Environmental Monitoring Instrumentation & Systems

Air, water, noise and emissions monitoring instruments for regulatory compliance and site surveillance.

What this sector has to measure

Environmental monitoring instruments measure conditions that are reported to somebody else. That single fact reorganises the priorities: the method is usually fixed by a regulation, a permit or a standard, the calibration interval is prescribed rather than chosen, and the deliverable is a record that an authority or an auditor will accept rather than a reading that merely happens to be accurate.

The specification conversation therefore starts with the obligation. Which parameter, under which method, reported in which format and at what frequency - those answers determine the instrument class, the calibration arrangement and the data handling before any technical comparison is meaningful. An instrument that measures well but cannot produce an acceptable record does not satisfy the requirement, however capable it is.

The second theme is that environmental measurements are samples of a variable environment rather than readings of a controlled process. Air moves, water flows, noise reflects and weather changes, so siting and sampling strategy affect the result as much as the instrument does. Unlike a process measurement, there is frequently no later opportunity to correct the placement, which is why it belongs in the planning stage rather than in the installation.

Where the instruments sit

Ambient air quality

Site boundary and community monitoring of gases, particulate and dust. Instruments run continuously, and siting and exposure determine whether the record actually represents the area being reported on.

Stack and emission monitoring

Flue gas, particulate and flow measurement at the point of release. The method is normally prescribed, the sample has to be conditioned, and the record frequently forms part of a permit condition.

Water quality and discharge

Effluent, surface water, groundwater and process discharge. pH, conductivity, turbidity, dissolved oxygen and specific substances are measured, and continuous measurement is often required alongside periodic sampling.

Noise, meteorology and the site record

Boundary and workplace noise, wind and weather, and the general conditions around the site. These measurements often exist to explain or support the others, and they carry their own calibration requirements.

Instrumentation used in this sector

MeasurementWhat is measured in this sectorInstruments commonly specified
Gas and vapour Ambient and stack concentrations of carbon monoxide, carbon dioxide, nitrogen oxides, sulphur dioxide, volatile compounds and oxygenProcess and ambient analysers using electrochemical, infrared, photoionisation or optical methods, with sample conditioning designed for the dust, condensate and temperature present
Particulate and dust Ambient particulate concentration, dust deposition, and particulate in a stackOptical scattering and gravimetric samplers for ambient work, and optical or gravimetric measurement for emission monitoring, with the method fixed by the permit
Water quality Effluent and surface water chemistry, including pH, conductivity, turbidity, dissolved oxygen and specific substancesIn-line analysers and transmitters with sample conditioning, and comparable instruments at the sampling points where continuous measurement is required
Flow Effluent discharge, surface water, and the flow in a stack or ductElectromagnetic and ultrasonic meters for liquid, and differential-pressure or ultrasonic measurement for stack flow, where the velocity profile and the straight runs available dominate the result
Noise Boundary, workplace and environmental noiseIntegrating sound level meters with the correct weighting and time constant, plus an acoustic calibrator used before and after a measurement series
Meteorology and data handling Wind speed and direction, temperature, humidity, rainfall, and the assembled site recordWeather station instruments alongside loggers and monitoring software that assemble the individual measurements into the record that has to be reported

The applicable method, the calibration interval and the form of the record are normally prescribed before the instrument is chosen, and they should be stated in the enquiry.

How to specify for an environmental monitoring programme

  1. The obligation first: which parameter, under which regulation, permit or standard, reported to whom and how often. In this sector that answer shapes everything else.
  2. The prescribed method, because it fixes the technology, the calibration interval and frequently the data format, and an alternative method may not be acceptable however well it performs.
  3. Whether the measurement is continuous or periodic, since sampling strategy and continuous monitoring are different disciplines with different equipment and different records.
  4. The calibration arrangement: what reference material or service is needed, whether it is available locally, and who carries the calibration out.
  5. Siting and exposure, which cannot easily be corrected later and which determine whether the record represents the area being reported on.
  6. Data handling, including completeness, validation, storage and the format in which the record has to be produced.
  7. The power and communications available at the monitoring point, since remote locations frequently decide the configuration rather than the measurement.
  8. Whether the measurement supports a legal obligation or an internal management target, because the two justify different levels of rigour, documentation and equipment.

Standards and approvals that may apply

  • The regulatory framework or permit that defines the parameters, the methods and the reporting frequency for the site.
  • Emission and discharge limits, which determine the range and the resolution the measurement has to cover rather than a general preference.
  • Ambient quality standards and monitoring methods, which govern the siting and the sampling arrangement as well as the instrument.
  • Calibration and traceability requirements, including any accreditation the measurement or the supporting laboratory has to hold.
  • We describe what an installation may have to meet. We do not claim that an approval is held for a product unless the certificate has been supplied to us, and the product pages follow the same rule.

Applications in this sector

Frequently asked

Environmental sourcing questions

The questions that come up in this sector before an order. If yours is not here, send it with the duty and we will answer it alongside the quotation.

How do I choose an instrument for a regulated measurement?

Start from the obligation rather than from the instrument. The regulation, permit or standard normally names the method, the calibration interval and the reporting format, and the instrument has to satisfy those three before any technical comparison is worth making. An instrument that measures accurately but cannot produce an acceptable record does not meet the requirement, so the obligation belongs at the beginning of the enquiry.

Continuous monitoring or periodic sampling?

Continuous measurement is required where the parameter varies in a way that sampling would miss, or where a permit demands a continuous record. Periodic sampling suits parameters that change slowly or where the analytical method is a laboratory one, and it is frequently used alongside continuous measurement for confirmation. Which applies is normally set by the obligation, so it is worth confirming rather than choosing on cost.

Why does siting matter so much?

Because an environmental measurement is a sample of a variable environment rather than a reading of a controlled process. A monitor in a stagnant corner, a sampler downstream of an inlet or a noise meter beside a reflecting wall measures the placement as much as the site, and unlike a process measurement it usually cannot be corrected later. The siting decision therefore belongs in the plan rather than at the installation.

What does emission monitoring need?

A method fixed by the permit, a sample that is conditioned to suit the analyser, and a record that satisfies the reporting requirement. Dust, condensate and temperature are the usual difficulties, and the sample conditioning is frequently the part that determines whether the system works in practice. Where flow at the release point is also reported, the velocity profile and the straight runs available affect the result as much as the instrument.

How is environmental noise measured?

With an integrating sound level meter, using the weighting and time constant the applicable method specifies, and verified with an acoustic calibrator before and after the measurement series. The result is normally an averaged level over a defined period rather than an instantaneous reading, and the microphone position and the reflecting surfaces around it affect the figure. Which weighting and which period apply come from the standard rather than from a preference.

What should an environmental enquiry include?

The parameter and the regulation, permit or standard it is reported under; the method and the calibration interval that apply; whether the measurement is continuous or periodic; the location, exposure and available power; the record format required; and whether the data has to reach a system. The obligation usually determines the specification, so it should be the first item in the enquiry.

Published products

Instruments available for this sector

Square indoor air quality monitor with a black face, showing the time at the top, a semicircular index dial reading 047 between the good and bad ends of the scale, temperature and humidity beside it, and six pollutant rows beneath covering formaldehyde, total volatile organic compounds, benzene, carbon dioxide and the two particle fractions

Air Quality Monitors

Multi-Parameter Air Quality Monitor

Indoor air quality monitor reading formaldehyde, total volatile organic compounds, benzene, carbon dioxide, PM2.5, PM10 and a combined index with temperature, humidity, WiFi app logging and history curves.

Monitored parameters
Formaldehyde, total volatile organic compounds, benzene, carbon dioxide, PM2.5, PM10 and a combined air quality index, plus temperature, humidity, time and date on the flagship version
Sensing elements
Electrochemical for formaldehyde, a micro-electromechanical module for total volatile organic compounds, filtered non-dispersive infrared for carbon dioxide, laser scattering for the particle fractions, and dedicated elements for temperature and humidity
Indicative thresholds
Formaldehyde 0.080, total volatile organic compounds 0.600, benzene 0.030, carbon dioxide 1000, PM2.5 75, PM10 100 and index 100, above which the material calls a reading over the limit; the figures are printed without units
Alarm
An audible alarm sounds on the combined index only; the other parameters do not alarm
A bench-top electric drying oven with its door closed, showing a double glazed viewing window, a rotary latch, and a control panel at the left with a two-line digital display, indicator lamps and a green mains switch

101-0A (13 models) · Laboratory Ovens

Electric Drying Oven

Electric drying oven with a chamber from 16 to 1000 litres, a working range from 5 degrees above ambient to 250 degrees Celsius, a galvanised or stainless-steel interior, forced air circulation on most models and a timed digital controller.

Temperature range
5 degrees above ambient to 250 degrees Celsius, with a stated ultimate limit of 300 degrees Celsius
Chamber volumes
16, 43, 70, 136, 225, 640 and 1000 litres
Interior
Galvanised steel on the A versions and stainless steel on the B versions; the two are the same size in the same volume
Convection
Bottom heating with an adjustable blower on the desktop range apart from the 202-0 pair; rear heating with a rear blower on the vertical range, twin blowers at 640 litres
Grey hand-held sound level meter with a black foam windscreen on the microphone, a red on and reset button above a liquid crystal display reading 58.6, and a sloped lower panel carrying the model number, the accuracy class against two standards, and control legends for the measurement functions

AWA5636-0 (5 models) · Noise Meters

Digital Sound Level Meter

Class 2 digital sound level meters in five configurations, from a basic instantaneous reading instrument up to an integrating and statistical model with 8000 records of storage.

Model range
AWA5636 in five configurations, numbered 0 to 4
Accuracy class
Class 2, stated against GB/T 3785.1-2010 and IEC 61672-1
Measurement range
40-130 dB(A) on the basic configuration; 30-130 dB(A) on configurations 1 to 4
Self-generated noise
<30 dB(A) on the basic configuration; <25 dB(A) on the others
White benchtop spectrophotometer with a rounded body, a red sample compartment lid set into the top, a sloped keypad panel carrying a small blue display at the right, and lettering printed along the lower front face above a black knob

LC-V1200E (9 models) · Spectrophotometers

UV-Vis Spectrophotometer

Benchtop single beam and double beam spectrophotometers in nine models, spanning the visible range on tungsten lamps and the ultraviolet and visible range on tungsten plus xenon, with bandwidths from 5 nm down to 1.8 nm.

Series
V series for the visible range on a tungsten lamp; UV series for the ultraviolet and visible range on tungsten plus xenon
Models
Nine model codes across the two series, from LC-V1200E to LC-UV1800
Wavelength range
350-1050 nm on LC-V1200E; 320-1100 nm on the other visible models; 190-1100 nm on every UV model
Spectral bandwidth
5 nm, 4 nm, 2 nm and 1.8 nm, by model
White pen-shaped water quality tester with a small dark display showing a reading and a score, two round keys beneath it and a marked water line near the lower end

LS310 (2 models) · Water Quality Analyzers

Multi-Parameter Water Quality Tester

Pen-type water quality tester reading COD, TOC, UV275, TDS, conductivity and temperature in one immersion, with a four-colour score display and an IP67 probe.

Parameters
COD, TOC, UV275, TDS, conductivity and temperature; LS311 adds salinity, hardness and specific gravity
Measuring range
COD 0 to 100 mg/L; TOC 0 to 100 mg/L; UV275 0 to 1.0 au/cm; TDS 0 to 2000 ppm; conductivity 0 to 4000 µS/cm; temperature 0 to 50 °C
Resolution
COD and TOC 0.01 mg/L; UV275 0.001 au/cm; TDS 1 ppm; conductivity 1 µS/cm; temperature 0.1 °C
Accuracy
COD and TOC ±0.5 mg/L below 5 mg/L and ±10% H above; TDS and conductivity ±3% FS; temperature ±1 °C
Radar level meter with a blue cap over a stainless cylindrical housing carrying two cable entries and a cover screw, a black nameplate on the body, and a large stainless flange at the base drilled for bolts with a raised sealing face in the centre

MIK-RD908 (3 models) · Radar Level Meters

80 GHz Radar Level Meter

Radar level meter in 80 GHz, low-frequency and guided-wave series for tanks, silos, rivers and pressurised vessels, with spans from 10 m to 80 m.

Model
Fourteen models across three series, from MIK-RD908 to MIK-RD702
Series
80 GHz high-frequency, low-frequency, and guided-wave
Range
0 to 10 m through to 0 to 80 m, according to series and model
Accuracy
±5 mm on the shortest spans through to ±30 mm at a 70 m span
A panel-mount dissolved oxygen analyzer with a black bezel and a backlit liquid crystal display showing an output setup screen, with four keys beneath the screen, alongside a stainless-steel electrode with a threaded mounting body and a cable

OHR-DO10 (2 models) · Dissolved Oxygen Analyzers

Online Dissolved Oxygen Analyzer

Online dissolved oxygen analyzer for continuous water monitoring, with a membrane or an optical electrode, temperature, salinity and pressure compensation, two alarm relays, an analogue output and a serial port.

Measurement range, membrane controller
0 to 200 percent saturation and 0 to 20.00 mg/L or ppm, with a temperature channel from 0.0 to 65.0 degrees Celsius
Measurement range, optical controller
0 to 20.00 mg/L or ppm, with the saturation range carried as a reserved parameter; electrode temperature 0 to 60 degrees Celsius
Accuracy
plus or minus 1.5 percent of full scale on the membrane controller; plus or minus 0.5 mg/L on the optical controller; temperature to plus or minus 0.5 degrees Celsius
Compensation
Temperature automatically by a sensing element in the electrode or manually; salinity entered manually; pressure entered manually
Integrated ultrasonic level meter standing upright with a translucent red top section, a grey threaded ring below it, a white body carrying two screened circular fittings on the front and the letters DC moulded beneath them, and a black lower section ending in the transducer face

SIN-MP-C (4 models) · Ultrasonic Level Meters

Ultrasonic Level Meter

Non-contact ultrasonic level meter for tanks, sumps, channels and silos, in integral and separate forms, with 4-20 mA and RS-485 outputs and a relay pair.

Model
SIN-MP-C / SIN-ULS-B / SIN-WSU100 / WSU200
Mounting
Non-contact, above the medium
Forms
Integral, with the transducer in the head, or separate, with the head and probe mounted apart
Range
0 to 1 m through to 0 to 15 m across the forms
Stainless steel cylindrical probe with a black end cap carrying a central pressure port and a ring of four smaller ports around it, joined to a coiled length of black cable with two bare conductors emerging at the far end

XK-136P · Hydrostatic Level Transmitters

Submersible Level Transmitter

Submersible hydrostatic level transmitter for water tanks, sumps, reservoirs and pits, from 1 m to 10 m as standard, with a probe rated IP68.

Model
XK-136P
Type
Submersible hydrostatic level transmitter with a vented cable
Range
0 to 1 m, 0 to 3 m, 0 to 5 m and 0 to 10 m as standard, to 500 m to order
Accuracy
0.5 class, with 0.2 class to order

Quoting for environmental

Send the process conditions and the standard you have to meet, and we will confirm the instrument, availability and documentation that can accompany the order.

Request for quotation

Request a quotation - Environmental

Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.

The more of this you can give us, the fewer exchanges are needed before we can quote.
No file chosen
Datasheet, drawing, BOM or photograph. One file, up to 10 MB (PDF, Office, image or ZIP).

By submitting this form you agree that we may contact you about this enquiry. We do not sell or share enquiry data. See our privacy policy.

Items held in stock are dispatched within 48 hours of order confirmation. Customized specifications are produced to order and typically ship within 2 to 10 days. Transit time then depends on the shipping method and destination.

Request a Quote WhatsApp