- Calibration types
- K and E thermocouple, plus a PT100 resistance variant in the same body
- Measuring range
- K 0 to 800°C; E 0 to 400°C; PT100 -200 to 450°C
- Thread
- M12×1.5, removable
- Probe front
- 5 mm tube outside diameter, 10 mm protruding
- Spring section
- 21 mm, with a rotating clamp head that sets the insertion depth
- Clamp seat
- 11.5 mm inside and 13 mm outside as standard, 18 mm high
- Threaded head
- 12 mm diameter × 34 mm
- Lead
- 1 to 5 m of braided stainless steel shielded high-temperature cable
- Conductors
- Two for K and E; three as standard for PT100, two or four to order
- Termination
- Fork terminals, red to positive and blue to negative; pin terminals to order
A clamp-on thermocouple measures the temperature of a machine surface or a drilled point by holding a spring-loaded probe against it. The measuring junction sits inside a small stainless steel tip, and the body that carries it is a rotating clamp with an extended spring, so the insertion depth can be set at the point of measurement rather than being fixed by the length of the probe. On injection moulding machines, extruders, moulds and heating bands, that is usually the practical difference: the probe has to be pressed into a nozzle, a barrel or a band in a place with no room for a threaded assembly and no access for a spanner.
The build on this page is type K as standard, with type E and a PT100 resistance element offered in the same body. Type K covers 0 to 800°C, type E 0 to 400°C and the PT100 -200 to 450°C. The threaded head is stainless steel M12×1.5 and unscrews, leaving a plain clamp-on probe where there is no threaded boss to use. The lead is a braided stainless steel sheath over a shielded high-temperature cable, in lengths from 1 to 5 m, and the tip material is iron.
The junction is welded rather than twisted. The supplied material makes a point of this: the two conductors are joined inside the tip by argon arc welding and insulated with a high-frequency ceramic tube, which is a different construction from the common practice of twisting the conductors together, and it is the difference that shows up as stability at the top of the range.
How a thermocouple works
A thermocouple produces a voltage rather than a resistance. Two dissimilar metals joined at one point generate a small potential difference when that junction sits at a different temperature from the other end of the wires, and the voltage is a few tens of microvolts per degree. Nothing has to be supplied to the sensor for it to work, which is why a thermocouple suits the top of the temperature range where a resistance element would drift, and why it can be made very small.
That same principle sets the constraints. Because the voltage is generated between the measuring junction and the terminals where the wires land, the temperature at those terminals is part of the measurement: the instrument has to know the terminal temperature and compensate for it. It also means the circuit has to be made up with the matching thermocouple wire throughout. Every place where the thermocouple wire meets a copper conductor is itself a thermocouple junction, and one that is not at the terminal temperature contributes an error rather than a connection.
The two junction forms in the supplied material follow from how the tip is built. In a grounded junction, the welded joint is also in electrical contact with the sheath, so heat reaches it quickly and the response is fast, but the measuring circuit is connected to whatever the sheath touches. In an ungrounded junction, the joint sits insulated inside the tip, which isolates the circuit at the cost of a slower response. The material offers both and states no response time for either, so the choice is on the grounds of the installation rather than a published figure.
Two further practical properties come from the construction. The braided sheath over the cable is a mechanical protector and a shield at the same time, which matters on a machine carrying drives and heaters where an unshielded millivolt signal picks up interference. And the sheath is stainless steel while the tip is iron, so the probe tolerates contact with the machine without the lead becoming stiff and brittle the way a plain polymer cable would near a hot band.
How to select the right clamp-on thermocouple
Start with the temperature and the instrument. The calibration type follows the range: type K to 800°C, type E to 400°C, or the PT100 variant where a resistance element suits the instrument better. From there the decision is forced, because the sensor has to match the input type of the temperature instrument it connects to. A PT100 on a type K input gives a plausible and wrong display, and the supplied material flags exactly that.
Then the mounting. Where the machine has a threaded boss at the measuring point, the stainless steel M12×1.5 head screws into it and the spring sets the contact pressure. Where it does not, the head is unscrewed and the probe is clamped directly. The clamp seat is 11.5 mm inside and 13 mm outside with an 18 mm height, and 12 mm and 14 mm versions are available to order, so the seat has to match the boss or hole it sits in.
Then the junction form, grounded or ungrounded, for the reasons above: speed against isolation.
Then the lead. The standard range is 1 to 5 m with 1 m, 5 m and 7 m named as the usual lengths, and other lengths to order. A run longer than the standard range means an extension, and an extension has to be made of the same thermocouple wire with matching connectors; the supplied material does not specify those. Where the lead passes near a hot surface, or along a moving axis, the braided sheath is what protects it, and the minimum bend radius for that is not stated.
Finally the termination. Fork terminals are standard with red to positive and blue to negative. Where the instrument terminal does not accept a fork, pin terminals can be made to order.
Limitations and points to confirm
The sensor is not a traceable measuring instrument on its own. The supplied material gives no accuracy class or tolerance for the thermocouple, and no response time, so this page states the ranges but not a measurement uncertainty. Where a reading has to be defended, the thermocouple needs to be paired with a transmitter or instrument whose accuracy is known and, ideally, verified against a reference.
The lead is a limit that is easy to overlook. A probe rated to 800°C at the tip does not mean the lead survives 800°C, and the supplied material does not state the temperature rating of the cable or its insulation. The measuring point and the route the lead takes therefore need to be considered separately.
Several properties named in the material are not quantified. The probe is described as able to bend and to withstand high pressure, but no minimum bend radius and no pressure figure are given, so neither is published here. The material also gives a standard lead range of 1 to 5 m and then includes 7 m among the usual lengths, which is outside that range as stated.
Finally the identification is open. The supplied material gives the calibration type under the model field rather than a part number, and a calibration type is common to every supplier of that thermocouple, so it is not used here as an identifier. An order should state the calibration type, the junction form, the lead length, the termination and the clamp seat dimensions.
Every value below is taken from source documentation. Where a parameter is not stated in the available material it is marked as information required rather than estimated.