Electrical Test & Measurement · Clamp Meters

AC/DC True-RMS Clamp Meter

Clamp meter range reading current through a 25 mm jaw without breaking the circuit, from an AC-only model up to an AC/DC instrument with true-RMS conversion, 6000 counts and a 100 mF capacitance range.

3266TA (3 models) ·

Key specifications

Jaw opening
25 mm
AC current
1 mA to 600 A on the two AC-only models; 10 mA to 600 A on the AC/DC model
DC current
10 mA to 600 A on the AC/DC model only
AC and DC voltage
AC 1 mV to 600 V; DC 0.1 mV to 600 V
Resistance
To 20 MΩ, 40 MΩ or 60 MΩ according to model
Capacitance
1 pF to 4000 µF on the middle model; 0.01 nF to 100 mF on the AC/DC model
Display count
1999, 3999 and 6000 according to model
Conversion
True root mean square on the AC/DC model; not stated for the other two
Safety rating
CAT 600 V as printed on the panel; one detail image states CAT II 600 V
Supply
Two AAA cells on the two AC-only models

A clamp meter exists because some conductors cannot be interrupted. Where the plant is running and the current is the thing being checked, nothing can be inserted into the circuit, and measuring from outside the conductor is the only method available rather than simply a convenient one.

Product overview

The range covers three instruments built on two different sensors. Two of them read alternating current through a transformer jaw and differ by the additional functions they carry; the third replaces that jaw with a Hall-effect sensor so that direct current can be measured as well, and adds true root mean square conversion and a higher display count.

That split is the first thing to settle. The two alternating-current models share the 25 mm jaw, the non-contact detection, the torch and the automatic ranging, and the difference between them is capacitance, temperature, frequency and relative measurement. The third is a different instrument underneath, and it is the only one of the three that can be taken to a battery bank or a drive output.

How the jaw measures current

Enclosing a conductor in a magnetic circuit couples the field it produces into the instrument. In a transformer jaw the coupling is inductive, so only a changing field produces a signal and a steady direct current produces nothing at all. In a Hall-effect jaw the core is gapped and an element senses the static field directly, which is what allows a direct current to be measured, at the cost of greater sensitivity to where the conductor sits between the jaws and of an offset that has to be zeroed out.

The rest of the chain follows the usual decision about alternating signals. An instrument that averages the rectified waveform is calibrated on a sine wave and under-reports as the waveform departs from one, whereas an instrument that computes the heating equivalent agrees with the other instruments on the same installation. That matters on drives and switching supplies and not at all on a resistive heater.

How to select the right clamp meter

The first question is whether direct current is anywhere in the duty, because that decides between two sensor types rather than between two specification levels. The second is the conductor: 25 mm of jaw opening sets a hard limit on what can be measured, and a jaw that does not close fully reads low rather than failing.

The remaining choices are about what else the instrument has to do. Capacitance and temperature are what turn a current check into a winding or capacitor check without a second instrument. A starting-current capture is what makes a motor start visible. The safety category at the point of measurement is a separate question from all of these, and it is a limit on what the instrument survives rather than on how well it measures.

Measurement limitations and selection considerations

The method has a floor. A small current produces a small field, and at the bottom of the range the reading becomes unreliable in a way that no amount of display resolution fixes; a low alternating current is better measured by inserting an instrument into the circuit, and a low direct current needs the jaw zeroed before it means anything. Reading a cable that carries both the outgoing and the returning conductor cancels the field and gives a reading near zero, which is why only a single conductor is enclosed.

The instrument reports current and nothing more. Power, power factor and energy need voltage as well, taken at the same time, and a clamp meter that reads only current cannot answer a consumption question however large its range. Where the load is a drive or a switching supply, the conversion method becomes part of the specification, and an instrument without true root mean square conversion will disagree with the rest of the site measurements.

Features

  • A 25 mm jaw takes the conductors met on distribution and machine wiring, and the conductor does not have to be disconnected to be measured
  • The AC/DC model reads direct current as well as alternating, which the transformer-based models in the same range cannot do
  • True root mean square conversion on the AC/DC model gives readings on drives and switching supplies that agree with the instruments around them
  • Non-contact voltage detection on all three models gives a warning before the jaws go around a conductor
  • A torch on the body lights the conductor being clamped
  • Data hold, automatic ranging and automatic switch-off across the range
  • A capacitance range reaching 100 mF on the AC/DC model, which covers motor and compressor capacitors

Technical specifications

Every value below is taken from source documentation. Where a parameter is not stated in the available material it is marked as information required rather than estimated.

Measurement
AC current accuracy±(3 % + 5) on the lower model and ±(2.5 % + 5) on the middle model; ±(2.5 % + 3) on the AC/DC modelStandard
AC voltage accuracy±(1.2 % + 5) on the two AC-only models; ±(1.0 % + 4) on the AC/DC modelStandard
DC voltage accuracy±(0.8 % + 5) on the two AC-only models; ±(0.5 % + 5) on the AC/DC modelStandard
DC current accuracy±(3.0 % + 3) on the AC/DC model onlyStandard
Resistance accuracy±(1.2 % + 5) on the two AC-only models; ±(0.8 % + 5) on the AC/DC modelStandard
Capacitance accuracy±(3 % + 5) on the middle model; ±(4.0 % + 5) on the AC/DC modelStandard
Frequency accuracy±(0.5 % + 5) on the middle model; ±(1.5 % + 5) on the AC/DC modelStandard
Temperature accuracy±(3 % + 5) on the middle model; ±(1.0 % + 3) on the AC/DC modelStandard
Sampling rateThree readings per second on the AC/DC model; not stated for the other twoStandard
Functions by model
True root mean squareThe AC/DC model is described as true root mean square; the material does not state the conversion used on the other twoInformation required
Non-contact voltage detectionPresent on all three models, with the buzz rate and the display indication rising with the field strengthStandard
Torch and backlightPresent on all three modelsStandard
Data hold and automatic rangingPresent on all three modelsStandard
Relative measurementThe middle model and the AC/DC modelStandard
Zeroing for direct currentThe material describes a zeroing mode on the AC/DC modelStandard
Overload protectionA built-in protection fuse with a high-performance chipset, as described by the materialStandard
Electrical and mechanical
SupplyTwo AAA cells on the two AC-only models; not stated for the AC/DC modelInformation required
Body183 × 47 × 25 mm across the range; one table prints the AC-only figure with centimetres, which the material itself identifies as a probable misprintStandard
Weight165 g on the AC/DC model; not stated for the other twoStandard
CAT ratingCAT 600 V on the panel; one detail image states CAT II 600 V at that figureInformation required
Working temperatureNot stated in the materialInformation required
Supplied setColour box, manual, cells, pouch, test leads and a screwdriver set; a temperature probe on the middle and AC/DC modelsStandard

Available models

Selection table
Model Configuration Key ranges Availability
3266TA AC-only clamp meter, 1999 counts, two AAA cells AC current 1 mA to 600 A; resistance to 20 MΩ; no capacitance, frequency or temperature; a temperature probe is not supplied The simplest of the three, for alternating current and voltage with continuity
3266TD AC-only clamp meter adding capacitance, temperature, frequency and relative measurement; 3999 counts Capacitance 1 pF to 4000 µF; frequency 0.01 Hz to 10 MHz; resistance to 40 MΩ; temperature -20 to 1000 °C For service work where a winding or a capacitor has to be checked at the same time as the current
328D AC and DC, true root mean square, 6000 counts, 165 g DC current 10 mA to 600 A; capacitance 0.01 nF to 100 mF; resistance to 60 MΩ; temperature -20 to 1000 °C For DC banks, drive outputs and any load whose waveform is not a clean sine wave

Customization

  • The test leads: standard, pointed or silicone, according to the version ordered
  • A temperature probe, supplied with the middle and AC/DC models and not with the lower one
  • A rechargeable set with charger, offered as a version of the middle model
  • Jaw opening, which is fixed at 25 mm across the range

Certification and compliance

Certification documents not yet supplied

Certifications are only published once a certificate copy can be produced, so this section is deliberately empty rather than populated with assumed approvals. Tell us which approvals your application requires and we will confirm what is available for this instrument.

Parameters still to be confirmed

The following are required for a complete specification but are not stated in the documentation supplied to us. They are listed rather than estimated:

  • The conversion method used on the two AC-only models, which the material does not state
  • The CAT rating a quotation refers to, since the panel and one detail image give different category levels at 600 V
  • The working temperature range
  • The battery arrangement of the AC/DC model, which the material does not state
  • Whether the instrument is approved for use in a classified area, which the material does not address
  • Whether a calibration certificate is available and to what standard
  • The official designation of the AC/DC model and its relation to the two digit designations of the other models
  • Warranty period and the terms that apply
  • An English-language manual and datasheet

Frequently asked questions

Which model is needed for a drive output or a battery bank?

The AC/DC model, and for two separate reasons. A transformer jaw responds only to a changing field, so the two AC-only models read nothing on a steady direct current. The AC/DC model also carries true root mean square conversion, which is what makes its alternating readings on a drive comparable with the instruments used around it.

How far can a reading be trusted when the conductor is clamped rather than connected?

Further than the method might suggest for a rough figure, and not far enough for a precise one. The reading depends on the conductor sitting well inside closed jaws, on the absence of other fields nearby, and on the jaw being fully closed. A direct-current reading adds the sensor offset, which is why that model has a zeroing function and a lower accuracy figure than the alternating ranges.

Does a clamp meter measure power?

No, unless it is specifically built to read voltage at the same time. It reports the current in the conductor, which is enough to judge loading and balance but says nothing about how much work the load is doing. A load at a low power factor can carry a large current for very little power, and only a power meter reports that difference.

What has to be confirmed before a quotation?

The largest conductor to be clamped, against the 25 mm jaw; whether direct current is involved anywhere in the duty; the currents of interest at both ends of the range, including any leakage figure; the point of measurement and the safety category that goes with it; and whether a temperature probe or a particular lead set is wanted.

Related products

Other models in the same range

Benchtop digital power meter in a pale case, front view with a wide black display showing four stacked numeric lines against the A, B, C and D channel labels, and a keypad with a rotary confirm control to the right of the display

YP9901 (3 models) · Power Meters

Single-Phase Digital Power Meter

Panel digital power meter reading voltage, current, active power, power factor, frequency, apparent and reactive power in four windows at once, with an RS232 Modbus RTU port as standard and current ratings from 20 A to 200 A.

Basic accuracy
±0.2 % (0.2 class)
Measurement mode
AC on the AC series; AC, DC and RMS on the AC/DC series
Voltage input
3 to 600 V AC; 3 to 600 V AC + DC on the AC/DC series
Current ranges
5 mA to 20 A up to 50 mA to 200 A, according to series and rating
Hand-held digital multimeter in an orange sleeve shown from the front with the LCD reading 19.99, the rotary range selector below it and four test sockets along the bottom edge, together with a second view of the same instrument from the side

DT9205A (3 models) · Digital Multimeters

Handheld Digital Multimeter

Handheld digital multimeter with a 1999-count display and 32 ranges covering AC and DC voltage and current, resistance, capacitance, diodes and transistors, with continuity, overload protection and automatic switch-off.

Display
1999 counts, 3½ digits
DC voltage
200 mV to 1000 V in five ranges
AC voltage
200 V and 750 V
DC and AC current
2 mA to 20 A

Request a quotation for the 3266TA

Send the configuration you need and we will confirm availability, lead time and terms. Minimum order quantity is 1 pc.

Request for quotation

Request a quotation - 3266TA

Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.

The more of this you can give us, the fewer exchanges are needed before we can quote.
No file chosen
Datasheet, drawing, BOM or photograph. One file, up to 10 MB (PDF, Office, image or ZIP).

By submitting this form you agree that we may contact you about this enquiry. We do not sell or share enquiry data. See our privacy policy.

Items held in stock are dispatched within 48 hours of order confirmation. Customized specifications are produced to order and typically ship within 2 to 10 days. Transit time then depends on the shipping method and destination.

Request a Quote WhatsApp