Electrical Test & Measurement · Electrical Test Equipment

Two-Channel Digital Storage Oscilloscope

Two-channel digital storage oscilloscope with 100 MHz bandwidth, 1 GSa/s sampling, 64 kpoint memory, a 7 inch display and recording of up to 1000 screens.

UTD2102CEX+ (3 models) ·

Key specifications

Bandwidth
100 MHz on UTD2102CEX+; 150 MHz on UTD2152S-E; 200 MHz on UTD2202CEX+
Channels
Two analog channels, with independent coupling settings
Sampling rate
1 GSa/s maximum
Memory depth
64 kpts
Display
7 inch TFT LCD, WVGA 800 × 480
Waveform recording
Up to 1000 screens recorded and replayed
Automatic measurement
34 waveform parameters, with manual, tracking and automatic cursors
Frequency counter
Six digits, on the trigger signal
Input
1 MΩ in parallel with about 16 pF
Body
306 × 138 × 124 mm, about 3 kg

An oscilloscope answers a question a multimeter cannot: not what the value is, but what the signal did between two instants. The instrument in this range is the bench version of that question - two channels, a screen large enough to compare them, and enough memory to keep what it captured.

Product overview

Three models share a body, a display and a control layout. They differ in bandwidth: 100, 150 and 200 MHz, with the same two channels, the same record length and the same maximum sampling rate.

The front panel is arranged in the conventional way: a column of menu keys beside the screen, then vertical, horizontal and trigger blocks to the right, with the two BNC inputs below. Anyone who has used a bench scope before can drive it without reading the manual, and the AUTO key covers the case of someone who has not.

The case is about the size of a large book and weighs around three kilograms. It has a handle and feet, which is what a bench instrument needs if it is shared between two stations.

How the oscilloscope captures a signal

The input passes through an attenuator and a buffer, and is then sampled by an analogue-to-digital converter at up to one gigasample per second. The samples go into a record memory, and the record is what the instrument displays, measures and stores.

Two numbers govern what can be seen. Bandwidth sets the fastest edge the instrument can reproduce: a signal with significant content above the bandwidth arrives attenuated and rounded, whatever the sampling rate. Sampling rate sets how finely the record is spaced in time. Memory ties the two together, because at a given sample rate the record covers a fixed amount of time - a longer record means a longer window at full resolution.

Triggering decides which part of the stream is kept. The trigger circuit watches for a defined condition - an edge, a pulse width, a slope - and the acquisition is stored around that point. The frequency counter works from the same trigger signal, which is why it gives a stable reading without a separate measurement setup.

The measurement engine works on the stored record rather than on the live signal. That is why a frozen acquisition can be measured, cursors placed and parameters read after the event, and why recording successive screens is useful: the analysis can wait until the fault has been found.

How to select the right model

Bandwidth is chosen from the fastest edge, not from the repetition rate. A rule of thumb is to have several times the bandwidth of the highest significant frequency in the signal, so that the edge is reproduced rather than rounded. Where the shape of the edge is the measurement, more bandwidth is always the safer choice.

Channel count is chosen from what has to be compared at once. Two channels cover input against output, gate against drain, or a voltage against a current derived from a shunt. A third and fourth channel change the instrument class and are not available in this body.

Memory is chosen from the time window that has to be captured at full resolution. Looking at a switching edge and looking at a start-up sequence are different requirements, and the second one is where a short record becomes visible.

Connectivity is chosen last. A bench that records results needs the USB host for a memory stick or the USB device port for a computer; a bench that sorts parts needs the pass and fail output, which is not stated for every model here.

Measurement limitations and selection considerations

A probe is part of the measurement, not an accessory. A switchable passive probe in the 10:1 position loads the circuit far less than in the 1:1 position, but it also attenuates the signal and, at high frequency, the probe’s own compensation has to be adjusted against the calibrator on the front panel. An uncompensated probe produces a square wave that looks rounded or peaked, and the error is easy to attribute to the circuit.

Bandwidth and sampling rate are not interchangeable. A 100 MHz instrument sampling at 1 GSa/s gives ten samples per cycle at its bandwidth limit, which is adequate for viewing but marginal for measuring rise time. Where the edge is the measurement, the rise time specification matters more than the bandwidth headline.

The record length limits slow signals. At a slow time base, the sample rate falls unless the memory is deep enough, and the trace can look continuous while actually being reconstructed from far fewer points than the display suggests.

Finally, the instrument measures voltage against time. Current, power and impedance are derived from that, using a shunt, a probe or a maths function, and each of those introduces its own error. A current waveform from a clamp is only as good as the clamp’s bandwidth and its stated transfer ratio.

Features

  • A 7 inch WVGA display, large enough to read two traces and the menu at the same time without crowding the graticule
  • Recording of up to 1000 screens, replayed on the instrument, so an intermittent event can be captured and examined afterwards rather than chased live
  • 34 automatic measurements with manual, tracking and automatic cursors, which covers the quantities most benches record
  • Independent coupling on the two channels, so a signal and its offset can be viewed on different terms at the same time
  • A six-digit trigger frequency counter, which gives a stable frequency reading without setting up a measurement
  • AUTO key that sets vertical, horizontal and trigger from the incoming signal, which is what makes the instrument usable by someone who does not use a scope daily
  • USB host for a memory stick, screenshot capture and firmware update from a file, without a computer
  • Two switchable 1:1 and 10:1 probes supplied as standard
  • A compact body at about 3 kg with a handle, so it can be moved between benches

Technical specifications

Every value below is taken from source documentation. Where a parameter is not stated in the available material it is marked as information required rather than estimated.

Acquisition, UTD2102CEX+
Analog bandwidth100 MHzStandard
Analog channelsTwoStandard
Maximum sampling rate1 GSa/sStandard
Memory depth64 kptsStandard
Rise timeNot stated in the material for this modelInformation required
Vertical sensitivityNot stated in the material for this model; 1 mV/div to 20 V/div is given for UTD2152S-EInformation required
Time base rangeNot stated in the material for this model; 2 ns/div to 50 s/div is given for UTD2152S-EInformation required
Waveform capture rateNot stated in the material for this model; at least 5,000 waveforms per second is given for UTD2152S-EInformation required
Acquisition, other models in the range
UTD2152S-E150 MHz, two channels, 64 kpts, 1 GSa/s; rise time ≤ 2.4 ns; 1 mV/div to 20 V/div; 2 ns/div to 50 s/div; at least 5,000 waveforms per secondStandard
UTD2202CEX+200 MHz, two channels, 64 kpts, 1 GSa/s; other figures not stated in the materialStandard
Display and measurement
Screen7 inch TFT LCD, WVGA 800 × 480Standard
Automatic measurements34 waveform parametersStandard
CursorsManual, tracking and automaticStandard
Trigger frequency counterSix digitsStandard
Trigger types on UTD2152S-EEdge, pulse width, slope, video and alternateStandard
Trigger types on the wider rangeThe material also lists over-amplitude, N-edge, code error, duration, setup and hold, and pattern triggers, attributed to other models in the family rather than to UTD2102CEX+Information required
Acquisition strategyAUTO key sets the vertical, horizontal and trigger controls from the inputStandard
Storage and interfaces
Storage modesSettings, waveform and bitmapStandard
USB hostUSB stick for waveform storage, screenshot capture and software updateStandard
USB deviceType B socket for communication with a computerStandard
Rear panelUSB device socket and a pass and fail output on BNC, depending on the modelStandard
Pass and fail outputStated for UTD2152S-E; whether UTD2102CEX+ carries it is not statedInformation required
Power and environment
Mains100 to 240 V AC rms at 50 or 60 Hz; the rear label adds 400 Hz at 100 to 120 V and 100 VAStandard
Power consumption100 VA, from the rear panel labelStandard
Body dimensions306 × 138 × 124 mm from the dimension drawing; the comparison table gives 306 × 138 × 107 mm for most models in the familyStandard
WeightAbout 3 kgStandard
Operating temperature and humidityNot stated in the materialInformation required

Available models

Selection table
Model Configuration Key ranges Availability
UTD2102CEX+ Two-channel digital storage oscilloscope, 100 MHz, 64 kpts, 1 GSa/s, 7 inch display 100 MHz; two channels; 1 GSa/s; 64 kpts The model described in detail in the material, and the one the supplied photograph shows
UTD2152S-E Two-channel digital storage oscilloscope, 150 MHz, 64 kpts, 1 GSa/s 150 MHz; rise time ≤ 2.4 ns; 1 mV/div to 20 V/div; 2 ns/div to 50 s/div The model in the range whose additional figures are stated
UTD2202CEX+ Two-channel digital storage oscilloscope, 200 MHz, 64 kpts, 1 GSa/s 200 MHz; two channels; 1 GSa/s; 64 kpts Listed in the material with bandwidth, channels, memory and sampling rate only

Certification and compliance

Certification documents not yet supplied

Certifications are only published once a certificate copy can be produced, so this section is deliberately empty rather than populated with assumed approvals. Tell us which approvals your application requires and we will confirm what is available for this instrument.

Parameters still to be confirmed

The following are required for a complete specification but are not stated in the documentation supplied to us. They are listed rather than estimated:

  • The full specification of UTD2102CEX+ beyond bandwidth, channels, memory and sampling rate, since the supplied comparison table does not include this model
  • Rise time, vertical sensitivity, time base range and waveform capture rate for UTD2102CEX+
  • The trigger types available on UTD2102CEX+, given that the material attributes different lists to different models in the family
  • Whether UTD2102CEX+ carries the pass and fail output, which is stated for UTD2152S-E only
  • The operating temperature and humidity range
  • The conformity standards the instrument is built to, and whether a CE or UKCA declaration is available
  • Calibration certificate availability and interval
  • Warranty period and its terms
  • The probe model supplied as standard and whether the 1:1 and 10:1 switching applies to both probes
  • Whether the model designation carries a trailing plus sign, since the material uses both forms
  • The body depth, given as 124 mm on the dimension drawing and 107 mm in the comparison table

Frequently asked questions

Is 100 MHz enough for switching supplies and motor drives?

It depends on the edge speed rather than on the switching frequency. A 100 MHz instrument with a stated rise time can resolve edges down to a few nanoseconds, which covers the switching devices in most low-voltage supplies and drives. Where the edge itself is the measurement - gate drive, current-sense spikes, ringing on a fast transition - a wider bandwidth instrument is the right choice, and the 150 and 200 MHz models in this range exist for that.

What does the 64 kpoint memory limit?

The combination of time base and memory sets how much of the record is captured at full resolution. At a fast time base the record is short; at a slow time base either the sample rate drops or the acquisition covers less time than the screen suggests. For looking at a mains cycle or a slow start-up sequence, deep memory matters more than bandwidth, and a model with a larger record is the better answer.

What is the recording function for?

For events that do not repeat on demand. The instrument records successive screens into its own memory, and the sequence can be replayed to find the one acquisition where the fault appears. That is a different job from a single-shot trigger: it does not require knowing in advance what the fault looks like.

What is needed before a quotation?

The signals to be viewed and their bandwidth, including the fastest edge rather than the repetition rate; the number of channels needed at once; the time window that has to be captured at full resolution, which decides the memory; and whether results have to be saved to a computer or a USB stick. Probe type and quantity should be stated at the same time.

Related products

Other models in the same range

Benchtop digital multimeter in a grey housing, with a green vacuum fluorescent display showing two readings, a column of function keys down the centre of the panel and four input terminals on the right

TH1941 (6 models) · Digital Multimeters

Benchtop Digital Multimeter

Benchtop digital multimeter range in 4½, 5½ and 6½ digit models, with dual VFD or colour LCD displays, DCV to 1000 V, four-wire resistance and USB, GPIB or RS232 control.

Resolution grades
4½ digit at 21,000 or 51,000 counts; 5½ digit at 119,999 or 120,000 counts; 6½ digit at 1,199,999 counts
DC voltage
200 mV to 1000 V on TH1941; 500 mV to 1000 V on TH1942; 100 mV to 1000 V on the 5½ and 6½ digit models
AC voltage
200 mV to 750 V on TH1941; 500 mV to 750 V on TH1942; 100 mV to 750 V on the 5½ and 6½ digit models
Tightest one-year DCV uncertainty
0.02% of reading + 0.008% of range on TH1942
Wide benchtop AC source with a colour screen showing voltage, current, power and frequency at 220 volts and 50 hertz, a column of function keys, a rotary knob and a universal output socket at the right

YP4035 (7 models) · Electrical Test Equipment

Programmable AC Power Source

Programmable AC source from 350 VA to 10 kVA, with 45 to 400 Hz output, two voltage ranges, 2% distortion and RS-232 control for bench and line testing.

Capacity
350 VA to 10 kVA across seven models
Output voltage
1.0 to 150.0 V on the low range, 150.1 to 300.0 V on the high range
Frequency
45 to 400 Hz, 0.1 Hz steps, with 50, 60 and 400 Hz shortcut keys
Distortion
2% total harmonic distortion or less

Request a quotation for the UTD2102CEX+

Send the configuration you need and we will confirm availability, lead time and terms. Minimum order quantity is 1 pc.

Request for quotation

Request a quotation - UTD2102CEX+

Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.

The more of this you can give us, the fewer exchanges are needed before we can quote.
No file chosen
Datasheet, drawing, BOM or photograph. One file, up to 10 MB (PDF, Office, image or ZIP).

By submitting this form you agree that we may contact you about this enquiry. We do not sell or share enquiry data. See our privacy policy.

Items held in stock are dispatched within 48 hours of order confirmation. Customized specifications are produced to order and typically ship within 2 to 10 days. Transit time then depends on the shipping method and destination.

Request a Quote WhatsApp