Temperature Measurement · Temperature Recorders

Multi-Point Temperature Scanner and Recorder

Eight or sixteen channel thermocouple scanner with a 5 in touchscreen, a scan interval from one second to a day, live-circuit rating and MODBUS RTU communication.

HG-8 (2 models) ·

Key specifications

Channels
8 on the HG-8, 16 on the HG-16
Thermocouple types
K, T, J, E, S, N, B and P
Range
−200 to 1350 °C
Accuracy
±0.5% ±0.6 °C
Scan interval
1 to 99999 s per scan
Display
5 in full touchscreen, all channels on one page
Live-circuit rating
AC 400 V and DC 600 V
Alarms
Upper and lower limit per channel, shown by colour change and buzzer
Communication
USB as standard; RS-232 or RS-485 to order, MODBUS RTU
Mains
AC 220 V ±10%, with a 90 to 265 V option

Sixteen points on one screen is not a convenience, it is a different way of reading a test. The operator sees which channel is out of line at a glance, instead of scrolling through numbers that all look alike.

Product overview

Two models, one panel. The HG-8 carries eight thermocouple inputs and the HG-16 sixteen, on the same 5-inch touchscreen and in the same body. Both accept the same eight thermocouple types and share the same range and accuracy, so the choice between them is a count of points and nothing else.

The front panel holds the screen, two USB sockets, the power switch and a keypad with a round OK key and a row of function keys down the side. The rear holds the green thermocouple terminals, the fuse and the mains inlet. A mating thermocouple plug seats directly in the terminal, which keeps a probe change to a plug change rather than a screwdriver job.

The screen shows every channel at once with its tag and its reading. Channels that have crossed a limit change colour, and the buzzer sounds unless it has been muted. There is no curve page: this is an instrument for watching values against limits, not for studying the shape of a profile.

How the multi-point temperature scanner works

The inputs are isolated from one another before they reach the scanner, which is what allows the instrument to sit beside a drive or a contactor panel without the readings moving. Isolation is not the same as accuracy, but on a bench with switching equipment it matters more than another digit of resolution.

The scanner steps through the channels at the interval set on the panel, converts each thermocouple voltage with the curve for the type assigned to that channel, and compares the result with that channel’s upper and lower limits. The comparison happens as the sample is taken, so the alarm and the stored value agree.

Storage is a USB drive in the front socket, with the PC software on it. The same data can leave over the optional serial port in MODBUS RTU, which is the route to take when a PLC or a supervisory system has to see the channels without a person present.

How to select the right scanner

Count the points, then count them again with the ones that will be added later. Eight and sixteen are the only two sizes, and the difference in price is small next to a second instrument or a switched input box, so the larger model is often the calmer purchase.

Check the thermocouple types. All eight are supported on both models, but a probe of a type the instrument does not carry a curve for will read garbage rather than read approximately, so the list matters more than the count.

Then look at what the scanner has to connect to. A USB drive is enough for a report at the end of a shift; a serial link is needed when the readings have to enter a control system. Choose that at the order, because the port is a factory option.

Finally, be honest about the interval. A test that is watched in real time wants seconds; a test that runs unattended for days wants minutes or hours. The setting is one number for all channels, so a mixed test has to be planned around the shortest interval any of them needs.

Measurement limitations and selection considerations

One accuracy figure is quoted for all eight thermocouple types, and that is rarely how thermocouples behave. A type B couple at low temperature and a type K couple at the same temperature do not carry the same uncertainty, and the figure on the label does not separate them. Where the measurement matters, the probe’s own tolerance should be established first.

The live-circuit rating describes the input, not the installation. Whether a probe can be clipped to a live conductor depends on its insulation, its sheath and the condition of its lead, and on whether one end is earthed. A recorder rated for the voltage will still be damaged by a fault path through its terminals.

Scanning is sequential rather than simultaneous, so a fast event appears at different times on different channels. And because there is no curve page, the instrument shows the present state rather than the history: if the shape of a profile matters, a recorder with a trend view is the right instrument and this one is not.

The operating range of the instrument itself also sets a limit. It is specified for a workshop environment, not for a chamber, so a unit placed inside the heated space will fail long before the probes do.

Features

  • Eight thermocouple types on both models, including type P alongside the more common K, J and T
  • A scan interval that stretches to 99999 seconds, for processes that change over a day rather than a second
  • Channels are isolated from one another, which keeps a noisy channel from disturbing its neighbours
  • Live-circuit rating stated at AC 400 V and DC 600 V, for probes clipped to powered equipment
  • Per-channel upper and lower limits, signalled by colour change and buzzer rather than by a shared alarm relay
  • USB storage with the PC software on the drive, and MODBUS RTU over RS-232 or RS-485 when the scanner has to feed a control system
  • Thermocouple plugs seat directly in the rear terminals, so a probe change is a plug change

Technical specifications

Every value below is taken from source documentation. Where a parameter is not stated in the available material it is marked as information required rather than estimated.

Measurement
Channels8 on the HG-8 and 16 on the HG-16; the parameter table lists both in one column setStandard
Thermocouple typesK, T, J, E, S, N, B and PStandard
Range−200 to 1350 °CStandard
Accuracy±0.5% ±0.6 °CStandard
Scan interval1 to 99999 s, set to suit the process being watchedStandard
Cold junctionCompensated at the input terminals; the method is not described in the materialInformation required
Channel isolationChannels isolated from one another; the withstand value is not given in the materialInformation required
Display and alarms
Screen5 in full touchscreen, all channels shown togetherStandard
Alarm limitsUpper and lower limit set per channelStandard
Alarm indicationColour change on the channel and a buzzerStandard
MutingBuzzer can be silenced from the panelStandard
Data viewLive channel values with the channel tag; no curve or bar page is listedStandard
Interfaces and storage
USBFront-panel socket for a USB drive, supplied with the PC communication softwareStandard
SerialRS-232 or RS-485 to orderOptional
ProtocolMODBUS RTUStandard
SoftwareData acquisition software included as standardStandard
Electrical and environment
MainsAC 220 V ±10%; a 90 to 265 V supply can be selected, the wording of that option being incomplete in the materialInformation required
Live-circuit ratingAC 400 V and DC 600 V at the input; the test conditions are not statedInformation required
Operating temperature−20 to 70 °CStandard
Operating humidity20 to 90% relative humidityStandard
FuseRear fuse holder beside the mains inletStandard
Mechanical
Dimensions275 × 113 × 303 mm, measured by handStandard
WeightAbout 4 kgStandard
Input terminalsGreen thermocouple terminals on the rear panel, accepting a mating plug directlyStandard
Supplied accessoryThermocouple lead, listed for both models; the full packing list is not givenInformation required

Available models

Selection table
Model Configuration Key ranges Availability
HG-8 8 channels, 5 in touchscreen 8 channels; −200 to 1350 °C; K, T, J, E, S, N, B, P For a bench with a small number of points
HG-16 16 channels, 5 in touchscreen 16 channels; −200 to 1350 °C; K, T, J, E, S, N, B, P For a full fixture or a small chamber

Customization

  • RS-232 or RS-485 interface
  • 90 to 265 V mains supply
  • Thermocouple type and lead length by channel

Certification and compliance

Certification documents not yet supplied

Certifications are only published once a certificate copy can be produced, so this section is deliberately empty rather than populated with assumed approvals. Tell us which approvals your application requires and we will confirm what is available for this instrument.

Parameters still to be confirmed

The following are required for a complete specification but are not stated in the documentation supplied to us. They are listed rather than estimated:

  • Channel isolation withstand value, described only as isolated in the material
  • Cold-junction compensation method at the terminals
  • Test conditions for the AC 400 V and DC 600 V live-circuit rating
  • The 90 to 265 V supply option, whose description is cut off in the source
  • Whether every parameter except channel count is identical on the HG-16, since the parameter table names only the HG-8
  • Per-type accuracy, since one figure is given for all eight thermocouple types
  • Full packing list, of which only the thermocouple lead is named
  • Whether a curve or trend view exists, since only the numeric channel page is described
  • Calibration certificate availability
  • Warranty period and terms

Frequently asked questions

Is a scan interval of a day realistic for a temperature test?

Yes, for a process whose temperature moves over hours: a curing oven, a storage room, a tank that is heated once a day. At that interval the record shows the trend and not the detail, so it is the wrong setting for a heat-up curve or for catching a short excursion. The interval is set per scan, which means it applies to all channels at once, not to a single channel.

Can the scanner feed a control system rather than a USB drive?

With the optional serial interface, yes: RS-232 or RS-485 carrying MODBUS RTU. That lets a PLC or a supervisory system read the channels directly instead of a person collecting a drive. The interface is an option, not a standard fitting, so it has to be chosen when the scanner is ordered.

What has to be confirmed before a quotation?

The number of points, which fixes HG-8 or HG-16; the thermocouple types in use, including whether type P is needed; whether any probe sits on a live circuit and at what voltage; whether the data leaves by USB or over a serial link; and the ambient temperature where the instrument will stand, since its own operating range is limited.

Related products

Other models in the same range

Benchtop temperature recorder seen from the front, with a colour screen showing eight channels of readings in two rows, a USB socket at the left, a round power button below it and a speaker grille at the right

TCP-400 (4 models) · Temperature Recorders

Multi-Channel Temperature Recorder and Scanner

Benchtop multi-channel temperature recorder for 8 to 64 thermocouple inputs, with a colour touchscreen, per-channel correction, four-level alarms and USB logging.

Channels
8 to 64, added in blocks of eight
Thermocouple types
K, S, R, B, N, E, J, T; W5/26 on the XL, 500 and 700 series
Display accuracy
0.2% + 0.5 °C ±2 digits, thermocouple not included
Temperature range
−270 to 2310 °C as marked on most units; a second listing gives −200 to 1300 °C
Benchtop recorder with a wide colour screen showing a multi-channel trend plot and a row of page tabs, a USB socket at the left, a round power button beneath it and a vent grille on the right of the front panel

YP4000 (3 models) · Temperature Recorders

Paperless Multi-Channel Temperature Recorder

Touchscreen temperature recorder for 8 to 64 isolated inputs, with four-level alarms, internal storage that survives power loss and wireless viewing from a PC or phone.

Channels
8 to 64, by series
Scan interval
0.1 to 9999 s, adjustable, with three preset speeds
Accuracy
±0.2% ±2 digits, thermocouple excluded
Range
−200 to 1800 °C, sensor dependent
Multi-channel resistance scanner seen from the front, with a colour display showing eight channel readings in two columns, a keypad at the right and a four-terminal socket at the lower right

CXT2518-4 (5 models) · Electrical Test Equipment

Multi-Channel and Multi-Point Resistance Scanner

Bench scanners that step a four-wire measuring circuit through 2 to 64 channels, applying per-channel limits, in ranges from 1 µΩ to 2 MΩ and at up to 40 readings per second.

Channels
2 to 64 per instrument; 3 to 100 on one family, to order
Measurement
DC resistance, four terminals per channel
Resistance range
1 µΩ to 2 MΩ on the wide families; 10 µΩ to 200 kΩ on the common ones
Accuracy
0.05% typical; 0.02% on one family

Request a quotation for the HG-8

Send the configuration you need and we will confirm availability, lead time and terms. Minimum order quantity is 1 pc.

Request for quotation

Request a quotation - HG-8

Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.

The more of this you can give us, the fewer exchanges are needed before we can quote.
No file chosen
Datasheet, drawing, BOM or photograph. One file, up to 10 MB (PDF, Office, image or ZIP).

By submitting this form you agree that we may contact you about this enquiry. We do not sell or share enquiry data. See our privacy policy.

Items held in stock are dispatched within 48 hours of order confirmation. Customized specifications are produced to order and typically ship within 2 to 10 days. Transit time then depends on the shipping method and destination.

Request a Quote WhatsApp