Pressure Measurement · Pressure Transmitters

Configurable Pressure Transmitter

Diffusion silicon pressure transmitters built in a family of housings, from a plain plug version to sanitary, high-temperature, explosion-proof and 4G wireless forms, with 4-20 mA, voltage or RS-485 Modbus output.

MIK-P300 ·

Key specifications

Pressure ranges
-100 kPa to 60 MPa across the series
Pressure types
Gauge, absolute and sealed gauge
Accuracy
0.2, 0.25 or 0.5 grade, by range and configuration
Output
4-20 mA two-wire; 0-5 V, 1-5 V or 0-10 V three-wire; RS-485 with Modbus
Supply
10-32 V on the current output; 5-32 V on RS-485, depending on the display fitted
Response time
T90 ≤ 10 ms on current and voltage output; T90 ≤ 100 ms on RS-485
Stability
±0.2%FS per year
Overpressure
150%FS from 0.035 to 10 MPa; 125%FS from 10 to 60 MPa
Process connection
M20×1.5 as standard; M14×1.5, G1/4, G1/2 and others to order
Sealing
IP65

A pressure transmitter turns the pressure at a tapping point into a signal a control system can read. The instrument on this page uses a diffusion silicon sensing element and covers gauge, absolute and sealed gauge references, with a span from -100 kPa up to 60 MPa across the series. Output is 4-20 mA two-wire as standard, with 0-5 V, 1-5 V, 0-10 V and RS-485 Modbus available by configuration.

What distinguishes this series is not the element but the number of constructions built around it. The same measurement module is offered in a plain plug housing, a short housing for a tight installation, a finned housing for hot media, a housing with a four-digit display, a GX12 circular connector version, a flush-diaphragm sanitary version with a clamp connection, a die-cast aluminium housing, a flanged version, and forms with a 4G radio or a flameproof enclosure. That range exists because the element is small and the electronics are a circuit board; once those two are fixed, the housing is what decides where the instrument can be used.

How the housing decides where the transmitter can be used

The measuring element itself is a silicon diaphragm with a diffused resistor network, isolated from the process by a thin diaphragm and a fill fluid in industrial constructions. The medium therefore meets the wetted metal rather than the silicon, and the element stays at a temperature the compensation can handle. Everything the housing does follows from protecting that arrangement without distorting what it reads.

A finned housing moves heat away from the electronics, which is why a high-temperature construction exists at all: the limit is usually the circuit and the fill fluid rather than the diaphragm, and the fins buy back the difference. A flush diaphragm removes the dead volume in front of the element, so a medium that would stagnate or hold residue in a threaded port does not have anywhere to sit. A flameproof enclosure contains an internal fault rather than preventing it, which is why it changes what the instrument is permitted to be installed next to, and nothing about what it measures. A radio version removes the cable, which changes the installation cost far more than it changes the measurement.

Two figures move with the span rather than with the housing, and they are worth reading together. Temperature drift within the compensated range is 2%FS on spans from 10 to 60 kPa and 1.5%FS above that, and the compensated range itself is 0 to 60°C, 0 to 70°C or -10 to 70°C depending on the span band. A narrow span on a cold outdoor installation is therefore a different proposition from the same instrument indoors.

How to select the right transmitter

Settle the pressure type first. A gauge transmitter reads against local atmosphere and suits a pump discharge, a compressed air line or a vented tank. An absolute transmitter reads against a sealed vacuum and is the right choice where the barometric term must not appear in the reading. A sealed gauge transmitter holds a fixed internal reference and is used where a vented reference would fill with the medium. A compound range crossing zero is a fourth case again, and it is not interchangeable with a sealed gauge instrument of the same numeric span.

Then settle the span against the working pressure rather than the peak. The accuracy grade applies to the full scale of the span selected, so a range several times the normal working pressure spends its life reading a small fraction of full scale and reports less than it could. The published overpressure figure - 150%FS up to 10 MPa and 125%FS above it - covers short spikes such as a pump start or a line test, not a sustained overrange.

Then settle the environment, because that is what selects the housing: media temperature picks between the standard and finned constructions, the cleanliness requirement picks the flush diaphragm, the area classification picks the enclosure, and the distance to the control system picks between a loop and a radio. Media compatibility is the remaining item, and the supplied material does not state the diaphragm or port material, so an aggressive medium has to be raised with the enquiry rather than assumed.

Wiring, supply and load resistance

The supply range and the loop resistance are published together because one constrains the other. On the current output, the load a two-wire loop can drive is RL ≤ (U-10 V)/0.02 A without a local display and RL ≤ (U-14 V)/0.02 A with one, where U is the supply voltage. The difference between the two expressions is the voltage the display needs, and using the wrong one is how a loop that looked comfortable on paper reads low at the top of its range. On the voltage outputs the constraint is a minimum load of 5 kΩ rather than a maximum.

The supply itself changes with the output and the display: 10-32 V for 4-20 mA, 8-32 V for 0-5 V or 1-5 V, 12-32 V for 0-10 V, and on RS-485 either 8-32 V, 7-32 V or 5-28 V depending on whether a display is fitted and whether it is LCD or LED. The pin functions are not the same across the output forms, so the wiring is read from the form ordered rather than from the series in general.

Measurement limitations and selection considerations

A transmitter selected with far more span than the duty needs is the most common way to make a good instrument read poorly. The grade applies to full scale, so the error at the working point grows in proportion to how much of the span is unused.

Narrow spans on cold installations deserve a second look, because the compensated range narrows as the span narrows and the drift figure rises. Where the process sits at the bottom of a narrow span outdoors, a different sensing technology or a wider span may serve better than a tighter grade on the same instrument.

A transmitter is also the wrong instrument where the question is not continuous. If the requirement is a contact that changes state at a set point, a pressure switch does that without a loop; if the requirement is a local indication and nothing else, a gauge does it without a supply. Where the medium is aggressive, the answer is usually a separating diaphragm ahead of the instrument rather than a more exotic wetted metal, and where the medium pulses hard, the damping structure in the port helps but does not replace a proper snubber.

Configuration and ordering

The supplied material does not give a model code breakdown for the series, so a configuration is stated in words: pressure type, range, output form, supply, process connection, electrical connection, housing and lead length. That is also what a quotation needs, and it is the order in which the choices constrain each other - the output form fixes the supply range, the supply range fixes the load that can be driven, and the housing fixes the media temperature that applies.

Features

  • A single series covering twelve housing constructions, so a site with a sanitary point, a hot point and a remote point can be fitted from one range instead of three
  • Gauge, absolute and sealed gauge references available, which means the same housing can serve a vented pipe and a sealed vessel without a second product line
  • Supply and load resistance published against each output form, so the loop can be checked against the supply on hand before the order is placed
  • Temperature drift and compensated range stated separately for three span bands, rather than as one figure applied to the whole series
  • Stability of ±0.2%FS per year, which is the figure a recalibration interval is normally set from
  • Silicone gel potting and an O-ring sealed housing, for damp plant rooms and washdown areas within the IP65 rating
  • A 3 mm pressure port with a damping structure, to limit the effect of a pressure spike on the reading
  • 48 hours of high-temperature ageing before dispatch, stated by the supplier as part of the dispatch routine

Technical specifications

Every value below is taken from source documentation. Where a parameter is not stated in the available material it is marked as information required rather than estimated.

Measurement
Measured variablesGauge, absolute and sealed gaugeStandard
Range span-100 kPa to 60 MPa over the seriesStandard
Accuracy grades0.2, 0.25 and 0.5 grade; the promoted comparison figure on the listing is not a grade — see the note belowInformation required
Long-term stability±0.2%FS per yearStandard
Temperature drift within the compensated range2%FS on spans from 10 to 60 kPa; 1.5%FS on spans above 60 kPa up to 60 MPaStandard
Compensated temperature range0 to 60°C from 10 to 25 kPa; 0 to 70°C from 25 to 60 kPa; -10 to 70°C above 60 kPaStandard
Response timeT90 ≤ 10 ms on current and voltage output; T90 ≤ 100 ms on RS-485Standard
Reference standard behind the accuracy figureInformation requiredInformation required
Output and supply
4-20 mATwo-wire; pin 1 to supply positive, pin 2 to the receiving instrumentStandard
0-5 V, 1-5 V, 0-10 VThree-wire; pin 1 to supply positive, pin 2 common, pin 3 signalOptional
RS-485Modbus protocol, two-wire; the terminal definition is not given in the supplied materialInformation required
Supply voltage10-32 V on 4-20 mA; 8-32 V on 0-5 V or 1-5 V; 12-32 V on 0-10 V; 8-32 V on RS-485 without display, 7-32 V with a 4-digit LCD and 5-28 V with a 4-digit LED displayStandard
Load resistanceRL ≤ (U-10 V)/0.02 A without a display; RL ≤ (U-14 V)/0.02 A with a display; ≥ 5 kΩ on the voltage formsStandard
Power consumption at 24 VDC≤ 0.6 W current output; ≤ 0.05 W voltage output; ≤ 0.2 W RS-485Standard
Insulation20 MΩ at 250 VDC; 500 VAC at 50 HzStandard
Electrical connectionFlying leads, GX12 circular connector or DIN43650-A plug, by configurationStandard
Standard lead length2 mStandard
Process conditions
Media temperature-20 to 85°C on the standard constructionStandard
Media temperature, high-temperature constructionStated as 300°C for that housing, which is a housing marking rather than the series figure — confirm the media temperature for the actual dutyInformation required
Operating temperature-20 to 85°CStandard
Storage temperature-40 to 85°CStandard
SealingIP65Standard
Overpressure150%FS from 0.035 to 10 MPa; 125%FS from 10 to 60 MPaStandard
Wetted materialNot stated beyond the 3 mm pressure port and the O-ring sealing of the housingInformation required
Medium compatibilityStated for general liquid, gas and steam duties; a medium that attacks the wetted parts is not covered by the general statementStandard
Process connection
Standard threadM20×1.5Standard
Further threadsM14×1.5, G1/4 and G1/2 from the sales sheet; others to orderStandard
Flange and clamp versionsSingle and double flange, and a flush diaphragm with a clamp connection on the sanitary housingOptional
Thread length and port diameterMarked L and D on the outline drawings without a value table; the figures move with the thread orderedInformation required
Dimensions
Body diameterΦ26.5 mm on the standard housing; Φ26.5 mm with a Φ10.7 mm bore on the high-temperature housingStandard
Across flats27 mmStandard
Thread length12 mm on the standard housingStandard
Overall height, standard housing81.5 mm plug form without display; 96.5 mm plug form with RS-485; 94 mm display form without RS-485; 121 mm display form with RS-485Standard
Overall height, high-temperature housing120.5 mm, 135.5 mm, 146 mm or 161 mm across the four formsStandard
2026-11 supply batch
ScopeAdditional forms supplied in November 2026 for this product type. Figures below are from that batch; where they differ from the rows above, both are recorded rather than merged.Standard
Ranges in this batch0-0.6 MPa, 0-1 MPa and 0-1.6 MPa as the common spansStandard
Accuracy0.2 class and 0.5 class, with plus or minus 0.15 % and 0.03 % figures on some listingsStandard
Output4-20 mA, RS-485/Modbus, HART and 0-10 VStandard
Supply24 V DC as standard, with 12 V DC and battery-powered versionsStandard
Process connectionM20 x 1.5, G1/2 and NPT1/2Standard
Wetted material316L stainless, 304 stainless and PTFE diaphragmStandard
Medium temperature10 to 70 C on the general form, with high-temperature versions to 350 CStandard
Ingress protectionIP65, with IP67 versionsStandard

Available models

Selection table
Model Configuration Key ranges Availability
Standard housing DIN43650-A plug, no display 4-20 mA, 24 VDC, M20×1.5 Ambient-temperature liquid, gas or oil on general plant duties
Compact housing Short body As configured Where the installation depth at the tapping point is limited
High-temperature housing Five radiator fins, stated for media to 300°C As configured Hot media; confirm the media temperature for the duty against the housing marking
Digital display housing 4-digit LCD or 4-digit 8-segment LED 4-20 mA or RS-485 Where a local reading is wanted at the tapping point
Circular connector housing GX12 connector As configured Machinery where the cable is supplied and fitted separately
Sanitary housing Flush diaphragm with a clamp connection As configured Pharmaceutical, medical and brewing duties
2088 housing Die-cast aluminium As configured High-temperature water and oil duties
Single-crystal silicon housing Single-crystal silicon element in place of the diffusion silicon chip As configured A different sensing element from the rest of the series
Flanged housing Single or double flange As configured Flange mounting at the tapping point
Wireless housing 4G remote transmission As configured Several pressure points read remotely
Explosion-proof housing Flameproof enclosure As configured The supplied material gives no approval mark, certificate number or hazardous-area classification for this housing

Customization

  • Process connection changed to M14×1.5, G1/4, G1/2 or another thread
  • Output form changed between 4-20 mA, 0-5 V, 1-5 V, 0-10 V and RS-485 Modbus
  • Local display added or omitted, which also changes the supply voltage range that applies
  • Housing changed within the family, including sanitary, high-temperature, flanged and explosion-proof constructions
  • Lead length set to the installation rather than the standard 2 m
  • Ranges outside the general span, and compound ranges crossing zero

Certification and compliance

Certification documents not yet supplied

Certifications are only published once a certificate copy can be produced, so this section is deliberately empty rather than populated with assumed approvals. Tell us which approvals your application requires and we will confirm what is available for this instrument.

Parameters still to be confirmed

The following are required for a complete specification but are not stated in the documentation supplied to us. They are listed rather than estimated:

  • Official model designation and whether the MIK prefix is a model designator or a brand abbreviation
  • Accuracy grade that applies to a given range, and the reference standard behind the accuracy figure
  • Media temperature suitable for the high-temperature housing in a specific duty, as distinct from the 300°C housing marking
  • Wetted material of the diaphragm, the port and the flange faces
  • RS-485 terminal definition and pinout
  • Thread length L and port diameter D value tables
  • Approval mark, certificate number and hazardous-area classification for the explosion-proof housing
  • Whether the sanitation of the flush diaphragm construction is certified to any standard
  • Specifications for the 4G wireless construction, including the network and the data path
  • Certification list and availability of certificate copies
  • Warranty period and the terms that apply
  • English-language datasheet, wiring diagram and outline drawings in PDF form
  • Packaging dimensions and gross weight for freight calculation
  • Whether a calibration certificate can be supplied, and to what accuracy

Frequently asked questions

How do I choose between the housing constructions?

Start from the environment and the medium rather than from the electronics, because the housing is what decides where the instrument can physically be used and the electronics are available in most of them. If the medium is a pharmaceutical, medical or brewing product, the sanitary housing with a flush diaphragm and a clamp is the only one of the family that does not leave a crevice at the process face. If the medium is hot, the high-temperature housing with its fins is the construction intended for it, and the media temperature for that duty should be confirmed rather than read off the series table. If the tapping point is in a hazardous area, the flameproof housing is the one to ask about, and approval documentation has to be requested with the enquiry. Everything else is settled by what connector the cable and the installation call for.

Which output should I order?

Two-wire 4-20 mA is the default and suits most installations, because the same two conductors carry the supply and the signal and a small voltage drop along the cable does not change the reading. A three-wire voltage output suits a short run into a controller that takes a voltage input. RS-485 suits a transmitter that has to be read digitally alongside others on the same bus, and the Modbus protocol is stated for it. The pin functions differ between the three forms and the supply range differs as well, so the output is settled before the wiring is planned rather than afterwards.

Why does the supply voltage range change with the display?

Because the display and its driver draw from the same loop supply, so more voltage has to be available at the instrument before the output stage still has enough headroom. On RS-485 the published range is 8-32 V without a display, 7-32 V with a four-digit LCD and 5-28 V with a four-digit LED display. On the current output the supply range changes the load resistance that can be driven: RL ≤ (U-10 V)/0.02 A without a display and RL ≤ (U-14 V)/0.02 A with one. Checking the supply against the loop resistance before ordering is what avoids an instrument that reads correctly on the bench and not in the panel.

What has to be stated for a quotation?

The pressure type - gauge, absolute or sealed gauge - and the range, since a compound range and a sealed gauge range of the same span are different instruments. Then the output form, the supply available at the point, the process connection thread and the electrical connection. If the medium is not a general liquid, gas or steam duty, say what it is. If the medium or the ambient is hotter than the standard figures, say so, because the high-temperature construction is a separate housing. For a hazardous area, state the classification required, because no approval for that housing is documented in the material supplied to us.

Is the accuracy figure 0.2 or 0.5?

The parameter panel lists 0.2, 0.25 and 0.5 grade, and which of them applies depends on the range and the configuration ordered. A separate promotional panel on the same listing contrasts a 0.2% figure with a 0.5% figure and attributes them to different chips; that panel is a sales comparison rather than a grade list, and it is not used here. The grade that applies to a specific range is confirmed when the range is quoted.

Related products

Other models in the same range

Stainless steel pressure transmitter with a plug connector on top, a hex body and a threaded pressure port

TFD-801 · Pressure Sensors

Diffusion Silicon Pressure Transmitter

Diffusion silicon pressure transmitters with a 304 stainless steel body, IP65 sealing and ranges from -100 kPa to 100 MPa, in two-wire 4-20 mA and three-wire voltage forms.

Pressure ranges
-100 kPa to 100 MPa across the series
Pressure types
Gauge, absolute and sealed gauge
Accuracy
0.2%FS on the stocked ranges; a 0.5% grade is listed for the series
Output
4-20 mA two-wire as standard; 0-5 V, 0-10 V or RS-485 to order
Rectangular pressure switch with a transparent scale window showing RANGE and DIFF marks, two adjustment screws, a metal threaded pressure port and a circular push-in fitting on the side

PK503 (3 models) · Pressure Switches

Mechanical Pressure Switch

Mechanical pressure switches with a separate set point and differential screw, SPDT contacts and automatic reset, covering vacuum down to -0.05 MPa and positive pressure to 1.0 MPa in three range versions.

Ranges
PK503 -0.05 to 0.3 MPa; PK506 -0.05 to 0.6 MPa; PK510 0.1 to 1.0 MPa
Adjustable differential
0.035 to 0.15 MPa; 0.06 to 0.4 MPa; 0.1 to 0.3 MPa respectively
Contact form
SPDT, single pole double throw, terminals 1-3-5
Reset
Automatic
Black cased circular pressure gauge with a white dial graduated to 1.6 MPa, a red tipped pointer and a brass threaded connection below the case

Y-60 (2 models) · Pressure Gauges

Bourdon Tube Pressure Gauge

Bourdon tube pressure gauges in 60 mm and 100 mm dial sizes with brass connections, covering vacuum to 40 MPa on the 60 mm dial and offered across a wide range list on the 100 mm dial, in iron and stainless steel cases.

Dial sizes
60 mm (Y-60) and 100 mm (Y-100); a 150 mm size is named without a parameter table
Accuracy class
2.5 class on the 60 mm dial; 1.6 class on the 100 mm dial
Range, 60 mm dial
0-0.1 MPa up to 0-40 MPa in fourteen steps, plus -0.1-0 MPa vacuum
Range, 100 mm dial
0-0.1 MPa up to 0-60 MPa listed for the series, with compound and vacuum forms

Request a quotation for the MIK-P300

Send the configuration you need and we will confirm availability, lead time and terms. Minimum order quantity is 1 pc.

Request for quotation

Request a quotation - MIK-P300

Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.

The more of this you can give us, the fewer exchanges are needed before we can quote.
No file chosen
Datasheet, drawing, BOM or photograph. One file, up to 10 MB (PDF, Office, image or ZIP).

By submitting this form you agree that we may contact you about this enquiry. We do not sell or share enquiry data. See our privacy policy.

Items held in stock are dispatched within 48 hours of order confirmation. Customized specifications are produced to order and typically ship within 2 to 10 days. Transit time then depends on the shipping method and destination.

Request a Quote WhatsApp