Flow Measurement · Electromagnetic Flow Meters

Intelligent Electromagnetic Flow Meter

A direct-display electromagnetic flow meter for conductive liquids, from DN10 to DN2000, with the liner and electrode selected against the medium and its temperature.

LDG-SUP ·

Key specifications

Model
LDG-SUP
Media
Conductive liquids at ≥50 µS/cm, including water, wastewater, coolant, paper stock and acid or alkali solutions; ≥2 µS/cm for the liquid-cooling form and ≥5 µS/cm for the slurry form
Nominal size
DN10 to DN2000 standard, DN6 to DN65 micro-bore, DN300 to DN2200 to order
Accuracy
±0.5 % of reading
Range ratio
10:1
Nominal pressure
1.6 MPa up to DN250, 1.0 MPa to DN1000, 0.6 MPa to DN2000
Liner
Neoprene, polyurethane, PTFE, PFA or F46, chosen against the medium and its temperature
Electrode
316L stainless steel as standard, with corrosion-resistant alloy, titanium, tantalum and platinum-iridium options
Display
Instantaneous and total flow together on an integral display
Remote reading
An optional wireless module for reading the meter on a cloud platform

An electromagnetic flow meter is the instrument that measures a dirty liquid properly. There is nothing in the bore but the liquid itself, so nothing obstructs the flow and nothing catches fibres, grit or solids; the meter reads a voltage generated across the moving medium rather than the position of a moving part. That is why wastewater, slurry, paper stock and chemical dosing lines are its natural duties, and why it holds its accuracy on streams that would blind or jam other types.

The price of that construction is a precondition. The liquid has to conduct, and the pipe has to run full. Where either fails, no amount of instrument quality helps, and the answer is a different technology rather than a better magmeter.

What the meter does and what it needs

The measuring section is a lined length of pipe with coils around it and two electrodes through the liner into contact with the liquid. The coils generate a magnetic field across the bore; the moving conductive liquid generates a small voltage across that field; the electrodes pick the voltage up. Because the voltage is proportional to velocity for a given bore and field, the meter converts it into a volume per unit time.

Two consequences follow directly. A liquid below the conductivity the sensor needs cannot generate a usable signal, which is why deionised water, pure solvents and most hydrocarbon products are out of scope rather than merely difficult - and why this meter is offered with low-conductivity variants, at ≥2 µS/cm for cooling circuits and ≥5 µS/cm for slurry, when the standard threshold of ≥50 µS/cm is too high for the duty. And the electromagnetic circuit includes the pipe and the earth, so the grounding electrode the material describes is part of the measurement rather than an installation nicety: a meter without a solid earth reference holds a drifting zero, and no calibration will correct it.

Choosing the liner and the electrode

These two parts are where the medium compatibility of the whole instrument is decided, and they are best settled as a pair. The liner is what prevents the induced signal from short-circuiting through the metal body, and it is also the surface the medium touches for the life of the meter. The electrode is the one point where a metal is deliberately in contact with the liquid.

Two different failure modes have to be answered at once. Chemical attack decides the family: a fluoropolymer for aggressive acids and alkalis, a rubber for water and mildly aggressive service. Abrasion decides within the family: an abrasive slurry wears through a fluoropolymer at a rate no chemical argument anticipates, and the material offers rubber liners for exactly that reason. Temperature then narrows the choice again, because each liner carries its own medium limit, and the material gives these individually rather than as a single instrument figure - which means the liner, not the meter, sets the maximum temperature of a given order.

The material carries a separate selection table for each, with the corrosion behaviour of each electrode material described against the acid, alkali or salt it is expected to meet. Because the two tables are separate, the combination is worth confirming for the specific medium rather than assembling from two individually reasonable choices.

Reading the meter and getting the data out

The instrument shows instantaneous and total flow together on an integral display, which means a reading taken at the meter carries the shift total with it. For anything beyond local reading, the material describes an optional wireless module rather than a wired output: the meter reports to a cloud platform over a narrowband link, a mobile data terminal or an edge gateway, with multi-device monitoring and data export.

That is worth noting as a scope question rather than a feature, because a wired output is what a plant control system normally expects. Material received in November 2026 for the same range closes that gap: it states a 4-20 mA flow-current output, pulse or frequency output, and upper and lower alarm contacts, with RS485/Modbus on the communication form and a supply input of 220 V AC or 24 V DC. The two descriptions are kept side by side rather than merged, because they differ in detail - the pressure break points and the liner temperature limits are not identical between them - and the interface for a given order should be confirmed against the model actually quoted.

Installation

The material gives a straight run of 10 pipe diameters upstream and 5 downstream, and the reasons are the same as for any velocity-based meter: the profile at the electrodes is part of the measurement. It also gives the mounting positions that keep the pipe full and free of air - on the rising section of a line or the lower part of a horizontal run, never at the highest point of the line, never on a downward vertical - and advises a vent valve downstream where the fall in the line exceeds 5 m. The meter is not to be installed on the suction side of a pump.

The practical reason these rules are stated so firmly is that a magmeter that is badly installed does not fail. It reads, and it reads plausibly, and the error appears as a slow disagreement with a total taken elsewhere rather than as a fault anyone can point at.

Measurement limitations and selection considerations

The first limitation is conductivity, and it should be checked before anything else, because it decides whether the type applies at all. The second is that the pipe must run full: a partly filled line gives a reading based on a wetted area that is not the bore, and the error is largest when the flow is lowest, which is exactly when a plant is most likely to be looking for a leak or a blockage.

The material also leaves several figures unsettled, and they are listed as information required rather than resolved here. The most significant is the output: no wired analogue, pulse or serial signal is stated, and no supply voltage is given, so the electrical interface of an order is not yet determined by the material. The working temperature of -10 to 55 °C is given without saying whether it is the ambient or the medium temperature, and the maximum medium temperature appears only per liner. The dimension table in the material is reproduced with a note that its column meanings were inferred from the drawing. And the accuracy is given as a percentage of reading, which is not the same quantity as an accuracy class and should not be converted into one.

Ordering

The items that fix the answer are the medium, its conductivity and whether that varies; the minimum, normal and maximum flow; the pipe outside diameter, wall thickness and the flange standard it must match; the liner and electrode, or the chemical environment if those are not yet decided; the maximum medium temperature and the line pressure; the pressure rating required; the electrical interface and what will read it; whether the process is cleaned in place, buried or otherwise subject to conditions that change the body; and whether the area is classified as hazardous. A medium list and a pipe detail are enough for a covering quotation, which can then be refined as the liner and electrode are settled. Quantity, destination port and required delivery date complete the enquiry.

Features

  • A liner and an electrode selected as a pair from published tables, so the wetted parts are settled against the medium and its temperature rather than against a single default that suits only water
  • Liner choices that answer abrasion as well as corrosion, so an abrasive slurry can be met with a rubber liner instead of a fluoropolymer that would wear through
  • A grounding electrode described as shielding the measurement from site interference, which is the practical reason a meter of this type holds a stable zero
  • An integral display showing instantaneous and total flow together, so a reading taken at the meter carries the total with it
  • Forms for duties the standard meter does not cover, including low-conductivity cooling circuits, low-conductivity slurry, a unit prepared for environmental reporting and an explosion-proof version
  • An optional wireless module for reading the meter on a cloud platform, covering sites where no cable route exists

Technical specifications

Every value below is taken from source documentation. Where a parameter is not stated in the available material it is marked as information required rather than estimated.

Medium and range
MediaConductive liquids, including clean water, sewage, wastewater, coolant, circulating water, paper stock and acid or alkali solutionsStandard
Conductivity≥50 µS/cm as standard; ≥2 µS/cm for the liquid-cooling form; ≥5 µS/cm for the slurry formStandard
Nominal sizeDN10 to DN2000 standard; DN6 to DN65 micro-bore; DN300 to DN2200 large-bore to orderStandard
Accuracy±0.5 % of readingStandard
Range ratio10:1Standard
Nominal pressure1.6 MPa for DN10 to DN250, 1.0 MPa for DN300 to DN1000, 0.6 MPa for DN1200 to DN2000; other ratings to orderStandard
Working temperatureThe material gives -10 to 55 °C under a general heading without stating whether this is the ambient or the medium temperature; the liner table gives liner-specific medium limits instead, and the two are not reconciledInformation required
Storage temperature-40 to 65 °CStandard
Response timeNot stated in the materialInformation required
Wetted parts
Electrode316L stainless steel as standard; corrosion-resistant nickel alloys, titanium, tantalum and platinum-iridium to order; a tungsten-carbide coating is offered for abrasive mediaStandard
LinerNeoprene, polyurethane, PTFE, PFA and F46Standard
Liner medium temperature limitsNeoprene 80 °C, or 120 °C to special order; polyurethane 70 °C; PTFE 120 °C; F46 120 °CStandard
Body material304 stainless steel; the micro-bore form is given as 304 stainless throughoutStandard
Grounding electrodeFitted, and described in the material as shielding the measurement from site interferenceStandard
Electrode and liner qualified as a pairNot stated; the material presents two separate selection tables rather than a combined matrixInformation required
Electrical and communication
Supply220 V AC or 24 V DC, stated as the transmitter supply input in material received November 2026Standard
DisplayInstantaneous and total flow togetherStandard
Wired output4-20 mA flow-current output, pulse or frequency output, and upper and lower alarm contacts; RS485/Modbus on the communication form (November 2026 material)Standard
Wireless moduleOptional, described as reaching a cloud platform over NB-IoT, a 4G data terminal or an edge gateway, with multi-device monitoring and data exportOptional
Ingress protectionIP65Standard
Explosion-proof form markingEx db ib IIC T6 to T4 Gb as stated for that form in the material, which notes the marking is reproduced as the certificate gives itStandard
Mechanical and installation
Process connectionFlanged as standard; wafer clamping and quick-fit clamping to orderStandard
Straight pipe run10 D upstream and 5 D downstream of the meterStandard
Mounting positionOn the rising section of a line or the lower part of a horizontal run; not at the highest point of the line and not on a downward verticalStandard
Pump positionThe material states the meter is not to be installed on the suction side of a pumpStandard
Vent valveRecommended downstream where the fall in the line exceeds 5 mOptional
WeightNot stated in the materialInformation required
Forms
Integral and separateSensor and transmitter in one housing, or the two separated where the point is hot, vibrating or awkward to reachStandard
Large-bore formDN300 to DN2200, given as PTFE lined and 0.5 % accuracyMade to order
Liquid-cooling formFor low-conductivity media at ≥2 µS/cm, with threaded, clamping or flanged connectionsMade to order
Slurry formGiven the code FMC400, for media at ≥5 µS/cm, with empty-pipe, coil and limit alarmsMade to order
Explosion-proof formDN15 to DN50, PTFE lined, 0.5 % accuracyMade to order
Environmental-reporting formDN15 to DN50, PTFE lined, described as meeting the HJ212 national standard for reporting to an environmental authorityMade to order
Remote-reading formA wireless link for monitoring without a cable route, described for water and heating networksOptional
Micro-bore formDN6 to DN65 in 304 stainless steel, for clean water, wastewater and strong acid or alkali liquidsMade to order

Available models

Selection table
Model Configuration Key ranges Availability
LDG-SUP Intelligent direct-display electromagnetic flow meter, integral or separate, flanged as standard with wafer and quick-fit clamping to order, in 304 stainless steel DN10 to DN2000 standard, DN6 to DN65 micro-bore, DN300 to DN2200 to order; ±0.5 % of reading; range ratio 10:1; 1.6 MPa up to DN250 The base model. Most of the other forms are described in the material as variants of this one rather than as separate codes
FMC400 Slurry form with empty-pipe, coil and limit alarms, for low-conductivity abrasive media Conductivity ≥5 µS/cm; described for slurry, paper stock, wood pulp and sludge

Customization

  • Electrode material, from 316L stainless steel through corrosion-resistant alloys to titanium, tantalum and platinum-iridium, with a tungsten-carbide coating for abrasive duties
  • Liner material, from neoprene and polyurethane through PTFE and PFA to F46, each with its own chemical band and its own medium temperature limit
  • Process connection, with flanged as standard and wafer clamping and quick-fit clamping to order
  • Large-bore construction, given in the material to DN2200
  • Forms for particular duties, including the liquid-cooling form for low-conductivity circuits, the slurry form with alarms, an explosion-proof version and a version prepared for environmental reporting
  • Remote reading through the optional wireless module

Certification and compliance

Certification documents not yet supplied

Certifications are only published once a certificate copy can be produced, so this section is deliberately empty rather than populated with assumed approvals. Tell us which approvals your application requires and we will confirm what is available for this instrument.

Parameters still to be confirmed

The following are required for a complete specification but are not stated in the documentation supplied to us. They are listed rather than estimated:

  • Whether the working temperature figure of -10 to 55 °C refers to the ambient or to the medium
  • The maximum medium temperature of the instrument itself, which the material gives only per liner rather than as an instrument limit
  • The response time
  • The accuracy expressed as a class or as a limit of error, since the material gives it as a percentage of reading and the two are not the same quantity
  • An electrode and liner combination qualified together for the media this meter is likely to meet, since the material presents them as two separate tables
  • The weight, and the pressure test standard applied to the larger bores
  • The certificate and marking that will accompany the explosion-proof form, and the scope it covers
  • What the environmental-reporting form supplies beyond the meter itself
  • The wireless module specification, including the platform it reports to and how the data plan is arranged
  • Whether the micro-bore and large-bore forms share the base model code or carry their own
  • Warranty period and the terms that apply
  • An English-language datasheet, and a single table covering the forms together

Frequently asked questions

What has to be confirmed before a magmeter can be quoted?

The liquid and its conductivity, because the type produces nothing measurable below the conductivity the sensor needs and that single fact rules it in or out. Then the liner and electrode, which are settled together against the medium and its temperature and are what decide whether the meter survives at all. Then the minimum, normal and maximum flow, since the bore is chosen so the duty sits inside the working band, and the pipe size alone is only a starting point. Then the pressure rating and the process connection, and the flange standard the new meter has to match. A medium list with the flow range and the pipe detail is enough for a covering quotation.

What output and supply does this meter use?

The original sheet stated neither, and described only the display and an optional wireless module. Material received in November 2026 for the same range states a 4-20 mA flow-current output, pulse or frequency output, upper and lower alarm contacts, RS485/Modbus on the communication form, and a supply input of 220 V AC or 24 V DC. The two descriptions are not identical in every particular, so both are recorded and the interface should be confirmed against the model actually quoted rather than assumed from either sheet alone.

Why does the liner matter as much as the electrode?

Because the liner is what keeps the induced signal from short-circuiting through the metal pipe, and it is also the part in contact with the medium. Wear is the other half of the question: a rubber liner resists an abrasive slurry that would wear a fluoropolymer through, while a fluoropolymer survives aggressive chemicals that would attack rubber. The material carries two separate selection tables for exactly this reason, and the two are best settled together rather than one at a time - a liner and an electrode can each be individually suitable for a medium and still fail as a combination.

How is the meter installed without upsetting the reading?

Three things decide it. A straight run of 10 pipe diameters upstream and 5 downstream, because the meter reads the profile across its electrodes and swirl from an elbow or a partly open valve appears as an error that calibration cannot remove. A mounting position on the rising section or the lower part of a horizontal line, never at the highest point of the line where air collects and never on a downward vertical where the pipe may not run full. And a solid earth reference, which the material provides through a grounding electrode, because the electromagnetic circuit includes the pipe and a poor earth shows up as a drifting zero rather than as an obvious fault.

Related products

Other models in the same range

Wall-mounted flow meter in a light grey enclosure with a green backlit display showing zero flow, a printed label reading ULTRASONIC FLOWMETER above it, a numeric keypad marked 0 to 9 with menu and enter keys below, five cable glands along the bottom edge, and a pair of clamp-on transducers in blue and white housings lying beside it

SIN-1158S (3 models) · Ultrasonic Flow Meters

Clamp-On Ultrasonic Flow Meter

Clamp-on ultrasonic flow meter for heating, building and process water, supplied as a wall-mounted, handheld or fixed host with clamp-on and insertion transducers.

Model
SIN-1158S / SIN-2100H / SIN-FSC400
Mounting
Clamp-on transducers on the outside of the pipe, or an insertion transducer through the wall
Accuracy
±1 % of full scale, as stated in the material
Pipe range
DN20 to DN1200 according to host and transducer; DN80 to DN6000 with an insertion probe
Flow meter head with a blue casing, a dark liquid-crystal display and three buttons beneath it, carried on a stainless steel stem above a flanged pipe body with a large flange at each end, a separate armoured temperature probe on a flexible conduit beside it, and a small red flow-direction label on the body

LUGB-SUP (2 models) · Vortex Flow Meters

Vortex Steam Flow Meter

A vortex flow meter for steam, gas and liquid lines, supplied in an integral and a conventional form with pulse, current or serial output and optional temperature and pressure compensation.

Model
LUGB-SUP / LUGB-SUP-C
Media
Liquid, gas and steam, including saturated and superheated steam
Nominal size
DN15 to DN300 as a full-bore body; DN300 to DN1000 as an insertion type
Accuracy
1.0 % to 2.5 % of reading, according to medium, size and compensation

Request a quotation for the LDG-SUP

Send the configuration you need and we will confirm availability, lead time and terms. Minimum order quantity is 1 pc.

Request for quotation

Request a quotation - LDG-SUP

Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.

The more of this you can give us, the fewer exchanges are needed before we can quote.
No file chosen
Datasheet, drawing, BOM or photograph. One file, up to 10 MB (PDF, Office, image or ZIP).

By submitting this form you agree that we may contact you about this enquiry. We do not sell or share enquiry data. See our privacy policy.

Items held in stock are dispatched within 48 hours of order confirmation. Customized specifications are produced to order and typically ship within 2 to 10 days. Transit time then depends on the shipping method and destination.

Request a Quote WhatsApp