Level Measurement · Hydrostatic Level Transmitters

Submersible Level Transmitter

Submersible hydrostatic level transmitter for water tanks, sumps, reservoirs and pits, from 1 m to 10 m as standard, with a probe rated IP68.

XK-136P ·

Key specifications

Model
XK-136P
Type
Submersible hydrostatic level transmitter with a vented cable
Range
0 to 1 m, 0 to 3 m, 0 to 5 m and 0 to 10 m as standard, to 500 m to order
Accuracy
0.5 class, with 0.2 class to order
Annual drift
±0.2 % of full scale
Output
4-20 mA as standard, with 0-5 V and RS-485 options
Supply
24 V DC
Overload
150 %
Protection
Probe IP68, assembly IP65
Wetted materials
316L diaphragm, 304 stainless housing, rubber cable

A submersible level transmitter is the direct answer to a level measurement, and it is the one that asks least of the vessel. The probe is dropped into the liquid on the end of its cable and read; there is no mounting to arrange, no alignment to set and no clear path to keep open. What it asks for instead is a liquid whose density is known and stable, and a vessel it can be lowered into.

It is also the one of the three common level technologies that does not care what the surface is doing, which is what makes it the instrument for a sump, a pit and a river gauge.

How the level is obtained

The measurement is the pressure at the bottom of the vessel. A column of liquid exerts a pressure at its base that rises in proportion to its depth, the density of the liquid and gravity, so a sensor resting on the bottom sees a pressure that tracks the level directly. The transmitter converts that pressure into a level once it has been told the density of the medium.

That single sentence contains both the strength and the weakness of the type. The strength is that pressure is indifferent to foam, vapour, condensation, a slopping surface and everything else that troubles a non-contact instrument. The weakness is that the conversion depends on the density, so the level reported is only as good as the density assumed. A tank that sometimes holds water and sometimes a process fluid, or a liquid whose density moves with temperature, will give two different levels from one pressure reading.

What the vented cable does

The probe has to be referenced to something, and the atmosphere is what it is referenced to. A tube inside the cable runs from the sensing element to the terminal, where it is left open to air, so that the measurement is a gauge pressure rather than an absolute one. Without it the instrument would read the pressure of the headspace as well as the depth of the liquid, and the reading would move with the barometer.

That makes the cable part of the instrument rather than an accessory, which is why the material supplies a cable length matched to the range and why the vent tube is worth protecting during installation. A kinked, pinched or flooded tube produces a level reading that drifts for reasons invisible at the instrument, and it is one of the few failure modes the installer introduces rather than the process.

Choosing the range and the form

The range is chosen from the depth to be measured, and the useful test is not the maximum depth but the normal level: a range far larger than the duty uses only a fraction of the instrument’s span and gives away resolution that was paid for. The material offers standard ranges from one metre to ten metres, with the current-output form available to 100 m and a special construction to 500 m.

The probe is then matched to the medium. The standard wetted materials are a 316L diaphragm in a 304 stainless housing on a rubber cable, which suits water, wastewater and oils. Where the medium would attack them, the material offers an anti-corrosion version, and where the temperature exceeds the standard limit it offers a high-temperature version. Because the probe is immersed permanently, this compatibility question is decided before range or accuracy, not afterwards.

Installation and keeping the reading still

The material gives three ways of fixing the probe, and the choice between them is about the water rather than about the instrument. Direct immersion suits static, clean liquid: the probe is lowered to just above the floor and the cable secured above the surface. A perforated stilling pipe is the answer in a dirty or fast-moving sump, where it keeps solids away from the ports and removes the effect of waves and velocity. A perforated fixing block on the floor is the third, for a flow strong enough to move the probe, since a probe that is not vertical and still does not read the head of liquid above it.

That concern is the practical one for this type. A reading that moves with the flow rather than with the level is usually an inlet discharging onto the probe, and the material offers three specific remedies for it: reshaping the inlet so the stream breaks into droplets, turning the inlet upward so the water spends its energy in the air, or shielding the probe inside a perforated pipe.

Measurement limitations and selection considerations

The limitations follow from the principle. A single gauge transmitter cannot be used in a sealed or pressurised vessel, because there is no atmosphere to reference against and the headspace pressure would be added to the reading; a differential arrangement is the answer there. The reading is only as good as the density assumed, which matters in a tank that holds more than one product. And the probe has to be compatible with the medium for the whole of its life, since it is immersed continuously rather than occasionally.

The material also leaves several figures unsettled. The working temperature is given two different ways in the same document, from -10 to 40 °C in the table and -20 to 40 °C on the order cards. The accuracy is given as a class in one place and as a resolution percentage in another, which are different quantities. The overload rating is given as a percentage without a time. And the control instrument’s outputs are stated as four relays with no analogue or communication output given.

Ordering

The items that fix the answer are the medium, its density and whether either changes; the maximum depth and the lowest and highest levels in service; whether the vessel is open to atmosphere; the chemical compatibility of the wetted materials and any cleaning agents the probe will meet; the medium and ambient temperatures, working and extreme; the range and the cable length, which are ordered together; the output required and what will read it; whether the installation only measures or also drives a pump or an alarm; and how the cable will be run and glanded. A tank description and the medium are enough for a covering quotation. Quantity, destination port and required delivery date complete the enquiry.

Features

  • A submersible probe rated IP68, so the instrument can be lowered into a sump, a pit or a reservoir instead of being mounted to the vessel at all
  • An overload rating of 150 % and a drift figure of ±0.2 % of full scale per year, which between them decide how long the instrument can be left in place without attention
  • A response time of T90 ≤1 ms, fast enough for level control rather than for indication only
  • Temperature compensation, fitted because both the density of the medium and the behaviour of the sensing element change with temperature
  • Pressure ports in a four-port sloped arrangement, described as designed not to block in dirty water
  • An optional control instrument with four relay contacts, so one unit can display a level, alarm on it and drive a pump
  • An anti-corrosion version for media that the standard stainless probe cannot withstand

Technical specifications

Every value below is taken from source documentation. Where a parameter is not stated in the available material it is marked as information required rather than estimated.

Measuring performance
Range0 to 1 m, 0 to 3 m, 0 to 5 m and 0 to 10 m as standard, and to 500 m to orderStandard
Accuracy0.5 class, with 0.2 class to order; the order cards also quote a resolution of 0.5 %, which is a different quantity from an accuracy class and is not reconciled with it in the materialInformation required
Annual drift±0.2 % of full scaleStandard
Overload150 %Standard
Response timeT90 ≤1 msStandard
Temperature compensation0 to 40 °CStandard
RepeatabilityNot stated in the materialInformation required
Electrical
Output4-20 mA as standard; 0-5 V and RS-485 to orderStandard
Supply24 V DCStandard
Wiring, current outputTwo-wire, one conductor carrying the supply and one carrying the signalStandard
Wiring, voltage outputThree-wire, with a common conductor in addition to the supply and signalStandard
Control instrument relaysFour relay contacts; no analogue or communication output is stated for the instrumentStandard
Control instrument supply220 V, with a 24 V feed to the transmitterStandard
Cable length against range5 m of cable for ranges up to 5 m, and a cable equal to the range for 6 m and aboveStandard
Output against rangeThe 4-20 mA form is offered from 1 m to 100 m; the RS-485 form is offered from 1 m to 15 mStandard
Mechanical and environment
Wetted materials316L stainless diaphragm, 304 stainless housing and a rubber cableStandard
Probe dimensions26 mm diameter by 110 mm longStandard
SealingMulti-stage sealing and a double waterproof construction, described in the materialStandard
Pressure portsFour ports in a sloped arrangement, described as designed not to blockStandard
CableFlexible and waterproof, shielded, with a vent tubeStandard
Ingress protectionProbe IP68, assembly IP65Standard
Working temperatureThe material gives -10 to 40 °C in its table and -20 to 40 °C on the order cards, and both are carriedInformation required
Medium temperature-20 to 40 °C on the order cards; the material states that a higher temperature requires a special versionStandard
Storage temperatureNot stated in the materialInformation required
Control instrument
Panel size160 × 80 mm, with a 152 × 76 mm cutout and an 84 mm depthStandard
DisplayA light column and a digital reading togetherStandard
Alarm settingsFour points, described as high, high-high, low and low-lowStandard
KeysSet, increase, decrease and shift, with a mute switchStandard
FunctionsLevel display, level alarm and level controlStandard
Control arrangementThe material shows a fill arrangement in which a valve is opened on a low level and closed on a high one, and the same instrument controlling a drainStandard
2026-11 supply batch
ScopeAdditional forms supplied in November 2026 for this product type. Figures below are from that batch; where they differ from the rows above, both are recorded rather than merged.Standard
Ranges in this batch0 to 1 m, 0 to 5 m, 0 to 10 m and 0 to 20 mStandard
Output4-20 mA, RS-485/Modbus, 0-10 V and 0-5 V all appear; RS-485 is the most common in this batchStandard
Supply24 V DC as the main form, with 12 V DC and battery-powered versions also listedStandard
Process connectionThreaded, flanged and M20 x 1.5 versionsStandard
Wetted materials316L stainless diaphragm and 304 stainless body, with polyurethane or PTFE cable and ceramic-capacitor sensing elementsStandard
Ingress protectionIP68 at the probeStandard

Available models

Selection table
Model Configuration Key ranges Availability
XK-136P Submersible hydrostatic level transmitter with a 316L diaphragm in a 304 stainless housing, on a vented cable, with voltage and serial output options 0 to 1 m, 0 to 3 m, 0 to 5 m and 0 to 10 m as standard, to 500 m to order; 0.5 class, 0.2 class to order; 4-20 mA; 24 V DC; probe IP68 and assembly IP65 One transmitter model. The control instrument offered alongside it carries no model designation in the material, so it is recorded under customisation rather than as a second model row

Customization

  • An anti-corrosion version, for media that the standard stainless probe is not compatible with
  • A high-temperature version, which the material states is required where the medium exceeds the standard limit
  • Output options of 0-5 V and RS-485 in addition to the standard 4-20 mA
  • Accuracy of 0.2 class in place of the standard 0.5 class
  • Ranges beyond the standard set, given in the material as up to 500 m
  • A control instrument with four relay contacts, supplied with the transmitter for display, alarm and pump control

Certification and compliance

Certification documents not yet supplied

Certifications are only published once a certificate copy can be produced, so this section is deliberately empty rather than populated with assumed approvals. Tell us which approvals your application requires and we will confirm what is available for this instrument.

Parameters still to be confirmed

The following are required for a complete specification but are not stated in the documentation supplied to us. They are listed rather than estimated:

  • Whether the working temperature is -10 to 40 °C as the parameter table gives or -20 to 40 °C as the order cards give, since both appear in the material
  • Whether the 0.5 % figure on the order cards is a resolution or an accuracy, since the table gives an accuracy class of 0.5 for the same instrument
  • The duration associated with the 150 % overload rating, which is given as a percentage without a time
  • The maximum cable length that can be supplied, and whether the cable may be extended on site without affecting the reading
  • The pressure and temperature limits of the anti-corrosion version
  • The inlet diameter quoted in the stilling arrangement, which the material prints as 45 cm in two places and which is large for the purpose
  • Whether the control instrument can be supplied separately, since the material states accessories must be ordered with the host
  • The relay contact rating of the control instrument
  • The weight of the probe and of the cable per metre
  • Whether the 500 m maximum range is a single order or a series of special builds
  • Warranty period and the terms that apply
  • An English-language datasheet, and a wiring diagram with a verified conductor legend

Frequently asked questions

What has to be settled before a submersible transmitter can be quoted?

The medium and its density first, because the instrument measures pressure and converts it to a level using that density, so a tank that holds different products or a liquid whose density moves with temperature will not give a level from one calibration. Then the depth to be measured, which fixes the range and shows how much of full scale the normal level uses. Then whether the vessel is open to atmosphere, since that decides whether a vented reference is enough or a differential arrangement is needed. Then the temperature, the chemical compatibility of the wetted materials, and whether the reading has to do anything - fill, empty or alarm - rather than only be displayed.

Why does the cable have a tube in it?

It keeps the sensor referenced to the atmosphere. The element inside the probe measures the pressure of the liquid above it, and without a reference it would also be measuring the pressure of the air in the vessel headspace and the barometric pressure of the day, so the reading would move with the weather. The vent tube runs inside the cable to the terminal, where it is left open to air, which makes the measurement a gauge pressure and therefore a level. It is also the one part of the installation that an installer can easily ruin, since a kinked, pinched or flooded tube produces a reading that drifts for reasons that are hard to see.

Can it be used in a sealed or pressurised tank?

Not as a single gauge transmitter, because a sealed vessel has no atmosphere to reference against and the headspace pressure would be added to the reading. Sealed and pressurised vessels are measured with a differential arrangement that compares the bottom of the tank with the top and cancels the headspace pressure. The form described here is for an open or freely vented vessel, which is the case for almost all of the duties it is bought for - a water tank, a sump, a pit, a reservoir or a river.

What happens when the water is turbulent or the tank is being stirred?

Nothing, and that is the advantage of measuring pressure rather than distance. The instrument sits at the bottom and reads the head of liquid above it, so foam, a slopping surface, floating debris and anything turning in the tank leave the reading essentially unchanged. What does disturb it is an inlet discharging directly onto the probe, because that adds velocity pressure to the static head and shows up as a reading that moves with the flow. The answer is a stilling arrangement, a shield or a different mounting point, and the material gives three of them - a perforated pipe, a fixing block on the floor, or reshaping the inlet so the stream does not land on the probe.

Related products

Other models in the same range

Integrated ultrasonic level meter standing upright with a translucent red top section, a grey threaded ring below it, a white body carrying two screened circular fittings on the front and the letters DC moulded beneath them, and a black lower section ending in the transducer face

SIN-MP-C (4 models) · Ultrasonic Level Meters

Ultrasonic Level Meter

Non-contact ultrasonic level meter for tanks, sumps, channels and silos, in integral and separate forms, with 4-20 mA and RS-485 outputs and a relay pair.

Model
SIN-MP-C / SIN-ULS-B / SIN-WSU100 / WSU200
Mounting
Non-contact, above the medium
Forms
Integral, with the transducer in the head, or separate, with the head and probe mounted apart
Range
0 to 1 m through to 0 to 15 m across the forms
Radar level meter with a blue cap over a stainless cylindrical housing carrying two cable entries and a cover screw, a black nameplate on the body, and a large stainless flange at the base drilled for bolts with a raised sealing face in the centre

MIK-RD908 (3 models) · Radar Level Meters

80 GHz Radar Level Meter

Radar level meter in 80 GHz, low-frequency and guided-wave series for tanks, silos, rivers and pressurised vessels, with spans from 10 m to 80 m.

Model
Fourteen models across three series, from MIK-RD908 to MIK-RD702
Series
80 GHz high-frequency, low-frequency, and guided-wave
Range
0 to 10 m through to 0 to 80 m, according to series and model
Accuracy
±5 mm on the shortest spans through to ±30 mm at a 70 m span

Request a quotation for the XK-136P

Send the configuration you need and we will confirm availability, lead time and terms. Minimum order quantity is 1 pc.

Request for quotation

Request a quotation - XK-136P

Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.

The more of this you can give us, the fewer exchanges are needed before we can quote.
No file chosen
Datasheet, drawing, BOM or photograph. One file, up to 10 MB (PDF, Office, image or ZIP).

By submitting this form you agree that we may contact you about this enquiry. We do not sell or share enquiry data. See our privacy policy.

Items held in stock are dispatched within 48 hours of order confirmation. Customized specifications are produced to order and typically ship within 2 to 10 days. Transit time then depends on the shipping method and destination.

Request a Quote WhatsApp