Process Analysis · pH Analyzers

Online pH/ORP Controller

Panel-mount pH and ORP controllers in three tiers, from a 4.3 inch display with two isolated current outputs and three alarm contacts down to a 96 x 96 mm case with one output, all reading pH to ±0.02 from a single glass or antimony electrode.

MIK-pH8.5 (3 models) ·

Key specifications

Tiers and displays
4.3 inch display on the flagship; 2.8 inch on the upgrade and economy tiers
Case size
151 x 144 x 118 mm flagship; 100 x 100 x 150 mm upgrade; 96 x 96 x 112 mm economy
pH range
-(2.00~16.00) pH on the flagship, with antimony electrode support; 0~14 pH on the upgrade and economy tiers
ORP range
±2000 mV on the flagship; -1000~+1000 mV on the economy tier; -1000~+1000 mV on the upgrade tier with ±2000 mV made to order
pH accuracy
±0.02 pH on all three tiers
ORP accuracy
±2 mV on the flagship; ±1 mV on the upgrade tier; not stated for the economy tier
Transmitter output
Isolated: two (0/4~20) mA channels at ±0.1 %FS on the flagship, meeting NAMUR NE43; one (4~20) mA channel at ±0.2 %F.S on the other two tiers
Output load
750 Ω maximum on every tier
Alarm contacts
Three SPST contacts, two alarm and one cleaning, at 250 VAC / 5 A on the flagship; two contacts at AC 250 V / 3 A on the other two tiers
Supply
AC (85~265) V or DC (21.6~26.4) V on the flagship; AC 220 V ±10 % on the economy tier; AC 220 V ±10 % or DC 24 V ±20 % on the upgrade tier

A pH analyzer is the instrument that turns acidity into something a control system can act on. It sits in the line or on the tank wall, reads continuously through a glass electrode, and holds a current output that a dosing pump, a controller or a recorder can follow. This range covers three panel-mount controllers built on the same electrode chemistry: a 4.3 inch flagship with two isolated outputs and a separate cleaning contact, and two 2.8 inch tiers that carry the same pH accuracy in smaller cases with a single output.

The tiers are easiest to read as a decision about the enclosure and the loop rather than about the measurement. All three read pH to ±0.02, and all three accept the same electrodes. What changes below the flagship is how many values the instrument can transmit at once, how many contacts it offers, and how much panel space it occupies.

What the controller measures

The primary measurement is pH. Behind it sits a second one, ORP, which the same instrument reads when an ORP electrode is fitted instead of a pH electrode. The two are not variants of each other: pH reports hydrogen ion activity on a logarithmic scale, while ORP reports the oxidising or reducing tendency of the solution in millivolts. A chlorinated stream can hold a steady pH while its ORP moves, so a disinfection loop and a neutralisation loop are measuring different things even when they sit on the same plant.

The flagship tier extends the pH span to -(2.0016.00) and supports an antimony electrode, which matters in strong acid and strong alkali where a glass membrane would not survive. The two smaller tiers work across 014 pH. On the ORP side the flagship reaches ±2000 mV, the economy tier is limited to -1000~+1000 mV, and the upgrade tier covers that span with ±2000 mV available to order.

How the measurement works

A glass measuring electrode and a reference electrode form an electrochemical cell, and the voltage across it depends on the hydrogen ion activity of the solution between them. The response is logarithmic, so a fixed change in millivolts corresponds to a fixed change in pH rather than a proportional one. The controller turns that voltage into a pH value using a calibration established against buffer solutions of known pH, and applies temperature compensation so that the electrode response is corrected to the temperature actually measured.

Three consequences follow, and all three matter more than the electronics. The first is that the measurement is a comparison, so the reference half of the cell is as important as the measuring half: a partly blocked or depleted reference junction appears as a reading that drifts or responds slowly, and no amount of recalibration cures it. The second is that the glass membrane is a consumable. It ages, it dehydrates if it is allowed to dry out, and it is attacked by hydrofluoric acid and by strong caustic at elevated temperature. The third is that temperature compensation corrects the electrode, not the process: where the pH of the process genuinely shifts with temperature, the compensation follows the electrode response and reports the true pH at that temperature, which is a different statement from the pH the specification was written against.

The compensation arrangement differs by tier. The flagship offers manual compensation plus automatic linear compensation, with dedicated acid, alkali and pure water compensation for the streams where a single linear model is not accurate enough. The upgrade tier accepts an NTC10K or Pt1000 sensor and the economy tier an NTC10K, both over a -10 to 130°C span. On every tier the usable span is set by whichever electrode is fitted, and the material supplies no temperature table for the electrode range.

Choosing between the three tiers

Start from the loop rather than the panel. If the installation has to transmit one value and switch one load, the smaller tiers do the whole job in a 96 x 96 mm or 100 x 100 mm cut-out. If pH and a second value both have to be transmitted, the flagship’s two isolated outputs are what make that possible without a second instrument, and its three contacts - two alarm and one cleaning - let a jet or brush cleaner be sequenced without borrowing an alarm relay.

Then check the supply, because the three tiers are not interchangeable there. The flagship accepts AC (85265) V or DC (21.626.4) V, so it will run on whatever a panel happens to provide. The economy tier takes AC 220 V ±10 % at 50 Hz or DC 24 V, and the upgrade tier AC 220 V ±10 % at 50 or 60 Hz or DC 24 V ±20 % with an input power of not less than 6 W. The material cautions expressly that these must not be mixed, and a panel supplied at a voltage outside the narrower ranges will need the flagship or a separate supply.

Then settle the panel itself. The three cases are different sizes and the front bezels are not interchangeable, so the cut-out has to be decided before the panel is made. Case material, gasket and ingress protection are not stated in the material, which matters on a washdown wall.

Selecting the electrode

The controller is only half the loop, and on most installations the electrode is what decides whether the measurement works. The material lists a partial range of matching electrodes - one plastic-body model for continuous online work and five glass models for general water quality - without a parameter table for any of them. Ranges, temperature limits, pressure limits and connection threads therefore have to be confirmed per model rather than read off this page.

Four questions decide the electrode, and they are worth answering before the instrument is ordered. What is in the medium: hydrofluoric acid, strong caustic, sulphides, oils, proteins and heavy solids each attack a different part of the cell. What temperature it runs at, including any cleaning or sterilisation cycle, since that drives both the electrode choice and how long it lasts. What the line pressure is and whether it varies, because the reference junction responds to pressure and a swinging or vacuum condition can pull the reference into the sample. And how the sensor will be reached: an electrode that cannot be withdrawn and cleaned without draining the line is an electrode that will drift.

The material’s own caution is worth repeating. The temperature compensation span is marked -10 to 130°C, but the usable measuring span belongs to the electrode, and no electrode temperature table is supplied. Where the process runs hot, that is a question for the quotation rather than an assumption from this page.

Outputs, alarms and the control loop

All three tiers provide an isolated current output, which keeps the instrument and the receiving device electrically separate and avoids a ground loop between them. The flagship has two channels, assignable across the measuring range, at ±0.1 %FS and meeting NAMUR NE43. The upgrade and economy tiers have one channel at ±0.2 %F.S. Every tier is rated for a maximum load of 750 Ω, which is high enough for a normal cable run but is not unlimited: the resistance of the cable and of the receiving instrument has to stay inside it, or the transmitted current can no longer be regulated and the value read at the far end drifts away from the value measured without any fault being indicated.

The alarm contacts are relay contacts, and the material states their switching capacity rather than their type alone. The flagship carries three SPST contacts, two for alarms and one for cleaning, in normally open and normally closed form, rated 250 VAC / 5 A. The other two tiers carry two contacts rated AC 250 V / 3 A. A dosing pump or a solenoid valve within those ratings can be switched directly; above them, or on an inductive load, the material’s own advice is to interpose a relay so that the instrument switches a coil rather than the load. That keeps the contacts inside their rating and moves the wear to a replaceable part.

Measurement limitations and selection considerations

The ±0.02 pH figure is the electrical accuracy of the controller. It is not the accuracy of the installed measurement, which is set by the electrode’s condition and age, by the freshness of the buffers it is calibrated against, by whether the compensation matches the actual stream, and by the medium itself. A coated bulb or a partly blocked reference junction moves the reading far more than the controller’s own error, which is why the routine that matters is cleaning, calibrating in fresh buffer, and replacing an electrode that will no longer pass rather than recalibrating one that has failed.

Several parameters are not stated anywhere in the material: the ingress protection rating, the ambient temperature and humidity limits, and the dielectric strength. Nothing here is inferred to fill those gaps. They are listed as information required, and the material’s own note that all figures are the supplier’s nominal values, to be confirmed against the delivered nameplate and manual, applies to the whole page.

Panel mounting also fixes an installation detail worth thinking about before the cut-out is made. The material illustrates a 15 degree angled electrode installation, which is a recommendation about how the sensor should sit so that its sensitive membrane contacts the medium fully and bubbles do not collect on it; it is not a second way of mounting the controller. The controller itself is a recessed panel instrument whose bezel sits at the panel face, and the material notes that where the artwork shows both arrangements the delivered manual governs.

Where a reading has to be taken to a sample rather than held in a line, the instrument is the wrong one: a pH meter is carried to the sample and read there, and it needs no supply, no wiring and no panel cut-out. The analyzer exists because the reading has to stay in place and drive something. Where the requirement is a single spot check, or a field survey across many points, the meter is both cheaper and more practical.

Ordering

A quotation can be issued from the duty described in the enquiry. The items that decide the answer are the medium and its temperature, the pH or ORP range expected and the band that has to be held, the line pressure and whether it varies, the mounting arrangement available at the measuring point and how much access there is for removal, how many values have to be transmitted and what will read them, whether the reading must drive dosing or only be recorded, the panel supply available, and the ingress protection the location calls for. Quantity, destination port and required delivery date complete it.

Features

  • One pH accuracy figure across all three tiers, so the cheaper enclosure does not cost reading accuracy
  • A flagship tier with two isolated current outputs, which is what a loop needs when pH and temperature both have to be transmitted
  • A dedicated cleaning contact on the flagship, so a jet or brush cleaner can be sequenced without borrowing an alarm relay
  • Alarm contacts rated for direct switching of a dosing pump or a valve at 250 VAC
  • Isolated outputs as standard, which avoids a ground loop between the instrument and the control system it feeds
  • Acid, alkali and pure water compensation on the flagship, covering the streams where a plain linear compensation is the wrong model

Technical specifications

Every value below is taken from source documentation. Where a parameter is not stated in the available material it is marked as information required rather than estimated.

Measurement
pH range, flagship-(2.00~16.00) pH, antimony electrode supportedStandard
pH range, upgrade and economy0~14 pHStandard
ORP range, flagship±2000 mVStandard
ORP range, upgrade-1000~+1000 mV, with ±2000 mV available to orderStandard
ORP range, economy-1000~+1000 mVStandard
pH accuracy±0.02 pH, all three tiersStandard
ORP accuracy±2 mV flagship; ±1 mV upgrade; not stated for the economy tierInformation required
Temperature compensation, flagshipManual, plus automatic linear compensation; acid and alkali compensation and pure water compensation supportedStandard
Temperature compensation, upgradeNTC10K or Pt1000, -10 to 130°CStandard
Temperature compensation, economyNTC10K, -10 to 130°CStandard
Output and control
Transmitter output, flagshipIsolated, 2 channels (0/4~20) mA assignable across the measuring range; accuracy ±0.1 %FS; meets NAMUR NE43Standard
Transmitter output, upgrade and economyIsolated, (4~20) mA assignable across the pH or ORP range; accuracy ±0.2 %F.SStandard
Load capability750 Ω maximum on all tiersStandard
Alarm contacts, flagship3 x SPST, 2 alarm plus 1 cleaning, normally open and normally closed, 250 VAC / 5 AStandard
Alarm contacts, upgrade and economy2 contacts, AC 250 V / 3 AStandard
WiringTerminal block for supply, electrode, transmitter output and alarm contactsStandard
Supply and environment
Supply, flagshipAC (85~265) V, 50/60 Hz; DC (21.6~26.4) VStandard
Supply, upgradeAC 220 V ±10 %, 50/60 Hz; DC 24 V ±20 %; input power not less than 6 WStandard
Supply, economyAC 220 V ±10 %, 50 Hz; DC 24 VStandard
Ingress protectionInformation requiredInformation required
Ambient temperature and humidityInformation requiredInformation required
Dielectric strengthInformation requiredInformation required
Construction
MountingPanel-mount, recessed, with the front bezel at the panel faceStandard
Front panelLiquid crystal display with membrane keysStandard
Case dimensions, flagship151 x 144 x 118 mmStandard
Case dimensions, upgrade100 x 100 x 150 mmStandard
Case dimensions, economy96 x 96 x 112 mmStandard
Case materialInformation requiredInformation required
Electrode mounting angleThe supplied material illustrates a 15 degree angled electrode installation for the sensor; the recessed panel mount is the fixing of the controller itselfStandard
Matching electrodes, partial list
MIK-ASP2110Plastic-body pH electrode, for continuous online monitoringOptional
MIK-pH-2065Glass pH electrode, general water qualityOptional
MIK-pH-7001Glass pH electrode, general water qualityOptional
MIK-pH-5022Glass pH electrode, general water qualityOptional
MIK-pH-5013AGlass pH electrode, general water qualityOptional
MIK-pH-5015Glass pH electrode, general water qualityOptional
Ranges, temperature limits and threadsInformation required - the supplied material lists these models without a parameter table for eachInformation required

Available models

Selection table
Model Configuration Key ranges Availability
MIK-pH8.5 Flagship tier, 4.3 inch display, case 151 x 144 x 118 mm pH -(2.00~16.00) with antimony electrode support; ORP ±2000 mV Two isolated (0/4~20) mA outputs at ±0.1 %FS meeting NAMUR NE43, and three SPST contacts including a cleaning relay. Supply AC (85~265) V or DC (21.6~26.4) V
MIK-pH6.5 Upgrade tier, 2.8 inch display, case 100 x 100 x 150 mm pH 0~14; ORP -1000~+1000 mV, with ±2000 mV made to order One isolated (4~20) mA output at ±0.2 %F.S and two contacts at AC 250 V / 3 A. Temperature compensation accepts NTC10K or Pt1000 from -10 to 130°C
MIK-pH163S Economy tier, 2.8 inch display, case 96 x 96 x 112 mm pH 0~14; ORP -1000~+1000 mV One isolated (4~20) mA output at ±0.2 %F.S and two contacts at AC 250 V / 3 A. Temperature compensation is NTC10K only, and the ORP accuracy figure is not stated

Customization

  • ORP range extended to ±2000 mV on the upgrade tier, and manufactured to order where the standard list does not cover the duty
  • Electrode selected from the matching range to suit the medium, temperature and connection thread
  • Supply arrangement chosen between the AC and DC options offered on the selected tier

Certification and compliance

Certification documents not yet supplied

Certifications are only published once a certificate copy can be produced, so this section is deliberately empty rather than populated with assumed approvals. Tell us which approvals your application requires and we will confirm what is available for this instrument.

Parameters still to be confirmed

The following are required for a complete specification but are not stated in the documentation supplied to us. They are listed rather than estimated:

  • Ingress protection rating for each of the three case sizes
  • Ambient temperature and humidity limits for operation and storage
  • Dielectric strength and insulation figures
  • Case and bezel material, and whether the panel gasket is supplied
  • Ranges, temperature limits, pressure limits and connection threads for each matching electrode model
  • Whether a controller is supplied with an electrode, since the material does not state what a single unit contains
  • Whether an antimony electrode is available from the same range as the glass models listed
  • Certificate list and the current validity of each document, including any hygiene approval for potable water contact
  • Warranty period and the terms that apply
  • English-language datasheet, wiring diagram and panel cut-out drawing
  • Packaging dimensions and gross weight for each tier

Frequently asked questions

What actually separates the three tiers?

Not the pH reading. All three quote ±0.02 pH, and they share the same electrode chemistry. What changes is the enclosure and what comes out of it: the flagship has a 4.3 inch display, two isolated current outputs at ±0.1 %FS, three contacts including a dedicated cleaning relay, a wide-range AC supply and a wider pH span with antimony electrode support. The two smaller tiers have a single current output at ±0.2 %F.S, two contacts, an AC 220 V supply, and on the economy tier a narrower ORP figure is not even stated. Where the loop only has to report one value and drive one relay, the smaller tier does the same job in a 96 x 96 mm cut-out.

Do I need the ORP measurement as well as pH?

They answer different questions. pH measures hydrogen ion activity; ORP measures the tendency of the solution to oxidise or reduce, in millivolts. Disinfection control is usually an ORP duty, because the sanitising power of a chlorinated stream depends on more than its pH, while a neutralisation loop is a pH duty. Where a regulation names both, both are measured and neither substitutes for the other. The controllers here take either electrode, but a single instrument reads one of them at a time, so a loop that regulates both needs two measuring points.

How accurate is the installed reading, given the ±0.02 pH figure?

±0.02 pH is the electrical accuracy of the controller, and it says nothing about the electrode standing in the process. The accuracy of the installed loop is set by the electrode's condition and age, by the buffers it is calibrated against, by whether the temperature compensation matches the actual stream, and by the medium itself. A coated bulb or a partly blocked reference junction will move the reading far more than the controller's own error. That is why the routine that matters is cleaning, calibrating in fresh buffer, and replacing the electrode when it no longer passes rather than recalibrating an electrode that has failed.

Why does the material warn about load on the current output?

Because the output is a current source with a finite voltage available, the resistance of everything in the loop - the receiving instrument and the cable - has to stay within the stated load. At 750 Ω the output holds its accuracy; beyond it the current can no longer be regulated and the transmitted value drifts away from the measured one without any fault appearing. Long cable runs are the usual reason a loop exceeds the figure, so the resistance of the run and of the receiving device is worth adding up before the cable is pulled.

Can one controller handle the electrode, the alarms and the dosing at the same time?

Yes, within the contact rating. The relay contacts are rated for the stated voltage and current, and a dosing pump or a solenoid valve within that rating can be switched directly. Above it, or where the load is inductive, the usual arrangement is an interposing relay: the controller drives the relay coil, and the relay switches the load. That keeps the instrument's contacts inside their rating and puts the contact wear on a part that is cheap to replace. The cleaning contact on the flagship is separate from the two alarm contacts for the same reason, so the cleaning cycle can be sequenced without competing with the alarm function.

Related products

Other models in the same range

Hand-held pen shaped pH meter with a light grey body, a dark grey cap at the top and a tapered probe at the foot, its display showing 7.49 pH above a reading of 30.1 degrees Celsius, with three buttons below the screen

PH848 (5 models) · pH Meters

Pen Type pH Meter

Pen type pH meters in five models across two accuracy grades, with the electrode and the display in one hand-held body, automatic temperature compensation and a selectable probe form.

Models
PH848, PH838, PH818, PH828 and PH828+ across two accuracy grades
pH range
0.0~14.0 on PH848; 0.00~14.00 on PH838, PH818, PH828 and PH828+
Resolution and accuracy
0.1 resolution at ±0.1 pH on PH848; 0.01 resolution at ±0.05 pH on the other four
Repeatability
0.1 on PH848; 0.03 on the other four

Request a quotation for the MIK-pH8.5

Send the configuration you need and we will confirm availability, lead time and terms. Minimum order quantity is 1 pc.

Request for quotation

Request a quotation - MIK-pH8.5

Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.

The more of this you can give us, the fewer exchanges are needed before we can quote.