Process Analysis · Water Quality Analyzers

Multi-Parameter Water Quality Tester

Pen-type water quality tester reading COD, TOC, UV275, TDS, conductivity and temperature in one immersion, with a four-colour score display and an IP67 probe.

LS310 (2 models) ·

Key specifications

Parameters
COD, TOC, UV275, TDS, conductivity and temperature; LS311 adds salinity, hardness and specific gravity
Measuring range
COD 0 to 100 mg/L; TOC 0 to 100 mg/L; UV275 0 to 1.0 au/cm; TDS 0 to 2000 ppm; conductivity 0 to 4000 µS/cm; temperature 0 to 50 °C
Resolution
COD and TOC 0.01 mg/L; UV275 0.001 au/cm; TDS 1 ppm; conductivity 1 µS/cm; temperature 0.1 °C
Accuracy
COD and TOC ±0.5 mg/L below 5 mg/L and ±10% H above; TDS and conductivity ±3% FS; temperature ±1 °C
Display
1.14 inch TFT, 240 × 135, with a backlight in four colours keyed to the score band
Keys
Power and measure, two keys in total
Probe
Immersion sensor with a minimum water line marked on the body; IP67
Power
Two AAA alkaline cells
Body
157 × 37 × 14 mm, about 68 g
Environment
5 to 50 °C at up to 85% RH without condensation; storage −10 to 60 °C

Water quality is usually judged with a kit: a strip, a reagent, a meter for each parameter and a note of the results. The tester in this range replaces the kit with one immersion, and replaces the interpretation with a score.

Product overview

A pen with a sensor at the lower end and a small colour display on the front. Two keys, one of which measures.

Six quantities come out of a single immersion: the organic indicators, the ionic indicators and the temperature. The display shows them together and adds a score, with the backlight changing colour to match the band the score falls in.

The body is 68 g and fits a pocket. The probe is capped when not in use and has a marked minimum immersion line, so the same depth is used each time.

How the tester reads the water

The probe measures absorbance in the ultraviolet at 275 nm, which is where dissolved organic matter absorbs, and it measures the conductivity of the sample between electrodes. Temperature is measured at the same point and is used to compensate the ionic reading, because conductivity rises with temperature and a reading without compensation is a reading of the water plus the weather.

The organic figures are presented as COD, TOC and UV275. All three describe the same underlying question - how much oxidisable or ultraviolet-absorbing material is in the water - at different scales, which is why they move together and why a single one of them is a poor basis for a decision.

The score is what turns the readings into an answer. It is calculated across the parameters rather than from any one of them, and the colour of the backlight follows the band. That is deliberate: a water with a high mineral content reads badly on TDS alone but can be perfectly good to drink, and a water with low TDS can still carry an organic load.

How to select the right model

The base model covers the six parameters that describe drinking water: the organic load, the dissolved solids, the conductivity and the temperature.

The higher model adds salinity, hardness and specific gravity. Those are descriptive rather than diagnostic: they tell you what kind of water it is - how hard, how salty, how dense - rather than whether it is fit to drink.

The choice therefore follows the question being asked. A quick check of a tap or a filter output needs the six. Describing a mineral water, checking a softener, or comparing sources needs the additional three.

Neither model logs. If results have to be kept, they are written down or photographed; there is no memory and no export in the material.

Measurement limitations and selection considerations

The sample type is drinking water, not wastewater. The ranges are built around clean water, and a sample with a high organic load will sit at the top of the range rather than produce a useful figure. Effluent, process water and heavily polluted surface water need a different instrument.

Immersion depth and probe cleanliness decide the reading as much as the electronics. The minimum water line exists to make the depth repeatable, and a probe with a film on it - from a previous sample, from hard water, or from handling - reads the film as well as the water. Rinsing with the sample before measuring is part of the method, not an optional step.

The score is a summary and should be treated as one. It is a good way to sort many samples quickly; it is not a substitute for the individual readings when a result has to be defended, and it is not a compliance measurement against a drinking water standard. The reference standard behind the scoring is a benchmark, not a certificate.

Temperature compensation corrects the ionic reading, not the organic one. A cold sample and a warm sample of the same water will agree on conductivity after compensation but can differ slightly on the optical figures, so comparisons should be made at similar temperatures.

Features

  • Six parameters from one immersion, without reagents, strips or a separate conductivity meter
  • A score calculated from several parameters together rather than from TDS alone, which avoids judging a mineral water by its dissolved solids
  • A backlight that changes colour with the score band, so a result can be read at a glance and without interpreting numbers
  • Automatic temperature compensation, so a sample measured warm is not reported as a different water
  • An IP67 probe, which is the part that is actually immersed
  • A minimum water line marked on the body, so the immersion depth is repeatable between operators
  • A pen body at 68 g that fits a pocket, with a cap over the probe
  • Two keys in total, so a measurement is one press from off

Technical specifications

Every value below is taken from source documentation. Where a parameter is not stated in the available material it is marked as information required rather than estimated.

Measurement parameters
COD0 to 100 mg/LStandard
TOC0 to 100 mg/LStandard
UV2750 to 1.0 au/cm, the absorbance at 275 nmStandard
TDS0 to 2000 ppmStandard
Conductivity0 to 4000 µS/cmStandard
Temperature0 to 50 °CStandard
Salinity, hardness and specific gravityMeasured on LS311; ranges and accuracy not stated in the materialInformation required
Sample typeDrinking water: tap, treated, bottled, ground and surface water; not wastewaterStandard
Accuracy and resolution
COD accuracy±0.5 mg/L from 0 to 5 mg/L; ±10% H from 5 to 100 mg/L, H being the standard valueStandard
TOC accuracy±0.5 mg/L from 0 to 5 mg/L; ±10% H from 5 to 100 mg/L, H being the standard valueStandard
UV275 accuracy±0.01 au/cm from 0 to 0.1 au/cm; ±10% H from 0.1 to 1.0 au/cmStandard
TDS accuracy±3% FS, FS being the full-scale valueStandard
Conductivity accuracy±3% FS, FS being the full-scale valueStandard
Temperature accuracy±1 °CStandard
ResolutionCOD and TOC 0.01 mg/L; UV275 0.001 au/cm; TDS 1 ppm; conductivity 1 µS/cm; temperature 0.1 °CStandard
Temperature compensationAutomatic compensation by ambient and sample temperatureStandard
Display and control
Screen1.14 inch TFT, 240 × 135, backlitStandard
Backlight coloursBlue, green, yellow and red, keyed to the score bandStandard
KeysPower and measureStandard
ScoringA score is calculated from several parameters together, and the band is shown with the colour; the reference is the GB 5749-2022 drinking water standardStandard
Score bands90 to 100 blue; 80 to 90 green; 60 to 80 yellow; 0 to 60 redStandard
Body and environment
Dimensions157 × 37 × 14 mmStandard
WeightAbout 68 gStandard
StructureBattery cover at the top, display, two keys, sensor probe at the lower end, cap and a minimum water lineStandard
Probe protectionIP67Standard
SupplyTwo AAA alkaline cellsStandard
Operating environment5 to 50 °C at up to 85% RH without condensationStandard
Storage environment−10 to 60 °C at up to 85% RH without condensationStandard

Available models

Selection table
Model Configuration Key ranges Availability
LS310 Pen-type tester with the six base parameters COD, TOC, UV275, TDS, conductivity and temperature The base model
LS311 The same body with three additional parameters The six base parameters plus salinity, hardness and specific gravity; ranges and accuracy not stated in the material For water where the mineral content has to be described as well as scored

Certification and compliance

Certification documents not yet supplied

Certifications are only published once a certificate copy can be produced, so this section is deliberately empty rather than populated with assumed approvals. Tell us which approvals your application requires and we will confirm what is available for this instrument.

Parameters still to be confirmed

The following are required for a complete specification but are not stated in the documentation supplied to us. They are listed rather than estimated:

  • The ranges and accuracy of the salinity, hardness and specific gravity measurements on LS311, which the material mentions without figures
  • The calibration procedure and the recommended interval, which the material describes only as simple and permitting a long period between calibrations
  • Whether a calibration solution or reference is supplied
  • The contents of the shipping carton, which the material does not give
  • The measurement principle behind the COD and TOC figures, and whether they are derived from the 275 nm absorbance or measured separately
  • The battery life, which the material describes only as long standby
  • The ingress protection of the body as distinct from the probe, which alone is rated IP67
  • The conformity standards the instrument is built to, beyond the GB 5749-2022 reference used for scoring
  • Whether a calibration certificate is supplied
  • Warranty period and its terms
  • Whether the display and the instructions are available in English

Frequently asked questions

Can this tester be used on wastewater or effluent?

No. The material limits the sample type to drinking water - tap, treated, bottled, ground and surface water - and states that wastewater is outside its scope. The ranges and the scoring are built around a clean water baseline, so a sample with a high organic load will sit above the range rather than give a useful number.

Why score several parameters instead of reading TDS alone?

Because dissolved solids do not distinguish between water that is mineral-rich and water that is contaminated. A single TDS reading flags a good mineral water as poor and can miss an organic load that barely changes conductivity. Combining the organic indicators with the ionic and thermal readings gives a result that follows the intended use of the water rather than one number.

What do the four colours mean?

They are bands of the calculated score, not of any single parameter: blue for the highest band, then green, yellow and red as the score falls. The material gives the score ranges and, separately, the parameter values that correspond to each colour for COD, TOC and TDS. The colour is a summary, so the individual readings should still be read when a result matters.

What is needed before a quotation?

The type of water to be checked and whether it is drinking water at all; the parameters that have to be recorded, since salinity, hardness and specific gravity are only on the higher model; whether readings have to be written down or exported, since the tester displays but does not log; and the number of units and whether they are for field use or for a bottling line.

Related products

Other models in the same range

A panel-mount controller in a black enclosure with a colour graphic display, showing a live measurement with a temperature and a current output value, six keys along the lower edge and two indicator lamps

FK-EC480 (11 models) · Conductivity Analyzers

Online Conductivity Analyzer

Panel-mount online conductivity analyzer covering ultrapure water to brine, with automatic or manual temperature compensation, isolated current outputs, relays and a serial port, and a choice of contact or inductive electrodes.

Range
Set by the electrode cell constant: about 0 to 20 microsiemens per centimetre at a constant of 0.01, up to 0 to 600 millisiemens per centimetre on the high specification controller
Accuracy
Stated as 2.0 class on the flagship and high specification controllers and as 1.5 percent of full scale on the compact controller
Temperature
minus 10.0 to 130.0 degrees Celsius, with automatic or manual compensation
Temperature elements
NTC10K, Pt1000, NTC30K or Pt100 depending on the controller, matched to the element fitted in the electrode
Hand-held pen shaped pH meter with a light grey body, a dark grey cap at the top and a tapered probe at the foot, its display showing 7.49 pH above a reading of 30.1 degrees Celsius, with three buttons below the screen

PH848 (5 models) · pH Meters

Pen Type pH Meter

Pen type pH meters in five models across two accuracy grades, with the electrode and the display in one hand-held body, automatic temperature compensation and a selectable probe form.

Models
PH848, PH838, PH818, PH828 and PH828+ across two accuracy grades
pH range
0.0~14.0 on PH848; 0.00~14.00 on PH838, PH818, PH828 and PH828+
Resolution and accuracy
0.1 resolution at ±0.1 pH on PH848; 0.01 resolution at ±0.05 pH on the other four
Repeatability
0.1 on PH848; 0.03 on the other four

Request a quotation for the LS310

Send the configuration you need and we will confirm availability, lead time and terms. Minimum order quantity is 1 pc.

Request for quotation

Request a quotation - LS310

Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.

The more of this you can give us, the fewer exchanges are needed before we can quote.
No file chosen
Datasheet, drawing, BOM or photograph. One file, up to 10 MB (PDF, Office, image or ZIP).

By submitting this form you agree that we may contact you about this enquiry. We do not sell or share enquiry data. See our privacy policy.

Items held in stock are dispatched within 48 hours of order confirmation. Customized specifications are produced to order and typically ship within 2 to 10 days. Transit time then depends on the shipping method and destination.

Request a Quote WhatsApp