Flow Measurement · Ultrasonic Flow Meters

Clamp-On Ultrasonic Flow Meter

Clamp-on ultrasonic flow meter for heating, building and process water, supplied as a wall-mounted, handheld or fixed host with clamp-on and insertion transducers.

SIN-1158S (3 models) ·

Key specifications

Model
SIN-1158S / SIN-2100H / SIN-FSC400
Mounting
Clamp-on transducers on the outside of the pipe, or an insertion transducer through the wall
Accuracy
±1 % of full scale, as stated in the material
Pipe range
DN20 to DN1200 according to host and transducer; DN80 to DN6000 with an insertion probe
Medium temperature
-30 to 90 °C as the common band, with a higher figure given per host that the material does not reconcile
Function
Flow measurement with cumulative total; heat and cooling measurement described as part of the host
Ingress protection
IP65 as stated in the material
Output signal
Not stated in the material
Supply
Not stated in the material
Forms
Wall-mounted, handheld and a fixed host sharing the same transducer range

A clamp-on flow meter exists because of a practical problem: the pipe that most needs measuring is usually the one that cannot be cut. A large existing main, a building’s heating riser, a line feeding a process that runs continuously - each is a candidate for a flow measurement and none can be taken out of service to install one. The ultrasonic clamp-on meter answers that by putting the transducers on the outside of the pipe and measuring through the wall.

The trade for that convenience is a measurement whose quality depends on the pipe itself, which is why the pipe detail matters more here than on any other flow technology.

What the instrument consists of

Two transducers and a host. The host is the instrument: it drives the transducers, times the pulses and computes the flow, and it is the part that changes between the forms in this range. A wall-mounted host lives at one point and keeps a running total. A handheld host is carried between pipes and answers a measurement question without an installation at all. A fixed host shares the same transducers for a permanent point of record.

The transducers divide by how they reach the liquid. Clamp-on types are strapped to the outside of the pipe, and the range in the material covers small, medium and large transducers each spanning a band of bore sizes, plus a bracket-mounted type for confined spaces and small pipes. Insertion types pass through the wall into the flow, which the material describes as installable without stopping production up to a stated wall thickness and to a larger thickness to special order.

Measuring through the pipe wall

The measurement compares the time an ultrasonic pulse takes to cross the pipe with the flow and against it. The difference is small and is calculated from the path length, so the meter has to be told the pipe geometry - and that is where clamp-on measurement parts company with a wetted instrument. The signal crosses the wall twice and depends on the coupling between transducer and wall, so the material the pipe is made of, its thickness, the condition of its outer surface and the quality of the coupling are all part of the measurement rather than accessories to it.

The insertion form removes that dependency by putting the transducer into the liquid, which is why the material offers it up to a large bore where the acoustic path across a thick wall would otherwise be marginal. What it costs is an opening in the pipe.

Installing and using it

Clamp-on transducers are fixed to the outside of the pipe, so the line is not opened and no hole is drilled. Insertion transducers need a shutdown except where the wall is within the stated limit and the fitting is made under pressure. Bracket mounting is offered for small bores and confined spaces, and the material describes it for long-term fixed monitoring.

Because the instrument reads along a path rather than at a point, a straight run is needed upstream and downstream of the measuring position, and the material behind this page does not state a figure for it. That is a question for the enquiry rather than something to be inferred from another technology: the requirement follows from the transducer arrangement and the pipe, and it should be confirmed before the mounting point is fixed.

The forms and what each is for

The wall-mounted host is the one for a permanent point of record, and it is the form that takes the insertion transducer where the pipe cannot be measured from outside. The handheld host carries the same clamp-on transducers and is described for inspection and temporary measurement, which makes it the instrument bought when the duty is not yet confirmed. The fixed host is supplied with the medium transducer for the common range of pipe sizes, and a kit form is offered with a wall-mounted host and a transducer together.

Measurement limitations and selection considerations

The material behind this page is a range summary, and the gaps in it are significant enough to be listed rather than glossed over. It gives no flow velocity range, no repeatability, no output signal, no supply voltage and no communication interface. It states an accuracy of ±1 % of full scale, which is a different basis from a percentage of reading and is not comparable with one. And it describes heat and cooling measurement as part of the host while not listing the matched temperature sensors that such a measurement requires.

The maximum temperature is given in a way that leaves the answer open: a common band of -30 to 90 °C, with a higher figure of 130 °C against one host and 160 °C against another, and no statement of the conditions under which the higher figure applies. Until that is settled, the conservative band is the one to design to.

The other limitation belongs to the technology rather than to this range. Clamp-on measurement needs a pipe that will carry the signal and a pipe whose wall thickness is known, so a heavily corroded, badly coated, concrete or unknown lined pipe may not be measurable from outside at all. That is not a shortcoming of the instrument; it is the geometry refusing to be measured, and the insertion form is the answer where it applies.

Ordering

The items that fix the answer are the pipe material, outside diameter and wall thickness, and whether the pipe is lined; whether the line can be taken out of service, and for how long; the medium and its normal and maximum temperature; the minimum, normal and maximum flow; whether a flow total, a rate, or heat as well as flow is required; whether the installation is permanent or a survey; the output required and what will read it; whether a supply exists at the point of installation; and the straight run available. A pipe detail and a description of what the reading is for are enough to issue a covering quotation. Quantity, destination port and required delivery date complete the enquiry.

Features

  • Transducers fixed to the outside of the pipe, so a flow measurement can be added to a line that cannot be taken out of service and does not have to be cut
  • An insertion form for large pipes and thick walls, described as installable without stopping production up to a stated wall thickness
  • A handheld host carrying the same transducer range as the fixed units, so an unknown duty can be measured on site before an instrument is bought for it
  • A host that records cumulative flow, so a reading carries a total rather than only a rate of the moment
  • Heat and cooling measurement described as part of the host, which is what makes the instrument an energy meter as well as a flow meter
  • Ingress protection stated as IP65 across the range

Technical specifications

Every value below is taken from source documentation. Where a parameter is not stated in the available material it is marked as information required rather than estimated.

Medium and range
MediaLiquids; the material describes heating water, building water, pure water and air-conditioning circulating waterStandard
Accuracy±1 % of full scaleStandard
Pipe range, clamp-onWith the wall-mounted host, DN32 to DN100 with the small transducer, DN50 to DN700 with the medium transducer and DN300 to DN1200 with the large one; DN20 to DN100 with a bracket transducerStandard
Pipe range, insertionDN80 to DN6000 with an insertion probeStandard
Medium temperature-30 to 90 °C as the common band; the material gives 130 °C for one host and 160 °C for another alongside that band, without stating the conditions under which the higher figure appliesInformation required
Flow velocity rangeNot stated in the materialInformation required
RepeatabilityNot stated in the materialInformation required
Straight pipe runNot stated in the materialInformation required
Installation
Clamp-onTransducers fixed to the outside of the pipe; nothing is cut and no hole is drilled, so the line does not have to be taken out of serviceStandard
InsertionA transducer through the pipe wall, described as installable without stopping production on pipes with a wall up to 20 mm, and to 70 mm to special orderStandard
Bracket mountingA small bracket-mounted transducer, described for confined spaces, small bores and long-term fixed monitoringStandard
Wall thickness limit20 mm for non-shutdown insertion work as standard, 70 mm to special orderStandard
Ingress protectionIP65, stated on the material's promotional page rather than in its specification cardsStandard
Electrical and communication
Output signalNot stated in the materialInformation required
Supply voltageNot stated in the materialInformation required
CommunicationNot stated in the materialInformation required
Display and totalCumulative flow recorded in real timeStandard
Temperature sensors for the heat functionNot listed in the material, although heat and cooling measurement is described as part of the hostInformation required
Host forms
SIN-1158SWall-mounted host, for a fixed point of record, with clamp-on, insertion and bracket transducersStandard
SIN-2100HHandheld host, described for inspection and temporary measurementStandard
SIN-FSC400Fixed host used with the medium clamp-on transducerStandard
Wall-mounted kitA wall-mounted host supplied with a DN50 to DN700 transducerOptional

Available models

Selection table
Model Configuration Key ranges Availability
SIN-1158S Wall-mounted host for a fixed point of record, with clamp-on, insertion and bracket transducers DN32 to DN1200 with clamp-on transducers; DN80 to DN6000 with an insertion probe; -30 to 90 °C with a higher figure of 130 °C given alongside that band The form for a permanent installation, including the insertion variant where the pipe wall is within the stated limit
SIN-2100H Handheld host described for inspection and temporary measurement, with clamp-on transducers DN32 to DN700; -30 to 90 °C with a higher figure of 160 °C given alongside that band The form bought when the duty, the pipe or the flow itself is not yet known
SIN-FSC400 Fixed host used with the medium clamp-on transducer DN50 to DN700; -30 to 90 °C The material does not attach a higher temperature figure to this host

Customization

  • A higher temperature band, since the material gives a figure above the common band for two of the hosts
  • Insertion transducers for a pipe wall thicker than the standard limit
  • Bracket mounting for small bores and confined spaces
  • Heat and cooling measurement, which requires a matched pair of temperature sensors that the material describes as part of the instrument without listing it
  • The choice of host form: fixed wall-mounted, handheld, or a kit with the transducer included

Certification and compliance

Certification documents not yet supplied

Certifications are only published once a certificate copy can be produced, so this section is deliberately empty rather than populated with assumed approvals. Tell us which approvals your application requires and we will confirm what is available for this instrument.

Parameters still to be confirmed

The following are required for a complete specification but are not stated in the documentation supplied to us. They are listed rather than estimated:

  • The flow velocity range, which the material does not state
  • Repeatability, and the full basis of the ±1 % of full scale accuracy figure
  • The output signal and the supply voltage, neither of which appears in the material
  • The communication interface
  • Which higher temperature figure applies to which host and under what conditions, since 130 °C and 160 °C are given alongside a common -30 to 90 °C band
  • The straight pipe run required upstream and downstream, which the material does not give
  • The temperature rating of the transducers themselves, as distinct from the medium band
  • The matched temperature sensor pair that the heat and cooling function requires, which the material describes without listing
  • Whether the handheld host stores measurements, and how they are exported
  • The pipe materials and linings for which clamp-on measurement is supported
  • Whether the insertion transducer is offered with the handheld host
  • Whether the stated wall thickness limit applies to the insertion transducer alone or to the clamp-on forms as well
  • Warranty period and the terms that apply
  • An English-language datasheet and a full specification for each host

Frequently asked questions

What has to be confirmed before a clamp-on meter can be quoted?

The pipe, before the flow. Clamp-on measurement sends sound through the wall twice, so the pipe material, its outside diameter and its wall thickness are part of the measurement geometry, and the transducer has to be able to transmit into the material. State all three, and say whether the pipe is lined. Then whether the line can be shut down at all, because that decides between clamp-on and insertion. Then the medium and its temperature, so a transducer can be found that both fits the pipe and survives the duty. The flow range and the straight run available come after that, and the material behind this page does not state a straight-run requirement at all, so it has to be settled from the installation rather than the datasheet.

Why are several figures missing from this page?

Because the material does not state them. It is a range summary rather than a specification: it gives the pipe ranges, the mounting forms, the accuracy and a temperature band, but no flow velocity range, no repeatability, no output signal, no supply voltage and no communication interface. Those are among the first things a buyer compares, so they are listed as information required rather than filled in from a similar instrument. The material also says as much itself, advising that a full specification be requested before selection.

Is this an energy meter as well as a flow meter?

The host is described as measuring heat and cooling as well as flow, and it is offered under a description that covers both. What an energy measurement additionally requires is a matched pair of temperature sensors installed across the circuit, since heat is flow multiplied by a temperature difference. The material describes the function but does not list those sensors, so whether they are part of the scope or a separate purchase is a question for the enquiry rather than an assumption. The flow measurement itself stands on its own and does not depend on them.

Why is a handheld unit worth buying before a fixed one?

Because the handheld host carries the same transducers as the fixed units and answers the measurement question without an installation. In practice the first thing a site often needs to know is whether a line can be measured from outside at all, what the flow actually is, and whether the pipe detail on the drawing matches the pipe in the ground - and all three are answered by carrying the instrument to the pipe rather than by ordering the instrument for it. Where the duty is then confirmed, the same transducers move to a wall-mounted host for a permanent record.

Related products

Other models in the same range

White-bodied flow meter with a red transmitter housing, an integral display reading 13.625 m³/h and a running total, three buttons marked ESC, ENT and a direction key below the display, two cable glands on the side, and a red flow-direction arrow moulded on the white measuring section between two flanges

LDG-SUP · Electromagnetic Flow Meters

Intelligent Electromagnetic Flow Meter

A direct-display electromagnetic flow meter for conductive liquids, from DN10 to DN2000, with the liner and electrode selected against the medium and its temperature.

Model
LDG-SUP
Media
Conductive liquids at ≥50 µS/cm, including water, wastewater, coolant, paper stock and acid or alkali solutions; ≥2 µS/cm for the liquid-cooling form and ≥5 µS/cm for the slurry form
Nominal size
DN10 to DN2000 standard, DN6 to DN65 micro-bore, DN300 to DN2200 to order
Accuracy
±0.5 % of reading
Flow meter head with a blue casing, a dark liquid-crystal display and three buttons beneath it, carried on a stainless steel stem above a flanged pipe body with a large flange at each end, a separate armoured temperature probe on a flexible conduit beside it, and a small red flow-direction label on the body

LUGB-SUP (2 models) · Vortex Flow Meters

Vortex Steam Flow Meter

A vortex flow meter for steam, gas and liquid lines, supplied in an integral and a conventional form with pulse, current or serial output and optional temperature and pressure compensation.

Model
LUGB-SUP / LUGB-SUP-C
Media
Liquid, gas and steam, including saturated and superheated steam
Nominal size
DN15 to DN300 as a full-bore body; DN300 to DN1000 as an insertion type
Accuracy
1.0 % to 2.5 % of reading, according to medium, size and compensation

Request a quotation for the SIN-1158S

Send the configuration you need and we will confirm availability, lead time and terms. Minimum order quantity is 1 pc.

Request for quotation

Request a quotation - SIN-1158S

Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.

The more of this you can give us, the fewer exchanges are needed before we can quote.
No file chosen
Datasheet, drawing, BOM or photograph. One file, up to 10 MB (PDF, Office, image or ZIP).

By submitting this form you agree that we may contact you about this enquiry. We do not sell or share enquiry data. See our privacy policy.

Items held in stock are dispatched within 48 hours of order confirmation. Customized specifications are produced to order and typically ship within 2 to 10 days. Transit time then depends on the shipping method and destination.

Request a Quote WhatsApp