two with the labels VOLTAGE, CURRENT, POWER and PF over them, and a six-key panel with two indicator lamps at the right

PW9800 (5 models) · Power Meters

Wide-Range Single-Phase Digital Power Meter

Single-phase power meter range with ratings from 5 mA to 200 A, four-window LED display, five readings per second and optional RS232, RS485 or relay output.

Measurement
Voltage, current, active power, power factor and frequency; the base model has no frequency display
Voltage range
5 to 400 V AC; 2 to 400 V on two models as carded; 800 V peak
Current range
5 mA to 20 A on the base rating, and up to 200 A on the highest rating of the alarm model
Power range
0.1 W to 16.5 kW
Upright bench power supply seen from the front, with a dark display reading 30.00 volts and 5.000 amps, a CV lamp lit, six small keys including M1 to M3, a large rotary knob and three output posts at the bottom

QJ300N (4 models) · Electrical Test Equipment

Adjustable Linear DC Power Supply

Linear bench supply, 30 V at 3 or 5 A, with 1 mVrms ripple, fine and coarse adjustment on one knob, three stored settings and an option for USB control.

Output voltage
0 to 30 V, continuously adjustable
Output current
0 to 3 A or 0 to 5 A, by model
Setting accuracy
0.5% + 20 mV on voltage, 0.1% + 5 mA on current, at 25 ±5 °C
Ripple
1 mVrms on voltage and 3 mArms on current, measured from 20 Hz to 20 MHz
Bench resistance meter seen from the front, with a colour display reading 1.000 mΩ at the left, a numeric keypad at the right and the four test terminals at the lower right

SJ2511 (6 models) · Electrical Test Equipment

Four-Wire DC Low Resistance and Milliohm Meter

Bench four-wire DC resistance meters covering 0.01 µΩ to 2.4 GΩ across the group, with basic accuracy from 0.006% to 0.1%, test current to 10 A and three-level comparator sorting.

Test method
Four-terminal Kelvin, DC test signal
Widest range in the group
0.01 µΩ to 2.4 GΩ
Narrowest range in the group
10 µΩ to 20 kΩ
Basic accuracy
0.006% to 0.1% across the group
Front panel of the four-point probe meter, with the colour display showing sheet resistance in milliohms per square, resistivity and conductivity, and the function keys below the screen

SJ2663 (4 models) · Electrical Test Equipment

Four-Point Probe Sheet Resistance and Resistivity Tester

Four-point probe testers that read sheet resistance, resistivity and conductivity on wafers, films, coatings and bulk samples, with thickness preset and 3% sheet resistance accuracy.

Measured quantities
Sheet resistance, resistivity, conductivity and plain resistance, shown together
Probe geometry
Four in-line probes, 1 mm, 2 mm or 4 mm spacing depending on the head fitted
Resistance range
100 µΩ to 100 kΩ on the compact model; 1 µΩ to 100 MΩ on the widest
Sheet resistance accuracy
3% on three models; 4% on the low-resistance model; 5% above 2 MΩ
Benchtop insulation resistance meter in a grey case with a carrying handle, a colour screen at the left showing resistance and current readings above a row of soft keys, a numeric keypad at the right and three terminals labelled Input and Output below it

SJ2682A (6 models) · Insulation Resistance Testers

Programmable Digital Insulation Resistance Meter

Benchtop insulation resistance meter with programmable direct voltage from 0.5 V, resistance ranges to 100 PΩ on the top model, micro-current measurement from 0.1 fA and four-bin sorting.

Resistance range
10 kΩ to 1 TΩ on the entry model; 0.1 kΩ to 100 PΩ on the top model
Test voltage
Direct, 10 to 1000 V in 1 V steps, or 0.5 to 1000 V in 0.1 V steps by model
Current range
1 mA down to 0.01 pA, 0.01 nA, 0.01 pA or 0.1 fA by model
Resistance accuracy
±2% or ±3% below 1 GΩ, ±5% above 1 GΩ, ±10% above 1 TΩ
Front panel of the resistivity meter, with the colour display showing insulation resistance, volume resistivity and leakage current, and the function keys below the screen

SJ5013 (3 models) · Electrical Test Equipment

Volume and Surface Resistivity Meter for Insulating Materials

Programmable insulation testers that read volume resistivity, surface resistivity, insulation resistance and leakage current on rubber, film, fabric, powder and liquid specimens, up to 100 PΩ at 1000 V.

Measured quantities
Insulation resistance, volume resistivity, surface resistivity and leakage current, shown together
Resistance range
10 kΩ to 10 TΩ; to 100 PΩ or 1 PΩ on the two larger models
Current range
10 pA to 1 mA; 0.1 fA to 2 mA; 0.01 pA to 2 mA
Test voltage
0.5 to 1000 V DC, programmable
Conductor resistivity meter seen from the front, with a colour display showing resistance, resistivity and conductivity plus the entered diameter and length, a keypad at the right and four LD, LS, HS and HD terminals along the lower edge

SJ5511 (2 models) · Electrical Test Equipment

Cable and Wire Conductor Resistivity Tester

Four-terminal conductor testers that read resistance, resistivity and conductivity on wire and bar from 0.02 mm diameter, with 0.02% basic accuracy and up to 10 A test current.

Measured quantities
Resistance, resistivity and conductivity, shown together
Resistance range
0.1 µΩ to 10 MΩ; 0.01 µΩ to 10 MΩ on the larger model
Basic accuracy
0.02% on both models in the parameter table; 0.05% on one model card
Test current
≤1 A; ≤10 A on the larger model
Programmable withstand voltage and insulation tester shown from the front, with the two-line backlit LCD at the top left, the function keys below it and the high-voltage output terminals along the lower edge

SJ7110 (6 models) · Electrical Safety Testers

Programmable Withstand Voltage and Insulation Tester

Programmable safety tester range applying up to 5 kV AC or 6 kV DC, measuring leakage current against preset limits and insulation resistance to 50 GΩ, with arc detection and ten memory groups.

AC output
0.10 kV to 5.00 kV
DC output
0.10 kV to 6.00 kV, on five of the six models
Leakage current
0 to 12.00 mA AC and 0 to 5.00 mA DC as standard; 20 mA and 10 mA on the largest model
Insulation resistance
1 MΩ to 10 GΩ on the mid range; 0.1 MΩ to 50.0 GΩ on the two largest models
Benchtop electrical parameter meter in a pale case seen from the front, with a black display showing four stacked rows of red digits marked V, mA, W and PF, a column of small keys at the right of the screen and a four-way control with a central Enter key

SJ9800 (5 models) · Power Meters

Four-Window Digital Power and Electrical Parameter Meter

Benchtop electrical parameter meter with four LED windows showing voltage, current, power and power factor together, 0.5 class accuracy, automatic range switching and optional serial communication.

Display
Four windows, four-digit high-brightness LED
Input voltage
3 to 360 V AC on the selection table; 3 to 600 V on the parameter page, both carried
Input current
5 mA to 20 A on three models; 5 mA to 2 A on the two small-current models
Accuracy
0.5 class, as stated in the material
Benchtop digital multimeter in a grey housing, with a green vacuum fluorescent display showing two readings, a column of function keys down the centre of the panel and four input terminals on the right

TH1941 (6 models) · Digital Multimeters

Benchtop Digital Multimeter

Benchtop digital multimeter range in 4½, 5½ and 6½ digit models, with dual VFD or colour LCD displays, DCV to 1000 V, four-wire resistance and USB, GPIB or RS232 control.

Resolution grades
4½ digit at 21,000 or 51,000 counts; 5½ digit at 119,999 or 120,000 counts; 6½ digit at 1,199,999 counts
DC voltage
200 mV to 1000 V on TH1941; 500 mV to 1000 V on TH1942; 100 mV to 1000 V on the 5½ and 6½ digit models
AC voltage
200 mV to 750 V on TH1941; 500 mV to 750 V on TH1942; 100 mV to 750 V on the 5½ and 6½ digit models
Tightest one-year DCV uncertainty
0.02% of reading + 0.008% of range on TH1942
Bench capacitor leakage tester in a light grey case, with a backlit dot matrix display at the left showing a leakage current reading and charge status, function keys and a numeric keypad at the right, and a red high-voltage terminal beside two measurement terminals at the lower right

TH2689 (4 models) · LCR Meters

Capacitor Leakage Current Tester

Bench capacitor leakage testers with adjustable test voltage, leakage current measurement down to the nanoamp region, insulation resistance to 99.99 GΩ, timed charging and comparator limits.

Test voltage
1 V to 800 V on TH2689; 1 V to 500 V on TH2689A; 0 to 200 V and 0 to 500 V on TH2686N and TH2686C
Voltage accuracy
±(0.5% of setting + 0.2 V) on TH2689 and TH2689A; ±1% of setting + 1 digit on TH2686N
Leakage current range
0.001 µA to 20.00 mA on TH2689 and TH2689A; 10 nA to 19.99 mA with 1 nA resolution on TH2686N; 0 to 30 mA in 10 ranges on TH2686C
Insulation resistance
0.01 MΩ to 99.99 GΩ on TH2689 and TH2689A
Hand-held LCR meter with an orange and blue case, shown from the front with the backlit display at the top showing a secondary and a primary reading, eight keys and a power button below it, and a five-terminal test slot above three banana sockets at the bottom

TH2822A (4 models) · LCR Meters

Handheld LCR Meter

Four handheld LCR meters covering 100 Hz to 100 kHz, with 0.25% or 0.1% basic accuracy, a dual parameter backlit display, automatic range and Mini-USB control, for measuring inductors, capacitors and resistors away from the bench.

Test frequencies
100 Hz, 120 Hz, 1 kHz and 10 kHz; 100 kHz added on TH2822C and TH2822E
Basic accuracy
0.25% on TH2822A and TH2822C; 0.1% on TH2822D and TH2822E
Measured parameters
L, C, R and Z as primary, with D, Q, phase angle and ESR as secondary; DC resistance on TH2822D and TH2822E
Display ranges
L 0.00 µH to 1000.0 H; C 0.00 pF to 20.000 mF; Z and R 0.0000 Ω to 10.000 MΩ
Bench impulse winding tester in a light grey case, with a colour LCD at the left showing a damped oscillatory waveform and two readings below it, a column of four soft keys beside the screen, a keypad and three status keys at the right, and a USB socket at the far left

TH2882A-3 (3 models) · LCR Meters

Impulse Winding Tester

Impulse winding testers that apply a high-voltage pulse to a coil and compare the response waveform against a reference, for finding inter-turn shorts, weak insulation and winding faults in single-phase and three-phase parts.

Output pulse voltage
300 V to 3000 V ±5% in 50 V steps on TH2882A-3; 500 V to 5000 V ±5% in 100 V steps on TH2882A-5; the model list gives the same 500 V to 5000 V for TH2882AS-5
Pulse energy
≤90 millijoules on TH2882A-3; ≤250 millijoules on TH2882A-5 and, in the model list, on TH2882AS-5
Inductance range
≥10 µH on TH2882A-3; ≥20 µH on TH2882A-5; ≥200 µH on TH2882AS-5
Waveform sampling
≤40 MSPS at 8 bit
Programmable withstand voltage tester with a colour TFT display on the left of the front panel, a column of function keys beside it and the high-voltage output terminals below

TH9310 (6 models) · Electrical Safety Testers

TFT Display AC/DC Withstand Voltage and Insulation Tester

Programmable safety tester with a 480 by 272 TFT display, AC and DC withstand voltage to 6 kV, insulation resistance to 10 GΩ, twenty test files of twenty steps and arc detection.

AC output
0.05 kV to 5.00 kV, ±2%
DC output
0.05 kV to 6.00 kV, ±2%, on four of the six models
AC leakage current
0 to 10.00 mA; 1 µA to 20.00 mA on the higher-current model
Insulation resistance
0.1 MΩ to 10.0 GΩ at 0.10 kV to 1.00 kV
Benchtop oscilloscope in an ivory and grey case, with a blue trace on the display, five menu keys in a column beside the screen, vertical, horizontal and trigger control blocks to the right and two BNC inputs at the lower right

UTD2102CEX+ (3 models) · Electrical Test Equipment

Two-Channel Digital Storage Oscilloscope

Two-channel digital storage oscilloscope with 100 MHz bandwidth, 1 GSa/s sampling, 64 kpoint memory, a 7 inch display and recording of up to 1000 screens.

Bandwidth
100 MHz on UTD2102CEX+; 150 MHz on UTD2152S-E; 200 MHz on UTD2202CEX+
Channels
Two analog channels, with independent coupling settings
Sampling rate
1 GSa/s maximum
Memory depth
64 kpts
Wide benchtop AC source with a colour screen showing voltage, current, power and frequency at 220 volts and 50 hertz, a column of function keys, a rotary knob and a universal output socket at the right

YP4035 (7 models) · Electrical Test Equipment

Programmable AC Power Source

Programmable AC source from 350 VA to 10 kVA, with 45 to 400 Hz output, two voltage ranges, 2% distortion and RS-232 control for bench and line testing.

Capacity
350 VA to 10 kVA across seven models
Output voltage
1.0 to 150.0 V on the low range, 150.1 to 300.0 V on the high range
Frequency
45 to 400 Hz, 0.1 Hz steps, with 50, 60 and 400 Hz shortcut keys
Distortion
2% total harmonic distortion or less
Benchtop digital power meter in a pale case, front view with a wide black display showing four stacked numeric lines against the A, B, C and D channel labels, and a keypad with a rotary confirm control to the right of the display

YP9901 (3 models) · Power Meters

Single-Phase Digital Power Meter

Panel digital power meter reading voltage, current, active power, power factor, frequency, apparent and reactive power in four windows at once, with an RS232 Modbus RTU port as standard and current ratings from 20 A to 200 A.

Basic accuracy
±0.2 % (0.2 class)
Measurement mode
AC on the AC series; AC, DC and RMS on the AC/DC series
Voltage input
3 to 600 V AC; 3 to 600 V AC + DC on the AC/DC series
Current ranges
5 mA to 20 A up to 50 mA to 200 A, according to series and rating
Benchtop safety tester seen from the front, with three push buttons at the left, a colour touch screen in the centre, a pair of test terminals to its right and a universal output socket at the far right

YP9950 (3 models) · Electrical Safety Testers

Five-in-One Electrical Safety Performance Tester

Touch screen safety performance tester combining withstand, ground bond, insulation, leakage and electrical parameter measurement in one sequence, in three configurations.

AC withstand
300 to 5000 V, leakage 0.100 to 20.00 mA
Ground bond
AC 3 to 32 A, 0 to 600 mΩ, four-wire
Insulation resistance
DC 200 to 1000 V, 0.1 to 2000 MΩ
Leakage current
Static or dynamic, 0.000 to 20 mA
Bench instrument seen from the front, with a colour display showing a decaying waveform trace across a graticule at the left, a column of soft keys beside it, a keypad and arrow pad at the right, and four high-voltage terminals with a ground terminal along the lower edge

ZX1373X-12A (3 models) · LCR Meters

High-Frequency LCR Bridge with DC Bias Current Source

Bias bridge instruments combining a high-frequency LCR meter with a 0 to 12 A or 0 to 25 A DC current source, with 0.25 mA current steps, sweeps up to 3600 s and stackable slaves to 225 A.

Bias current
0 to 12 A, 0 to 25 A, or up to 225 A with eight slaves stacked
Current resolution
0.25 mA on the lowest range
Maximum output voltage
11 V at every current setting
Bridge frequency
50 Hz to 200 kHz as standard; to 1 MHz or 2 MHz on the wide-band models
Battery tester seen from the front, with a colour display showing 6.008 mΩ and 3.89007 V at the left, a numeric keypad at the right and four source and sense terminals along the lower edge

ZX5560B (5 models) · Electrical Test Equipment

Battery Internal Resistance and Voltage Tester

Four-terminal battery testers that read internal resistance and terminal voltage together, from 0.1 µΩ to 3.1 kΩ and up to 1500 V DC, with bin sorting and handler output.

Measurement
AC internal resistance and DC terminal voltage, shown together
Test method
Four-terminal measurement with a 1 kHz alternating current
Resistance range
3 mΩ to 3 kΩ on most models; 0.1 µΩ to 3.1 kΩ on the high-voltage models
Voltage range
60 V, 300 V, 600 V, 1000 V or 1500 V DC, depending on model
Bench instrument seen from the front, with a colour LCD showing a waveform trace across a graticule at the left, a column of soft keys beside it, a keypad and rotary controls at the right, and four high-voltage terminals with a ground terminal along the lower edge

ZX70A-200K (4 models) · LCR Meters

Impedance Analyzer for Piezoelectric and Ultrasonic Devices

Bench impedance analyzers covering 20 Hz to 5 MHz for piezoelectric ceramics, crystals and ultrasonic transducers, with four-wire Kelvin ports, frequency sweeps and a three-level comparator.

Frequency range
20 Hz to 200 kHz, 500 kHz, 1 MHz, 2 MHz or 5 MHz, by model
Basic accuracy
0.05% on the 200 kHz and 500 kHz models; 0.1% on the 1 MHz, 2 MHz and 5 MHz models
Frequency resolution
1 mHz
Impedance range
0.01 mΩ to 99.99 MΩ
Bench LCR meter seen from a low front-left angle, with a blue LCD at the left showing resistance and reactance readings, a column of soft keys beside it, an arrow pad and keypad at the right, and four BNC terminals along the lower edge

ZX8510BN (5 models) · LCR Meters

Compact LCR Digital Bridge with Fixed Frequency Points

Compact bench LCR bridges with four to ten test frequencies up to 100 kHz, basic accuracy from 0.2% to 0.05%, four-wire Kelvin terminals and three or four-bin sorting.

Test frequency
Four, six or ten fixed points between 50 Hz and 100 kHz, by model
Basic accuracy
0.2% on ZX8511DN; 0.1% on ZX8510BN, ZX8510BT and ZX8517BN; 0.05% or 0.1% on ZX8517BT depending on the table
Test level
0.1 V, 0.3 V or 1 V rms on the three-level models; 0.1 V to 2 V on the wide-level models
Impedance range
0.1 mΩ to 99.999 MΩ on the compact models; 0.01 mΩ to 99.9999 MΩ on the wide-level models
Bench instrument seen from the front left, with a colour display showing four measured parameters and their limits, a block of function keys and a numeric keypad at the right, and three coaxial connectors along the lower right edge

ZX8816 · LCR Meters

Low-Inductance Pulse Coil Tester

Pulse winding tester for coils from 0.1 µH to 1 mH, with four-terminal sensing, voltage compensation, breakdown voltage analysis, a 200 MHz sampler and a fastest test time of 18 ms.

Inductance range
0.1 µH to 1 mH
Peak test voltage
10 V to 1000 V
Voltage accuracy
±(1% of setting + 2.0 V)
Sampling
10 bits at 200 MHz, eight rate settings
Benchtop high voltage tester seen from the front, with a green segmented readout across the upper right, a large rotary knob at the left, a row of keys with a red stop button below it and a high voltage terminal at the lower right

ZX9320SA-2 (4 models) · Electrical Safety Testers

Multi-Channel Withstand and Insulation Tester

Compact scanning safety tester with two, four or eight channels, AC and DC withstand, insulation resistance to 50 GΩ and nine-level arc detection.

Channels
Two, four or eight depending on model
AC output
0.05 to 5.00 kV, ±2%
DC output
0.05 to 6.00 kV, ±2%, not fitted to AC-only models
Leakage current
AC 0 to 10.00 mA; DC 0 to 10.00 mA on the four-channel model
Portable surface roughness tester in a grey and black body lying at an angle, with a yellow backlit display reading 1.600 um against a Ra line and a sampling-length line, and six control keys marked with a red START key, arrow keys, an ESC key and a power key

GH880 (2 models) · Surface Roughness Testers

Portable Surface Roughness Tester

Portable surface roughness tester reading Ra and Rz with up to 26 parameters, eight built-in standard editions and four interchangeable sensors for bores, grooves and curved surfaces.

Model
GH880 / TR100
Principle
Inductive pickup with a diamond stylus and a guide shoe
Measuring range
Ra and Rq from 0.005 to 32 µm; Rz, Ry, Rt, Rp and Rm from 0.02 to 320 µm; display range ±160 µm
Resolution
0.001 µm on the GH880; 0.01 µm on the TR100
Bench torque wrench calibrator with an orange body, a blue control panel carrying a red numeric display and a keypad at the left, a horizontal load beam across the top with a mounted wrench and a black handwheel at the right

HB-10N (6 models) · Material Testing Machines

Torque Wrench Calibrator

Bench calibrator for torque wrenches from 1 to 5000 N·m, with a lever loading arm, height and length adjustment, peak hold and an RS232 link.

Range
1.00 to 10.00 N·m up to 500 to 5000 N·m, in twelve single-range sizes
Accuracy
±1.0%
Measurement modes
TRACK and PEAK
Units
N·m, kgf·cm and lbf·in
White display unit with a two-row liquid crystal display and a grid of coloured keys on the left, joined by a coiled cable with blue connectors to a black cylindrical detector head fitted with a hex bit

HDP-5 (4 models) · Material Testing Machines

Screw Torque Tester with Detector Head

Screw torque tester with a cable-connected detector head, for checking the torque of screws already tightened, with peak hold, averaging and stored readings.

Torque range
0.015 to 0.500 N·m and 0.15 to 5.00 N·m, two sizes each in two variants
Accuracy
±1.0% with three digits, inside the lower tenth of the range
Measurement modes
TRACK and PEAK
Direction
Clockwise and counter-clockwise, shown on the display
Front panel of a torque meter with a three-and-a-half digit liquid crystal display at the upper left, a zero-adjust knob, capacity and mode selector switches in the middle and a square drive socket on the right

HIT-10000S (3 models) · Material Testing Machines

Split-Type Impact Torque Tester

Split-type impact torque tester for powered wrenches and hammers, with a separate transducer, TRACK, PEAK and PPEAK modes and three large-capacity sizes on a colour touch display.

Torque range
100 to 1000 N·m, 200 to 2000 N·m and 300 to 3000 N·m, one per size
Accuracy
±1.0%
Measurement modes
TRACK, PEAK and PPEAK
Units
N·m, kgf·cm and lbf·in
Front panel of a yellow torque meter with a three-and-a-half digit liquid crystal display at the upper left, a power rocker and a round reset button on the left, capacity and mode selector switches in the middle and a square drive socket on the right

HP-10S (5 models) · Material Testing Machines

Electric Screwdriver Torque Tester

Bench torque tester for setting the clutch of electric screwdrivers, with five ranges, three units, ten stored readings, peak hold and an RS232 link.

Torque range
0.015 to 20.00 N·m across five sizes
Accuracy
±0.5% of reading ±3 digits on four sizes; ±1.0% on the largest
Measurement modes
TRACK and PEAK
Units
N·m, kgf·cm and lbf·in
Bench closure torque tester with a yellow housing, a sloped control panel at the left, a horizontal slide carrying two upright brass chucks in the middle and a handwheel at the right

HT-10A (4 models) · Material Testing Machines

Bottle Cap Torque Tester

Bench closure torque tester with adjustable chucks, upright or inverted clamping, four ranges and peak hold for cap tightening and opening force.

Torque range
0.015 to 20.00 N·m across four sizes
Accuracy
±0.5% within 10% of range ±3 digits; ±1.0% on the largest size
Measurement modes
TRACK and PEAK
Units
N·m, kgf·cm and lbf·in
Handheld coating thickness gauge with a light grey front panel, a display showing a thickness reading above four statistics columns and a substrate indicator, and four round keys beneath the screen

LS225 (4 models) · Coating Thickness Gauges

High-Precision Coating Thickness Gauge

Coating thickness gauge with interchangeable magnetic and eddy current probes, five-point calibration and an accuracy of ±(2% of reading + 0.3 µm) for plating and paint on small parts.

Measuring range
0.0 to 500 µm with F500; 0.0 to 1500 µm with N1500; 0.0 to 2000 µm with N2000
Accuracy
±(2% H + 0.3 µm) after five-point calibration, H being the standard value
Repeatability
≤ (0.8% H + 0.1 µm) on F500 and N1500 with the hand press stand; ≤ ±(1% H + 0.2 µm) on N2000
Probes
F500 magnetic induction; N1500 and N2000 eddy current
Yellow handheld coating thickness gauge with a red backlit display in a dark bezel, a single round key below the screen and a narrow probe barrel at the lower end

LS238 (5 models) · Coating Thickness Gauges

Handheld Automotive Paint Thickness Gauge

Handheld paint thickness gauge with a 3500 µm range, automatic recognition of steel, galvanised steel, aluminium and plastic substrates, and a putty detection warning for used-car inspection.

Measuring range
0.0 to 3500 µm
Resolution
0.1 µm from 0 to 99.9 µm; 1 µm from 100 to 3500 µm
Accuracy
≤ ±(3% H + 2 µm), where H is the standard value
Substrates
Ferrous by Hall effect; non-ferrous by eddy current; identified automatically
Portable Leeb hardness tester in a black sealed housing with a 128 by 64 LCD reading 46.6 HRC above a material line and a measurement counter, a twelve-key control pad with coloured keys, a yellow coiled cable to a separate impact device standing on a cylindrical test block beside it

TH100 (4 models) · Hardness Testers

Portable Leeb Hardness Tester

Portable Leeb hardness tester reading HL and converting to HB, HRC, HRB, HRA, HV and HS in one key, with a D impact device, 360° measurement and ten built-in materials.

Model
TH100 / TH110 / TH120 / TH140
Hardness scales
HL, HB, HRC, HRB, HRA, HV and HS, converted on the instrument
Measuring range
170 to 960 HLD, 17.9 to 69.5 HRC, 19 to 683 HB, 80 to 1042 HV, 30.6 to 102.6 HS
Impact device
D type supplied as standard; DC, DL, D+15, C, G and E types available to order
Split-probe coating thickness gauge in a black housing with a cable entering the top, a backlit display reading 49.4 um above a line showing the probe type and single measurement mode, and a twelve-key control pad below with eight keys grouped in coloured pairs and a round key in the centre

TT220 (3 models) · Coating Thickness Gauges

Dual-Principle Coating Thickness Gauge

Magnetic and eddy current coating thickness gauge measuring 0 to 1250 µm on steel and aluminium, with automatic probe identification, statistics, limit alarms and 500 stored readings.

Model
TT220 / TT230 / TT260 and the split-probe F and N series
Measuring principle
Magnetic induction on ferromagnetic substrates, eddy current on non-ferrous substrates, selected automatically by the probe fitted
Measuring range
0 to 1250 µm with the standard F1 or N1 probe; 0 to 400 µm with F400; 0 to 5000 µm with F5; 0 to 10000 µm with F10; 0 to 2000 µm on the integral TT220
Resolution
0.1 µm below 100 µm; 10 µm on the long-range F10 probe; 1 µm above 100 µm on the integral model
Portable ultrasonic thickness gauge in a black housing standing on a machined metal block in a workshop, its display reading 0.94 mm with a velocity line above it, a twelve-key control pad below showing eight colours of keys, a printed line reading ultrasonic thickness gauge, and a white-gloved hand holding the probe against the block

JITAI-510 (4 models) · Ultrasonic Thickness Gauges

Portable Ultrasonic Thickness Gauge

Portable ultrasonic thickness gauge covering 0.8 to 600 mm, with through-coating, ultra-thin and electromagnetic variants down to 0.15 mm and 0.001 mm resolution.

Model
JITAI-510 / JITAI-515 / JITAI-512 / JITAI-514
Measuring range
0.8 to 600 mm on the JITAI-510 depending on probe; 1 to 300 mm for the through-coating model; 0.15 to 300 mm on the ultra-thin model; 0.75 to 160 mm on the electromagnetic model
Resolution
0.01 mm on the JITAI-510, 515 and 514; 0.001 mm on the JITAI-512
Accuracy
±0.05 mm between 0.8 and 10 mm and ±(0.01 + H/200) mm above 10 mm on the JITAI-510, where H is the measured thickness
Digital ultrasonic flaw detector in a light grey housing with a large display showing an A-scan trace against a distance grid above a data panel listing gain, step, material, delay, zero, gate mode, average and reject values, a rotary knob and eleven control keys on the left, and five function keys marked BASE, CAL, DAC, AVG and SYS along the bottom

KUT350 (4 models) · Ultrasonic Testing Equipment

Digital Ultrasonic Flaw Detector

Digital ultrasonic flaw detector with 150 to 800 MHz sampling, DAC and AVG curves, 500 inspection channels and U-disk storage on the upper models, for weld, forging and plate inspection.

Model
KUT350 / KY880S / KY990S / KY9901PLUS
Sampling frequency
150 MHz / 200 MHz / 320 MHz / 800 MHz respectively
Scanning range
0 to 10000 mm on the KUT350; 0 to 6000 mm on the KY880S; 15 to 10000 mm on the KY990S; up to 15000 mm on the KY9901PLUS
Sound velocity
1000 to 15000 m/s on the KUT350 as the card figure, with 100 to 20000 m/s also printed on the same page; 100 to 15000 m/s and 100 to 20000 m/s on the upper models
Portable magnetic particle inspection yoke with a yellow and black body and a silver laminated pole piece, a coiled supply cable running to a separate black rectangular battery pack standing upright beside it

KY-CJE220 Series (3 models) · Magnetic Particle Testing Equipment

Portable Magnetic Particle Inspection Yoke

Portable magnetic particle inspection yoke with AC, DC and inverter power packs, white or ultraviolet illumination, and a 0 to 220 mm magnetising pole spacing, with a bench unit for small parts.

Model
KY-CJE220 series, Y series and the CDX-III bench unit
Magnetising pole spacing
0 to 220 mm on the portable range; 0 to 160 mm, 0 to 255 mm, 100 mm and Φ120 mm across the four bench probes
Detectable depth
3 mm below the surface on AC supply alone; 5 mm on the variants carrying a DC or inverter power pack
Lifting force
AC 45 N or better on the direct-supply yokes; AC 69 N and DC 215 N on the inverter model; the material also states AC 69 N and DC 215 N for the Y series
A stainless steel digital caliper with the jaws open, a large liquid crystal display showing a millimetre reading, and a thumb roller and function keys on the sliding frame

Digital Calipers

Digital Vernier Caliper

Digital vernier caliper in 150, 200 and 300 mm ranges with a 0.01 mm display, metric and inch switching, zero at any position, and an IP54 version for wet or dusty work.

Range
0 to 150 mm, 0 to 200 mm and 0 to 300 mm
Resolution
0.01 mm, displayed directly
Accuracy
Stated as plus or minus 0.03 mm
Display
Liquid crystal with LED backlight; 1.5 inch on the classic version and 2.2 inch on the large-screen version
Two mechanical dial indicators side by side on a plain surface, the smaller with a yellow dial and a short measuring stem, the larger with a white dial, a revolution counter and a longer stem

Dial Indicators

Mechanical Dial Indicator

Mechanical dial indicator and dial gauge for comparative measurement, in 0.01 mm and 0.001 mm graduations with dial diameters from 42 to 80 mm.

Types
A mechanical dial indicator resolving to 0.01 mm and a dial gauge resolving to 0.001 mm
Dial indicator ranges
0 to 3, 0 to 5, 0 to 10, 0 to 20, 0 to 30 and 0 to 50 mm
Dial gauge ranges
0 to 1, 0 to 3 and 0 to 5 mm
Graduation
0.01 mm on the dial indicators and 0.001 mm on the dial gauges
Digital outside micrometer, 25-50 mm, with its 25 mm setting rod, spanner and spare measuring faces

Micrometers

Outside Micrometer

Outside micrometers in two grades: digital styles reading to 0.001 mm, and mechanical styles from 0-25 to 225-250 mm, both with carbide measuring faces and a ratchet stop.

Resolution
0.001 mm digital / 0.01 mm mechanical
Tolerance
±0.002 mm digital / ±0.02 mm mechanical
Digital ranges
0-25, 25-50, 50-75, 75-100 mm
Mechanical ranges
0-25 to 225-250 mm, in 25 mm steps

Sensors, Control & Data

The component and system layer: bare sensing elements, PLC and Modbus devices, signal conditioning, and the acquisition hardware and software that log a process over time.

14 · AVAILABLE

Industrial Sensors

Bare sensing elements and transducer components - pressure, temperature, proximity, photoelectric, position and current sensors.

18 product types: Pressure Sensors · Temperature Sensors · Flow Sensors · Level Sensors · Proximity Sensors · Photoelectric Sensors · Position Sensors · Displacement Sensors · Speed Sensors · Vibration Sensors · Force Sensors · Load Cells · Torque Sensors · Humidity Sensors · Gas Sensors · Current Sensors · Voltage Sensors · Other Industrial Sensors

Open the industrial sensors hub →
M12 threaded inductive proximity switch with a blue sensing face, lock nuts and a cable

LJ12A3 · Proximity Sensors

Inductive Proximity Switch, M12

M12 inductive proximity switches for non-contact metal detection, in shielded 2 mm and unshielded 4 mm versions with NPN, PNP, two-wire DC and two-wire AC outputs.

Thread
M12×1
Sensing distance
2 mm ±10% shielded; 4 mm ±10% unshielded
Setting distance
0 to 1.6 mm shielded; 0 to 3.6 mm unshielded
Standard target
Iron, 12×12×1 mm shielded; 15×15×1 mm unshielded
Rectangular photoelectric sensor with a red lens window, a green adjustment knob and a black output cable

PG6 · Photoelectric Sensors

Photoelectric Sensor with Background Suppression

Photoelectric sensors with background suppression, in diffuse, through-beam and retro-reflective forms, sensing from 100 mm to 15 m with a 1 ms response and IP67 sealing.

Sensing forms
Diffuse with background suppression, through-beam, retro-reflective
Sensing ranges
100, 300, 500 and 900 mm diffuse; 125 mm line-beam; 15 m through-beam; 6 m retro-reflective
Supply
12 to 24 VDC ±10%, ripple 10% peak-to-peak or less
Output
NPN or PNP open collector, 100 mA maximum
Stainless steel pressure transmitter with a plug connector on top, a hex body and a threaded pressure port

TFD-801 · Pressure Sensors

Diffusion Silicon Pressure Transmitter

Diffusion silicon pressure transmitters with a 304 stainless steel body, IP65 sealing and ranges from -100 kPa to 100 MPa, in two-wire 4-20 mA and three-wire voltage forms.

Pressure ranges
-100 kPa to 100 MPa across the series
Pressure types
Gauge, absolute and sealed gauge
Accuracy
0.2%FS on the stocked ranges; a 0.5% grade is listed for the series
Output
4-20 mA two-wire as standard; 0-5 V, 0-10 V or RS-485 to order
Grey DIN-rail AC voltage transmitter with a screw terminal block and a label reading AC 0-400V input and 4-20 mA output

Signal Converters

AC Current and Voltage Transducer

A DIN-rail current and voltage transducer for AC or DC circuits, with 4-20 mA, 0-10 V, RS-485 or CAN output, split-core and through-bore inputs to 3000 A, and 0.2 to 0.5 class accuracy.

Input
AC current from 0-5 A to 0-3000 A, AC voltage to 500 V, DC current and voltage, with split-core and through-bore forms
Output
4-20 mA, 0-20 mA, 0-10 V, 0-5 V, RS-485/Modbus or CAN
Accuracy
0.2, 0.3 or 0.5 class, with plus or minus 0.1 % and 0.2 % of full scale on some forms
Supply
24 V DC, 220 V AC or 12 V DC depending on the form
Panel-mount PID temperature controller with a red process value display, a green setpoint display and four setting keys

PID Controllers

Panel-Mount PID Temperature Controller

Panel-mount PID temperature controllers in four panel sizes, taking thermocouple, RTD, 4-20 mA or 0-10 V inputs and driving relay, SSR, linear and RS-485 outputs.

Panel sizes
48×48, 48×96, 72×72, 96×96 mm
Input types
K, E, J, R, S, B, N, T, PT, CU; 4-20 mA; 0-10 V
Default input
Type K, changeable in the menu
Output forms
Relay, SSR drive, PID 4-20 mA or 0-10 V, linear 0-10 V or 4-20 mA
PLC and HMI all-in-one controller showing a process diagram on its touch screen, with status lamps beside the display

AMX-HM · PLC Systems

PLC and HMI All-in-One Controller

Programmable logic controllers with an integrated touch screen, in 4.3, 7 and 10 inch formats, combining discrete and analogue I/O, PT100 inputs, high-speed counting and relay outputs in one panel unit.

Screen sizes
4.3, 7 and 10 inch
Discrete inputs
8, 16 or 24, depending on model
Discrete outputs
8, 16 or 22, depending on model
Analogue I/O
4 inputs and 2 outputs on the models that carry them
Four slim DIN-rail signal isolator modules standing side by side, each with pluggable terminals on the top face

M2 · Signal Isolators

DIN-Rail Signal Isolator

DIN-rail signal isolators and distributors giving 2000 Vrms isolation between input, output and supply, with 0.1%FS transmission accuracy and 10 ms response.

Isolation
2000 Vrms for 1 min, no flashover, between input, output and supply
Insulation resistance
100 MΩ minimum at 500 VDC
Transmission accuracy
0.1%FS at 20°C
Temperature drift
0.0075%FS/°C
A small green circuit board carrying a shielded wireless module, a row of connections along each side, a card socket at one end and a connector for an external antenna

ESPC3-20 (2 models) · Wireless Data Loggers

Wireless Serial Data Logger

Two-port wireless serial data logger that records equipment traffic to a TF card and serves live and historical logs over Wi-Fi, with UDP and MQTT reporting.

Model
ESPC3-20 / N4, hardware version V2.3
Serial ports
Two, with baud rates from 4,800 to 3,000,000, configurable
Wireless
Wi-Fi, with client, access-point and radio-off modes
Storage
A TF card, with the free capacity shown; the module can also run without a card
Black panel-mount paperless recorder shown at an angle, with a colour screen displaying six channels as coloured numeric values in two columns with units beside each reading, a column of round keys and a USB socket to the right of the screen, and louvres moulded into the side of the case

MIK-R200T (4 models) · Industrial Data Loggers

Paperless Data Recorder

Panel-mount paperless recorders in four model ranges, from 6 to 48 input channels, accepting current, voltage, resistance thermometer and thermocouple signals directly and storing the record in internal flash memory.

Model ranges
MIK-R200T, MIK-R5000C, MIK-R6000C and MIK-RN3000
Input channels
1 to 6 on MIK-R200T, 1 to 12 on MIK-R5000C, 1 to 48 on MIK-R6000C, 1 to 18 on MIK-RN3000
Sampling period
1 s, one sample per channel every second
Input types
Current, millivolt, voltage, resistance thermometer, thermocouple and linear resistance, by model

Laboratory & Calibration

General laboratory equipment and the reference-grade instruments, calibrators and test pumps used to establish and maintain traceability of every measurement above.

17 · AVAILABLE

Laboratory Instruments

Balances, pH and conductivity meters, centrifuges, ovens, furnaces, incubators, water baths and microscopes.

14 product types: Laboratory Balances · Analytical Balances · pH Meters · Conductivity Meters · Laboratory Centrifuges · Laboratory Ovens · Laboratory Furnaces · Laboratory Incubators · Laboratory Shakers · Laboratory Mixers · Water Baths · Laboratory Microscopes · Refractometers · Laboratory Equipment

Open the laboratory instruments hub →
A bench-top electric drying oven with its door closed, showing a double glazed viewing window, a rotary latch, and a control panel at the left with a two-line digital display, indicator lamps and a green mains switch

101-0A (13 models) · Laboratory Ovens

Electric Drying Oven

Electric drying oven with a chamber from 16 to 1000 litres, a working range from 5 degrees above ambient to 250 degrees Celsius, a galvanised or stainless-steel interior, forced air circulation on most models and a timed digital controller.

Temperature range
5 degrees above ambient to 250 degrees Celsius, with a stated ultimate limit of 300 degrees Celsius
Chamber volumes
16, 43, 70, 136, 225, 640 and 1000 litres
Interior
Galvanised steel on the A versions and stainless steel on the B versions; the two are the same size in the same volume
Convection
Bottom heating with an adjustable blower on the desktop range apart from the 202-0 pair; rear heating with a rear blower on the vertical range, twin blowers at 640 litres
An inverted metallurgical microscope in black and white, with a trinocular viewing head at the left, the objective turret mounted beneath a large square mechanical stage, coarse and fine focus controls on the body and a bright field illuminator at the rear

4XC (13 models) · Laboratory Microscopes

Metallurgical Microscope

Metallurgical microscope for reflected-light examination of metals and other opaque specimens, in inverted and upright stands with long working distance objectives, a trinocular camera port and optional image analysis software.

Structures
Inverted, where the objective sits below a stage that carries the specimen, and upright, where the objective looks down onto it
Observation head
Trinocular, inclined at 45 degrees, with an interpupillary adjustment from 48 to 75 mm, a plus or minus 5 dioptre correction and a stated 40:60 split between the eyepieces and the camera port
Eyepieces
High eye point wide field plano eyepieces, 10x, with a field number of 18, 20 or 22 mm depending on the model
Objectives
Long working distance plan achromatic objectives at 5x, 10x, 20x, 50x and 100x depending on the model, with a long working distance plan set stated at numerical apertures of 0.13, 0.25, 0.40 and 0.65
Mechanical double pan balance with a dark green painted base, two white moulded pans on a polished beam and linkage above them, a black printed rider scale running along the beam and marked to 5 g, and a graduated set of cylindrical metal weights with a pair of tweezers laid out in front

JPT-01 (6 models) · Laboratory Balances

Mechanical Pan Balance

Mechanical double pan balances in six capacities from 100 g to 5000 g, each supplied with its own weight set and tweezers, reading by lever and rider with no supply, no calibration routine and no data output.

Capacities
100 g, 200 g, 500 g, 1000 g, 2000 g and 5000 g across six models
Readability
0.1 g, 0.2 g, 0.5 g, 1 g, 2 g and 5 g by capacity, matching the verification scale interval on every model
Pan diameter
85 mm on the 100 g and 200 g models, then 115 mm, 140 mm, 170 mm and 205 mm as capacity rises
Method
Lever and Roberval mechanism with external weights and a sliding rider; no electronics, no supply and no calibration routine
Hand-held pen shaped pH meter with a light grey body, a dark grey cap at the top and a tapered probe at the foot, its display showing 7.49 pH above a reading of 30.1 degrees Celsius, with three buttons below the screen

PH848 (5 models) · pH Meters

Pen Type pH Meter

Pen type pH meters in five models across two accuracy grades, with the electrode and the display in one hand-held body, automatic temperature compensation and a selectable probe form.

Models
PH848, PH838, PH818, PH828 and PH828+ across two accuracy grades
pH range
0.0~14.0 on PH848; 0.00~14.00 on PH838, PH818, PH828 and PH828+
Resolution and accuracy
0.1 resolution at ±0.1 pH on PH848; 0.01 resolution at ±0.05 pH on the other four
Repeatability
0.1 on PH848; 0.03 on the other four
Yellow rectangular water tank with an aluminium pump body on top, a chrome lever with a black grip, a small pressure gauge, a red relief knob and a coiled orange hose

Pressure Test Pumps

Manual Pressure Test Pump

Hand-operated hydrostatic test pump with an 18 litre tank, a brass check valve and a reinforced hose, used to pressure-test water pipe, underfloor heating loops and plumbing installations.

Application
Pressure testing of PPR water pipe, mains pipe, underfloor heating loops and plumbing installations
Gauge fitted
25 MPa on the standard version; a 7 MPa oil gauge on the upgraded version; 40 or 60 MPa on the enlarged version
Tank
18 litres, iron, 1.35 mm wall, sprayed finish, 300 × 200 × 90 mm
Pump body
Aluminium; thickened on the upgraded and enlarged versions
A handheld calibrator in a black and grey body with a colour screen showing an output value, a measurement value and two trend traces, with coloured test leads above it and a row of function keys below

OHR-C01 (3 models) · Temperature Calibrators

Handheld Temperature Calibrator

Handheld temperature calibrator that measures and sources thermocouple and resistance signals, with cold-junction compensation, step or ramp output and a colour trend display.

Models
A process loop version, a temperature-only version, and a multifunction version covering both
Thermocouple types
S, B, E, K, R, J, T and N, each with its own range and accuracy
Resistance elements
Pt100 and Cu50
Resistance ranges
0 to 400 ohm, 0 to 1,000 ohm and 0 to 10 kilo-ohm
Silver metal calibrator with a green LCD window above a row of membrane keys, a carrying handle, two large knurled knobs on the body and a transparent water cup on top

YPR-YBS-WY · Pressure Calibrators

Portable Pressure Calibrator

Battery-powered pressure calibrator with an integral hand pump, a 24 VDC loop supply and simultaneous pressure and current display, covering vacuum to 60 MPa including hydraulic ranges.

Pressure ranges
-95 kPa to 250 kPa; 0-1.6 MPa; 0-2.5 MPa; -95 kPa to 2.5 MPa; 0-4 MPa
Hydraulic ranges
0-16, 0-25, 0-40 and 0-60 MPa with the supplied water cup
Accuracy
0.05 grade basic; pressure 0.1%FS and 0.05%FS; current 0.05% ±1 digit
Resolution
10 Pa minimum pneumatically; 1 kPa minimum on the hydraulic ranges; 1 µA on current

How classification works

One product, one primary category

A catalogue is only navigable if the same instrument does not appear in two places. These are the rules this one is built on, and the reason a product can be found by following a single path.

Why it matters to you

A product listed in two categories competes with itself in search results and forces you to compare two pages for the same instrument. Every item in this catalogue therefore has exactly one primary category, and where a product type genuinely sits on a boundary we decide it once and link across rather than duplicating the page.

The same principle applies to how a product is reached from the rest of the site: an instrument is reachable from its category, from the applications it serves and from the industries that specify it, but it is only ever written once.

Boundaries we apply

  • Online and in-line process analysis stays in Process Analysis; laboratory and offline analysis goes to Analytical Instruments.
  • Single-instrument devices sit in Process Instrumentation; PLC, I/O and communication hardware sits in Industrial Automation.
  • Bare sensing elements are Industrial Sensors; the same element packaged as a meter with a display and standard output belongs to the corresponding Measurement category.
  • Test and diagnostic instruments are Electrical Test & Measurement; instruments that source a known value for comparison are Calibration & Metrology.
  • Method-based inspection (UT, ET, MT, PT, RT) is Non-Destructive Testing; mechanical and physical testing is Industrial Testing Equipment.

Cannot find the category you need?

Send the requirement and we will confirm whether it sits in a category shown here or needs a new one. Minimum order quantity is 1 pc, and an enquiry costs nothing.

Request a Quote WhatsApp