Electrical Test & Measurement · Power Meters

Single-Phase Digital Power Meter

Panel digital power meter reading voltage, current, active power, power factor, frequency, apparent and reactive power in four windows at once, with an RS232 Modbus RTU port as standard and current ratings from 20 A to 200 A.

YP9901 (3 models) ·

Key specifications

Basic accuracy
±0.2 % (0.2 class)
Measurement mode
AC on the AC series; AC, DC and RMS on the AC/DC series
Voltage input
3 to 600 V AC; 3 to 600 V AC + DC on the AC/DC series
Current ranges
5 mA to 20 A up to 50 mA to 200 A, according to series and rating
Measurement set
Voltage, current, active power, power factor, frequency, apparent power, reactive power, phase angle, average power and accumulated energy
Display
High-brightness LED, five digits, four windows
Interface
RS232 with Modbus RTU as standard; RS485 or relay output to order
Supply
220 V, or 85 to 265 V AC / 100 to 300 V DC
Panel cut-out
210 × 95 mm
Body
300.2 × 215 × 100.6 mm, about 2.3 kg

A power meter is bought to answer what a load is doing rather than what a supply is capable of. The instrument reads voltage and current at the same instant and computes everything else from that pair, which is the reason it cannot be replaced by two separate readings taken one after the other.

Product overview

The range covers single-phase measurement across three series. The alternating-current series is built for general electrical verification, a second version is aimed at efficiency work where the interesting figure sits far below rated load, and the third adds direct-current measurement for adapters, chargers and DC supplies.

What separates them in use is not resolution but the two ends of the current span. The top of the range decides the largest unit that can be tested, and the bottom decides whether a standby figure is a measurement or only a number on a display. Both ends are quoted per rating rather than per instrument, which is why a quotation for this family comes back as a series and a rating rather than as a model number alone.

How the meter works

Voltage across the load and current through it are sampled together and converted against a single timebase. Multiplying the two point by point and averaging the result over a whole number of cycles gives active power directly, without assuming that the waveform is sinusoidal or that the load is linear. Power factor then follows as the ratio of active power to the product of the root-mean-square voltage and current, and apparent and reactive power come from the same three quantities.

That arithmetic is the reason the instrument exists in this form. A rectified average multiplied by a rectified average gives the right answer only on a clean sine wave; a switched-mode supply, a dimmer or a drive produces a waveform for which the two differ, and the error runs in one direction. An instrument that samples and multiplies does not care about the shape of the waveform, which is why the same instrument can be trusted on both a heater and a power supply.

How to select the right power meter

Three answers settle the selection. The first is whether the duty includes direct current: if an adapter, a charger or a DC supply is to be characterised, the alternating-current series cannot substitute and the decision is made. The second is the current span at both ends, taken from the largest unit to be tested and the smallest consumption figure the test standard names. The third is the nature of the load, because a drive or a switching supply requires a conversion that agrees with the readings taken around it.

The remaining choices are made once and then fixed. A low-current series is the difference between measuring standby consumption and merely displaying it. An energy total with elapsed time turns a run into a consumption figure. An isolated bus or a relay output has to be ordered with the instrument, since neither can be added afterwards.

Measurement limitations and selection considerations

This instrument characterises a load at a bench or a test position. It does not diagnose the waveform that produced the reading: harmonic content, distortion, unbalance and transients belong to a power quality analyser, which is a different instrument with a different purpose. Where the question is why a figure is what it is rather than what the figure is, the power meter is the wrong end of the diagnostic chain.

Two operational limits follow from the same construction. High currents pass through an external shunt, so the accuracy of the highest ratings depends on a component that may not be part of the instrument; and the basic class figure applies under calibrated conditions, with the error growing as the power factor falls. Both are reasons to state the duty in the enquiry rather than to select from the parameter table alone.

Features

  • Four windows show voltage, current, active power and a fourth quantity of choice at the same time, so most tests need no scrolling
  • Voltage and current both range automatically, which removes the mis-set-range error from a bench test
  • An RS232 port running Modbus RTU is fitted as standard, so a controller can read the instrument without an adapter
  • Energy accumulation and elapsed time are computed internally, which turns a run into a consumption figure rather than a snapshot
  • A low-current series reaches down to 0.05 mA, which is the region where standby consumption is actually measured
  • The AC/DC series reads the direct output of an adapter, a charger or a supply, which an alternating-current instrument cannot characterise

Technical specifications

Every value below is taken from source documentation. Where a parameter is not stated in the available material it is marked as information required rather than estimated.

Measurement
Basic accuracy±0.2 %, stated by the material as 0.2 classStandard
Reference standard behind the classNot stated in the materialInformation required
Power factor range0.000 to 1.000 on the alternating-current series and the AC/DC series; 0.001 to 1.000 on the efficiency seriesStandard
Frequency range40 to 1000 Hz in the function specification, and 40 to 400 Hz in the selection table and the supply line; both carried as printedInformation required
Energy accumulationElapsed time and accumulated energy, displayed in kWh or in hoursStandard
Peak registersHighest voltage, current, active power, apparent power and reactive power seen during a runStandard
Conversion methodThe material does not state whether the alternating channels compute a true root mean square value or an average of the rectified waveformInformation required
RepeatabilityNot stated in the materialInformation required
Inputs and ranges
Voltage range switchingAutomaticStandard
Voltage input impedanceAbout 2 MΩ, stated for the voltage channelStandard
Current ratings20 A, 40 A, 80 A, 100 A and 200 A, according to seriesStandard
High-current connectionThe 100 A and 200 A ratings of the AC/DC series are used with an external shunt; whether the shunt is supplied is not statedInformation required
Update rateSettable from 1 to 20 readings per second, with fast, 200 ms and slow positionsStandard
Overload capacityNot stated in the materialInformation required
Working temperature and humidityNot stated in the materialInformation required
Ingress protectionNot stated in the materialInformation required
Interface and supply
Serial portRS232 with Modbus RTU, fitted as standardStandard
Optional interfaceIsolated RS485 or a relay output, ordered with the instrumentOptional
Supply voltage220 V nominal, or a wide-range 85 to 265 V AC / 100 to 300 V DC inputStandard
Supply frequency40 to 400 Hz as printed in the supply line of the materialStandard
Channel isolationNot stated in the materialInformation required
Mechanical
Body300.2 × 215 × 100.6 mmStandard
Panel cut-out210 × 95 mmStandard
WeightAbout 2.3 kgStandard
CaseMetal housingStandard
Rear connectionsLoad connector, supply socket and source terminalsStandard

Available models

Selection table
Model Configuration Key ranges Availability
YP9901 Alternating current only, single-phase, LED display, five current ratings from 20 A to 200 A 3 to 600 V AC; 5 mA to 20 A up to 20 mA to 200 A according to rating; power factor 0.000 to 1.000 The general series for alternating-current measurement. The 200 A rating starts at 20 mA rather than at 5 mA
YP1020 Alternating current only, for efficiency work, in a five-level and a six-level version Power factor 0.001 to 1.000; lowest current from 0.5 mA on the 20 A version and 0.05 mA on the 40 A version The series for standby and no-load consumption, where the figure of interest sits two or three decades below the rated load
YP2012 AC, DC and RMS, five current ratings from 20 A to 200 A 3 to 600 V AC + DC; 3 mA to 20 A up to 50 mA to 200 A; the 100 A and 200 A ratings use an external shunt The only series that can characterise a direct output, and therefore the one required for adapters, chargers and DC supplies

Customization

  • The current rating: 20 A, 40 A, 80 A, 100 A or 200 A, selected against the largest load to be tested
  • The communication option: an isolated RS485 port or a relay output, ordered with the instrument since neither can be added later
  • The supply variant: 220 V nominal, or the wide-range 85 to 265 V AC / 100 to 300 V DC input
  • The energy display: accumulated energy in kWh or elapsed time in hours
  • The low-current series, where standby consumption has to be measurable rather than merely displayed

Certification and compliance

Certification documents not yet supplied

Certifications are only published once a certificate copy can be produced, so this section is deliberately empty rather than populated with assumed approvals. Tell us which approvals your application requires and we will confirm what is available for this instrument.

Parameters still to be confirmed

The following are required for a complete specification but are not stated in the documentation supplied to us. They are listed rather than estimated:

  • The standard behind the 0.2 class accuracy figure
  • Whether the alternating channels compute a true root mean square value or an average of the rectified waveform
  • The overload capacity of the voltage and current channels
  • Working temperature, working humidity and ingress protection
  • Whether the external shunt needed for the 100 A and 200 A ratings is supplied with the instrument
  • The supply variant a specific quotation refers to, since the material quotes two
  • Battery or back-up behaviour, which the material does not describe
  • Whether the frequency range is 40 to 1000 Hz or 40 to 400 Hz, since the material states both
  • The full specification of the data-processing or test-system connection, including the register map
  • Warranty period and the terms that apply
  • An English-language datasheet for each series

Frequently asked questions

What decides whether an alternating-current instrument will do?

Whether any part of the duty is direct current. An adapter, a charger, a DC supply or a battery has an output that an alternating-current channel does not measure, so those duties force the AC/DC series. A mains-fed motor or a heater does not, and the alternating-current series is the simpler and less expensive choice for them.

Why is the current range quoted at both ends rather than only at the top?

Because the top of the range decides the largest load that can be tested and the bottom decides whether the smallest figure is a measurement or merely a number on a display. Standby and no-load consumption sit at the bottom, and an instrument whose lowest range is in milliamperes will report them poorly however good its accuracy class is.

What does the 0.2 class figure actually cover?

It is the basic error of the instrument under calibrated conditions, and the material points out that the figure in service also depends on the range in use, the power factor, the distortion of the waveform and the way the instrument is wired. At a low power factor the error grows well beyond the class figure, which is why the class alone does not describe how well a particular test will go.

What has to be confirmed before a quotation?

The supply and whether direct current is involved; the largest and smallest currents the tests require; the accuracy figure and the standard behind it; whether standby consumption is measured; the nature of the load, since a non-sinusoidal waveform requires a true root mean square conversion; whether a controller reads the result and over which interface; whether energy over a run has to be reported; and how the instrument is mounted.

Related products

Other models in the same range

Hand-held digital multimeter in an orange sleeve shown from the front with the LCD reading 19.99, the rotary range selector below it and four test sockets along the bottom edge, together with a second view of the same instrument from the side

DT9205A (3 models) · Digital Multimeters

Handheld Digital Multimeter

Handheld digital multimeter with a 1999-count display and 32 ranges covering AC and DC voltage and current, resistance, capacitance, diodes and transistors, with continuity, overload protection and automatic switch-off.

Display
1999 counts, 3½ digits
DC voltage
200 mV to 1000 V in five ranges
AC voltage
200 V and 750 V
DC and AC current
2 mA to 20 A
Clamp meter held in one hand by its body, with the orange transformer jaw at the top, a rotary function selector and three function keys below the display, and the two test sockets along the bottom face

3266TA (3 models) · Clamp Meters

AC/DC True-RMS Clamp Meter

Clamp meter range reading current through a 25 mm jaw without breaking the circuit, from an AC-only model up to an AC/DC instrument with true-RMS conversion, 6000 counts and a 100 mF capacitance range.

Jaw opening
25 mm
AC current
1 mA to 600 A on the two AC-only models; 10 mA to 600 A on the AC/DC model
DC current
10 mA to 600 A on the AC/DC model only
AC and DC voltage
AC 1 mV to 600 V; DC 0.1 mV to 600 V
A rectangular panel meter with a black bezel, showing a two-hundred-and-thirty volt reading in red digits and a current reading in blue digits, with a small split-core current transformer on a lead below it

AC-10A (3 models) · Panel Meters

Digital AC Panel Meter

Panel meter showing AC voltage and current together on two rows of digits, self-powered from the measured circuit and supplied with a split-core current transformer.

Voltage range
AC 60 to 500 V, for 220 V single-phase and 380 V three-phase circuits
Current ranges
10 A, 50 A and 100 A versions, the 10 A version resolving to 0.01 A
Supply
No separate supply; the measured voltage powers the instrument
Display
Two rows of digits, voltage in red and current in blue, with AC symbols on the right

Request a quotation for the YP9901

Send the configuration you need and we will confirm availability, lead time and terms. Minimum order quantity is 1 pc.

Request for quotation

Request a quotation - YP9901

Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.

The more of this you can give us, the fewer exchanges are needed before we can quote.
No file chosen
Datasheet, drawing, BOM or photograph. One file, up to 10 MB (PDF, Office, image or ZIP).

By submitting this form you agree that we may contact you about this enquiry. We do not sell or share enquiry data. See our privacy policy.

Items held in stock are dispatched within 48 hours of order confirmation. Customized specifications are produced to order and typically ship within 2 to 10 days. Transit time then depends on the shipping method and destination.

Request a Quote WhatsApp