Product type

pH Meters

A pH meter measures the acidity or alkalinity of a sample by immersing an electrode in it and reading the result on the spot. Electrode and display are one instrument, whether that is a pen body with the probe at its tip, a hand-held unit on a short cable, or a bench instrument with a stand holding a separate probe. What it does not do is stay anywhere or report to anything: a meter is carried to the sample, read, and put down again.

What a pH meter is

A pH meter measures the acidity or alkalinity of a sample by immersing an electrode in it and reading the result on the spot. Electrode and display are one instrument, whether that is a pen body with the probe at its tip, a hand-held unit on a short cable, or a bench instrument with a stand holding a separate probe. What it does not do is stay anywhere or report to anything: a meter is carried to the sample, read, and put down again.

That is what separates it from a pH analyzer, which is fixed in a line or a tank and holds a current output for a control system. The two are not competing instruments. A laboratory that works to a specification usually ends up with both, the analyzer for the continuous value and the meter for the checks around it, and the meter is also what makes a reading possible where there is no line to install anything into at all.

The difficulty in buying one is rarely the electronics. It is the electrode, the form of the probe and the routine the reading will be calibrated by, because those decide what can be measured and whether the number can be trusted. This page covers those decisions, and the boundary against the types an enquiry for a pH meter often turns out to be.

How a pH meter measures

A glass sensing bulb and a reference element form an electrochemical cell, and the voltage across it depends on the hydrogen ion activity of the solution the bulb sits in. The response is logarithmic, so equal steps in pH correspond to equal steps in voltage rather than proportional ones, and the meter converts that voltage into a pH value at the temperature it has measured. The reading rests entirely on a calibration established against buffer solutions of known pH, which is why a meter is only as good as the buffers it was set against.

Three facts follow in practice. The bulb is a consumable: it ages, it is attacked by hydrofluoric acid, and it dehydrates if it is allowed to dry out between uses, so it must be kept wet. The reference half of the cell is as important as the measuring half, and a partly blocked junction shows up as a reading that drifts or responds slowly, which no recalibration cures. And temperature enters twice, once as a correction the meter applies to the electrode response and once as a property of the sample itself - a compensation circuit corrects the first and not the second.

The instrument form then decides what is practical. A pen meter goes anywhere with nothing to set down and no cable to trail, which is what makes a survey across many points possible. A bench meter holds the probe in a stand so the electrode can settle undisturbed while the reading is taken, which is what makes a repeatable result easier to get. The electronics inside both are similar; how the probe is presented to the sample is what changes.

Configuration choices

Most of the specification is fixed by these decisions rather than by the accuracy class. Each one constrains the next, which is why they are settled in order.

ConfigurationOptions to fixWhat it actually decides
Instrument form Pen or pocket body, hand-held unit on a cable, and bench instrument with a standWhere the meter can be used and how the sample is reached. A pen meter needs no bench and no cable; a bench meter lets the probe settle undisturbed.
Reading resolution 0.1 pH, 0.01 pH, and finer on specialised instrumentsWhether the result can be compared against a specification at all. A reading given to 0.1 pH cannot resolve a difference of 0.05.
Probe form Spherical bulb, spear, long spear, and flat or surface formWhat can be measured: a liquid sample, a semi-solid pushed into, a bulk volume, or a surface and a small volume.
Electrode construction Glass bulb or non-glass body, and a sealed or refillable reference junctionHow the probe behaves in the medium and how long it survives there before it has to be replaced.
Temperature compensation Automatic from an integral sensor, or manual entry of the sample temperatureWhether a reading taken at one temperature can be compared with a reading taken at another.
Calibration arrangement One, two or three buffer points, and whether the meter recognises the buffer and reports the slopeHow much of the accuracy rests on the operator following a routine, and how much the instrument absorbs itself.
Reading functions Hold, minimum and maximum, stability indication, and internal loggingWhether a value can be captured away from the bench, and whether a series of readings can be kept without being written down.
Sealing and supply The cell or battery form, and the ingress protection of the bodyWhether the meter can be used in a wet area or rinsed, and how long it runs between cell changes.

How to choose a pH meter

FactorWhy it decides the answerHow to settle it before enquiring
What the sample actually is A liquid, a semi-solid, a surface and a small volume each need a different probe formDescribe the state of the sample, not only its name.
Required resolution and accuracy It follows from the limit the result is judged against, not from the instrumentState the acceptance limit, and the value it applies to.
Temperature of the samples It drives both the electrode choice and whether compensation is sufficientGive the normal and maximum sample temperature.
Chemical environment Hydrofluoric acid, strong caustic, sulphides and proteins each attack a different part of the cellList every medium the probe will see, including cleaning agents.
Where the meter will be used A bench, a tank side, a wet floor and a field survey make different demands on the body and on the sealingDescribe the location, and whether it is wet or hosed down.
How the results are kept A notebook, or a value captured from the instrumentState whether the reading has to be logged, exported or only seen.
How it will be calibrated The number of buffer points and the availability of fresh buffers set the ceiling on the accuracy achievedSay who calibrates, how often, and with what.

If any of these are still open, send what is known. A quotation can be issued against a duty description and refined once the gaps are filled.

The nearest alternatives

These are the types an enquiry for a pH meter usually turns out to be, and the point at which the choice is genuinely decided.

Nearest alternativeWhat separates it from a pH meter
pH analyzers The same electrode chemistry installed in the line and held there, with a current output, alarm contacts and often a cleaning arrangement. A meter is carried to a sample and read; an analyzer is fixed and reports continuously. Where a value has to be logged, transmitted or used to dose, that is the analyzer, and the meter becomes the portable check against it.
Process pH meters A fixed installation intended for local indication rather than for a control loop. It sits between the two: it stays in place like an analyzer but drives nothing. Where someone simply has to see the value at the tank, this is the instrument; where the reading has to act, it is not.
ORP meters and analyzers Measures the tendency of the solution to oxidise or reduce, in millivolts, rather than its acidity. Disinfection control is normally an ORP duty, because the sanitising power of a chlorinated stream depends on more than its pH. Neither measurement substitutes for the other where a regulation names both.
Conductivity meters Counts dissolved ions rather than hydrogen ions, which is what makes it robust in dirty streams and useful for rinse water and contamination checks. It needs no reference junction and no calibration against buffers. It cannot tell an acid from a base, and it is usually bought alongside a pH meter rather than instead of one.
TDS meters Reports total dissolved solids, usually derived from a conductivity reading. It answers how much is dissolved, not whether the solution is acid or alkaline, and it is unaffected by the balance between the two.
Colour comparison strips and comparators Give a result against a printed colour scale, with no electrode, no calibration and nothing to store wet. They suit a rough check where the value only has to sit inside a band. They have no resolution to report, no record and no output, and colour or turbidity in the sample interferes with the reading.

The first three of these are fixed installations rather than instruments in the hand, and the last three answer a different question. Settling which of them the requirement actually is, before the meter is chosen, is cheaper than discovering it after the samples are already being run.

What to include in the enquiry

The first reply can be a quotation rather than a set of questions if the enquiry carries these. Where a figure is not known, send the duty description and we will confirm what it implies.

  1. What the sample is, and whether it is a liquid, a semi-solid, a surface or a small volume
  2. The expected pH range, and the specification or limit the result is compared against
  3. Normal and maximum sample temperature
  4. Every medium the probe will see, including cleaning agents
  5. Whether the instrument is used at a bench, at a tank side, or in the field
  6. Whether the reading has to be logged, exported, or only seen and written down
  7. How the meter will be calibrated, and with what buffers
  8. Whether the instrument has to work in a wet or washdown location
  9. Quantity, destination port and required delivery date

Available products

1 model in pH Meters

Hand-held pen shaped pH meter with a light grey body, a dark grey cap at the top and a tapered probe at the foot, its display showing 7.49 pH above a reading of 30.1 degrees Celsius, with three buttons below the screen

PH848 (5 models) · pH Meters

Pen Type pH Meter

Pen type pH meters in five models across two accuracy grades, with the electrode and the display in one hand-held body, automatic temperature compensation and a selectable probe form.

Models
PH848, PH838, PH818, PH828 and PH828+ across two accuracy grades
pH range
0.0~14.0 on PH848; 0.00~14.00 on PH838, PH818, PH828 and PH828+
Resolution and accuracy
0.1 resolution at ±0.1 pH on PH848; 0.01 resolution at ±0.05 pH on the other four
Repeatability
0.1 on PH848; 0.03 on the other four

Also in Laboratory Instruments

Other product types in this category

Every type we quote for under Laboratory Instruments. A type with no link yet is still quoted for - it is described on the Laboratory Instruments overview, and gets a page of its own as soon as a model is published against it.

Frequently asked

pH Meters questions

How often does a pH meter have to be calibrated?

In practice the interval follows the work rather than the calendar. A meter that is used daily is normally calibrated at the start of each session, and again if the reading is going to be compared against a specification or entered into a record. A two point calibration across the range of interest is the usual routine, three points where the work spans a wider range. What matters more than the number of points is the condition of the buffers: a calibration set against stale or contaminated buffer produces a confident wrong answer, which is worse than an obviously unstable one.

Why does the reading drift or respond slowly?

Almost always because of the electrode rather than the meter. A dehydrated bulb, a film of sample coating the glass, a partly blocked reference junction and an aged sensor all produce a reading that will not hold, and recalibrating an electrode in that condition moves the error rather than removing it. The sequence that works is to clean the electrode, check the reference, calibrate in fresh buffer, and replace the electrode when it will no longer pass. A meter that behaves well in buffer and badly in the sample is reporting the sample, not a fault.

Pen meter, hand-held meter or bench meter?

It follows from where the readings are taken and how much the number is worth. A pen meter with the probe built into the body is the instrument for a survey across many points, for a quick check away from a bench, and for a sample that can be reached with nothing but a hand. A hand-held meter on a cable keeps the display out of the container, which suits a tank, a channel or a sample that is awkward to reach. A bench meter holds the probe in a stand so it can settle undisturbed against a readable display, which is what makes a repeatable result easier and is why it is the form used where results are recorded against a specification.

How should the electrode be treated between measurements?

It must not be left dry. A glass bulb that dries out takes a long time to recover, and may not recover at all, so the electrode is kept wet between uses and rinsed with clean water between samples so that one sample does not carry into the next. It should also not be left standing in a sample for long periods, because that coats and eventually attacks the bulb. Treating the electrode as the consumable it is, and replacing it on a routine rather than on failure, is what keeps a meter reading consistently rather than intermittently.

Quoting for pH Meters

Send the specification and we will confirm the matching model, availability and lead time. Minimum order quantity is 1 pc.

Request for quotation

Request a quotation - pH Meters

Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.

The more of this you can give us, the fewer exchanges are needed before we can quote.
No file chosen
Datasheet, drawing, BOM or photograph. One file, up to 10 MB (PDF, Office, image or ZIP).

By submitting this form you agree that we may contact you about this enquiry. We do not sell or share enquiry data. See our privacy policy.

Items held in stock are dispatched within 48 hours of order confirmation. Customized specifications are produced to order and typically ship within 2 to 10 days. Transit time then depends on the shipping method and destination.

Request a Quote WhatsApp