- Display
- 1999 counts, 3½ digits
- DC voltage
- 200 mV to 1000 V in five ranges
- AC voltage
- 200 V and 750 V
- DC and AC current
- 2 mA to 20 A
- Resistance
- 200 Ω to 200 MΩ
- Capacitance
- 20 nF to 200 µF; to 2000 µF on the upper two models
- Frequency
- 0 to 2000 Hz on the top model only
- Special functions
- Continuity buzzer, diode and transistor test, automatic switch-off, overload protection on every range
- Ports
- 20 A, mA, COM and VΩ
- Body
- 192 × 90 × 38 mm on the base model; 187 × 90 × 43 mm on the other two
A multimeter is the instrument most often bought on price, and the specifications that decide whether it survives the job are the ones least often read. This page sets out what the three models in the range actually differ by, and which of the differences matter at the point of use.
Product overview
The range covers one instrument at three levels. All three share a 1999-count display, the same voltage, current, resistance and capacitance ranges, a continuity buzzer, transistor and diode tests, and automatic switch-off. What separates them is a short list of additions, and each addition answers a specific situation rather than adding a specification for its own sake.
That structure is worth knowing before an order is placed, because the middle and top models cost more for reasons that are functional and not cosmetic. A backlight matters in a plant room and nowhere else; a resettable fuse in the current socket matters to whoever has to keep the instrument in service after it has been mis-connected.
How the meter works
The instrument converts whatever is being measured into a small voltage and compares it against an internal reference. Voltage and resistance are read directly against that reference; current is read as the drop across a shunt, which is why the instrument has to be placed in series with the load and why the current sockets have a fuse in them.
The consequences of that construction are the practical limits of the type. Current passes through the instrument, so the ranges stop well below what an industrial feeder carries, and the whole load current flows through a fuse that is there to protect the instrument rather than the circuit. The display count sets the smallest change that can be shown on a given range, which is a resolution figure and not an accuracy figure, and the two are frequently confused when instruments are compared on a specification sheet.
How to select the right multimeter
Two questions settle most of the choice. The first is what has to be measured beyond voltage, resistance and continuity: capacitance points to the middle model or above, and frequency or the tracing of a live conductor points to the top one. The second is where the instrument will be used, since a dark plant room or an instrument kept in a maintenance kit both argue for additions the entry model does not have.
The rest is about how the instrument will be treated. A resettable fuse removes the need for a spare part and a return to service delay after a mis-connection, which is why it appears on the top model only. A removable sleeve and a rear stand decide whether the instrument can be stood up to be read while both hands are occupied.
Measurement limitations and selection considerations
The range stops at 20 A, and the current measurement requires the circuit to be broken and the instrument inserted. Where the conductor carries more than a few amperes, or where it cannot be interrupted because the plant is running, this is the wrong instrument and a clamp meter is the right one. That boundary is the first thing to settle, because it is decided by the installation rather than by the specification.
A second limit follows from the construction. The instrument reads the current in a circuit it has been inserted into, so it says nothing about how much work the load is doing: a load at a low power factor can carry a large current for very little power. Where consumption or power factor is the question, the instrument for it is a power meter, and a multimeter reading will not answer it.
Every value below is taken from source documentation. Where a parameter is not stated in the available material it is marked as information required rather than estimated.