- Model
- KUT350 / KY880S / KY990S / KY9901PLUS
- Sampling frequency
- 150 MHz / 200 MHz / 320 MHz / 800 MHz respectively
- Scanning range
- 0 to 10000 mm on the KUT350; 0 to 6000 mm on the KY880S; 15 to 10000 mm on the KY990S; up to 15000 mm on the KY9901PLUS
- Sound velocity
- 1000 to 15000 m/s on the KUT350 as the card figure, with 100 to 20000 m/s also printed on the same page; 100 to 15000 m/s and 100 to 20000 m/s on the upper models
- Gain
- 0 to 120 dB on the KUT350, KY990S and KY9901PLUS; 0 to 110 dB on the KY880S
- Sensitivity margin
- 62 dB or better on the KUT350 as the card figure, 65 dB in its detail table, and above 62 dB or 65 dB on the other models
- Inspection channels
- 500 groups across the range
- Storage
- 100 A-scan traces on the KUT350 and KY880S; U-disk storage on the KY990S and KY9901PLUS
- Probe modes
- Single-crystal and dual-crystal working, selectable
- Curve functions
- DAC and AVG on the KUT350; the KY9901PLUS adds surface correction and crack height measurement
An ultrasonic flaw detector is used where the defect of interest is inside the material and no surface method will reach it. Sound is sent into the part, what comes back is timed, and a discontinuity ahead of the back wall announces itself as an earlier echo at an amplitude that says something about its size.
The instrument is only half of that measurement. Which echoes appear, and what they mean, depends on the probe that sent the sound and on the calibration that gives the return an absolute meaning - and both of those are agreed per job rather than bought off a shelf.
What the instrument is
A body with a display, a probe and a calibration. The body generates the pulse, times the return, applies the gain and displays the signal; the probe turns electricity into sound and back; the calibration - reference reflectors of known size, or the probe’s own characteristics - is what converts an amplitude into a figure that can be compared with an acceptance level.
The four models in this range differ along those lines rather than in kind. All four share 500 inspection channel groups, colour displays with a language selection, and USB connection to a PC with the software supplied on a USB flash drive. What separates them is the sampling frequency, which runs from 150 MHz to 800 MHz, the scanning range, and whether traces are stored internally or on a removable disk.
Reading the echoes
The instrument times the interval between the transmitted pulse and each returning echo and converts it to a distance using the sound velocity of the material. That is why the velocity has to be set correctly and why the material’s own inconsistency on the KUT350 velocity range matters: for steel the figure is around 5920 m/s in longitudinal mode, and the same delay becomes a different distance in aluminium or in austenitic stainless steel.
Size is inferred rather than measured. The amplitude of an echo depends on the size of the reflector, on its orientation and on how far away it is, so an amplitude on its own says very little. The instrument draws a reference curve - DAC on this range - by recording echoes from known reflectors at several depths, and every subsequent echo is compared against that curve. What gets reported is therefore an equivalent size at a stated threshold, which is what the acceptance standard is written in terms of.
Probes and why they are not in the datasheet
The material specifies the instruments thoroughly and the probes not at all. The KUT350 packing list names one straight probe and one angle probe without giving frequency, crystal size or angle, and no probe specification appears anywhere else.
That is not a small omission, because the probe decides what can be found. A straight probe sends sound along its axis and finds laminations and defects parallel to the surface; an angle probe refracts the beam into the material and is what weld inspection is built around, since the defects of interest in a weld usually lie at an angle to the surface. Frequency trades penetration against resolution, and crystal size trades beam width against energy. Buying the instrument without settling the probes leaves the actual capability of the set undetermined, so the probes belong in the enquiry alongside the instrument.
The models, and where they differ
The KUT350 is the entry model with a touch screen, 150 MHz sampling and a scanning range to 10000 mm. The KY880S has the shortest scanning range at 6000 mm and is described for the largest share of routine industrial work. The KY990S moves to an upright format with U-disk storage and a wider operating temperature. The KY9901PLUS adds the highest sampling rate, the longest scanning range, the tightest linearity figures, and two functions the others do not have: surface correction and crack height measurement, which is what makes it the model for characterising a defect rather than only locating it.
Measurement limitations and selection considerations
The KUT350 carries four inconsistencies that the material states plainly, and all four are carried here rather than resolved. Sound velocity appears as three different ranges across the card and the detail table on the same page. Vertical linearity is given as 2 % on the card and 3 % in the table. The overall dimensions differ by a millimetre. And the minimum display figure of 15 mm in steel sits against a stated 3 mm thin-part capability, with no reconciliation of the two.
The material also carries its own disclaimers - the detail table states that its parameters are for reference only, and the packing list states that the contents may be adjusted. Those are read as instructions and the affected figures are put into information required rather than treated as specification.
The limitations that belong to the method are worth stating too. Sound has to enter the material, so the surface has to be smooth enough and a couplant has to bridge the gap. The beam has a width and a near field, so a defect smaller than the beam is sized by the beam, and a defect very close to the surface sits where the beam has not yet formed. Coarse-grained and austenitic material scatters the beam and raises the noise floor. All of these shape what can be claimed for a given job, and all of them are agreed in the inspection procedure rather than discovered at the instrument.
Ordering
The items that fix the answer are the material and grade; the defect being looked for and where in the section it lies; the section thickness range and a drawing of the joint; the acceptance standard and the level of acceptance; the surface condition at the time of inspection; whether stored traces and a written report are required, which decides between the models with removable storage and the ones without; and the probes, which are not specified in the material and have to be agreed separately, including the angles the standard calls for. If the standard is not yet fixed, send the joint drawing and the working conditions - a quotation can be issued against those and adjusted once the acceptance criteria are settled. Quantity, destination port and required delivery date complete the enquiry.
Every value below is taken from source documentation. Where a parameter is not stated in the available material it is marked as information required rather than estimated.