Portable Gas Detector

Hand-held multi-gas and single-gas detectors with audible, visual and vibrating alarms, covering the four-gas confined space combination as standard and a long list of single gases to order.

BH-4 (2 models) ·

Key specifications

Range
The BH-4 multi-gas instrument and the BH-90 single-gas instrument
Channels
Four on the BH-4, covering combustible gas, oxygen, hydrogen sulphide and carbon monoxide; one on BH-90
Display error
≤±5 %FS
Response time
T90 < 60 s
Alarm
Audible, visual and vibrating, all three at once
Alarm records
4000 events stored on the instrument
Operating conditions
-10 to 50 °C, below 95 %RH without condensation
Battery
1800 mAh rechargeable lithium on the BH-4; 1500 mAh on BH-90
Size and weight
130 × 67 × 30 mm and about 200 g on the BH-4; 109 × 60 × 30 mm and about 130 g on BH-90
Sensor life
17500 h nominal, stated as dependent on the environment of use

A portable gas detector protects the person carrying it. Everything about the instrument follows from that: it runs on a battery for a shift, it has to survive being dropped, and it has to raise a warning its wearer cannot miss. What it does not do is protect a plant, and the two duties lead to different instruments with different priorities.

This range covers the two forms a personal detector is normally bought in - the four-channel instrument that carries the confined space combination in one hand-held body, and the single-channel instrument built around the one gas a task presents.

What it measures

Four quantities cover most of the work. Combustible gas is reported as a fraction of its lower explosive limit, because that is the figure which says how close the atmosphere is to being able to burn. Oxygen is reported in percent by volume and is measured for two opposite reasons: a deficiency can render a person unconscious without warning, and an enrichment makes everything present burn more readily. Carbon monoxide and hydrogen sulphide are reported in parts per million, at the concentrations that matter to a person rather than to a process.

The four channels belong together because a confined space can present all four at once and each of them is invisible to the others. A single-gas instrument answers one of those questions and is silent about the rest, which is why the risk assessment rather than the price decides which form is bought.

How the detection works

The combustible channel burns a small amount of the gas on a heated catalytic element and measures the heat released, which reads directly as a fraction of the lower explosive limit. It needs oxygen to work, and it is permanently poisoned by silicones, leaded compounds and some solvents - so the instrument is not merely less accurate in those atmospheres, it is finished.

Oxygen, carbon monoxide and hydrogen sulphide use electrochemical cells. Each reacts its gas at an electrode and produces a small current proportional to concentration. A cell is consumed by the gas it measures, so its remaining life follows exposure rather than the calendar, and the material quotes 17500 hours as a nominal figure while noting that the real number depends on the environment of use.

Each channel is then compared with its alarm thresholds, and the alarm is raised through a buzzer, an indicator lamp and a vibration motor together rather than through any one of them.

The four-gas combination and what else can be ordered

The standard four-channel instrument covers combustible gas, oxygen, hydrogen sulphide and carbon monoxide, with a two-stage alarm on each channel - a low setpoint that means stop and review, and a high setpoint that means leave. Those four are the combination confined space work is normally written around, and the thresholds the material gives are the conventional ones.

Beyond that, the material lists a configurable selection covering carbon dioxide, nitric oxide, nitrogen dioxide, sulphur dioxide, chlorine, hydrogen, ammonia, phosphine, hydrogen chloride, chlorine dioxide, hydrogen cyanide, ethylene oxide, ozone, formaldehyde, hydrogen fluoride and the xylene and toluene pair, among others, and states that more than 300 gases can be supplied to order. Two qualifications belong with that list. The first is that the material’s own gas table has some rows misaligned across its resolution and alarm columns, so the resolution and alarm value for any specific gas should be confirmed gas by gas rather than read off the list. The second is that a fourth or fifth channel changes the sensor set inside the instrument, and each sensor carries its own cross-sensitivity to other gases - so a channel added for one hazard is worth checking against what else may be present.

There is also a diffusion model that switches between methane, propane and isobutane, which is the form for flammable gas alone where no fixed piping identifies the gas in advance.

Choosing between the multi-gas and single-gas instrument

The choice follows from the number of credible hazards rather than from how much the wearer wants to carry. Where a space has to be tested before entry, the four-channel instrument is usually the answer, because entry procedures assume that a deficiency, an explosive atmosphere and a toxic exposure can all be present and that none of them announces itself. Where the task presents exactly one hazard - a purge line, a single process connection, a routine check on a known gas - the single-channel instrument is lighter, smaller and cheaper, and its limitation is simply that it says nothing about anything else.

The material gives the single-gas instrument fewer than 8 hours of continuous work on its 1500 mAh battery against the multi-gas model’s standby figure, so shift length belongs in the same comparison. Whichever form is chosen, a history of alarms stored on the instrument is worth keeping enabled: 4000 events are retained, and a record that exists is what makes an incident reviewable after the fact.

Diffusion or pumped sampling

A diffusion instrument responds only to the atmosphere at its own sensing elements. Carried into a space it protects the wearer while they are inside, which is what personal protection means. It cannot tell anyone what the atmosphere was before they entered, because it was not there.

The material notes that a sampling pump can be used to draw a sample from a position an operator cannot reach, which is the arrangement a pre-entry test requires - the instrument stays outside, the line goes in, and the reading is taken before anyone commits. The distinction matters more than any accuracy figure on the page, because the failure it prevents is not an inaccurate reading but a complete absence of one.

Measurement limitations and selection considerations

Several parameters that matter in selection are not stated in the material at all: the ingress protection of the enclosure, the flow and vacuum of a sampling pump, the working pressure range of the sample path, and the storage temperature range. Nothing here is inferred to fill those, and the material’s own statement that its figures are the supplier’s nominal values, to be confirmed against the delivered nameplate and the manual, applies to the whole page.

Four operational points are worth stating plainly. Zero must never be set in an atmosphere containing the target gas, because a zero taken in a contaminated atmosphere shifts every reading low - in the direction that hides a hazard. The material gives two different explosion protection markings, IIB and IIC, which are different gas groups; the marking on the delivered nameplate and its certificate are what the installation has to be signed off against. Sensor life shortens in high temperature, high humidity, corrosive gas and silicone vapour, so the replacement interval belongs to the site rather than to the catalogue. And a password protects part of the configuration, so the code has to be recorded by whoever administers the instruments, or a calibration cannot be carried out in the field.

Ordering

The items that fix the answer are the gases the risk assessment identifies, whether the work involves entry and therefore pre-entry testing, whether a sample has to be drawn from a distance, what else may be present that could affect a sensor, the length of the shift, and whether readings and alarms have to be recorded. State the space or the task rather than only a model, because the gas list is what decides the configuration. Quantity, destination port and required delivery date complete the enquiry.

Features

  • Four channels in one hand-held body, covering the combustible, oxygen, hydrogen sulphide and carbon monoxide combination that confined space procedures are usually written around
  • All three alarm modes active at once, so a warning is not lost on a wearer in a noisy area or inside heavy protective clothing
  • A modular serial port and individually replaceable sensors, so one channel can be serviced without the instrument going out of service
  • 4000 alarm events retained on the instrument, so the record of an alarm can be retrieved after the event
  • A zero setting and zero fine adjustment available to the user, with the material's own caution that zeroing must not be carried out in an atmosphere containing the target gas
  • Diffusion and switchable three-gas forms for flammable gas alone, and a list of further single gases available to order

Technical specifications

Every value below is taken from source documentation. Where a parameter is not stated in the available material it is marked as information required rather than estimated.

The standard four-channel combination
Combustible gas (EX)0-100 %LEL, resolution 1 %LEL, alarms at 20 %LEL and 50 %LELStandard
Hydrogen sulphide (H2S)0-100 ppm, resolution 1 ppm, alarms at 10 ppm and 35 ppmStandard
Carbon monoxide (CO)0-1000 ppm, resolution 1 ppm, alarms at 50 ppm and 150 ppmStandard
Oxygen (O2)0-30 %VOL, resolution 0.1 %VOL, alarms at 19.5 %VOL and 23.5 %VOLStandard
Instrument
Display error≤±5 %FSStandard
Response timeT90 < 60 sStandard
IndicationLCD showing live readings and system status, with light emitting diodes; sound and vibration indicating alarm, fault and low batteryStandard
Operating environment-10 to 50 °C; below 95 %RH without condensationStandard
Supply voltageDC 3.7 VStandard
Explosion protection markingThe material carries two markings: Exib IIB T3 Gb in its structure table and ExibIICT3Gb on the main image. IIB and IIC are different gas groups with different scope, and the delivered nameplate and certificate governInformation required
Charging time6 to 8 h on the multi-gas instrument; 4 to 6 h on the single-gas instrumentStandard
Standby timeStated as greater than 12 h continuous in the structure table, and as 16 to 18 h for the four-channel model on the endurance graphic. Actual runtime falls with temperature, alarm frequency and backlight useInformation required
Sensor life17500 h, approximately two years, stated as dependent on the environment of useStandard
Battery capacity1800 mAh rechargeable lithium on the multi-gas instrument; 1500 mAh lithium on the single-gas instrumentStandard
Dimensions130 × 67 × 30 mm on the multi-gas instrument; 109 × 60 × 30 mm on BH-90Standard
WeightAbout 200 g on the multi-gas instrument; about 130 g on BH-90Standard
AlarmSound, light and vibration together, with the indicator lamps set behind a transparent windowStandard
Alarm records4000 alarm eventsStandard
Display window, single-gas instrument1.7 inch LCDStandard
FunctionsChinese and English menu switching, password protection, zero setting and zero fine adjustment, gas calibration, modular serial portStandard
Ingress protectionNot stated in the materialInformation required
Sampling pump flow and vacuumNot stated in the materialInformation required
Working pressure rangeNot stated in the materialInformation required
Storage temperatureNot stated in the materialInformation required
Diffusion model, switchable between three gases
GasesMethane, propane and isobutane, freely switched betweenStandard
Range3-100 %LEL, resolution 1 %LELStandard
Alarms20 %LEL low and 50 %LEL highStandard
Gases available to order
Carbon dioxide (CO2)0-5000 ppm, resolution 1 ppmOptional
Nitric oxide (NO)0-250 ppm, resolution 1 ppmOptional
Nitrogen dioxide (NO2)0-20 ppm, resolution 0.1 ppmOptional
Sulphur dioxide (SO2)0-20 ppm, resolution 0.1 to 1 ppmOptional
Chlorine (CL2)0-1000 ppm, resolution 0.1 ppmOptional
Hydrogen (H2)0-1000 ppm, resolution 1 ppmOptional
Ammonia (NH3)0-100 ppm, resolution 0.1 to 1 ppmOptional
Phosphine (PH3)0-20 ppm, resolution 0.1 ppmOptional
Hydrogen chloride (HCl)0-20 ppm, resolution 0.001 to 0.1 ppmOptional
Chlorine dioxide (CLO2)0-50 ppm, resolution 0.1 ppmOptional
Hydrogen cyanide (HCN)0-100 ppm, resolution 0.01 to 0.1 ppmOptional
Ethylene oxide (C2H4O)0-100 ppm, resolution 0.1 to 1 ppmOptional
Ozone (O3)0-20 ppm, resolution 0.1 ppmOptional
Formaldehyde (CH2O)0-10 ppm, resolution 0.1 to 1 ppmOptional
Hydrogen fluoride (HF)0-10 ppm, resolution 0.01 to 0.1 ppmOptional
Xylene and toluene0-40 ppm, resolution 0.01 to 0.1 ppmOptional
Further gasesThe material states that more than 300 gases can be supplied to order, and that the table above is a partial selection. Resolution and alarm values in that table are listed gas by gas on requestInformation required
Construction
HousingHigh strength ABS, dust and rain resistant, with explosion-protected constructionStandard
Sensing elementsElectrochemical cells for oxygen, hydrogen sulphide and carbon monoxide; catalytic combustion for combustible gasStandard
Sensor replacementModular serial port design, so a sensor can be replaced and calibrated individuallyStandard
Protection against misoperationTwo level password protection for key functionsStandard
Panel layoutAlarm indicator lamps behind a transparent window, LCD, buzzer aperture, gas inlet apertures, keys and a USB charging socketStandard

Available models

Selection table
Model Configuration Key ranges Availability
BH-4 Multi-gas, four channels, rechargeable 1800 mAh lithium battery, 130 × 67 × 30 mm, about 200 g, charging time 6 to 8 h Combustible gas 0-100 %LEL, oxygen 0-30 %VOL, hydrogen sulphide 0-100 ppm, carbon monoxide 0-1000 ppm The four-channel instrument. Differs from the single-gas model in channel count, battery capacity, charge time and enclosure size
BH-90 Single gas, one channel, 1500 mAh lithium battery, 1.7 inch LCD, 109 × 60 × 30 mm, about 130 g, charging time 4 to 6 h Whichever single gas the order specifies, from the configurable list The single-channel instrument. The material gives its dimensions, weight, battery and display, and states continuous working of more than 8 h

Customization

  • Gas combination, drawn from the configurable list in the material or from the further single gases it states are available to order
  • A sampling pump, which the material notes can be used to draw a sample from a position the operator cannot reach

Certification and compliance

Certification documents not yet supplied

Certifications are only published once a certificate copy can be produced, so this section is deliberately empty rather than populated with assumed approvals. Tell us which approvals your application requires and we will confirm what is available for this instrument.

Parameters still to be confirmed

The following are required for a complete specification but are not stated in the documentation supplied to us. They are listed rather than estimated:

  • The full official model designation and what the BH prefix denotes, since the material gives it as a model code without definition
  • Ingress protection of the enclosure, which the material does not state for either instrument
  • Sampling pump flow rate and vacuum, and whether a pump is supplied with the instrument or separately
  • Working pressure range of the sample path
  • Storage temperature range
  • Whether the alarm thresholds can be adjusted by the user, since the material records them as fixed values without saying so either way
  • The certificate that applies to the explosion protection marking, and which of the two markings in the material the delivered instrument carries
  • Calibration interval and the calibration gas required for each channel
  • The validity period of the metrology certificate, where the instrument is used for statutory testing
  • Whether the Chinese and English menu languages can be changed on a delivered unit, and whether further languages are available
  • Warranty period and the terms that apply
  • An English-language datasheet and a definitive gas list with alarm values resolved gas by gas
  • Packaging dimensions and gross weight for freight calculation

Frequently asked questions

How do I choose between the multi-gas and single-gas instrument?

From the number of hazards the risk assessment identifies, not from the convenience of carrying less. The four-channel instrument covers the combustible, oxygen, hydrogen sulphide and carbon monoxide combination in one body, and it is the usual answer where a space has to be tested before entry because more than one hazard is credible there. The single-channel instrument is lighter and cheaper and is built around one gas, so it fits a task where one hazard is the only credible one. Where a second hazard is possible, a single-gas instrument gives no indication of it at all, and that is the failure mode the choice has to avoid.

Is a diffusion instrument enough, or do I need a pump?

It depends on whether the atmosphere has to be tested before anyone enters it. A diffusion instrument responds only to the atmosphere at its sensing elements, so it warns the wearer while they are inside the space, but it cannot tell anyone what the air was like before they entered. A confined space procedure normally requires the second, which means drawing the sample out through a line while standing outside. Where the work never involves entry and the instrument is worn as personal protection, diffusion is simpler and leaves both hands free.

What does the displayed figure for combustible gas actually mean?

It is a fraction of the lower explosive limit of the gas the instrument was calibrated against, not a concentration. The reading is only accurate for that gas, because a catalytic element responds differently to one flammable vapour than to another. The material lists methane, propane and isobutane as switchable on the diffusion model, which is the practical form of the same point: the instrument has to be told what it is looking at. Where a specific vapour is the hazard, the instrument is calibrated to it or the correction for it is applied.

Both a zero setting and a calibration are provided. What is the difference?

Setting zero tells the instrument what clean air reads, and calibrating tells it what a known concentration reads. The zero matters because drift in the baseline moves every reading, including the ones that are nowhere near an alarm. The material states plainly that zeroing must not be carried out in an atmosphere containing the target gas, which is worth keeping with the instrument rather than only in the manual, because a zero taken in a contaminated atmosphere shifts the readings low and the error is in the direction that hides a hazard. A recorded alarm event does not correct for either.

Request a quotation for the BH-4

Send the configuration you need and we will confirm availability, lead time and terms. Minimum order quantity is 1 pc.

Request for quotation

Request a quotation - BH-4

Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.

The more of this you can give us, the fewer exchanges are needed before we can quote.
No file chosen
Datasheet, drawing, BOM or photograph. One file, up to 10 MB (PDF, Office, image or ZIP).

By submitting this form you agree that we may contact you about this enquiry. We do not sell or share enquiry data. See our privacy policy.

Items held in stock are dispatched within 48 hours of order confirmation. Customized specifications are produced to order and typically ship within 2 to 10 days. Transit time then depends on the shipping method and destination.

Request a Quote WhatsApp