A light meter, or lux meter, measures illuminance: the amount of visible light arriving at a surface, expressed in lux or in foot-candles. It is the instrument behind a lighting survey, a workplace check and a visit to a room that is too dim or too bright, and it reports a figure where the eye cannot, which is the point, because the eye adapts and the requirement does not.

What a light meter is

A light meter, or lux meter, measures illuminance: the amount of visible light arriving at a surface, expressed in lux or in foot-candles. It is the instrument behind a lighting survey, a workplace check and a visit to a room that is too dim or too bright, and it reports a figure where the eye cannot, which is the point, because the eye adapts and the requirement does not.

The number is defined on a surface rather than in a direction, so how the sensor is held is part of the measurement. A sensor facing the ceiling in a room lit from the side reads something quite different from the same sensor held towards the task, and a reading taken at the wrong plane is not a fault of the instrument but of the survey. Most instruments settle this with a diffuser over the detector and with a sensor that can be angled or detached.

The type divides on how far the sensor has to travel and how much light has to be covered. An instrument with a fixed head is convenient and cannot reach into the space above a machine; one with a lead and a separate probe can be placed where the work happens and read from where the operator stands. At the same time the range has to stretch from the few lux of an emergency-lit corridor to the tens of thousands under daylight, and that span, rather than the resolution, is what separates the models.

How a light meter measures

The sensing element is a photodiode, normally silicon, whose output current is proportional to the light falling on it. On its own the element responds to a wider band than the eye does, including the near infrared, so a filter is placed over it to bring the overall response close to the curve that defines the lux. How close that match is decides whether a warm white source and a cool white source at the same true illuminance read as the same figure.

The measured current spans several decades between a dim corridor and direct daylight, so the instrument switches ranges or applies a scaling factor. On many models the display shows the significant figures only, with the multiplier indicated separately: a reading of 1455 beside a multiplication marker of one hundred means 145500 lux, and reading the digits alone is a large and common error. The multiplier is part of the measurement rather than an annotation.

The rest of the specification follows the same logic. Response time decides whether a reading settles before the surveyor moves on; the response as the sensor tilts away from the source falls off in a defined way, which is correct, because a surface really does receive less light at an angle; and a temperature channel, where present, is a separate sensor sharing the housing rather than a correction applied to the light reading.

Configuration choices

Most of the specification is fixed by these decisions rather than by the accuracy class. Each one constrains the next, which is why they are settled in order.

ConfigurationOptions to fixWhat it actually decides
Sensor mounting A sensor fixed in the body, or a sensor on a lead that can be placed separatelyWhether the measurement can be taken where the work is rather than where the surveyor can stand. For anything beyond a desk survey this is the most consequential choice on the list.
Range and scaling From a few lux up to tens or hundreds of thousands, with automatic or manual range changing and a displayed multiplierWhether one instrument covers an emergency-lit stair and daylight through a window. The multiplier has to be read with the digits, not instead of them.
Spectral response An unfiltered element, or one filtered towards the response of the eyeWhether different light sources at the same true illuminance read as the same figure. It matters most with white LEDs, which concentrate much of their output in a narrow blue band.
Sensor geometry A diffuser that corrects for the angle of incidence, and whether the head rotates or detachesWhether an angled reading is corrected or simply lost. A head that cannot be turned forces the surveyor to estimate the plane of measurement.
Unit selection Lux, foot-candles, or both on one instrumentWhether the reading can be compared directly with the requirement being applied. One is a metric unit and one is not, and the conversion is not a rounding.
Additional channel Light only, or light and ambient temperatureWhether a second instrument has to be carried for the same visit. The temperature sensor shares the body and measures the air, not the surface being lit.
Power and autonomy Primary cells or a rechargeable pack, with or without automatic switch-offWhether a survey that runs over a day finishes on one set of cells, and whether the instrument protects itself from being left on.

The sensor mounting is decided before the range, because a fixed-head instrument cannot be rescued by an impressive span if the head will not go where the reading is needed.

How to choose a light meter

DecisionWhat settles itWhat to ask
The requirement being applied The illuminance the workplace or the task requiresThe required figure, and the margin the installation is meant to hold above it, decides the range and the accuracy the survey needs.
Where the sensor has to go Whether the measurement plane can be reached by handAbove a machine, inside a booth or in a ceiling grid, a separate sensor on a lead is the difference between a measurement and an estimate.
The range to be covered The brightest and dimmest conditions in the same surveyOne instrument is convenient and two are sometimes necessary; the span decides whether a multiplier has to be read carefully on every reading.
The light sources present Incandescent, fluorescent, LED or daylightA white LED source is where a poorly matched filter shows itself and where two instruments begin to disagree.
Whether the reading has to be recorded A survey sheet, or a report generated laterA hold function freezes a reading at the point of measurement; a logging function removes the transcription step and its errors.
Whether temperature is part of the visit The comfort assessment that accompanies the lighting checkA combined instrument is convenient, but its temperature channel measures the air around the body and not the surface being lit.
How the instrument will be carried The number of readings and the duration of the visitA body that survives being set down repeatedly is a practical requirement and does not appear in a data sheet.

If any of these are still open, send what is known. A quotation can be issued against a duty description and refined once the gaps are filled.

The nearest alternatives

These are the types an enquiry for a light meter usually turns out to be, and the point at which the choice is genuinely decided.

Nearest alternativeWhat separates it from a light meter
Noise meters Measure sound pressure where a light meter measures illumination. Both are used in the same workplace survey and against the same family of requirements, and neither can be substituted for the other.
Air quality monitors Report what is suspended in the air rather than how the space is lit. A room can meet its illuminance target and still be unsuitable to work in.
Dust monitors Measure particulate concentration in a process or an atmosphere rather than light. The two are occasionally confused because a dusty atmosphere also scatters light, but the quantities are unrelated.
Temperature and humidity data loggers Record the thermal conditions of a space over time. They are often carried on the same visit as a lighting survey and answer a different question about the same room.
Weather stations Measure ambient conditions at a fixed site over time, and their solar channel reports irradiance for an energy calculation rather than the illuminance a person works under.

The boundary worth settling first is what is being measured: light arriving at a surface, or light leaving a source. A light meter answers the first, and a spectral or colour instrument is needed for the second.

What to include in the enquiry

The first reply can be a quotation rather than a set of questions if the enquiry carries these. Where a figure is not known, send the duty description and we will confirm what it implies.

  1. The application and the requirement the reading will be compared against
  2. The illuminance range the survey has to cover, at both ends
  3. Whether the sensor has to be placed away from the operator, and how far
  4. The light sources present, and whether white LEDs are involved
  5. Whether the readings are transcribed by hand or logged
  6. Whether an ambient temperature channel is wanted on the same instrument
  7. The units the report is written in, lux or foot-candles
  8. Whether a calibration certificate is required with the instrument

Available products

1 model in Light Meters

Two digital lux meters side by side, the smaller one in a green case with its sensor on a short stalk, a reading of 455 on the LCD and 23.3 degrees beneath it, and the larger one in a black case with a bigger round sensor head and a display reading 288.5 lux in automatic range

AS803F (5 models) · Light Meters

Digital Lux Meter

Digital lux meter covering 0 to 200,000 lx with a sensor head that rotates through 180 degrees, lux and foot-candle units, data hold, maximum and minimum capture and a separate ambient temperature reading.

Measuring range
0 to 200,000 lx on the four AS instruments; 1 to 100,000 lx on the ST instrument
Resolution
1 lx and 0.1 degrees Celsius on the AS instruments; 0.1 lx on the ST instrument
Accuracy
plus or minus 4 percent of reading plus 10 digits at or below 10,000 lx and plus or minus 5 percent plus 10 digits above it; plus or minus 3 percent plus 5 lx on the ST instrument
Sensor
Silicon photovoltaic cell with a colour-correction filter

Also in Environmental Monitoring

Other product types in this category

Every type we quote for under Environmental Monitoring. A type with no link yet is still quoted for - it is described on the Environmental Monitoring overview, and gets a page of its own as soon as a model is published against it.

Frequently asked

Light Meters questions

Why does a light reading come out one hundred times too large or too small?

Because the multiplier shown beside the digits is part of the reading. Where the display cannot show every digit, the instrument shows the significant figures and marks the scale separately, so a displayed value with a multiplication marker is the number times that marker. Reading the digits alone produces a figure that is out by whatever the marker in the corner says, and it is the commonest error on a bright day.

Why do two light meters disagree under the same lamp?

Most often because their spectral responses differ. The lux scale is defined against a curve matching the human eye, and an element whose filter only approximates that curve reads a source with a narrow spectrum differently from one whose filter matches more closely. Sources with a strong narrow band, white LEDs in particular, show the difference most clearly, and the gap widens with the departure from the reference curve.

Does the sensor have to point straight at the light?

It has to be in the plane the measurement is defined on and held so that light arrives the way it will arrive at the task. A diffuser that corrects for the angle accounts for the fall-off as the sensor tilts, which is the correct behaviour, since a surface really does receive less light from a source it does not face. The error is not the tilt itself but a sensor that has left the plane the requirement names.

What has to be confirmed before a quotation?

The application and the requirement the reading will be judged against; the brightest and dimmest conditions the survey must cover; whether the sensor has to reach a place the operator cannot stand; the light sources present; whether readings are recorded or logged; whether temperature is wanted on the same instrument; and whether a calibration certificate has to accompany it.

Quoting for Light Meters

Send the specification and we will confirm the matching model, availability and lead time. Minimum order quantity is 1 pc.

Request for quotation

Request a quotation - Light Meters

Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.

The more of this you can give us, the fewer exchanges are needed before we can quote.
No file chosen
Datasheet, drawing, BOM or photograph. One file, up to 10 MB (PDF, Office, image or ZIP).

By submitting this form you agree that we may contact you about this enquiry. We do not sell or share enquiry data. See our privacy policy.

Items held in stock are dispatched within 48 hours of order confirmation. Customized specifications are produced to order and typically ship within 2 to 10 days. Transit time then depends on the shipping method and destination.

Request a Quote WhatsApp