Industrial Automation & Control · PLC Systems

PLC and HMI All-in-One Controller

Programmable logic controllers with an integrated touch screen, in 4.3, 7 and 10 inch formats, combining discrete and analogue I/O, PT100 inputs, high-speed counting and relay outputs in one panel unit.

AMX-HM ·

Key specifications

Screen sizes
4.3, 7 and 10 inch
Discrete inputs
8, 16 or 24, depending on model
Discrete outputs
8, 16 or 22, depending on model
Analogue I/O
4 inputs and 2 outputs on the models that carry them
PT100 inputs
2 channels on the models that carry them
High-speed counting
Up to 200 kHz; 6 single-phase or 4 AB-phase channels
High-speed pulse output
2 channels, 100 kHz
Communication
Ethernet, USB, RS-485, RS-232; 4G or Wi-Fi on some models
Supply
24 VDC on the models that specify it
Relay capacity
2.0 A per output point, 8.0 A per common terminal

A PLC and HMI all-in-one controller puts the programmable logic controller and the operator touch screen into one panel unit. On a small or medium machine this removes a component from the cabinet, the wiring between the two, and a second panel cut-out, which is the reason the format exists rather than being a packaging preference.

The units on this page cover screen sizes of 4.3, 7 and 10 inches, with cut-outs from 120×94 mm to 260×202 mm. Discrete I/O runs from 8 inputs and 8 outputs up to 24 inputs and 22 outputs by model. Analogue input and output, two PT100 channels, high-speed counting to 200 kHz and two 100 kHz pulse outputs are carried on the models that specify them, so the configuration is decided by what the machine has to do rather than by what the housing can hold.

Two instruction-set families are offered. The H series is compatible with 3U instructions and the HS series with 200 instructions. They are separate families, so a program written for one does not move to the other unchanged.

How a PLC and HMI all-in-one controller works

The logic part of the unit reads its inputs, runs the stored program, and writes its outputs in a repeating scan. What makes the scan dependable in a machine is not its speed but the isolation on the way in and out: every I/O point on these units is opto-isolated, so a transient picked up on a sensor cable does not reach the processor as a change of state. Inputs accept a positive or a negative trigger, which is what allows a sinking or a sourcing sensor to be connected without an interface.

The screen is not a display bolted to the front. It reads and writes the same registers the program uses, so a setpoint entered on the screen is the value the logic acts on, with no separate link to configure. Temperature from a PT100 reaches the program through the same arrangement, which is what allows a temperature loop to be closed inside the unit without a separate transmitter and a separate analogue input.

Relay outputs are the part that decides how much can be switched. Each point carries a maximum current and each common terminal carries a maximum for the group it feeds, and both apply at once: four points at their individual limit reach the limit of the common. Inductive loads draw a surge on break, which is why they are normally switched through an interposing relay rather than directly.

How to select the right unit

Begin with the screen. The size is set partly by how much has to be legible at once and partly by the cut-out the enclosure already has; a cut-out cannot be enlarged without remaking the panel, so it is usually the fixed constraint. The cut-out dimensions for this series are listed above and they differ enough between the sizes to be worth checking before choosing.

Then count the I/O. Discrete inputs and outputs are chosen by model, so the count is what selects the part rather than an expansion module. Where the machine needs analogue signals, or a PT100 directly, that narrows the choice further, because those channels are carried only on the models that list them.

Then decide on counting and communication. Encoders and positioning axis determine whether high-speed counting and pulse output are needed. For communication, the unit offers Ethernet, USB, RS-485 and RS-232 by model, with 4G or Wi-Fi on the models marked for it, and the two instruction-set families are separate, so an existing program is the constraint that decides which family is chosen.

State the screen size, the I/O count, whether analogue or PT100 is needed, whether counting is needed and what the unit has to talk to, and the model follows.

Limitations and points to confirm

This unit is a controller and an operator interface. It is not a safety device: none of the published figures describe a safety-rated input, a dual-channel architecture or a diagnostic coverage level, so an emergency stop, a guard interlock or a light curtain has to be implemented with dedicated safety hardware rather than through the program. The EMC figures quoted here are immunity levels, not a statement about functional safety.

Two parts of the supplied material are incomplete and are published as such rather than filled in. The HS series is named, but its model table is not included, so the individual codes for that family are not listed. And the protocols are given as a list alongside the ports without stating which protocol runs on which port; on a machine that has to join an existing network, that mapping should be confirmed before the order rather than at commissioning.

Several figures a specification often calls for are absent from the document and appear here as information required: program capacity, power-fail retention time, ingress protection, operating temperature and dielectric strength. The relay capacity is published as stated, at a maximum current per point and per common, and is not a load rating for an inductive load.

Before ordering, note that the meaning of the model suffixes is not defined in the supplied material. Where a particular suffix is wanted for a particular reason, ask for it by name and describe the behaviour needed, so the two can be matched rather than assumed.

Features

  • A programmable controller and an operator touch screen in one panel unit, which removes the cable and the separate cut-out that two units would need
  • Cut-outs from 120×94 to 260×202 mm, covering 4.3, 7 and 10 inch screens from the same series
  • Discrete I/O from 8 inputs and 8 outputs up to 24 inputs and 22 outputs, chosen by model rather than by expansion module
  • Analogue I/O and two PT100 channels available on the models that carry them, so a temperature loop can be closed without a separate transmitter
  • High-speed counting to 200 kHz and two 100 kHz pulse outputs, for encoders and for stepper or servo positioning
  • Opto-isolated I/O on every point, with power-fail retention and reverse-polarity protection
  • Ethernet, USB, RS-485 and RS-232 on the higher models, with 4G or Wi-Fi on the models marked for it
  • A real-time clock, so the program can act on time of day

Technical specifications

Every value below is taken from source documentation. Where a parameter is not stated in the available material it is marked as information required rather than estimated.

Display and housing
4.3 inch screen480×272; outline 128×102×36 mm; cut-out 120×94 mm; backlight over 20,000 hStandard
7 inch screen800×480; outline 212×157×41 mm; cut-out 192×138 mm; backlight over 30,000 hStandard
10 inch screen1024×600; outline 272×215×43 mm; cut-out 260×202 mm; backlight over 30,000 hStandard
MountingPanel cut-out or bracket mountStandard
Housing materialFlame-retardant, as stated in the supplied documentStandard
Backlight lifeA consumable part; the quoted hours apply to the backlight, not to the unitStandard
Control and I/O
Instruction set, H seriesCompatible with 3U instructionsStandard
Instruction set, HS seriesCompatible with 200 instructions; the model table for this series is not included in the supplied documentInformation required
Discrete inputs8, 16 or 24 points by modelStandard
Discrete outputs8, 16 or 22 relay points by modelStandard
Analogue inputs4 channels on models carrying analogue I/OStandard
Analogue outputs2 channels on models carrying analogue I/OStandard
PT100 inputs2 channels on models carrying temperature inputStandard
High-speed countingUp to 200 kHz; 6 single-phase or 4 AB-phase channels by modelStandard
High-speed pulse output2 channels at 100 kHzStandard
IsolationOpto-isolated on every I/O point; inputs accept positive or negative triggerStandard
Retentive memoryPower-fail retention stated; duration not givenInformation required
Program capacityInformation requiredInformation required
Communication
PortsEthernet, USB, RS-485 and RS-232, by modelStandard
Wireless4G or Wi-Fi on the models marked for itOptional
Ethernet protocolsS7TCP, GET, PUT, OUC, ModbusTCPStandard
Serial protocolsPPI, free port, ModbusRTUStandard
Protocol to port mappingInformation required; the document lists the protocols without stating which port carries eachInformation required
Electrical and environmental
Supply24 VDC on the models that specify itStandard
Relay capacity per point2.0 A maximumStandard
Relay capacity per common8.0 A maximumStandard
EMC, air dischargeLevel 3, ±8 kVStandard
EMC, contact dischargeLevel 2, ±4 kVStandard
EMC, fast transient burstLevel 3, ±2 kVStandard
Reverse-polarity protectionProvidedStandard
Operating temperatureInformation requiredInformation required
Ingress protectionInformation requiredInformation required
Dielectric strengthInformation requiredInformation required

Available models

Selection table
Model Configuration Key ranges Availability
AMX-HM4A 4.3 inch screen 8 discrete inputs, 8 outputs; analogue I/O and PT100 on some variants Cut-out 120×94 mm
AMX-HM7 and AMX-HM7A 7 inch screen 8 or 16 inputs, 8 outputs; up to 24 inputs and 22 outputs on the higher variants Cut-out 192×138 mm; analogue and PT100 on the A variants
AMX-HM10A 10 inch screen 16 inputs, 16 outputs; analogue I/O and PT100 Cut-out 260×202 mm
AMX-HM7A-32MRTG and AMX-HM10A-32MRTG 7 and 10 inch, wireless variants 16 inputs, 16 outputs, analogue I/O and PT100 Marked for 4G or Wi-Fi; the meaning of the G and W suffixes is not defined in the supplied document
HS series 200-instruction compatibility Not stated The supplied document names the series but does not include its model table

Certification and compliance

Certification documents not yet supplied

Certifications are only published once a certificate copy can be produced, so this section is deliberately empty rather than populated with assumed approvals. Tell us which approvals your application requires and we will confirm what is available for this instrument.

Parameters still to be confirmed

The following are required for a complete specification but are not stated in the documentation supplied to us. They are listed rather than estimated:

  • Model table for the HS series, which the supplied document names but does not detail
  • Meaning of the G and W model suffixes
  • Which communication port carries each listed protocol
  • Program capacity
  • Power-fail retention time
  • Operating temperature range
  • Ingress protection of the front face and of the case
  • Dielectric strength
  • Certification list and availability of certificate copies
  • Warranty period and the terms that apply
  • English-language datasheet, programming manual and dimension drawings in PDF form
  • Packaging dimensions and gross weight for freight calculation
  • Whether the analogue and PT100 variants can be combined on one model

Frequently asked questions

What has to be decided before a model can be quoted?

Four things: the screen size, which is usually set by how much has to be shown and by the panel cut-out already available; the number of discrete inputs and outputs; whether analogue I/O or PT100 inputs are needed, because those are carried only on some models; and whether the machine needs high-speed counting or pulse output for positioning. State all four and the model follows. Where a feature is not needed, saying so is as useful as saying what is, since the analogue and temperature variants are a different part.

Is one of these enough for a machine, or is a separate PLC still needed?

For a small or medium machine it is normally enough on its own. The logic runs in the same housing as the screen, which is the point of the format: fewer components in the cabinet, less wiring, and one cut-out instead of two. Where the machine needs more I/O than the largest model carries, a much faster scan time, or motion control beyond the two pulse outputs, a separate controller is the better arrangement and this unit becomes the operator screen.

Which communication port carries which protocol?

The supplied document lists the protocols and the ports separately but does not state which protocol runs on which port, so that mapping is confirmed at order rather than assumed here. The Ethernet protocols listed are S7TCP, GET, PUT, OUC and ModbusTCP, and the serial protocols are PPI, free port and ModbusRTU. If the controllers have to join an existing network, tell us what the network runs and we will confirm the port and the configuration before the order.

What happens to a relay output point when several are energised at once?

Two limits apply at the same time and both have to be checked. Each output point can carry 2.0 A, and the common terminal that feeds a group of points can carry 8.0 A in total. A group of four points each drawing 2.0 A already reaches the common limit, even though no single point is overloaded. Inductive loads such as solenoids draw a higher current on break than their nominal figure, so they are normally switched through an interposing relay.

Are the two instruction-set families interchangeable?

They are separate families, not two configurations of the same one: the H series is compatible with 3U instructions and the HS series with 200 instructions. Programs are therefore not portable between them without being rewritten. The model table for the HS series was not included in the material supplied for this page, so if that family is of interest, ask for the complete selection table before choosing.

Request a quotation for the AMX-HM

Send the configuration you need and we will confirm availability, lead time and terms. Minimum order quantity is 1 pc.

Request for quotation

Request a quotation - AMX-HM

Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.

The more of this you can give us, the fewer exchanges are needed before we can quote.
No file chosen
Datasheet, drawing, BOM or photograph. One file, up to 10 MB (PDF, Office, image or ZIP).

By submitting this form you agree that we may contact you about this enquiry. We do not sell or share enquiry data. See our privacy policy.

Items held in stock are dispatched within 48 hours of order confirmation. Customized specifications are produced to order and typically ship within 2 to 10 days. Transit time then depends on the shipping method and destination.

Request a Quote WhatsApp