KS8651 (6 models) ·

Key specifications

Maximum test voltage
60 V
Maximum test current
10 A
Maximum test power
150 W on the standard models, 300 W on the H models
Port arrangements
Single module with 4 ports; four modules with 4 or 8 ports
Voltage and current accuracy
±(0.05% + 0.05% FS) on both
Resolution
0.5 mV on voltage, 0.5 mA on current
Protocols
QC2.0, QC3.0, PD2.0, PD3.0 and PD3.1; AFC, FCP, SCP and SSCP optional
Load modes
Constant current or constant voltage
Display
8-inch touchscreen, Android host with dedicated software
Body
487.6 × 181 × 430 mm

A multi-port charger rarely fails by delivering nothing. It fails by negotiating the wrong profile, dropping out of constant current early, or tripping its protection at a current the label never promised. Those are behaviours a bench meter cannot see, because they only appear while the charger is loaded and talking. This range tests them with the load built in.

Product overview

Six models share one test engine and differ in two things: how the ports are arranged, and how much power each port can absorb. The single-module version presents four ports on one module. The four-module versions present four or eight ports, and they alone support testing each channel independently and combining ports in one test.

The instrument is a bench unit. An 8-inch Android touchscreen with dedicated software is the operating front end, and the rear panel carries the signal, output, input, serial, network and fan positions. Results can be written to a USB storage device from the front socket, which is the simplest way to get a run out of the instrument without a network.

How the fast-charge tester works

Testing a fast charger is a conversation before it is a measurement. The instrument presents itself as a sink, reads the power data objects the charger advertises, requests a voltage from that list, and waits for the charger to settle before closing the load. Only then does the current reading mean anything.

Once the load is closed, voltage and current are sampled at the port and power is derived from the pair. Because the lead and the connector have resistance, the voltage at the instrument is lower than the voltage at the charger’s output; remote sensing is provided so that regulation is judged at the charger rather than at the end of the cable.

Protection point testing is a separate routine. The load is increased until the charger’s over-current or over-power protection operates, and the current at that moment is recorded. A PPS sweep steps the requested voltage across the programmable range and records the response at each step, while PDO and VDM tests read back what the charger claims it can do. The two views are not the same: a charger can advertise a profile it cannot hold under load, and that gap is what these tests expose.

How to select the right fast-charge tester

Start with the product’s port layout, because it decides the model family before any electrical question. A charger with four ports that share one supply is served by the single-module version. A charger whose ports must be checked at the same time, or a product with eight ports, needs a four-module version.

The second question is power per port. The standard models and the H models differ on this alone; the port count and the protocol set are otherwise the same, so the suffix is chosen by the largest load the product is expected to pull, with margin for the protection test, which deliberately drives the charger past its rating.

The third question is the protocol list. The standard set covers QC2.0, QC3.0, PD2.0, PD3.0 and PD3.1. AFC, FCP, SCP and SSCP are options, so a product built for those protocols has to be declared at the order stage rather than discovered at commissioning.

Finally, decide how results leave the instrument. Export to a USB device suits a bench that records per-unit results by hand; the optional host software suits a line that wants the results in a database. Send the port layout, the power per port and the protocol list, and a configuration can be proposed against them.

Measurement limitations and selection considerations

The built-in load makes this a DC-side instrument. The function table leaves the rows for AC electrical parameters, high and low voltage testing, AC power and a variable-frequency source blank, so an adapter’s mains-side behaviour, standby consumption and input regulation are outside what this unit is documented to do. A power meter or a separate AC source is needed alongside it for those.

The four-module models test channels independently, but they are not four separate instruments: the ports share one enclosure, one supply and one set of program storage. A test sequence that assumes one port can be reconfigured while another is running should be checked against the way the channels are grouped.

Lead resistance is part of every reading. On a charger delivering a high current at a low voltage, a long or thin cable drops enough to move the result, which is why remote sensing exists and why the lead set should be fixed for a product rather than swapped between benches. The material does not list the supplied lead set, so its length and rating have to be confirmed before the fixture is designed.

Features

  • A built-in electronic load on every port, so a charger is tested under the current it will actually deliver rather than open-circuit
  • Protocol negotiation up to PD3.1, with PPS sweep, PDO and VDM readback for chargers whose advertised profile has to be verified
  • Over-current protection point testing that records the current at which the charger trips, instead of only reporting pass or fail
  • Independent channel testing on the four-module models, for products whose ports share a supply and must be checked at the same time
  • Storage for 120 files and 100 program steps, enough for a line that runs several charger variants in a shift
  • Results exported as a document to a USB storage device, and optional host software for computer control
  • An 8-inch Android touchscreen as the operating front end, with RS-232C, LAN and WIFI for connection to a line system

Technical specifications

Every value below is taken from source documentation. Where a parameter is not stated in the available material it is marked as information required rather than estimated.

Measurement
Maximum test voltage60 VStandard
Maximum test current10 AStandard
Maximum test power150 W standard models; 300 W H modelsStandard
Voltage accuracy±(0.05% + 0.05% FS)Standard
Current accuracy±(0.05% + 0.05% FS)Standard
Voltage resolution0.5 mVStandard
Current resolution0.5 mAStandard
Load modeCC or CVStandard
Ripple measurementSupportedStandard
Remote voltage sensingSupportedStandard
Channels and sequencing
Channel count4 ports on a single module; 4 ports on four modules; 8 ports on four modulesStandard
Independent test per channelSupported on the four-module models onlyStandard
Combined multi-port testSupportedStandard
Program steps100Standard
Stored files120Standard
Working modeProduction or research and developmentStandard
Fast-charge functions
Protocol detectionSupportedStandard
PD3.1 range28 V 5 A on the standard models and 48 V 5 A on the H models, as printed in the parameter tableStandard
PPS sweepSupportedStandard
PDO testSupportedStandard
VDM testSupportedStandard
Built-in E-MarkerSupportedStandard
CC lead reverse-insertion testSupportedStandard
D+ and D- polarity testSupportedStandard
AFC, FCP, SCP, SSCPOptionalOptional
Protection and recording
Protection modesOCP, OVP, OPP and OTPStandard
Over-current protection point testSupportedStandard
Capacity meterSupportedStandard
Power meterSupportedStandard
Result exportSupported, to a USB storage deviceStandard
Host softwareOptional, for computer control and data storageOptional
Interfaces
CommunicationsRS-232C, LAN, WIFIStandard
Signal and controlSIGNAL, OUTPUT and INPUT sockets on the rear panelStandard
USBFront USB socket for file import and exportStandard
Supply and environment
Supply voltage100 to 240 V ACStandard
Supply frequency50 or 60 HzStandard
Operating temperature−10 to 50 °CStandard
Operating humidity70% RH or belowStandard
Mechanical
Dimensions487.6 mm wide, 181 mm high, 430 mm deepStandard
WeightNot stated in the materialInformation required

Available models

Selection table
Model Configuration Key ranges Availability
KS8651 Single module, 4 ports 60 V, 10 A; 150 W The entry model; no independent channel testing
KS8651H Single module, 4 ports 60 V, 10 A; 300 W Higher power on the same port count
KS8652 Four modules, 4 ports 60 V, 10 A; 150 W Independent channel testing available
KS8652H Four modules, 4 ports 60 V, 10 A; 300 W Four modules at the higher power
KS8653 Four modules, 8 ports 60 V, 10 A; 150 W Highest port count
KS8653H Four modules, 8 ports 60 V, 10 A; 300 W Eight ports at the higher power

Customization

  • AFC, FCP, SCP and SSCP protocol support as a factory option
  • Host communication software for computer control and result storage
  • Cable and adaptor sets for a particular connector layout

Certification and compliance

Certification documents not yet supplied

Certifications are only published once a certificate copy can be produced, so this section is deliberately empty rather than populated with assumed approvals. Tell us which approvals your application requires and we will confirm what is available for this instrument.

Parameters still to be confirmed

The following are required for a complete specification but are not stated in the documentation supplied to us. They are listed rather than estimated:

  • The weight of the instrument, which the dimension page does not state
  • Which PD3.1 band applies to each of the six models, since the model cards list the protocol by name only while the parameter table gives 28 V 5 A and 48 V 5 A by column
  • Whether the blank rows for AC electrical parameters, high and low voltage testing, AC power and a variable-frequency source mean unsupported or optional
  • Whether AFC, FCP, SCP and SSCP are factory-fitted options or field upgrades
  • The meaning of the marker printed against PD3.1 testing in the KS8651 column, which differs from the other five columns
  • The contents of the supplied lead and adaptor set, which the material does not list
  • Calibration certificate availability and the standard it is issued against
  • Warranty period and terms

Frequently asked questions

How many ports can be tested at the same time?

It depends on the model. The single-module version presents four ports on one module and tests them as one group. The four-module versions present four or eight ports across four modules, and those are the models that support independent testing of each channel and combined multi-port testing.

What has to be confirmed before a quotation?

The number of ports on the product, the power each port has to absorb, which fast-charge protocols the product advertises, and whether the ports must be tested independently. The last point decides whether a single-module or a four-module model is required, and it cannot be added later.

Can the instrument measure the mains input of an adapter?

The function table in the material leaves the rows for AC electrical parameters, high and low voltage testing, AC power and a variable-frequency source blank. Whether those are unsupported or optional is not stated, so mains-side measurement should be planned as separate equipment until the supplier confirms it.

Does it test the cable as well as the charger?

It tests the port and the lead together, since the load is applied through the connector. Reverse insertion of a CC lead and the polarity of the D+ and D− lines are both checked, and remote voltage sensing is provided so that regulation can be judged at the charger rather than at the end of the lead.

Related products

Other models in the same range

Benchtop digital power meter in a pale case, front view with a wide black display showing four stacked numeric lines against the A, B, C and D channel labels, and a keypad with a rotary confirm control to the right of the display

YP9901 (3 models) · Power Meters

Single-Phase Digital Power Meter

Panel digital power meter reading voltage, current, active power, power factor, frequency, apparent and reactive power in four windows at once, with an RS232 Modbus RTU port as standard and current ratings from 20 A to 200 A.

Basic accuracy
±0.2 % (0.2 class)
Measurement mode
AC on the AC series; AC, DC and RMS on the AC/DC series
Voltage input
3 to 600 V AC; 3 to 600 V AC + DC on the AC/DC series
Current ranges
5 mA to 20 A up to 50 mA to 200 A, according to series and rating
Compact programmable safety tester shown from the front with the two-line LCD at the upper left, a row of function keys beneath it and the test terminals along the lower right

7110 (8 models) · Electrical Safety Testers

Compact AC/DC Withstand Voltage and Insulation Tester

Compact programmable safety tester with 5 kV AC and 6 kV DC withstand voltage, insulation resistance to 9999 MΩ, five stored programs and PLC remote control.

AC output
0 to 5.00 kV, 12 mA
DC output
0 to 6.00 kV, 5 mA, on four of the eight models
Frequency
50 or 60 Hz, selectable
Leakage limits
0.10 to 12.00 mA AC and 0.02 to 5.00 mA DC, upper and lower set independently

Request a quotation for the KS8651

Send the configuration you need and we will confirm availability, lead time and terms. Minimum order quantity is 1 pc.

Request for quotation

Request a quotation - KS8651

Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.

The more of this you can give us, the fewer exchanges are needed before we can quote.
No file chosen
Datasheet, drawing, BOM or photograph. One file, up to 10 MB (PDF, Office, image or ZIP).

By submitting this form you agree that we may contact you about this enquiry. We do not sell or share enquiry data. See our privacy policy.

Items held in stock are dispatched within 48 hours of order confirmation. Customized specifications are produced to order and typically ship within 2 to 10 days. Transit time then depends on the shipping method and destination.

Request a Quote WhatsApp