Laboratory Instruments · Laboratory Ovens

Electric Drying Oven

Electric drying oven with a chamber from 16 to 1000 litres, a working range from 5 degrees above ambient to 250 degrees Celsius, a galvanised or stainless-steel interior, forced air circulation on most models and a timed digital controller.

101-0A (13 models) ·

Key specifications

Temperature range
5 degrees above ambient to 250 degrees Celsius, with a stated ultimate limit of 300 degrees Celsius
Chamber volumes
16, 43, 70, 136, 225, 640 and 1000 litres
Interior
Galvanised steel on the A versions and stainless steel on the B versions; the two are the same size in the same volume
Convection
Bottom heating with an adjustable blower on the desktop range apart from the 202-0 pair; rear heating with a rear blower on the vertical range, twin blowers at 640 litres
Temperature accuracy
Stated as plus or minus 0.1 degrees Celsius on the vertical range and plus or minus 1 degree Celsius on the desktop range
Shelves
Two supplied with each chamber, rated at 15 kg each
Timer
1 to 9999 minutes
Supply
220 V up to 225 litres; 380 V at 640 and 1000 litres
Door
Double glazed viewing window, silicone door seal, adjustable vent in the top cover and a rotary latch
Chamber sizes
From 25 x 25 x 25 cm in the 16 litre unit to 100 x 100 x 100 cm in the 1000 litre unit

Heat is the most common tool in a laboratory and the least examined. A sample is dried, a coating is cured, glassware is dried before use, and the conditioning step is written into a method as a line of text, which is where the trouble starts: the line says what the instrument was set to rather than what the sample experienced, and the two are only the same when the chamber is empty.

A laboratory oven is that line of text made physical, and the whole of its specification is an attempt to close the gap between the setpoint on the display and the conditions on the shelf.

Product overview

The range is built around two structures and seven chamber volumes. The desktop units heat from the bottom and circulate air from the bottom, and run from 16 litres up to 225 litres on a single-phase supply before the larger sizes require three phases. The vertical units stand the chamber above the controls, heat and circulate from the rear, and are stated more tightly on temperature.

Within each structure the chamber can be galvanised or stainless steel. The two are the same size in the same volume, so the choice is a question of what the sample gives off rather than of what will fit, and it can be made after the size has been settled. Two shelves are supplied with every chamber and each is rated at 15 kg.

How the chamber holds a temperature

Elements heat the air and a controller reads a sensor and holds it at the setpoint. That loop is what the display reports, and on this range it is stated to hold to a tenth of a degree on the vertical structure and to a degree on the desktop one. Neither figure says anything about the rest of the chamber, because a controller can hold its own sensor closely while a corner of the shelf runs several degrees away from it.

What closes that gap is air movement. The blower carries heat into the load and through the shelf space rather than letting the chamber stratify, which is why the range is specified with a percentage uniformity figure for the whole chamber as well as an accuracy figure for the sensor. The two numbers describe different things and both are needed. The material states the uniformity as a percentage without naming the reference temperature or the method used to establish it, so it is recorded as an open point rather than published as a test result.

How to select the right drying oven

Start with the structure, because it follows from the method. Where a written procedure names a temperature and a tolerated deviation, the vertical structure is the one stated to meet it, and its stand also allows a tray beneath a dripping load. Where the work is general drying and keeping things warm and dry, the desktop structure does the same job with fewer demands on the bench.

Then take the volume from the batch rather than from the shelf. A chamber loaded to its nominal capacity has no free space left for air to move through, and the uniformity the specification offers is measured in an emptier chamber than that. After the size, the interior material follows the chemistry, and the supply voltage follows the size, since 640 litres and above are three-phase only.

Measurement limitations and selection considerations

The figures on this page describe what the chamber can hold, not what a particular load will experience. Drying is dominated by the latent heat of the water in the load, and a chamber that recovers quickly when empty will still sit below its setpoint for as long as evaporation continues. The material does not state a recovery time, so no attempt has been made to quantify one.

Two further points are open and are the ones to settle before an acceptance test. The uniformity figure is quoted as a percentage with no reference temperature or method attached, and no independent over-temperature cut-out is described, which is the protection that matters most when a controller fails with the elements energised. Both are listed for confirmation rather than assumed.

Features

  • A volume range from 16 to 1000 litres, so a bench unit and a floor-standing chamber can come from one range rather than two suppliers
  • Galvanised and stainless-steel interiors on the same external dimensions, which allows a specification to be upgraded for corrosion resistance without changing the installation
  • Forced air circulation on every model except the two 202-0 units, with the blower airflow adjustable on the desktop range and a rear blower on the vertical range
  • A double glazed viewing window, a silicone door seal and an adjustable vent in the top cover, which together let a wet load be watched and its moisture allowed to leave
  • A two-line digital controller showing the measured value against the setpoint, with a timer covering 1 to 9999 minutes
  • Two shelves supplied at 15 kg each, with the shelf steps spaced for the volume of the chamber

Technical specifications

Every value below is taken from source documentation. Where a parameter is not stated in the available material it is marked as information required rather than estimated.

Temperature and control
Working range5 degrees above ambient to 250 degrees CelsiusStandard
Ultimate limit300 degrees Celsius, stated as a limit not to be exceeded rather than as a working setpointStandard
Temperature accuracy, vertical rangeplus or minus 0.1 degrees CelsiusStandard
Temperature accuracy, desktop rangeplus or minus 1 degree CelsiusStandard
Temperature uniformity across the chamberStated as plus or minus 2 percent on the vertical range and plus or minus 3 percent on the desktop range, without a reference temperature or a test methodInformation required
ControllerDigital controller showing the measured value and the setpoint together, with a timer and a keypadStandard
Recovery time after the door is openedNot stated in the materialInformation required
Over-temperature protectionNot stated in the material beyond the note that the ultimate temperature must not be exceededInformation required
Chamber and construction
Chamber volumes16, 43, 70, 136, 225, 640 and 1000 litresStandard
Chamber dimensions25 x 25 x 25 cm at 16 litres; 35 x 35 x 35 cm at 43 litres; 45 x 35 x 45 cm at 70 litres; 55 x 45 x 55 cm at 136 litres; 60 x 50 x 75 cm at 225 litres; 80 x 80 x 100 cm at 640 litres; 100 x 100 x 100 cm at 1000 litresStandard
Interior materialGalvanised steel or stainless steel, selected by the model suffix; the two share the same external dimensions at a given volumeStandard
ShelvesTwo supplied, 15 kg rated each, with the shelf positions set by steps that differ by volumeStandard
Shelf step intervals5.5 cm at 16 litres up to 8 cm at 640 and 1000 litresStandard
Insulation thickness and heat lossNot stated in the materialInformation required
Internal chamber finish gradeNot stated in the materialInformation required
Installation
Supply220 V at 16 to 225 litres; 380 V at 640 and 1000 litresStandard
Power500 W at 16 litres, rising with volume to 5000 W at 640 litres and 6000 W at 1000 litresStandard
VentilationAdjustable vent in the top cover for moisture released by the loadStandard
Ingress protectionNot stated in the materialInformation required
Noise levelNot stated in the materialInformation required
Weight and packing dimensionsNot stated in the materialInformation required

Available models

Selection table
Model Configuration Key ranges Availability
202-0A / 202-0B 16 litre desktop chamber with no blower and bottom heating, galvanised on the A version and stainless steel on the B version 16 litres; 25 x 25 x 25 cm chamber; 220 V, 500 W; 3 shelf steps at 5.5 cm The entry model, and the only desktop pair without forced air circulation
101-0A / 101-0B 16 litre desktop chamber as the 202-0 but with an adjustable blower 16 litres; 25 x 25 x 25 cm chamber; 220 V, 500 W; 3 shelf steps at 5.5 cm The smallest unit with air circulation, which is the usual choice where a wet load has to dry
101-00A / 101-00B 43 litre desktop chamber with an adjustable blower 43 litres; 35 x 35 x 35 cm chamber; 220 V, 800 W; 4 shelf steps at 6.9 cm The step up in capacity before the 70 litre unit
101-1A / 101-1B 70 litre desktop chamber with an adjustable blower 70 litres; 45 x 35 x 45 cm chamber; 220 V, 1500 W; 5 shelf steps at 6.2 cm A common general-purpose size for a busy bench
101-2A / 101-2B 136 litre desktop chamber with an adjustable blower 136 litres; 55 x 45 x 55 cm chamber; 220 V, 2000 W; 6 shelf steps at 7.5 cm The largest desktop unit before the voltage changes at 640 litres
101-3A / 101-3B 225 litre desktop chamber with an adjustable blower 225 litres; 60 x 50 x 75 cm chamber; 220 V, 3000 W; 7 shelf steps at 8 cm The top of the 220 V desktop range
101-4A / 101-4B 640 litre chamber with an adjustable blower, supplied as a desktop unit and also listed with a rear blower on the vertical version 640 litres; 80 x 80 x 100 cm chamber; 380 V, 5000 W, twin blowers on the vertical version; 9 shelf steps at 8 cm The smallest size needing a three-phase supply, and the point at which a vertical stand becomes practical
101-5A / 101-5B 1000 litre chamber, the largest in the range 1000 litres; 100 x 100 x 100 cm chamber; 380 V, 6000 W; 9 shelf steps at 8 cm The floor-standing size, for drying or conditioning in quantity
101-0BS / 101-1BS / 101-2BS / 101-3BS / 101-4BS Vertical-stand versions with rear heating, a rear blower and a stainless-steel chamber, at 16, 70, 136, 225 and 640 litres; a galvanised option is listed for the same sizes in the range table 16 to 640 litres; 220 V to 225 litres and 380 V at 640 litres; stated accuracy plus or minus 0.1 degrees Celsius The vertical stand is specified where the load drips, since a tray can be placed beneath it, and it carries the tighter stated accuracy of the two structures

Customization

  • The interior material, since the galvanised and stainless-steel versions share a footprint and differ only in the chamber
  • The chamber volume, across seven sizes from 16 to 1000 litres
  • The structure, desktop or vertical, which changes the heating position, the blower position and the stated temperature accuracy
  • The supply voltage, which follows the volume and cannot be chosen freely at 640 litres and above
  • The shelf quantity beyond the two supplied, within the rated load of the chamber

Certification and compliance

Certification documents not yet supplied

Certifications are only published once a certificate copy can be produced, so this section is deliberately empty rather than populated with assumed approvals. Tell us which approvals your application requires and we will confirm what is available for this instrument.

Parameters still to be confirmed

The following are required for a complete specification but are not stated in the documentation supplied to us. They are listed rather than estimated:

  • The temperature uniformity figure expressed against a reference temperature and a test method, since the material states percentages only
  • The recovery time after the door is opened, which is the figure that describes a drying oven under load
  • Whether an independent over-temperature cut-out is fitted, and at what it operates
  • The thickness and grade of the chamber insulation, and the heat loss to the room
  • Whether the shelf positions are adjustable continuously or only at the stated steps
  • The surface finish and grade of the stainless-steel chamber
  • Ingress protection for the chamber and for the control panel
  • The weight and the packed dimensions of each size
  • The noise level of the blower
  • A calibration certificate or a factory test report for the chamber
  • An English-language datasheet covering the full size range
  • Whether the 101-4 and 101-5 sizes are supplied in both structures, since the range table lists the desktop form while the vertical form is listed only from 16 to 640 litres

Frequently asked questions

What is the difference between the desktop and the vertical versions?

The structure decides where the heat comes from and how accurate the chamber is stated to be. The desktop units heat from the bottom and circulate air from the bottom, and are stated at plus or minus 1 degree Celsius. The vertical units heat from the rear with a rear blower and are stated at plus or minus 0.1 degrees Celsius, and because the chamber stands above its own base a tray can be placed under a dripping load. Where a method names a temperature tolerance, the structure is what satisfies it.

Why is forced air circulation worth having?

Because still air carries heat slowly and lets the chamber stratify, so the temperature at the top and at the bottom of the shelf space can differ by more than the controller error. A blower moves the air through the load and keeps every shelf in the same stream, which is what turns a setpoint into a usable working volume. The exceptions in this range are the two 202-0 units, which rely on natural circulation and suit light, dry loads rather than wet ones.

Why does the reading fall when a wet load goes in?

Because water has to absorb a large amount of heat in order to evaporate, and that heat comes out of the chamber air. The controller then has to supply both the heat lost through the door and the heat being consumed by the load, and until the water is gone the chamber will sit below its setpoint. This is why the recovery behaviour of a drying oven matters more than its stated accuracy: a chamber that holds its setpoint when empty can still struggle for an hour with a full load of glassware.

What has to be confirmed before a quotation?

The duty and whether a written method sets the temperature and its tolerated deviation, which decides between the desktop and vertical structures; the chamber volume that one batch needs with the shelves loaded rather than empty; whether the load gives off moisture or carries solvents or corrosive residues, which decides between the galvanised and stainless-steel interiors and whether ventilation matters; the site voltage, which is 220 V up to 225 litres and 380 V at 640 litres and above; and the shelving required.

Related products

Other models in the same range

Mechanical double pan balance with a dark green painted base, two white moulded pans on a polished beam and linkage above them, a black printed rider scale running along the beam and marked to 5 g, and a graduated set of cylindrical metal weights with a pair of tweezers laid out in front

JPT-01 (6 models) · Laboratory Balances

Mechanical Pan Balance

Mechanical double pan balances in six capacities from 100 g to 5000 g, each supplied with its own weight set and tweezers, reading by lever and rider with no supply, no calibration routine and no data output.

Capacities
100 g, 200 g, 500 g, 1000 g, 2000 g and 5000 g across six models
Readability
0.1 g, 0.2 g, 0.5 g, 1 g, 2 g and 5 g by capacity, matching the verification scale interval on every model
Pan diameter
85 mm on the 100 g and 200 g models, then 115 mm, 140 mm, 170 mm and 205 mm as capacity rises
Method
Lever and Roberval mechanism with external weights and a sliding rider; no electronics, no supply and no calibration routine
White benchtop spectrophotometer with a rounded body, a red sample compartment lid set into the top, a sloped keypad panel carrying a small blue display at the right, and lettering printed along the lower front face above a black knob

LC-V1200E (9 models) · Spectrophotometers

UV-Vis Spectrophotometer

Benchtop single beam and double beam spectrophotometers in nine models, spanning the visible range on tungsten lamps and the ultraviolet and visible range on tungsten plus xenon, with bandwidths from 5 nm down to 1.8 nm.

Series
V series for the visible range on a tungsten lamp; UV series for the ultraviolet and visible range on tungsten plus xenon
Models
Nine model codes across the two series, from LC-V1200E to LC-UV1800
Wavelength range
350-1050 nm on LC-V1200E; 320-1100 nm on the other visible models; 190-1100 nm on every UV model
Spectral bandwidth
5 nm, 4 nm, 2 nm and 1.8 nm, by model

Request a quotation for the 101-0A

Send the configuration you need and we will confirm availability, lead time and terms. Minimum order quantity is 1 pc.

Request for quotation

Request a quotation - 101-0A

Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.

The more of this you can give us, the fewer exchanges are needed before we can quote.
No file chosen
Datasheet, drawing, BOM or photograph. One file, up to 10 MB (PDF, Office, image or ZIP).

By submitting this form you agree that we may contact you about this enquiry. We do not sell or share enquiry data. See our privacy policy.

Items held in stock are dispatched within 48 hours of order confirmation. Customized specifications are produced to order and typically ship within 2 to 10 days. Transit time then depends on the shipping method and destination.

Request a Quote WhatsApp