Diffusion silicon pressure transmitters with a 304 stainless steel body, IP65 sealing and ranges from -100 kPa to 100 MPa, in two-wire 4-20 mA and three-wire voltage forms.
TFD-801 ·
Key specifications
- Pressure ranges
- -100 kPa to 100 MPa across the series
- Pressure types
- Gauge, absolute and sealed gauge
- Accuracy
- 0.2%FS on the stocked ranges; a 0.5% grade is listed for the series
- Output
- 4-20 mA two-wire as standard; 0-5 V, 0-10 V or RS-485 to order
- Supply
- 24 VDC; wide-range and low-voltage options listed in the code
- Stability
- ±0.1%FS per year
- Temperature drift
- ±0.03%FS/°C
- Response rate
- 10 to 1200 Hz
- Body and sealing
- 304 stainless steel, IP65
- Process connection
- M20×1.5 as standard; other threads to order
A pressure transmitter converts a line pressure into a signal a control system can read. The instrument on this page uses a diffusion silicon sensing element inside a 304 stainless steel body, which means the pressure acts on the element directly and the output is derived from the element rather than from the movement of a mechanism.
The series spans -100 kPa to 100 MPa and covers gauge, absolute and sealed gauge references. Seventeen ranges are held as stocked items from 0-5 kPa to 0-2.5 MPa, all with a 4-20 mA two-wire output, a 24 VDC supply, an M20×1.5 process connection and a 1 m cable. The wider series runs from 0-1 kPa up to 0-60 MPa and includes compound ranges that cross zero into vacuum.
The output is 4-20 mA as standard, with 0-5 V, 0-10 V and RS-485 available to order. Sealing is IP65, the stated accuracy on the stocked ranges is 0.2%FS with a stability of ±0.1%FS per year, and the media temperature range is -20 to +80°C as standard or to +150°C in the high-temperature construction.
How a diffusion silicon pressure transmitter works
The sensing element is a silicon diaphragm with a diffused resistor network on its surface. Pressure on one side of the diaphragm deflects it, the resistors change value with the strain, and a bridge circuit converts that change into a voltage. The element is a solid-state device with no lever, no pivot and no linkage, which is why a transmitter of this kind holds its calibration better than a mechanical gauge under vibration and why it can be made small enough to fit a machine port.
The diaphragm is separated from the process by a thin isolation diaphragm and a fill fluid in most industrial constructions, so the medium touches 304 stainless steel rather than the silicon. That decision is what allows the same element to be used on water, oil and gas. It also sets the limit: a medium that attacks 304 stainless steel attacks the isolation diaphragm just as it would any other part of the wetted assembly.
The output stage then converts the bridge voltage into the standard signal. In a two-wire 4-20 mA arrangement the transmitter draws its own supply from the same loop it modulates, so the current flowing in the loop is the measurement and the receiving instrument reads it directly. That is why a two-wire loop is unaffected by a small voltage drop along the cable, and why the same two conductors serve both purposes.
How to select the right transmitter
Choose the measurement range first, and choose it from the normal working pressure rather than from a peak figure. The stated accuracy applies to the full scale of the range selected, so a range several times higher than the working pressure makes every reading less precise than it needs to be. The 1.5 times overpressure figure covers short-duration spikes rather than a sustained overrange.
Then decide the pressure reference. A gauge transmitter reads relative to atmosphere and is the usual choice for a pump discharge or a compressed air line. An absolute transmitter reads relative to vacuum and is used where barometric changes matter. A sealed gauge transmitter reads relative to a sealed reference and suits a case where a vented reference would be filled with the medium.
Then settle the output and the connection. Two-wire 4-20 mA is the default and the simplest to wire. A voltage output suits a short run to a controller that takes a voltage input, and RS-485 suits a transmitter read digitally alongside others. The process connection is usually fixed by the port already on the machine, and the options here run from M8×1 to DN100 flanges with custom threads available.
Finally confirm the medium and the temperature. Water, oil and general gases suit the standard construction. A medium above 80°C needs the high-temperature version, and a medium that attacks 304 stainless steel needs a different wetted material, which is a case to raise rather than to assume.
Limitations and points to confirm
A transmitter measures pressure at one point. It does not measure flow by itself, and a pressure reading used to infer flow depends on the geometry between the tapping and the reference point, so the same instrument gives different results on a different installation. Where a flow figure has to be calculated from a differential pressure, that is a separate measurement arrangement.
The 304 stainless steel body is not suitable for every medium. Chloride-bearing water, some acids and some process chemicals attack it, and the usual sign is pitting at the isolation diaphragm rather than at the body. Compatibility is a question to settle before the order for any medium outside water, oil and general gas.
Two figures in the supplied material need confirmation and are published as open. The accuracy appears as both 0.2% and 0.5%, with every stocked item marked at 0.2%FS and the 0.5% figure described as a series option. And the reference standard behind the accuracy figure is not named, so if a particular standard has to be cited, that is a case to raise rather than to read from this page.
Several other values a specification often calls for are absent from the material and appear here as information required: the operating temperature range of the electronics as distinct from the media range, the calibration documentation, and the certification list. The pin functions also differ between the output forms, so the wiring is taken from the form ordered rather than from a single diagram.
Features
- A diffusion silicon sensing element, so the pressure is measured by the element itself rather than through a mechanical linkage
- A 304 stainless steel body that suits water, oil and gas without a separate wetted-parts decision on most jobs
- A 3 mm pressure port with a damping structure, which limits the effect of a pressure spike on the reading
- IP65 sealing, for machine mounting rather than cabinet mounting
- Ranges spanning -100 kPa to 100 MPa from one series, so a machine with several pressure points can be fitted from one family
- Output forms covering two-wire current, three-wire voltage and RS-485, for connection to a display, a PLC, a drive or a data acquisition module
- Accuracy of 0.2%FS and a stability figure of ±0.1%FS per year, which is what a yearly calibration interval is normally based on
- Process connections from M8×1 up to DN100 flanges, plus custom threads, so an existing port can usually be matched
Technical specifications
Every value below is taken from source documentation. Where a parameter is not stated in the available material it is marked as information required rather than estimated.
| Range span | -100 kPa to 100 MPa over the seriesStandard |
|---|---|
| Pressure types | Gauge, absolute and sealed gaugeStandard |
| Accuracy, stocked ranges | 0.2%FSStandard |
| Accuracy, series options | 0.2% and 0.5%; the two figures appear in different places in the supplied materialInformation required |
| Stability | ±0.1%FS per yearStandard |
| Temperature drift | ±0.03%FS/°CStandard |
| Response rate | 10 to 1200 HzStandard |
| Overpressure | 1.5 times the rated pressure, stated as short-durationStandard |
| Reference standard behind the accuracy figure | Information requiredInformation required |
| 4-20 mA | Two-wire; pin 1 to supply positive, pin 2 to the receiving instrumentStandard |
|---|---|
| 0-5 V and 0-10 V | Three-wire; pin 1 to supply positive, pin 2 common, pin 3 signalOptional |
| RS-485 | Four-wire; pins 1 and 2 to supply, pins 3 and 4 to A and BOptional |
| Supply voltage | 24 VDC nominalStandard |
| Supply options in the code | 8 to 30 V, 5 V, and 3.3 to 3.6 VOptional |
| Pin numbering | The same pin number carries a different function on different output forms, so the wiring is read from the form orderedStandard |
| Compatible media | Water, oil, gas and general liquidsStandard |
|---|---|
| Media temperature, standard | -20 to +80°CStandard |
| Media temperature, high-temperature version | -40 to +150°COptional |
| Operating temperature range of the electronics | Information requiredInformation required |
| Sealing | IP65Standard |
| Body material | 304 stainless steelStandard |
| Sensing element | Diffusion silicon chipStandard |
| Pressure port | 3 mm diameter, with a damping structureStandard |
| Electrical connection | Plug, sealed cable entry or circular connector, by codeStandard |
| Cable length | 1 m as standardStandard |
| 0 to 5, 10, 20, 30, 50, 70, 100 kPa | 4-20 mA, 24 VDC, M20×1.5 thread, 1 m cable, 0.2%FSStandard |
|---|---|
| 0 to 160, 200, 250, 300, 400, 500, 600 kPa | 4-20 mA, 24 VDC, M20×1.5 thread, 1 m cable, 0.2%FSStandard |
| 0 to 1, 1.6 and 2.5 MPa | 4-20 mA, 24 VDC, M20×1.5 thread, 1 m cable, 0.2%FSStandard |
| Other ranges in the series | Codes cover 0-1 kPa up to 0-60 MPa, plus compound ranges from -100-0 kPa to -10-10 kPaOptional |
| Standard thread | M20×1.5Standard |
|---|---|
| Metric threads | M8×1, M10×1, M12×1, M12×1.25, M12×1.5, M14×1.5, M16×1.5, M18×1.5Optional |
| Parallel and tapered threads | G1/8 to G1, R1/8 and R3/8, ZG1/8 to ZG1/2Optional |
| NPT threads | NPT1/4, NPT1/2Optional |
| Clamp and flange connections | Clamp 25 and 50.5 mm; DN15 to DN100Optional |
| Flange standard | KF16Optional |
| Custom connection | Available to orderOptional |
| Scope | Additional forms supplied in November 2026 for this product type. Figures below are from that batch; where they differ from the rows above, both are recorded rather than merged.Standard |
|---|---|
| Accuracy | 0.2 class and 0.5 classStandard |
| Output | 4-20 mA and RS-485/ModbusStandard |
| Supply | 24 V DCStandard |
| Operating temperature | -40 to 85 C on the electronicsStandard |
| Process connection | M20 x 1.5 and G1/2Standard |
| Wetted material | 316L stainless and 304 stainlessStandard |
Available models
| Model | Configuration | Key ranges | Availability |
|---|---|---|---|
| Low pressure | 0-5 to 0-70 kPa | 4-20 mA, 24 VDC, M20×1.5, 0.2%FS | Stocked ranges for air and low-pressure water duties |
| Medium pressure | 0-100 to 0-600 kPa | 4-20 mA, 24 VDC, M20×1.5, 0.2%FS | Stocked ranges covering water supply and light hydraulic duties |
| High pressure | 0-1 to 0-2.5 MPa | 4-20 mA, 24 VDC, M20×1.5, 0.2%FS | Stocked ranges for hydraulic and compressed air systems |
| Compound | -100-0 kPa and -100-100 kPa | Vacuum and pressure from one instrument | Codes also cover -50-50, -30-30 and -10-10 kPa |
| Series range options | Up to 0-60 MPa | With output, supply and connection by code | Supplied to order rather than from stock |
| High-temperature version | Media to +150°C | Standard media range is -20 to +80°C | Stated as a separate version of the same series |
Customization
- Process connection thread to a customer specification, from M8×1 up to DN100
- Output form changed from 4-20 mA to 0-5 V, 0-10 V or RS-485
- Supply voltage options of 8-30 V, 5 V or 3.3-3.6 V in place of 24 V nominal
- Electrical connection as plug, sealed cable entry or circular connector
- High-temperature construction for media up to +150°C
- Ranges outside the stocked list, from 0-1 kPa to 0-60 MPa
Certification and compliance
Certification documents not yet supplied
Certifications are only published once a certificate copy can be produced, so this section is deliberately empty rather than populated with assumed approvals. Tell us which approvals your application requires and we will confirm what is available for this instrument.
Parameters still to be confirmed
The following are required for a complete specification but are not stated in the documentation supplied to us. They are listed rather than estimated:
- Which accuracy grade applies to the series as opposed to the stocked ranges (0.2% and 0.5% both appear in the supplied material)
- Reference standard behind the accuracy figure
- Operating temperature range of the electronics, as distinct from the media temperature range
- Whether the thread codes are exclusive to this series, and the difference between the two entries both marked NPT1/2 internal
- Flange and clamp connection dimensions for the DN and KF16 options
- Certification list and availability of certificate copies
- Warranty period and the terms that apply
- English-language datasheet, wiring diagram and dimension drawings in PDF form
- Packaging dimensions and gross weight for freight calculation
- Whether a calibration certificate can be supplied, and to what accuracy
Frequently asked questions
How is a range chosen for a pump or a hydraulic line?
Pick the range from the pressure the line reaches in normal operation, not from the pressure it might reach in a fault. A transmitter spends its life at a fraction of its full scale on most duties, and the accuracy figure applies to that full scale, so a range far above the working pressure makes every reading less precise than it needs to be. A range somewhat above the highest normal working pressure is the usual compromise, and the 1.5 times overpressure figure covers the short spikes rather than a sustained overrange.
Which output form should be used?
Two-wire 4-20 mA is the default and suits most installations, because the same two conductors carry the supply and the signal, and the current loop is unaffected by a small voltage drop along the cable. Three-wire 0-5 V or 0-10 V suits short runs to a controller that takes a voltage input. RS-485 suits a transmitter that has to be read digitally along with others on the same bus. The pin functions differ between the three forms, so the form has to be settled before the wiring is planned rather than after.
Are the stocked ranges the same as the full series?
No. Seventeen ranges are held as stocked items, from 0-5 kPa to 0-2.5 MPa, all with a 4-20 mA output, a 24 VDC supply, an M20×1.5 thread and a 1 m cable at 0.2%FS. The series itself covers from 0-1 kPa to 0-60 MPa and includes compound ranges that cross zero, but those are supplied to order and the output, supply and connection are stated when they are ordered. If a job needs a range outside the stocked list, give the range and the connection and it is quoted as a configured item.
What has to be stated for a quotation?
The pressure range and whether it is gauge, absolute or sealed gauge; the pressure type matters because a compound range and a sealed gauge range of the same span are different instruments. Then the output form, the supply voltage, the process connection thread and the type of electrical connection. If the medium is not water, oil or a general gas, say what it is, and if the temperature is above 80°C say so, because the high-temperature version is a separate construction.
Is calibration documentation supplied?
The supplied material does not state that a calibration certificate comes with the transmitter, so this page does not claim one. If a certificate is required, say so when enquiring and we will confirm what can be provided and to what accuracy it would be issued. The stability figure of ±0.1%FS per year is the figure normally used to set a recalibration interval, and it describes the drift the instrument is stated to hold rather than a guarantee that a certificate accompanies every unit.
Request a quotation for the TFD-801
Send the configuration you need and we will confirm availability, lead time and terms. Minimum order quantity is 1 pc.
Request for quotation
Request a quotation - TFD-801
Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.