Calibration & Metrology · Pressure Calibrators

Portable Pressure Calibrator

Battery-powered pressure calibrator with an integral hand pump, a 24 VDC loop supply and simultaneous pressure and current display, covering vacuum to 60 MPa including hydraulic ranges.

YPR-YBS-WY ·

Key specifications

Pressure ranges
-95 kPa to 250 kPa; 0-1.6 MPa; 0-2.5 MPa; -95 kPa to 2.5 MPa; 0-4 MPa
Hydraulic ranges
0-16, 0-25, 0-40 and 0-60 MPa with the supplied water cup
Accuracy
0.05 grade basic; pressure 0.1%FS and 0.05%FS; current 0.05% ±1 digit
Resolution
10 Pa minimum pneumatically; 1 kPa minimum on the hydraulic ranges; 1 µA on current
Current range
0-22 mA, with a 24 VDC output to supply the loop
Integral hand pump
-90 kPa to 1.6 MPa, 95% vacuum rate, IP54 sealing
Display
Backlit LCD showing pressure and current together, with mmH₂O and kg conversion and current percentage
Battery
One charge stated as 15 hours of operation; charges from 220 VAC through an external supply
Dimensions and weight
240 × 80 × 40 mm, 2.5 kg
Overload
1.2 to 1.5 times the range upper limit

A pressure calibrator is the reference in a comparison, not the instrument under test. It generates or measures a pressure of known value so that another instrument can be checked against it, and the whole exercise depends on the calibrator being more accurate than the device being checked by a margin the quality system accepts. The instrument on this page does that in the field, with an integral hand pump, a 24 VDC loop supply and a battery stated at 15 hours per charge.

Pressure and current are shown together on one display, which is what makes it useful for a two-wire transmitter: the pump applies the pressure while the calibrator supplies the loop and reads the current the transmitter returns, so a verification point and its corresponding output can be read off at the same time rather than in two passes.

How a pressure calibrator is used

The calibrator’s own sensor is the reference, and its accuracy is traced back through successive comparisons to a national standard. The document states that this instrument was verified to JJG875-2005 with a conforming result at 0.05 grade. What the certificate records is the state of the sensor at the time of comparison, which is why the calibrator’s uncertainty is an input into the uncertainty of every check made with it, and why the interval between recalibrations matters as much as the accuracy figure.

Pressure is generated by the hand pump and trimmed to the point being checked. The pump on this instrument covers -90 kPa to 1.6 MPa and reaches a 95% vacuum, and a volumetric trim lets the pressure be brought to a figure without overshooting it. On the five pneumatic ranges the reading resolves to 10 Pa, which is what allows a fine verification point to be set rather than approached.

The electrical side runs in parallel. The rear panel provides 24 VDC to the device under test and terminals for its current, so a transmitter can be powered and read from the same instrument that is applying the pressure. The display shows pressure, current, and the current as a percentage of the 4-20 mA span.

How to select the right calibrator

The pressure range comes first, and it has to cover the device under test without working at the bottom of its own span, where the relative uncertainty is largest. The pneumatic ranges run from a 250 kPa span to 4 MPa, the compound range crosses zero to -95 kPa, and the hydraulic ranges extend to 60 MPa. A device checked across its own range needs a calibrator whose range brackets it, not one that merely reaches its maximum.

Accuracy comes second, and how it is expressed matters as much as its size. This instrument carries a 0.05 grade, with pressure accuracy stated as 0.1%FS and 0.05%FS, so the figure that applies to a specific range has to be established before a ratio against a device under test can be calculated. Where the device under test is specified at 0.5%FS there is room; where it is specified at 0.1%FS the choice of range and the accuracy of that range decide whether the verification means anything.

Then the generation method. Pneumatic generation suits lower pressures and clean dry gas. Hydraulic generation, using pure water in the supplied cup, is used above 4 MPa because a compressed gas at those pressures stores too much energy to release safely, and it costs resolution: 1 kPa rather than 10 Pa.

Working with the hand pump and the hydraulic ranges

Two details separate a calibrator that is straightforward to use from one that is not. The first is the positive and negative switching valve, which is fitted to the small ranges and not to the larger instruments, which have a single output port. Compound work therefore needs the smaller instrument, and the valve has to be in the right position before pressure is applied rather than after. The second is that this is a static system: the pressure falls fairly quickly once it is at full scale, so the documented approach is to pressurise past the point until the over-range alarm holds, wait two to three minutes for the reading to settle, and then trim slowly, adjusting up and down a few times.

Both are also reasons to respect the medium. The sensor diaphragm is thin, so solid particles must not be allowed into the pressure output port, and liquid must not be drawn into the pneumatic system on a vacuum duty, since either can end the sensor rather than the measurement.

Measurement limitations and selection considerations

The overload capability is 1.2 to 1.5 times the range upper limit, with an audible and visual over-range alarm, and the alarm is there to be obeyed rather than tolerated: past the limit the sensor can be permanently damaged. Working pressure also needs the same care in the other direction, since a calibrator used well below its own full scale reports a larger relative uncertainty at the point being checked.

The environment is limited to 80%RH or less, and the operating temperature range is not stated in the material, so a hot or cold site is a question for the enquiry. Where the calibration is performed in a laboratory with an external pressure source, a bench instrument with an interchangeable reference module may cover more ranges than a hand-pumped portable, and where the requirement is a record rather than a check, the documentation has to be established before the instrument is chosen.

The instrument is also not a pressure source for a pressure test. Holding a pipe run at a test pressure for hours and generating a verification point are different duties with different needs, and a test pump is the instrument for the first.

Ordering

A quotation needs the range and whether pneumatic or hydraulic operation is required, the connection on the device under test, the electrical arrangement of that device if its current is to be read, and whether a calibration certificate is needed and to what accuracy. If the instrument is to be verified against a named regulation, state which one, since verification is against a regulation rather than against an accuracy figure in the abstract.

Features

  • A hand pump built into the instrument, so a verification can be carried out at the plant without carrying a separate pressure source
  • A 24 VDC output that supplies a transmitter under test while the resulting current is displayed, which lets a two-wire loop be checked in one pass
  • Simultaneous display of pressure and current, with the current also readable as a percentage of the 4-20 mA span
  • Five pneumatic range options from a 250 kPa span to 4 MPa, plus hydraulic ranges to 60 MPa with the supplied water cup
  • 10 Pa resolution on the pneumatic ranges, which is what makes a fine verification point reachable
  • A volumetric trim adjustment for approaching a set point without overshooting it
  • Battery operation stated at 15 hours per charge, with the charger built into the case rather than a separate unit
  • Over-range and over-current alarms, with a buzzer, so a verification does not continue past what the sensor can survive

Technical specifications

Every value below is taken from source documentation. Where a parameter is not stated in the available material it is marked as information required rather than estimated.

Measurement
Pneumatic ranges-95 kPa to 250 kPa; 0-1.6 MPa; 0-2.5 MPa; -95 kPa to 2.5 MPa; 0-4 MPaStandard
Hydraulic ranges0-16, 0-25, 0-40 and 0-60 MPaStandard
Basic accuracy0.05 gradeStandard
Pressure accuracy0.1%FS and 0.05%FS both stated — see the note on how the two entries relateInformation required
Current accuracy0.05% ±1 digitStandard
Pressure resolutionMinimum 10 Pa on the pneumatic ranges; minimum 1 kPa on the hydraulic rangesStandard
Current resolutionMinimum 1 µAStandard
Current measurement range0-22 mAStandard
Overload capability1.2 to 1.5 times the range upper limitStandard
VerificationThe document states the instrument was verified to JJG875-2005 with a conforming result at 0.05 grade; the certificate number and issuing body were excluded at sourceStandard
Pressure generation
Hand pump range-90 kPa to 1.6 MPaStandard
Vacuum rate95%Standard
Pump sealingIP54Standard
Fine adjustmentVolumetric trim, for reaching a set verification pointStandard
Device under test connectionM20×1.5 internal threadStandard
Positive and negative switching valveFitted to the small ranges; the larger instruments have a single output port and no switching valveStandard
Hydraulic operationRequires pure water in the supplied cup; 1 kPa resolution rather than 10 PaStandard
Electrical
Loop supply24 VDC output from the rear panelStandard
Current input terminalsTransmitter + and -, with COM, for a two-wire device under testStandard
CommunicationsRS-232 port on the rear panel; the protocol is not statedInformation required
ChargingDC 12 V input; the external supply runs from 220 VAC, with a charging indicator that changes from red to greenStandard
Battery lifeOne charge stated as 15 hours of operationStandard
Storage guidanceCharge every three months if the instrument is left unused, and stop charging when the indicator turns greenStandard
Environment
Relative humidity≤ 80%RHStandard
CaseDescribed as metal; no gradeInformation required
Operating temperature rangeInformation requiredInformation required
DisplayLCD with backlight; keys for on/off, zero, pressure, current, backlight and EnterStandard

Available models

Selection table
Model Configuration Key ranges Availability
Micropressure -95 kPa to 250 kPa, 10 Pa resolution Fitted with the positive and negative switching valve Compound range across atmospheric pressure
Low pressure 0-1.6 MPa and 0-2.5 MPa, 10 Pa resolution Single output port; no switching valve Pneumatic duties on compressed air and gas
Compound -95 kPa to 2.5 MPa, 10 Pa resolution Single output port; no switching valve Crosses zero across a wide span
Medium pressure 0-4 MPa, 10 Pa resolution Single output port; no switching valve The top of the pneumatic range
Hydraulic 0-16, 0-25, 0-40 and 0-60 MPa, 1 kPa resolution Requires pure water in the cup Higher pressures, where a compressible medium would store too much energy to be safe

Customization

  • A range selected from the pneumatic and hydraulic lists at the time of order
  • The water cup for hydraulic work, and the M20×1.5 internal thread adaptor for the device under test
  • A carrying case and the accessory kit for field work

Certification and compliance

Certification documents not yet supplied

Certifications are only published once a certificate copy can be produced, so this section is deliberately empty rather than populated with assumed approvals. Tell us which approvals your application requires and we will confirm what is available for this instrument.

Parameters still to be confirmed

The following are required for a complete specification but are not stated in the documentation supplied to us. They are listed rather than estimated:

  • How the 0.1%FS and 0.05%FS pressure accuracy entries relate: whether they are different range options or different accuracy tiers
  • Operating temperature range
  • Case material and the material of the pressure sensor diaphragm
  • RS-232 protocol and the commands or software supported
  • Whether a calibration certificate is supplied with the instrument, and to what accuracy it would be issued
  • Whether the accessories listed in the material — water cup, M20×1.5 adaptor, carrying case, test leads — are all supplied with the unit
  • Warranty period and the terms that apply
  • English-language manual in PDF form
  • Packaging dimensions and gross weight for freight calculation

Frequently asked questions

How accurate does a calibrator have to be for the instrument I am checking?

More accurate than the device under test by a margin that the quality system accepts, and it is the ratio between the two uncertainties that decides whether the exercise means anything. Where the calibrator is only slightly better than the device being checked, an apparent pass or fail at the tolerance limit cannot be relied on, because the two uncertainties overlap the tolerance itself. This instrument is stated at 0.05 grade with pressure accuracy given as 0.1%FS and 0.05%FS, so for a transmitter specified at 0.5%FS there is a comfortable ratio and for one specified at 0.1%FS there is not, and in that case the accuracy of the specific range ordered has to be established first.

Why are there two figures for pressure accuracy?

Because the material states both a grade and a pair of error limits. A grade is a class defined by a verification regulation and the instrument in the material was verified to JJG875-2005 at 0.05 grade; 0.1%FS and 0.05%FS are error limits stated against full scale. Whether the 0.1%FS figure describes a different range option of the same instrument or a different accuracy tier has not been established, so both are published as they appear and the figure for a given range is confirmed when the range is quoted. The two are not averaged into one number.

Do I need the hydraulic ranges?

Only if the device under test is a high-pressure instrument. The pneumatic ranges reach 4 MPa and use air, which is clean, easy to vent and appropriate at those pressures. Above that the instrument uses water, because compressing a gas to those pressures stores a great deal of energy and a leak or a burst joint releases it suddenly. The hydraulic ranges need pure water in the cup and give 1 kPa resolution rather than 10 Pa, so a hydraulic instrument is not the finer tool for a low-pressure job and a pneumatic one should not be taken to high pressure.

How does checking a two-wire transmitter work?

The calibrator supplies 24 VDC to the transmitter and reads the current the transmitter returns, while the hand pump applies the pressure. Both figures appear on the display at once, so the pressure can be brought to a verification point with the trim adjustment and the corresponding current read directly, either in milliamps or as a percentage of span. The transmitter connects to the + and - terminals with the common, which is the standard two-wire arrangement; a four-wire device would be connected differently and that should be stated when enquiring.

What has to be stated for a quotation?

The range required, and whether pneumatic or hydraulic operation is needed, since the two do not cover the same pressures. Then the pressure connection on the device under test, the electrical arrangement of the device if its current is to be read, whether a calibration certificate is required and to what accuracy, and the working conditions if they are outside the published humidity limit. If the instrument is to be verified against a specific regulation, say which one, because verification is against a named regulation rather than against an accuracy figure in general.

Related products

Other models in the same range

Rectangular pressure switch with a transparent scale window showing RANGE and DIFF marks, two adjustment screws, a metal threaded pressure port and a circular push-in fitting on the side

PK503 (3 models) · Pressure Switches

Mechanical Pressure Switch

Mechanical pressure switches with a separate set point and differential screw, SPDT contacts and automatic reset, covering vacuum down to -0.05 MPa and positive pressure to 1.0 MPa in three range versions.

Ranges
PK503 -0.05 to 0.3 MPa; PK506 -0.05 to 0.6 MPa; PK510 0.1 to 1.0 MPa
Adjustable differential
0.035 to 0.15 MPa; 0.06 to 0.4 MPa; 0.1 to 0.3 MPa respectively
Contact form
SPDT, single pole double throw, terminals 1-3-5
Reset
Automatic
Three stainless steel pressure transmitters side by side, one with a plug connector, one with a plug and tubular body, and one with a circular connector and cable gland

MIK-P300 · Pressure Transmitters

Configurable Pressure Transmitter

Diffusion silicon pressure transmitters built in a family of housings, from a plain plug version to sanitary, high-temperature, explosion-proof and 4G wireless forms, with 4-20 mA, voltage or RS-485 Modbus output.

Pressure ranges
-100 kPa to 60 MPa across the series
Pressure types
Gauge, absolute and sealed gauge
Accuracy
0.2, 0.25 or 0.5 grade, by range and configuration
Output
4-20 mA two-wire; 0-5 V, 1-5 V or 0-10 V three-wire; RS-485 with Modbus
Black cased circular pressure gauge with a white dial graduated to 1.6 MPa, a red tipped pointer and a brass threaded connection below the case

Y-60 (2 models) · Pressure Gauges

Bourdon Tube Pressure Gauge

Bourdon tube pressure gauges in 60 mm and 100 mm dial sizes with brass connections, covering vacuum to 40 MPa on the 60 mm dial and offered across a wide range list on the 100 mm dial, in iron and stainless steel cases.

Dial sizes
60 mm (Y-60) and 100 mm (Y-100); a 150 mm size is named without a parameter table
Accuracy class
2.5 class on the 60 mm dial; 1.6 class on the 100 mm dial
Range, 60 mm dial
0-0.1 MPa up to 0-40 MPa in fourteen steps, plus -0.1-0 MPa vacuum
Range, 100 mm dial
0-0.1 MPa up to 0-60 MPa listed for the series, with compound and vacuum forms

Request a quotation for the YPR-YBS-WY

Send the configuration you need and we will confirm availability, lead time and terms. Minimum order quantity is 1 pc.

Request for quotation

Request a quotation - YPR-YBS-WY

Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.

The more of this you can give us, the fewer exchanges are needed before we can quote.
No file chosen
Datasheet, drawing, BOM or photograph. One file, up to 10 MB (PDF, Office, image or ZIP).

By submitting this form you agree that we may contact you about this enquiry. We do not sell or share enquiry data. See our privacy policy.

Items held in stock are dispatched within 48 hours of order confirmation. Customized specifications are produced to order and typically ship within 2 to 10 days. Transit time then depends on the shipping method and destination.

Request a Quote WhatsApp