Flow Measurement · Vortex Flow Meters

Vortex Steam Flow Meter

A vortex flow meter for steam, gas and liquid lines, supplied in an integral and a conventional form with pulse, current or serial output and optional temperature and pressure compensation.

LUGB-SUP (2 models) ·

Key specifications

Model
LUGB-SUP / LUGB-SUP-C
Media
Liquid, gas and steam, including saturated and superheated steam
Nominal size
DN15 to DN300 as a full-bore body; DN300 to DN1000 as an insertion type
Accuracy
1.0 % to 2.5 % of reading, according to medium, size and compensation
Medium temperature
Up to 300 °C on the integral form and 330 °C on the conventional form
Range ratio
Given as 8:1 at the stated reference densities, 1:6 to 1:25 by size, and up to 1:30 on the flagship form
Output
Pulse, 4-20 mA and RS-485, with HART optional
Supply
24 V DC, or an internal 3.6 V lithium battery
Display
LCD showing instantaneous and total flow together, in m³/h, L/min, Nm³/h, NL/min or t/h
Compensation
Standard, temperature only, pressure only, or both, integral or separate

A vortex meter answers the steam question. Where a plant wants to know how much energy it is buying, moving or losing, the medium is usually steam or compressed air, and the instruments that measure conductive liquids are of no use on either. The vortex meter measures them without a moving part, and that combination is the reason it appears at the top of almost every boiler house energy account.

What it asks for in return is a stream it can count. The instrument reads a rhythm rather than a level or a pressure, and a rhythm needs regular shedding, which is why the conditions around the body matter as much as the body itself.

How the measurement is made

A bluff body is fixed across the bore. As steam passes it, vortices are shed alternately from the two sides, and each shed vortex takes a small pressure pulse from the edge behind it. A sensor in the body detects that alternation and the electronics count it. Across the band the body is designed for, the counting frequency is proportional to velocity, so a known bore converts it into a volume per hour.

The signal being a frequency is what makes the type durable in this duty. A frequency does not drift the way an analogue span drifts, and it does not need a moving element that steam and heat will eventually seize. What it does need is that the medium stay in one phase while it is inside the meter. Droplets in wet steam disturb the shedding, and a gas that condenses in the body does the same, which is why the material is explicit that the device is not offered for two-phase flow and why a dry-steam separator upstream is often part of the answer rather than a separate project.

What the body is asked to survive

Two independent sets of conditions act on the instrument, and they are usually stated separately because they are survived by different parts. The medium conditions - temperature, pressure, whether the steam is saturated or superheated - are met by the body, the sensor and the sealing. The ambient conditions - vibration, weather, whether the line is insulated and how hot the space around the head becomes - are met by the housing and, over years, by the electronics.

The material behind this page describes the flagship form as having a thicker body for lines carrying high-frequency vibration and a sensor assembly on a square-section support, which is an answer to the second set of conditions rather than the first. That is worth noting, because vibration at the shedding frequency is indistinguishable from flow: a meter that is vibrating is not merely inaccurate, it is reading something that is not there.

Volumetric and compensated readings

What a vortex meter produces is a volume, and for steam and gas a volume is rarely the figure the buyer needs. A cubic metre of steam at one pressure contains a different amount of energy from a cubic metre at another, so a total taken without compensation changes whenever the boiler load or the line pressure changes, even when the same energy has been delivered.

Compensation corrects for that by measuring temperature and pressure and converting the volume to a mass or to a standard volume. It can be arranged integrally, with the sensing at the meter, or separately, with a flow computer taking an external temperature sensor and pressure transmitter. The material describes the separate arrangement as the one for superheated steam, high-temperature lines and overhead pipework, which is a practical distinction: the sensing points have to be reachable and correctly placed, and on a hot overhead line that is easier to arrange away from the meter.

Whether compensation is needed is a question about the account being kept, not about the meter. A line metered only to see whether it is running needs no compensation; a line metered to bill energy does.

Installation and the straight run

The body has to see a settled, swirl-free profile, and the material gives 10 DN upstream and 5 DN downstream as the normal requirement. Those figures belong to the instrument, not to the site, so where the available space is shorter the layout has to be settled before the meter is ordered rather than after. A disturbance close to the body - an elbow, a partly open valve, a reducer, a thermowell - is read as a change in flow and appears as an error that no calibration can remove.

Two further points from the material are worth carrying into the installation. Welding should be done before the meter is fitted, because welding current passing through the instrument can damage its electronics even when it is not powered. And the mounting attitude is part of the duty: a body set above a hot line ages faster than one set to the side, so steam and high-temperature gas installations are advised to have the body support angled away from vertical.

Measurement limitations and selection considerations

The material states plainly that it is not offered for wet steam or two-phase flow, and that is the first limitation to check rather than the last. The second is velocity: below a certain figure the shedding stops being regular and the low end of the range is set by the physics of the body rather than by an electronic limit, which is why a pipe oversized for its flow makes a poor vortex installation.

The material also leaves three figures unsettled, and they are the ones a buyer normally compares first. The range ratio is given in three different ways - 8:1 at the stated reference densities, 1:6 to 1:25 for the conventional form, and up to 1:30 in the feature list - and the material itself notes that the ratio changes with medium density, so none of the three can be applied to an arbitrary medium without checking. The medium temperature is given under two schemes that overlap. And the accuracy is expressed both as a class and as a percentage of reading, which are different quantities and should not be converted into each other. All three are listed below as information required rather than resolved here.

Ordering

The items that fix the answer are the medium and whether it is steam, gas or liquid; whether the steam is dry; the minimum, normal and maximum flow; the medium temperature and pressure and whether they vary; the pipe outside diameter with the wall thickness and the flange standard; whether a compensated mass or standard volume is required; the outputs and what will read them; whether a supply exists at the point of installation; and the straight run available upstream and downstream. A line description with a sketch of the proposed point is enough to issue a covering quotation, which can then be refined as the siting is agreed. Quantity, destination port and required delivery date complete the enquiry.

Features

  • A sensor assembly the material describes as a third-generation reinforced design on a square-section support, presented as the answer to the vibration and high temperature that shorten the life of a probe in a steam line
  • Digital filtering with five selectable settings, described by the material as the way the meter copes with a pulsating or noisy flow rather than a fixed filter that cannot be adjusted on site
  • An LCD that shows instantaneous and total flow together, so a reading taken at the meter carries the total with it and no second instrument is needed to close a shift or a day
  • Pulse, 4-20 mA and RS-485 outputs on the same instrument, so one meter can be counted, indicated locally and read by a control system at the same time
  • Optional temperature and pressure compensation, integral or separate, so a steam or gas duty can be totalised as a mass or a standard volume rather than as a volume at the conditions of the moment
  • A choice of 24 V DC or an internal battery, so a metering point with no supply can still be fitted, and a battery is stated to last more than two years

Technical specifications

Every value below is taken from source documentation. Where a parameter is not stated in the available material it is marked as information required rather than estimated.

Medium and range
MediaLiquid, gas, saturated steam and superheated steam; steam, gas and liquid are separate order codes rather than a settingStandard
Nominal sizeDN15 to DN300 as a full-bore body; DN300 to DN1000 as an insertion typeStandard
Medium temperature-40 to 260 °C and -40 to 300 °C on the integral form, and -40 to 330 °C on the conventional form; the material also gives a mid-temperature band of -40 to 250 °C and a high-temperature band of -40 to 330 °C, and the two sets overlap without being reconciledInformation required
Ambient temperature-20 to 55 °C on the conventional formStandard
Range ratio8:1 at a gas density of 1.2 kg/m³ and a liquid density of 1000 kg/m³ in the parameter table; 1:6 to 1:25 for the conventional form; up to 1:30 in the feature list; the material states that the ratio changes with medium density, and does not settle which of the three figures applies to a given orderInformation required
Accuracy, gas without compensation1.5 % for DN15 to DN25, 1.0 % for DN32 to DN200, 1.5 % for DN250 to DN300Standard
Accuracy, liquid without compensation1.0 % for DN15 to DN300Standard
Accuracy, temperature and pressure compensated1.5 % for DN25 to DN300Standard
Accuracy, conventional body±1.5 % of reading, and ±2.5 % of reading for the insertion typeStandard
Pressure ratingNot stated in the materialInformation required
Electrical
Supply24 V DC ±5 %, or a 3.6 V DC lithium battery stated to last more than two yearsStandard
Pulse outputLow level ≤1 V, high level ≥6 VStandard
Current output4-20 mA, load resistance ≤300 ΩStandard
CommunicationRS-485, with HART optionalStandard
DisplayLCD showing instantaneous and total flow togetherStandard
Display unitsm³/h, L/min, Nm³/h, NL/min and t/hStandard
Electrical connectionM20 × 1.5 internal threadStandard
Filter settingsFive selectable digital filter settingsStandard
Mechanical
Body materialStainless steel; the conventional form is given as 304 with a die-cast aluminium totalizer housingStandard
Process connectionClamped or flanged, with the flange standard and body material chosen by order codeStandard
Ingress protectionIP65 on the conventional formStandard
Sensor and bluff body materialNot stated in the materialInformation required
Insertion formAvailable for DN300 to DN1000 where the line cannot be openedStandard
Weight and outline dimensions of the insertion formNot stated in the materialInformation required
Compensation and installation
Compensation arrangementsIntegral, with temperature and pressure sensing at the meter, or separate, with the flow computer taking an external temperature sensor and pressure transmitterStandard
Compensation order codesStandard without compensation, temperature only, pressure only, or bothStandard
Straight pipe runThe material states 10 DN upstream and 5 DN downstream of the meter as the normal requirementStandard
Mounting attitudeHorizontal, vertical or inclined; steam and high-temperature gas lines are advised to have the body support set about 45° from verticalStandard
Flange standardGiven as GB/T 9119 for the flanged connection in the order codeStandard
2026-11 supply batch
ScopeAdditional forms supplied in November 2026 for this product type. Figures below are from that batch; where they differ from the rows above, both are recorded rather than merged.Standard
Nominal sizeDN15, DN25, DN32, DN40 and DN50 appear across the batch, with flanged or threaded connectionStandard
Accuracy1.0 class and 1.5 class versionsStandard
OutputRS-485/Modbus, HART and 4-20 mAStandard
Supply24 V DC, with battery-powered versions for sites without a supplyStandard
Medium temperature-45 to 100 C, -45 to 250 C, -45 to 330 C or -45 to 450 C depending on the versionStandard
Body materialAluminium alloy, 304 stainless and 316L stainlessStandard
Ingress protectionIP65, with IP67 versionsStandard

Available models

Selection table
Model Configuration Key ranges Availability
LUGB-SUP Integral flagship form with a thicker body for lines carrying high-frequency vibration, clamped or flanged, with temperature and pressure compensation available DN25 to DN300 for the compensated form; medium temperature to 260 °C or 300 °C; 4-20 mA output The material gives three output codes for this form, one of which pairs 24 V DC with a battery
LUGB-SUP-C Conventional form, full bore or insertion, IP65, with a die-cast aluminium totalizer housing DN15 to DN300 full bore, DN300 to DN1000 insertion; -40 to 330 °C; ±1.5 % of reading, ±2.5 % of reading for the insertion type The insertion type is the answer where the line cannot be opened

Customization

  • Temperature and pressure compensation, integral with the meter or arranged separately with an external sensor and transmitter, which is what turns a volumetric reading into a mass or standard-volume figure
  • Medium-temperature variants, since the material offers an integral band to 260 °C or 300 °C, a conventional band to 330 °C and a mid-temperature and high-temperature split
  • Communication and remote-reading options, including RS-485 and HART, and a form the material describes for sending the reading over a mobile network with alarm notification
  • Flange standard, flange material and body material, including carbon steel and stainless steel process connections
  • Output configurations by order code, including pulse without a display

Certification and compliance

Certification documents not yet supplied

Certifications are only published once a certificate copy can be produced, so this section is deliberately empty rather than populated with assumed approvals. Tell us which approvals your application requires and we will confirm what is available for this instrument.

Parameters still to be confirmed

The following are required for a complete specification but are not stated in the documentation supplied to us. They are listed rather than estimated:

  • The pressure rating of the body, which the material does not state for either form
  • The material of the sensor, the bluff body and the bluff body support, given only as a reinforced third-generation design
  • Whether an explosion-proof form is available and what marking it would carry, since the material says only that hazardous-area duties have to be confirmed before purchase
  • The three range-ratio figures the material gives, 8:1, 1:6 to 1:25 and up to 1:30, so that one can be published against a stated medium
  • The two medium-temperature schemes the material gives, which overlap without being reconciled, so that the allowable band is settled per order code
  • Whether the accuracy figures are quoted as an accuracy class or as a limit of error, since the material uses both forms of expression and they are not the same thing
  • The pressure drop across the body at a stated flow, which the material does not give
  • The battery life expressed against a duty cycle, since more than two years is given without a definition of the load
  • The output resolution and the totalizer capacity
  • The HART implementation and whether the RS-485 port speaks Modbus
  • The weight and the outline dimensions of the insertion form
  • Warranty period and the terms that apply
  • An English-language datasheet, and a single table covering both forms

Frequently asked questions

What has to be decided before a steam meter can be quoted?

Four things, and they are all decided before the instrument is chosen. Whether the steam is dry and single phase, because a vortex body needs a clean stream and droplets disturb the shedding. The flow range, because the bore is chosen so the normal duty sits inside the working band rather than at the bottom of it. The medium temperature and pressure, because together they decide the body rating and whether compensation has to be fitted for the figure to mean anything. And the pipe size with the straight run available in front of it, because the profile at the body is part of the measurement. A line description and a sketch of the proposed point are enough to issue a covering quotation.

Is temperature and pressure compensation an extra or part of the meter?

It can be either, and the distinction matters for the scope. In the integral arrangement the temperature and pressure sensing is at the meter itself and the compensation is internal, which suits saturated steam and low-pressure work. In the separate arrangement a flow computer takes an external temperature sensor and pressure transmitter, which is the usual choice where the steam is superheated, where the pipe is overhead or hot, or where the sensing points have to sit at a distance from the meter. What compensation changes is the figure: an uncompensated reading is a volume at the conditions of the moment, and a compensated one is a mass or a standard volume.

What does the range ratio figure actually decide?

It sets the span over which the meter can be trusted, and therefore whether a bore can cover both the low and the high end of a duty. The material gives more than one figure for it, which is itself a reason to settle the requirement from the flow range rather than from the ratio: the number changes with the density of the medium, so a ratio quoted for one gas is not the ratio the meter will have on another. Where the duty runs from a small night load to a large day load, the low end is what constrains the choice, and the answer is often to size on the minimum rather than on the maximum.

Why does the material advise against welding with the meter in place?

Because the meter body is part of the electrical path. Welding current passing through the instrument can damage the electronics even when the meter is not powered, and the material therefore advises welding the flanges first and fitting the meter afterwards. The related point it makes is about the straight run and the mounting attitude: a body set above a hot line ages faster than one set to the side, which is why steam and high-temperature gas installations are advised to have the body support at an angle rather than vertical.

Related products

Other models in the same range

White-bodied flow meter with a red transmitter housing, an integral display reading 13.625 m³/h and a running total, three buttons marked ESC, ENT and a direction key below the display, two cable glands on the side, and a red flow-direction arrow moulded on the white measuring section between two flanges

LDG-SUP · Electromagnetic Flow Meters

Intelligent Electromagnetic Flow Meter

A direct-display electromagnetic flow meter for conductive liquids, from DN10 to DN2000, with the liner and electrode selected against the medium and its temperature.

Model
LDG-SUP
Media
Conductive liquids at ≥50 µS/cm, including water, wastewater, coolant, paper stock and acid or alkali solutions; ≥2 µS/cm for the liquid-cooling form and ≥5 µS/cm for the slurry form
Nominal size
DN10 to DN2000 standard, DN6 to DN65 micro-bore, DN300 to DN2200 to order
Accuracy
±0.5 % of reading
Wall-mounted flow meter in a light grey enclosure with a green backlit display showing zero flow, a printed label reading ULTRASONIC FLOWMETER above it, a numeric keypad marked 0 to 9 with menu and enter keys below, five cable glands along the bottom edge, and a pair of clamp-on transducers in blue and white housings lying beside it

SIN-1158S (3 models) · Ultrasonic Flow Meters

Clamp-On Ultrasonic Flow Meter

Clamp-on ultrasonic flow meter for heating, building and process water, supplied as a wall-mounted, handheld or fixed host with clamp-on and insertion transducers.

Model
SIN-1158S / SIN-2100H / SIN-FSC400
Mounting
Clamp-on transducers on the outside of the pipe, or an insertion transducer through the wall
Accuracy
±1 % of full scale, as stated in the material
Pipe range
DN20 to DN1200 according to host and transducer; DN80 to DN6000 with an insertion probe

Request a quotation for the LUGB-SUP

Send the configuration you need and we will confirm availability, lead time and terms. Minimum order quantity is 1 pc.

Request for quotation

Request a quotation - LUGB-SUP

Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.

The more of this you can give us, the fewer exchanges are needed before we can quote.
No file chosen
Datasheet, drawing, BOM or photograph. One file, up to 10 MB (PDF, Office, image or ZIP).

By submitting this form you agree that we may contact you about this enquiry. We do not sell or share enquiry data. See our privacy policy.

Items held in stock are dispatched within 48 hours of order confirmation. Customized specifications are produced to order and typically ship within 2 to 10 days. Transit time then depends on the shipping method and destination.

Request a Quote WhatsApp