UV-Vis Spectrophotometer
Benchtop single beam and double beam spectrophotometers in nine models, spanning the visible range on tungsten lamps and the ultraviolet and visible range on tungsten plus xenon, with bandwidths from 5 nm down to 1.8 nm.
LC-V1200E (9 models) ·
Key specifications
- Series
- V series for the visible range on a tungsten lamp; UV series for the ultraviolet and visible range on tungsten plus xenon
- Models
- Nine model codes across the two series, from LC-V1200E to LC-UV1800
- Wavelength range
- 350-1050 nm on LC-V1200E; 320-1100 nm on the other visible models; 190-1100 nm on every UV model
- Spectral bandwidth
- 5 nm, 4 nm, 2 nm and 1.8 nm, by model
- Wavelength accuracy
- 2 nm, 1 nm or ±0.5 nm, by model
- Photometric accuracy
- ±0.8 %T, ±0.5 %T or ±0.3 %T, by model
- Stray light
- ≤0.2 %T, ≤0.1 %T or ≤0.05 %T, by model
- Drift
- ≤0.003 A on every model
- Optical system
- Single beam on all models except LC-UV1800, which is double beam
- Wavelength adjustment
- Automatic single wavelength, or automatic scanning for a continuous spectrum, by model
A spectrophotometer answers a different kind of question from most of the instruments it stands beside. It does not report a property of the sample directly; it reports how much light the sample absorbed at a wavelength someone chose, and everything else - concentration, purity, whether a reaction went where it was supposed to - is inferred from that. The choice that fixes everything downstream is therefore which wavelengths the instrument can reach and how finely it can separate them.
This range covers nine models in two series. The V series works in the visible region on a tungsten lamp; the UV series adds a xenon lamp and reaches down to 190 nm. Across them the bandwidth runs from 5 nm to 1.8 nm, the wavelength accuracy from 2 nm to ±0.5 nm, and all but one model are single beam.
What the instrument measures
Four quantities are reported: transmittance, absorbance, concentration and the slope factor that connects the last two. Transmittance is the fraction of the incident light that passes through the sample. Absorbance is its negative logarithm, which is the quantity that is proportional to concentration in the working range and the one most measurements are actually taken in. Concentration follows from absorbance through a factor established against standards of known concentration, and the slope factor is that conversion held by the instrument.
Because the relationship between absorbance and concentration is linear only within limits, the useful measuring range is narrower than the scale suggests. A sample that is too concentrated reads as though it were dilute, because the relationship stops being linear before the detector runs out of signal. That is a property of the method rather than of the instrument, and it is why the choice of path length and of dilution matters as much as the model chosen.
How the measurement works
Light from the lamp is dispersed by a 1200 line per millimetre holographic grating in a Czerny-Turner monochromator, which turns the broad output into a narrow band at a chosen wavelength. That monochromatic beam passes through the sample, and the intensity reaching the detector is compared with the intensity that reached it through a reference. The ratio is transmittance, and the logarithm of its reciprocal is absorbance.
Three things follow from that arrangement. The first is that the source and the detector are as much a part of the measurement as the sample is, which is why source life and drift appear on the specification at all. Drift is quoted as ≤0.003 A on every model, and it is the figure that decides whether a small absorbance difference can be trusted over a long run. The second is that the monochromator sets the resolution: the grating is common to the range, but the slit width behind it, quoted as spectral bandwidth, is not, and it is the bandwidth rather than the grating that decides whether two close peaks stay separate. The third is that the reference matters. Every measurement is a ratio, so anything that changes between the reference and the sample reading lands in the result unless the optics measure both at the same time or the instrument is re-zeroed often enough.
Choosing between the visible and ultraviolet series
The visible series reaches 320-1100 nm, except on LC-V1200E where the span is 350-1050 nm. The ultraviolet series reaches 190-1100 nm on every model, the additional span coming from a xenon lamp alongside the tungsten one. Nothing else in the specification decides this: a method written below about 320 nm cannot be run on a visible instrument, because there is no light there to absorb, and a method written above that wavelength does not need the ultraviolet series unless something else in the same laboratory does.
Where both regions are needed from one instrument, the UV series covers the visible region in the same box, so there is no reason to buy the visible series as well. Where the work is entirely in the visible region and the laboratory has no intention of moving below 320 nm, the visible models reach the same wavelengths with the same grating at a lower specification cost.
Bandwidth, and why it decides whether two peaks resolve
Spectral bandwidth is the width of the band of wavelengths the instrument actually passes at any one setting, and it runs here from 5 nm to 1.8 nm. A wide bandwidth is not simply a coarser reading: it averages together everything inside that 5 nm window, so two absorption peaks sitting within a few nanometres of each other are reported as one broad shoulder, and no amount of care elsewhere recovers them. A bandwidth comfortably narrower than the peak being measured is the requirement, and where a method states a peak width the bandwidth can be chosen against it directly.
That is the reason the range spans a factor of nearly three in bandwidth across nine models. Where a method reads a broad visible peak at a fixed wavelength, a 4 nm or 5 nm bandwidth is not a compromise. Where the method involves a sharp peak, a shoulder, or two peaks that have to be separated, the 1.8 nm or 2 nm models are the ones that can do it.
Single wavelength or scanning
The base models are set to a single wavelength and read the sample there, which is what a routine determination needs and is the fastest way to run one. The N and NC models and the Pro and 1800 models scan: the wavelength moves continuously and the spectrum is recorded across a range, which is what is required to locate a peak, to compare a sample against a reference spectrum, or to establish that nothing unexpected is absorbing elsewhere in the range.
Scanning is not only for research work. Any method that has to be validated in the laboratory, or that may be disturbed by an interfering substance, is easier to defend with a spectrum than with a single point, and a spectrum taken once often removes a later argument. Where a method is fixed at one wavelength and the answer is simply the number at that wavelength, single wavelength operation is not a limitation and the scanning models are not needed.
Single beam and double beam
Eight of the nine models are single beam, which measures the reference and the sample at different moments and relies on re-zeroing to keep the two comparable. LC-UV1800 is double beam, which splits the light so that the sample and the reference are measured at the same time and any change affecting both cancels continuously. In a single beam instrument, source drift, detector drift and a temperature change in the compartment all enter the result between the reference reading and the sample reading; periodic re-zeroing removes most of that, which is why single beam instruments remain perfectly adequate for routine work.
The difference becomes worth paying for in two situations: a measurement that has to be held stable over a long period, and a method in which the absorbance difference between the sample and the reference is small enough that drift is a significant part of it. LC-UV1800 also carries the finest bandwidth in the range at 1.8 nm, so it is the instrument for a laboratory that needs both a narrow bandwidth and stability rather than one that simply wants the top of the list.
Cuvettes, the compartment and the consumables
Every model is supplied with a four position cuvette holder, either a fixed 1 cm holder or on some models a 0.5-5 cm adjustable one, and a box of four 1 cm glass cuvettes. The UV models add two quartz cuvettes. That is the set, and the point to hold on to is that glass does not transmit in the ultraviolet: any measurement below about 320 nm needs quartz cells, they come only with the UV models, and they have to be ordered separately. Extra quartz cells are an order item in their own right rather than an accessory that can be borrowed from another instrument.
The path length of the holder matters in the same way the bandwidth does: absorbance is proportional to the distance the light travels through the sample, so a 0.5 cm and a 5 cm holder measure different amounts of the same solution. Where a method states a path length, the holder has to match it, and where a dilute sample has to be read without concentration, a longer path length raises the absorbance into the useful range.
Measurement limitations and selection considerations
Several parameters that matter in a laboratory are not stated anywhere in the material: the mains supply, the warm-up time, the ambient temperature and humidity limits, the source replacement interval, the ingress protection of the enclosure, and the light source life per model. Nothing here is inferred to fill those gaps, and the material’s own note that its figures are the supplier’s nominal values, to be confirmed against the delivered nameplate and manual, applies to the whole page.
Two operational limits are worth stating plainly. The instrument weighs between 7 kg and 12.5 kg depending on the model and is a bench instrument whose optical path is sensitive to vibration, so it belongs on a stable bench rather than a shared trolley. And the lamps are consumables with a rated life of 1000 h or 2000 h by model, which the material notes is shortened by frequent switching, so an instrument that is used throughout a working day is better left running than switched on and off around each measurement.
Where the instrument is to be used for regulated testing, the qualification documents are a separate requirement. The material records that certification material was removed at source and that no certificate information is included, and it advises requesting the type approval certificate and the 3Q validation documents from the supplier for pharmaceutical and food testing. That is a question for the enquiry rather than an assumption from the delivery.
Ordering
The items that decide the answer are the wavelength or wavelengths the method uses, the peak width and therefore the bandwidth required, whether single wavelength operation is enough or a spectrum has to be recorded, whether the ultraviolet region is needed at all, the path length of the cells, whether the results have to be captured on a computer, and which documents the laboratory’s quality system requires. State the method rather than only the model where possible, because the wavelength and the peak width are what fix the model list rather than the other way round. Quantity, destination port and required delivery date complete the enquiry.
Features
- A bandwidth that reaches 1.8 nm on LC-UV1800, which is what decides whether two close absorption peaks can be separated at all
- A UV series that reaches down to 190 nm, so the ultraviolet region below 320 nm is covered where the visible series cannot go
- Automatic scanning on the N and NC models and above, which produces a spectrum rather than a single point reading
- A double beam optical system on LC-UV1800, which removes source drift and background absorption from the measurement continuously rather than by periodic re-zeroing
- Four measuring modes across the range, with automatic zeroing and the ability to hold, print and store a reading
- A four position sample compartment with a pull rod, so several samples can be run without handling the cuvettes inside the compartment
Technical specifications
Every value below is taken from source documentation. Where a parameter is not stated in the available material it is marked as information required rather than estimated.
| Grating | 1200 line per millimetre holographic gratingStandard |
|---|---|
| Monochromator | Czerny-Turner configurationStandard |
| Optical system | Single beam on all models except LC-UV1800, which is double beamStandard |
| Light source, V series | Tungsten lampStandard |
| Light source, UV series | Tungsten lamp plus xenon lampStandard |
| Source life | Given as 1000 h or 2000 h by model group, and not resolved model by model in the materialInformation required |
| Wavelength adjustment | Automatic single wavelength on the base models; automatic scanning on the N and NC models and the Pro and 1800Standard |
| Range, LC-V1200E | 350-1050 nmStandard |
|---|---|
| Range, other visible models | 320-1100 nmStandard |
| Range, all UV models | 190-1100 nmStandard |
| Accuracy | 2 nm on LC-V1200E and LC-V1200; 1 nm on LC-V1200N, LC-UV1200NC and LC-UV1200N; ±0.5 nm on LC-V1200NC, LC-UV1200Pro and LC-UV1800Standard |
| Repeatability | 1 nm on LC-V1200E and LC-V1200; 0.5 nm on LC-V1200N, LC-UV1200NC and LC-UV1200N; ±0.2 nm on LC-V1200NC, LC-UV1200Pro and LC-UV1800Standard |
| Transmittance accuracy | ±0.8 %T on LC-V1200E; ±0.5 %T on LC-V1200, LC-V1200N, LC-V1200NC, LC-UV1200, LC-UV1200NC and LC-UV1200N; ±0.3 %T on LC-UV1200Pro and LC-UV1800Standard |
|---|---|
| Transmittance repeatability | 0.2 %T on the V series; ≤0.2 %T on LC-UV1200, LC-UV1200NC and LC-UV1200N; ≤0.1 %T on LC-UV1200Pro and LC-UV1800Standard |
| Stray light | ≤0.2 %T on LC-V1200E and LC-V1200; ≤0.1 %T on LC-V1200N and LC-UV1200NC and LC-UV1200N; ≤0.05 %T on LC-V1200NC, LC-UV1200Pro and LC-UV1800; LC-UV1200 is listed as ≤0.2 %TStandard |
| Drift | ≤0.003 A on every modelStandard |
| Notation of the stray light and accuracy figures | The material records that some models carry a ± sign and some do not, and that some state a measuring wavelength and some do not, and that it transcribed each figure as found without normalising themInformation required |
| Measuring modes | Transmittance, absorbance, concentration and slope factor; automatic zeroing; data hold, print and storeStandard |
| Display | 128 x 64 dot matrix monochrome, LED high brightness, 4.3 inch capacitive touch, or 7 inch colour touch, by modelStandard |
|---|---|
| Data output | USB link socket and USB drive socket, with the PC system an optional itemStandard |
| PC connection by model | The material states that support for computer software connection applies to LC-V1200N and above and that the base models do not have a PC link, while the model table lists the USB and drive sockets for every model; which UV models fall outside the statement is not givenInformation required |
| Optional PC items | USB data cable, software manual, USB drive holding the application software and password, and a dongle, all listed as optionsOptional |
| Cuvette holder | 1 cm four position manual holder as standard; some models list a 0.5-5 cm adjustable four position holder insteadStandard |
|---|---|
| Glass cuvettes supplied | Four 1 cm glass cuvettes with every modelStandard |
| Quartz cuvettes supplied | Two 1 cm quartz cuvettes with the UV models onlyStandard |
| Sample compartment | Four position compartment with a pull rod for the sample holderStandard |
| Printer and computer connection | Printer, mains inlet and computer connection are provided at the rear of the instrumentStandard |
| Supplied with the instrument | Main unit, mains lead, cuvette holder, dust cover, operating manual, cuvette box and packing listStandard |
| Net weight | 7 kg to 12.5 kg by model; the weight of LC-V1200NC is left blank in the materialInformation required |
|---|---|
| Dimensions | 460 x 310 x 210 mm on every model except LC-UV1800, which is 470 x 325 x 220 mmStandard |
| Mains supply | Information requiredInformation required |
| Warm-up time | Information requiredInformation required |
| Ambient temperature and humidity | Information requiredInformation required |
| Ingress protection | Information requiredInformation required |
Available models
| Model | Configuration | Key ranges | Availability |
|---|---|---|---|
| LC-V1200E | Visible, single beam, 5 nm bandwidth, 350-1050 nm, automatic single wavelength, 128 x 64 dot matrix display, 7 kg | Wavelength accuracy 2 nm, repeatability 1 nm; transmittance accuracy ±0.8 %T; stray light ≤0.2 %T at 360 nm | The entry model of the visible series. The coarsest bandwidth in the range and the narrowest wavelength span, at 350-1050 nm |
| LC-V1200 | Visible, single beam, 4 nm bandwidth, 320-1100 nm, automatic single wavelength, LED display, 8 kg | Wavelength accuracy 2 nm, repeatability 1 nm; transmittance accuracy ±0.5 %T; stray light ≤0.2 %T at 360 nm | Steps the span up to 320-1100 nm and the photometric accuracy to ±0.5 %T over LC-V1200E |
| LC-V1200N | Visible, single beam, 2 nm bandwidth, 320-1100 nm, automatic wavelength scanning, LED display, 9 kg | Wavelength accuracy 1 nm, repeatability 0.5 nm; transmittance accuracy ±0.5 %T; stray light ≤0.1 %T | The first model in the visible series with scanning, which is what produces a continuous spectrum rather than a point reading |
| LC-V1200NC | Visible, single beam, 2 nm bandwidth, 320-1100 nm, automatic wavelength scanning, 4.3 inch capacitive touch display | Wavelength accuracy ±0.5 nm, repeatability ±0.2 nm; transmittance accuracy ±0.5 %T; stray light ≤0.05 %T at 360 nm | The finest visible model on accuracy and stray light. The material leaves its net weight blank |
| LC-UV1200 | UV-visible, single beam, 4 nm bandwidth, 190-1100 nm, automatic single wavelength, 128 x 64 dot matrix display, 8 kg | Wavelength accuracy 2 nm, repeatability 1 nm; transmittance accuracy ±0.5 %T; stray light ≤0.2 %T | The entry model of the UV series, covering the ultraviolet region that the visible series cannot reach |
| LC-UV1200N | UV-visible, single beam, 2 nm bandwidth, 190-1100 nm, automatic wavelength scanning, 4.3 inch capacitive touch display, 11 kg | Wavelength accuracy 1 nm, repeatability 0.5 nm; transmittance accuracy ±0.5 %T; stray light ≤0.1 %T | Scanning UV model with a finer bandwidth than LC-UV1200 |
| LC-UV1200NC | UV-visible, single beam, 2 nm bandwidth, 190-1100 nm, automatic wavelength scanning, 7 inch colour touch display, 9 kg | Wavelength accuracy 1 nm, repeatability 0.5 nm; transmittance accuracy ±0.5 %T; stray light ≤0.1 %T | The larger touch display and a lighter bench weight than LC-UV1200N at the same optical specification |
| LC-UV1200Pro | UV-visible, single beam, 2 nm bandwidth, 190-1100 nm, automatic wavelength scanning, 7 inch colour touch display, 10.5 kg | Wavelength accuracy ±0.5 nm, repeatability ±0.2 nm; transmittance accuracy ±0.3 %T; stray light ≤0.05 %T | The finer photometric grade in a single beam instrument. The material gives this model a column in its model table without expanding the detail, so its full parameter set is listed as information required |
| LC-UV1800 | UV-visible, double beam, 1.8 nm bandwidth, 190-1100 nm, automatic wavelength scanning, 7 inch colour touch display, 12.5 kg, 470 x 325 x 220 mm | Wavelength accuracy ±0.5 nm, repeatability ±0.2 nm; transmittance accuracy ±0.3 %T; stray light ≤0.05 %T | The finest bandwidth in the range and the only double beam instrument, which is what suits a measurement held over a long period |
Customization
- Optional computer system comprising a USB data cable, a software manual, a USB drive holding the application software and password, and a dongle
- Cuvette holder supplied as a 1 cm four position manual holder or, on some models, a 0.5-5 cm adjustable four position holder where a different path length is needed
- Quartz cuvettes ordered separately for work in the ultraviolet, since only the UV models include two as standard
Certification and compliance
Certification documents not yet supplied
Certifications are only published once a certificate copy can be produced, so this section is deliberately empty rather than populated with assumed approvals. Tell us which approvals your application requires and we will confirm what is available for this instrument.
Parameters still to be confirmed
The following are required for a complete specification but are not stated in the documentation supplied to us. They are listed rather than estimated:
- The full parameter set for LC-UV1200Pro, which the material gives a column in its model table without expanding
- The net weight of LC-V1200NC, which is left blank in the material
- Light source life for each model individually, since the material groups it as 1000 h or 2000 h without resolving every model
- Whether the PC software connection is absent on the base UV model as well as on the base visible models
- Mains supply voltage and frequency, consumption, and fuse rating
- Warm-up time before measurement, and the recommended re-zeroing interval
- Ambient temperature and humidity limits for operation and storage
- Ingress protection of the enclosure
- Type approval certificate and 3Q validation documents for regulated laboratories
- The wavelength at which the stray light figures were determined, where the material does not state one
- Whether the 0.5-5 cm adjustable cuvette holder is available for the models that list a fixed 1 cm holder
- Independent quotation for the optional PC system and for additional quartz cuvettes
- Warranty period and the terms that apply
- English-language datasheet and a single table comparing all nine models
- Packaging dimensions and gross weight for freight calculation
Frequently asked questions
Do I need the visible series or the ultraviolet series?
The answer is fixed by the wavelength the method calls for, not by the application. The visible series works from 320-1100 nm, or 350-1050 nm on the entry model, and the ultraviolet series works from 190-1100 nm. A method that reads in the ultraviolet region below about 320 nm cannot be run on a visible instrument at all, because there is no light there. If the method is stated at a wavelength above 320 nm and nothing else in the laboratory needs the ultraviolet region, the visible series reaches it for less. If any method starts below 320 nm, the UV series is the only one that will do, and the instrument will also cover the visible region in the same box.
How much does spectral bandwidth matter?
More than almost any other figure on the specification, because it decides whether two absorption peaks close together can be told apart. The range here runs from 5 nm on LC-V1200E to 1.8 nm on LC-UV1800, which is nearly a threefold difference. Where a method has a narrow peak, or where two peaks sit close together, a wide bandwidth averages them into one broad shoulder and the measurement cannot separate them however carefully it is run. The correct approach is to start from the width of the peak being measured and choose a bandwidth comfortably narrower than it, rather than from the price of the instrument.
What is the difference between automatic wavelength and automatic wavelength scanning?
A single wavelength instrument is set to one wavelength and reads the sample there, which is what a routine determination at a fixed wavelength needs. A scanning instrument moves the wavelength continuously and records the spectrum across a range, which is what is required to find a peak, to check a sample against a reference spectrum, or to confirm that nothing unexpected is absorbing elsewhere. The scanning models are the N and NC versions and above. Where a method is written at one wavelength and the instrument only has to report that one number, single wavelength operation is not a limitation.
When is a double beam instrument worth it?
When the measurement has to hold for a long time or when the source drifts during it. A single beam instrument measures the reference and then the sample, so anything that changes between the two - source intensity, detector response, the temperature of the compartment - lands in the result, and the instrument is re-zeroed periodically to keep it out. A double beam instrument splits the light and measures the sample and the reference at the same time, so that drift cancels continuously. LC-UV1800 is the double beam model in this range, and the benefit shows in long runs and in methods with a small absorbance difference rather than in a routine single reading.
What has to be bought alongside the instrument?
The instrument arrives with the main unit, mains lead, cuvette holder, dust cover, operating manual, a box of four 1 cm glass cuvettes and a packing list, and the ultraviolet models add two 1 cm quartz cuvettes. Quartz cuvettes are the item most often overlooked: glass does not transmit in the ultraviolet, so any work below about 320 nm needs quartz cells, they are supplied only with the UV models, and they have to be ordered separately. If the instrument is to be connected to a computer, the PC system - data cable, software manual, USB drive and dongle - is an optional item rather than part of the standard delivery.
Can the instrument be used for regulated testing?
The instrument itself is supplied without metrology documents: the material records that certification material was removed at source and states that no certificate information is included, and it advises anyone using the instrument for pharmaceutical or food testing to request the type approval certificate and the 3Q validation documents from the supplier. So for a regulated laboratory the qualification documents are a separate requirement to be raised and confirmed rather than assumed from the delivery. Where a laboratory quality system also requires the balance or the calibration weights to be traceable, that is a separate supply as well.
Request a quotation for the LC-V1200E
Send the configuration you need and we will confirm availability, lead time and terms. Minimum order quantity is 1 pc.
Request for quotation
Request a quotation - LC-V1200E
Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.