Temperature Measurement · Temperature Transmitters

Temperature Transmitter Module

Two-wire temperature transmitter module for RTD and thermocouple inputs, converting the sensor signal to 4-20 mA or 0-10 V from 24 VDC, with 0.2%FS accuracy and zero and span potentiometers.

Key specifications

Input
RTD: Pt100, Cu50, Cu100, Pt1000; thermocouple: B, E, J, K, N, R, S, T, WRe3-25, WRe5-26
Sensor range covered
-200 to 1800°C across the range of input types
Output
Two-wire 4-20 mA as standard; a 0-10 V version is listed separately
Accuracy
0.2%FS
Supply
24 VDC
Load
250 Ω or 500 Ω
Assigned output spans
-20-60°C through 0-600°C, in the steps listed in the selection table
Temperature coefficient
≤25 ppm/°C FS; for a Pt100 input the material also states ≤250 ppm/K FS on a 100°C span and ≤150 ppm/K FS above a 150°C span
Operating temperature
-30 to 80°C in the parameter table; -20 to +60°C given as the usual working range
Housing
PA66 flame-retardant nylon, 44×40 mm base, 22 mm high

A temperature transmitter module takes the raw signal from an RTD or a thermocouple and turns it into a standard loop signal that the rest of a control system can read. It exists because the two sensor families produce signals that a PLC input card, a recorder or a panel indicator cannot use directly: an RTD returns a small resistance that depends on lead length, and a thermocouple returns a few tens of millivolts that depend on the temperature of the terminals as much as on the temperature being measured. Conditioning that signal at the sensor, rather than at the far end of a long cable, is what the module is for.

The module on this page is a two-wire design on a 24 VDC supply, with an output of 4-20 mA as standard and a 0-10 V version on the same housing. Inputs cover the common platinum and copper resistance elements and eight thermocouple types, with tungsten-rhenium types and Pt1000 available to order, and the accuracy figure stated in the material is 0.2%FS. The base is 44×40 mm with an 8 mm pitch terminal block, two adjustment potentiometers and M3×5 mounting screws, and the housing is PA66 flame-retardant nylon.

Because the input type is a configuration rather than a separate instrument, one module type serves a wide span of process temperatures: the same housing covers a Pt100 at -200°C and a type B thermocouple at 1800°C, differing in the input set at order and in the output span assigned to it.

How a temperature transmitter works

The measurement chain starts at the element. A resistance element is read by passing a small excitation current through it and measuring the resulting voltage; the material gives that current as 0.2 mA, which is low enough that self-heating in the element stays small. A thermocouple is read as a voltage, and because that voltage is generated between the hot junction and the terminals where the wires land, the terminal temperature has to be known and compensated for. That compensation is the reason a thermocouple is connected to a transmitter with the correct thermocouple wire rather than with copper: copper joints introduce their own voltages at the point where the thermocouple wire ends.

The signal is then linearised and scaled. An RTD follows a published curve and a thermocouple follows a polynomial for its type, and the front end resolves the incoming signal finely enough that the linearisation is not the limiting error: the supplied material states a 24-bit sigma-delta converter, which is far more resolution than the 0.2%FS accuracy figure needs. Resolution and accuracy are different quantities, and it is the accuracy figure, together with the temperature coefficient, that describes what the module actually delivers.

The output stage drives a current loop. In a two-wire arrangement the same pair of wires carries both the supply and the signal, and the current drawn by the module is the measurement, so the module has to work on the voltage that remains after the loop resistance has taken its share. That is why the load and the supply are linked: a 250 Ω or 500 Ω load plus the cable resistance is what the 24 VDC supply has to drive, and the material states a limit on the lead resistance for that reason rather than as a cable recommendation.

Two potentiometers sit on the module for zero and span. They are there because the transmitter is the point in the loop where the installed assembly can be trimmed: the element’s tolerance, the lead resistance and the loop resistor all end up as a single offset and a single gain error, and both can be corrected at the module against a reference thermometer.

How to select the right transmitter

Start with the sensor, because the input type is fixed for the module. A Pt100 is the usual choice where the temperature has to be defensible and stays within its range; a thermocouple takes over where the temperature is high enough or the point is small enough that a resistance element is impractical. The material lists Pt100, Cu50, Cu100 and Pt1000 on the resistance side, and types B, E, J, K, N, R, S and T plus WRe3-25 and WRe5-26 on the thermocouple side.

Then the output span, which is the decision that most affects the reading in practice. The 4-20 mA loop carries a fixed current range, and the span assigned to it decides how much temperature each milliamp represents. Assigning a narrow span around the working range gives a finer reading over that range, but anything outside it clips. The material lists the assignable spans from -20-60°C up to 0-600°C in the steps given in the selection table, and a 0-100°C marking appears on the 0-10 V version.

Then the loop itself. The supply is 24 VDC and the load is stated as 250 Ω or 500 Ω, with a lead resistance limit to respect. Where the run is long, or the receiving instrument presents a heavier load, the available voltage at the module is what constrains the arrangement, and the material offers a build to order where the lead resistance on a Pt100 run exceeds 35 Ω.

Then the environment and the mounting. The material gives an operating range of -30 to 80°C in the parameter table but describes -20 to +60°C as the usual working range, and it also lists a transport and storage range of -40 to 120°C. The housing is a 44×40 mm base with M3×5 screws, which suits a panel or a field enclosure rather than a wall.

Finally the mating probe. The material documents probes to go with the module, including a rolled Pt100 of φ4×30 mm on a 0.5 m waterproof lead, a flat Pt100 of 7.5×20×3.6 mm, a threaded waterproof version on a 1.5 m lead with an M6×1 thread, and a high-temperature version on an M12×1 thread rated to 420°C. The lead insulation is not the same across those options, and only the stainless braided leads carry the high-temperature rating.

Limitations and points to confirm

The accuracy claim needs a reference to be meaningful. 0.2%FS is a percentage of the assigned span rather than of the measured temperature, so a 0-600°C span and a 0-50°C span produce quite different absolute errors from the same figure. The material states no reference standard behind it, so the figure should be read as the supplier’s specification and confirmed against a certificate where the application depends on it.

The two temperature coefficient figures are not reconciled. A general ≤25 ppm/°C FS and a Pt100-specific ≤250 ppm/K FS on a 100°C span differ by an order of magnitude, and the material does not say which inputs the general figure covers. Where the module operates away from the calibration temperature, that gap matters more than the accuracy figure does, and until it is resolved the wider figure is the safe one to assume.

Some limits in the material need reading carefully. The lead resistance limit is given as under 80 Ω for both a 500 Ω load and a 250 Ω load, which is unusual: the allowable lead resistance normally falls as the load rises, because both consume the same loop voltage. The figure has been flagged rather than published as two separate verified limits. The 20.3 mA output current limit is likewise a saturation figure, not an operating point.

Several parameters that a specification usually states are absent: ingress protection, humidity limits, the isolation voltage between input and output, and long-term stability. They appear on this page as information required rather than as estimates. The material also states that the components are imported without naming a grade or an origin, which is not published here because it cannot be substantiated from the supplied document.

Two practical points about the assembly. The material states that the mating probes are hand-assembled and may carry measurement variation, so the paired probe and transmitter should be treated as an assembly to be trimmed rather than as two independently interchangeable parts. And the product carries no model designation in the supplied document: the identification on the housing is a configuration label, so an order should state the input type, the output form and the assigned span rather than a code.

Features

  • Accepts both RTD and thermocouple inputs, so one module type covers eight thermocouple and three RTD signals rather than one module per sensor family.
  • Two-wire 4-20 mA output on a 24 VDC supply, which is the loop form most recorders, PLC input cards and panel indicators expect.
  • 0.2%FS accuracy from a 24-bit sigma-delta front end, per the supplied material.
  • Zero and span potentiometers on the module allow the installed loop to be trimmed against a reference rather than being accepted as supplied.
  • A 44×40 mm base with M3×5 mounting screws and an 8 mm pitch terminal block, for panel or field mounting.
  • PA66 flame-retardant nylon housing, with reverse polarity and surge protection stated as built in.
  • A 0-10 V version is listed on the same housing for inputs that cannot take a current loop.

Technical specifications

Every value below is taken from source documentation. Where a parameter is not stated in the available material it is marked as information required rather than estimated.

Input
RTD inputsPt100, Cu50, Cu100, and Pt1000 to orderStandard
RTD rangesPt100 -200 to 800°C; Cu50 -50 to 150°C; Cu100 -50 to 150°C; Pt1000 -50 to 200°C, to orderStandard
Thermocouple inputsB, E, J, K, N, R, S and TStandard
Thermocouple rangesB 300 to 1800°C; E 0 to 1800°C; J 0 to 1200°C; K 0 to 1300°C; N -200 to 1300°C; R 0 to 1700°C; S 0 to 1700°C; T -200 to 400°CStandard
Thermocouples to orderWRe3-25 and WRe5-26, 0 to 2300°COptional
Input type selectionSet for the sensor in use; the material lists eight thermocouple and three RTD signals as standard coverageStandard
Excitation current0.2 mAStandard
Analysis24-bit sigma-delta front end, per the supplied materialStandard
Output and electrical
Standard outputTwo-wire 4-20 mAStandard
Alternative output0-10 V version on the same housing, with outputs listed as 1-5 V, 0-5 V, 0-20 mA and 0-10 V in the supplied materialOptional
Supply voltage24 VDCStandard
Output current limit20.3 mAStandard
Loop load250 Ω or 500 ΩStandard
Lead resistance at 500 Ω loadStated as under 80 ΩStandard
Lead resistance at 250 Ω loadStated as under 80 Ω in the same noteInformation required
Reverse polarity and surge protectionPresent, per the supplied materialStandard
Loop resistance at other supply voltagesInformation requiredInformation required
Accuracy and stability
Accuracy0.2%FSStandard
Temperature coefficient, general≤25 ppm/°C FSStandard
Temperature coefficient, Pt100 input≤250 ppm/K FS on a 100°C span and ≤150 ppm/K FS above a 150°C span, as stated separately in the supplied materialStandard
Which figure applies to which inputInformation requiredInformation required
Reference standard behind the accuracy figureInformation requiredInformation required
Long-term stabilityInformation requiredInformation required
Environment and construction
Operating temperature-30 to 80°C in the parameter table; -20 to +60°C given as the usual range and available to other limits to orderStandard
Transport and storage temperature-40 to 120°CStandard
Housing materialPA66 flame-retardant nylonStandard
Mounting screwM3×5Standard
Base plate44×40 mmStandard
Terminal block width and pitch34 mm wide, 8 mm pitchStandard
Body height22 mmStandard
Mounting hole centre height12 mmStandard
Ingress protectionInformation requiredInformation required
Ambient humidity limitsInformation requiredInformation required
Isolation voltage between input and outputInformation requiredInformation required
Adjustment, warranty and documentation
Zero adjustmentLeft-hand potentiometer, clockwise to increaseStandard
Span adjustmentRight-hand potentiometer, clockwise to decreaseStandard
Warranty1 year, stated in the supplied materialStandard
CertificationInformation requiredInformation required
Test certificateInformation requiredInformation required
DatasheetInformation requiredInformation required
2026-11 supply batch
ScopeAdditional forms supplied in November 2026 for this product type. Figures below are from that batch; where they differ from the rows above, both are recorded rather than merged.Standard
InputPT100, CU50 and K, J, B, S or E type thermocoupleStandard
Output4-20 mA, RS-485/Modbus and 0-10 VStandard
Supply24 V DCStandard
Accuracyplus or minus 0.1 % and 0.2 classStandard
MountingDIN rail and head-mounted formsStandard
Ambient temperature-20 to 50 CStandard
Ingress protectionIP65, with IP67 versionsStandard

Available models

Selection table
Model Configuration Key ranges Availability
Pt100, 4-20 mA Two-wire transmitter, 0.2%FS, 24 VDC, output span set at order -200 to 800°C on a Pt100 input Assignable spans from -20-60°C to 0-600°C are listed
Pt100, 0-10 V Three-wire transmitter, 0.2%FS, 24 VDC Range marked 0-100°C in the supplied material Other outputs listed as 1-5 V, 0-5 V and 0-20 mA
Cu50 / Cu100 Two-wire transmitter, 0.2%FS, 24 VDC -50 to 150°C
Pt1000 Two-wire transmitter, 0.2%FS, 24 VDC -50 to 200°C Offered to order Made to order
Type K thermocouple Two-wire transmitter, 0.2%FS, 24 VDC 0 to 1300°C Also covers types E, J and T on the same module
Types B, N, R and S Two-wire transmitter, 0.2%FS, 24 VDC 300 to 1800°C depending on type
WRe3-25 / WRe5-26 Two-wire transmitter, 0.2%FS, 24 VDC 0 to 2300°C Offered to order Made to order

Customization

  • Assigned output span
  • Input type
  • 0-10 V output instead of 4-20 mA
  • Operating temperature range other than the standard limits
  • Pt1000 and tungsten-rhenium thermocouple inputs
  • Mating probe length, thread and lead arrangement

Certification and compliance

Certification documents not yet supplied

Certifications are only published once a certificate copy can be produced, so this section is deliberately empty rather than populated with assumed approvals. Tell us which approvals your application requires and we will confirm what is available for this instrument.

Parameters still to be confirmed

The following are required for a complete specification but are not stated in the documentation supplied to us. They are listed rather than estimated:

  • Model or part number for the module
  • Reference standard behind the 0.2%FS accuracy figure
  • Which temperature coefficient figure applies to which input type
  • Loop resistance limit at supply voltages other than 24 VDC
  • Ingress protection rating
  • Ambient humidity limits
  • Isolation voltage between input and output
  • Long-term stability figure
  • Certification held, if any
  • Test certificate
  • Datasheet in English
  • Whether the lead resistance limit differs between a 250 Ω and a 500 Ω load; the supplied material gives 80 Ω for both

Frequently asked questions

Does the module work with either an RTD or a thermocouple?

Yes, but the input type has to be set for the sensor in use. An RTD input reads resistance while a thermocouple input reads a millivolt signal, so a module configured for one will not measure the other correctly even though both connect to the same terminals.

What output span should I order?

The material lists assignable spans from -20-60°C up to 0-600°C, plus 0-50°C, 0-100°C, 0-150°C, 0-200°C, 0-250°C, 0-300°C, 0-350°C, 0-400°C and 0-450°C. The span is what the 4-20 mA loop covers, so it should be the working range of the process rather than the full range of the sensor: a narrower span gives finer resolution over that span, at the cost of clipping anything outside it.

Why are two temperature coefficients given?

The parameter table states ≤25 ppm/°C FS as a general figure, and a separate note gives ≤250 ppm/K FS for a Pt100 input on a 100°C span and ≤150 ppm/K FS above a 150°C span. The two figures are different in magnitude and the supplied material does not say which inputs the general figure applies to.

How is the module calibrated in service?

It carries two potentiometers. The left-hand one adjusts zero and increases clockwise; the right-hand one adjusts span and decreases clockwise. The material notes that a 1%, 0.5 W metal film load resistor is usually adequate for a current-output module but that the resistor tolerance itself has to be trimmed out with those potentiometers.

What does the supplied photograph show?

It shows probes with braided leads and fork terminals, which are the mating probes listed in the supplied material rather than the transmitter module itself. The module is a 44×40 mm base with a terminal block and the two adjustment potentiometers.

Is the two-wire connection the same as the four-wire one?

No. On a two-wire order, terminals 3 and 4 on the module are internally shorted, and the material asks that the lead resistance to the Pt100 be kept as low as possible. Where the run is long enough that a single lead exceeds 35 Ω, the material offers a build to order rather than accepting the error.

What is the warranty?

1 year on the module, as stated in the supplied material. Note that the material also states the mating probes are hand-assembled and should be expected to carry measurement variation, and that waterproof leads are rated -50 to 200°C while high-temperature leads reach 420°C but are not waterproof.

Related products

Other models in the same range

Two NTC thermistor probes with stainless steel sensing tips and coiled lead wires, one with a black cable and one with a grey cable

Resistance Temperature Detectors

NTC Thermistor Temperature Probe

Stainless steel NTC thermistor probe with a 10 kΩ element at 25°C and a 3950 K B value, supplied with lead wires and plug terminals for control boards and acquisition modules.

Resistance at 25°C
10 kΩ, ±1%
B constant B25/50
3950 K, ±1%
Thermal time constant
3 s, measured in stirred water from 25 to 50°C
Operating temperature
-30 to 180°C in the parameter table; -20 to 105°C on the main image
Clamp-on thermocouple with a threaded stainless steel head, a braided stainless steel lead and fork terminals with red and blue sleeves

Thermocouples

Clamp-On Thermocouple

Spring-clamp thermocouple with a stainless steel M12×1.5 threaded head and a braided high-temperature shielded lead, for moulds, extruders, heating bands and other points that need a probe pressed into place.

Calibration types
K and E thermocouple, plus a PT100 resistance variant in the same body
Measuring range
K 0 to 800°C; E 0 to 400°C; PT100 -200 to 450°C
Thread
M12×1.5, removable
Probe front
5 mm tube outside diameter, 10 mm protruding

Request a quotation

Send the configuration you need and we will confirm availability, lead time and terms. Minimum order quantity is 1 pc.

Request for quotation

Request a quotation - Temperature Transmitter Module

Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.

The more of this you can give us, the fewer exchanges are needed before we can quote.
No file chosen
Datasheet, drawing, BOM or photograph. One file, up to 10 MB (PDF, Office, image or ZIP).

By submitting this form you agree that we may contact you about this enquiry. We do not sell or share enquiry data. See our privacy policy.

Items held in stock are dispatched within 48 hours of order confirmation. Customized specifications are produced to order and typically ship within 2 to 10 days. Transit time then depends on the shipping method and destination.

Request a Quote WhatsApp