A pressure calibrator generates or measures a known pressure so that another instrument can be checked against it. It is the reference in the comparison, not the instrument under test, and the whole value of the exercise depends on the calibrator being more accurate than the device being checked by a known margin.

What a pressure calibrator is

A pressure calibrator generates or measures a known pressure so that another instrument can be checked against it. It is the reference in the comparison, not the instrument under test, and the whole value of the exercise depends on the calibrator being more accurate than the device being checked by a known margin.

Two figures decide the choice. The first is the pressure range, which has to cover the device under test without the calibrator working at the very bottom of its own span. The second is the accuracy statement, and how it is expressed matters as much as its size: a figure quoted against full scale represents the same absolute uncertainty at any point in the range, while one quoted against the reading becomes smaller as the pressure falls. On a device tested across its range, that difference changes the verdict.

Many duties also have an electrical side. A pressure transmitter produces an output proportional to pressure, so checking it means applying a pressure and reading the resulting signal - and often supplying the loop while measuring the current as well. Instruments that combine the two functions cover that in one pass; instruments that do not need a second device alongside them.

How a pressure calibrator measures

The reference inside the calibrator is a pressure sensor of known quality, and the calibration chain runs from a national standard through successive comparisons to that sensor. The certificate supplied with the instrument records what the sensor was found to be at the time of comparison, so the uncertainty of the calibrator is an input into the uncertainty of every check made with it.

How the pressure is generated is a separate question from how it is measured. A hand pump built into the instrument, an electric pump, or an external supply all produce the pressure; the calibrator reads it. The medium matters at the same time: pneumatic generation suits lower pressures and clean dry gas, while hydraulic generation is used at higher pressures, where compressed gas would store too much energy to be safe.

The comparison is only as good as the ratio between the two uncertainties. Where the calibrator is only slightly more accurate than the device being checked, an apparent pass or fail at the tolerance limit cannot be relied on, because the measurement uncertainty overlaps the tolerance itself. That ratio is a criterion in most quality systems, and it sets a floor on the calibrator long before convenience does.

Configuration choices

Most of the specification is fixed by these decisions rather than by the accuracy class. Each one constrains the next, which is why they are settled in order.

ConfigurationOptions to fixWhat it actually decides
Pressure range and number of ranges A single span, or several selectable rangesWhether the device under test sits comfortably inside the range or at the bottom of it, where the relative uncertainty is largest.
Accuracy statement and its form A figure quoted against full scale, or against the readingThe absolute uncertainty at the point being tested. The two forms diverge most at low pressures, which is where the choice usually matters.
Internal or external pressure reference A sensor built into the instrument, or an interchangeable moduleWhether one instrument can cover several ranges, and whether the reference can be exchanged or recalibrated on its own.
Pressure generation A hand pump, an electric pump, or an external supplyHow the pressure is produced and how much effort the test takes. An electric pump reduces operator effort over a long sequence.
Pressure medium Pneumatic for lower pressures, hydraulic for higher onesThe energy stored in the system and the safety of the work, as well as whether the device under test is a gas or a liquid pressure instrument.
Electrical measurement and sourcing The ability to read and generate current, voltage and resistance signalsWhether a transmitter can be checked end to end in one pass, and whether the loop can be energised from the calibrator.
Loop supply Whether the instrument can power a two-wire transmitterWhether the device under test has to be powered separately while it is being checked.
Documentation and logging Whether readings can be stored and certificates generatedWhether the calibration record is produced automatically or assembled by hand, which on a large instrument list is the difference between a day and a week.

How to choose a pressure calibrator

FactorWhy it decides the answerHow to settle it before enquiring
Accuracy ratio against the device under test The calibrator has to be more accurate than the tolerance by a defined margin for the result to mean anythingGive the tolerance on the device, and the ratio the quality system requires.
Pressure range of the devices A device tested across its range should not sit at the very bottom of the calibrator’s spanGive the range and the test points, including the lowest one.
Whether vacuum is needed Not every generation method reaches a vacuum, and some devices are tested below atmosphericState whether vacuum or negative gauge pressure forms part of the test.
The electrical side of the test Transmitters, switches and indicators each require something different from the calibratorDescribe what is being checked: a gauge, a transmitter with an output, a switch, or a loop.
Pressure medium and safety The stored energy at the test pressure decides whether pneumatic generation is acceptableState the pressure to be reached, and whether the device contains gas or liquid.
Where the work is done A workshop bench and a plant location impose different requirements on size, power and portabilityState whether calibration is a bench activity or is performed in the field.
Certificate requirement A traceable certificate for the calibrator, and a record for each device checkedState what has to be issued, and to what standard.

If any of these are still open, send what is known. A quotation can be issued against a duty description and refined once the gaps are filled.

The nearest alternatives

These are the types an enquiry for a pressure calibrator usually turns out to be, and the point at which the choice is genuinely decided.

Nearest alternativeWhat separates it from a pressure calibrator
Multifunction calibrators Cover pressure alongside temperature and electrical signals in one instrument, which suits a team working through a mixed instrument list. The trade is usually in the pressure specification at a given cost, so where pressure is the dominant duty a dedicated instrument may represent better value.
Process calibrators Built around the loop rather than around pressure: sourcing and reading the standard process signals, and often supplying the loop. Where the task is checking a transmitter’s output rather than its pressure element, the process calibrator is the instrument and pressure may not be needed at all.
Temperature calibrators Provide a controlled temperature as the reference, which is a different physical quantity and a different generation problem. Pressure and temperature are frequently both needed on one instrument list, and neither instrument replaces the other.
Electrical calibrators Produce and measure electrical quantities against a reference standard, and are what a loop check is built on. A pressure calibrator with electrical functions overlaps that ground partially; where the electrical work stands alone, a dedicated instrument is the better choice.
Calibration pumps Generate pressure without providing the reference measurement, and are used together with a separate gauge or calibrator. Where a reference instrument is already held, a pump alone is enough; where it is not, a combined instrument is the practical route.
Pressure test pumps Produce a pressure for a proof or leak test rather than for a calibration. The purpose is to demonstrate that a system holds pressure rather than to compare a reading against a reference, so the accuracy demand is quite different.

The commonest error here is choosing on range alone. A calibrator that covers the pressure but is barely more accurate than the device under test cannot produce a result that stands up, however convenient it is to use.

What to include in the enquiry

The first reply can be a quotation rather than a set of questions if the enquiry carries these. Where a figure is not known, send the duty description and we will confirm what it implies.

  1. The device under test: type, range, output and tolerance
  2. The accuracy ratio required by the quality system
  3. Test points, including the lowest pressure to be checked
  4. Whether vacuum or negative gauge pressure is involved
  5. Whether an electrical output has to be measured, sourced or supplied
  6. Maximum pressure to be reached, and whether generation is pneumatic or hydraulic
  7. Whether the work is on a bench or in the field
  8. What certificates or records have to be issued
  9. Quantity, destination port and required delivery date

Available products

1 model in Pressure Calibrators

Silver metal calibrator with a green LCD window above a row of membrane keys, a carrying handle, two large knurled knobs on the body and a transparent water cup on top

YPR-YBS-WY · Pressure Calibrators

Portable Pressure Calibrator

Battery-powered pressure calibrator with an integral hand pump, a 24 VDC loop supply and simultaneous pressure and current display, covering vacuum to 60 MPa including hydraulic ranges.

Pressure ranges
-95 kPa to 250 kPa; 0-1.6 MPa; 0-2.5 MPa; -95 kPa to 2.5 MPa; 0-4 MPa
Hydraulic ranges
0-16, 0-25, 0-40 and 0-60 MPa with the supplied water cup
Accuracy
0.05 grade basic; pressure 0.1%FS and 0.05%FS; current 0.05% ±1 digit
Resolution
10 Pa minimum pneumatically; 1 kPa minimum on the hydraulic ranges; 1 µA on current

Also in Calibration & Metrology

Other product types in this category

Every type we quote for under Calibration & Metrology. A type with no link yet is still quoted for - it is described on the Calibration & Metrology overview, and gets a page of its own as soon as a model is published against it.

Frequently asked

Pressure Calibrators questions

What accuracy do I need in a calibrator?

It follows from the tolerance on the device under test and the ratio your quality system requires between the two. A common convention is several to one, meaning the calibrator’s uncertainty is a small fraction of the tolerance being checked. A calibrator that is only marginally more accurate than the device under test produces results that cannot be relied on at the limit - which is exactly where the decision is being made.

What is the difference between a percentage of full scale and a percentage of reading?

A full-scale figure is a fixed absolute uncertainty whatever pressure is applied, so it becomes a large relative error at low pressures. A reading figure scales with the pressure and stays proportionate. On a device tested across its whole range, the difference decides whether the low end of the test means anything.

Do I need a pump in the calibrator?

Only if the pressure has to be generated as well as measured. Where a pressure source already exists, or where the calibrator is used with a separate pump, the instrument alone is enough. An integrated pump makes the test a single-person operation, which is often the reason it is chosen, and it adds weight and cost to the instrument.

Can it check a transmitter, not just a gauge?

It can if it measures the transmitter’s output as well as the pressure. Checking a transmitter means applying a pressure and reading the resulting signal, and usually supplying the loop as well. An instrument with the electrical functions covers that in one pass; without them, the pressure and the signal are read on two devices, which slows the work and adds a second uncertainty to every result.

Quoting for Pressure Calibrators

Send the specification and we will confirm the matching model, availability and lead time. Minimum order quantity is 1 pc.

Request for quotation

Request a quotation - Pressure Calibrators

Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.

The more of this you can give us, the fewer exchanges are needed before we can quote.
No file chosen
Datasheet, drawing, BOM or photograph. One file, up to 10 MB (PDF, Office, image or ZIP).

By submitting this form you agree that we may contact you about this enquiry. We do not sell or share enquiry data. See our privacy policy.

Items held in stock are dispatched within 48 hours of order confirmation. Customized specifications are produced to order and typically ship within 2 to 10 days. Transit time then depends on the shipping method and destination.

Request a Quote WhatsApp