Industrial Sensors · Proximity Sensors

Inductive Proximity Switch, M12

M12 inductive proximity switches for non-contact metal detection, in shielded 2 mm and unshielded 4 mm versions with NPN, PNP, two-wire DC and two-wire AC outputs.

LJ12A3 ·

Key specifications

Thread
M12×1
Sensing distance
2 mm ±10% shielded; 4 mm ±10% unshielded
Setting distance
0 to 1.6 mm shielded; 0 to 3.6 mm unshielded
Standard target
Iron, 12×12×1 mm shielded; 15×15×1 mm unshielded
Output forms
NPN, PNP, two-wire DC and two-wire AC
Output action
Normally open, normally closed, or normally open plus normally closed
Supply, DC
12 to 24 VDC nominal, 6 to 36 V range
Supply, AC
110 to 220 VAC nominal, 36 to 250 V range
Housing
Nickel-plated brass, with an ABS sensing face
Sealing
IP65

An inductive proximity switch detects a metal part without touching it. A coil in the sensing face generates an alternating field, a metal target entering that field absorbs energy from it, and the circuit that keeps the coil oscillating registers the change and operates its output. Nothing moves and nothing wears, which is why the switch is used for end-of-travel detection, counting and position sensing on machines where a mechanical limit switch would be replaced every few months.

The switches on this page are M12 threaded bodies in a nickel-plated brass housing with an ABS sensing face. Two sensing distances are offered: 2 mm on the shielded version, which can be mounted flush in metal, and 4 mm on the unshielded version, which must stand clear of it. Four output forms cover NPN, PNP, two-wire DC and two-wire AC, and the action can be normally open, normally closed or changeover.

Sealing is IP65 and the operating temperature range is -25 to +65°C. The DC versions run from 6 to 36 V, so one part covers both 12 V and 24 V control systems, and the AC versions run from 36 to 250 V.

How an inductive proximity switch works

The sensing face contains a coil that forms part of an oscillator, running at a frequency well above the switching rate of the output. When a metal target enters the field, eddy currents are induced in it and draw energy from the circuit. The oscillation amplitude falls, a detector circuit senses the change and operates the output. The switch point is set by how much energy the target absorbs, which is why the target material matters as much as the distance.

The two ratings that govern where the switch is mounted are the rated sensing distance and the setting distance. The rated distance is measured against a standard iron target of a defined size in a laboratory arrangement. The setting distance is the range over which the switch can be positioned in practice, and it is always smaller, because the surrounding metal, the supply voltage and the temperature all shift the operating point. The material supplied for these switches recommends mounting at 85% of the rated distance for that reason.

Shielded and unshielded versions differ in where the field goes. A shielded switch has a metal ring around the coil that concentrates the field in front of the face, so it can be buried in a metal surface without the surrounding metal damping it, at the cost of range. An unshielded switch has no such ring, so its field spreads and reaches further, but a metal surface beside the face will damp it and the switch will operate continuously.

How to select the right switch

Decide first how it will be mounted. A tapped hole in a metal bracket with the face flush calls for the shielded version. A position where the switch stands clear of surrounding metal can use the unshielded one and gain the longer distance. This choice is usually made by the machine design rather than by preference.

Then match the output to the control circuit. NPN suits a sinking input on a PLC or a controller; PNP suits a sourcing input. Two-wire DC is for a case where only two conductors are available in the existing wiring. Two-wire AC is for an existing AC control circuit, and its response frequency of 25 Hz is a limit worth noting: on a fast counting duty it will not keep up, whereas a DC version switches at 0.5 kHz.

Then check the load current. The output current differs by form, from 200 mA on the two-wire DC version to 400 mA on the AC version, and a load near that figure should be checked rather than assumed.

Finally set the position on the machine. The distance at which the switch actually operates depends on the target material, the surrounding metal and the supply, so the useful approach is to mount at a proportion of the rated distance and then adjust with the machine assembled rather than to set a nominal figure on the bench.

Limitations and points to confirm

An inductive switch only responds to metal. A plastic, glass, ceramic or wooden part passes through the field without being detected, and a non-metal target needs a capacitive or a photoelectric sensor instead. Where the target is metal but recessed behind a cover, detection through the cover works only while the total gap stays inside the sensing distance.

The published sensing distance is not the distance in service. The material gives stainless steel as switching at about 0.8 times the rated figure and brass at about 0.4 times, and it also recommends mounting at 85% of the rating. Those two effects multiply, so a brass target on a 4 mm switch operates nearer to 1.4 mm than to 4 mm. A mounting position taken from the catalogue figure alone is the usual reason a switch that worked on the bench fails to operate on the machine.

Two items in the supplied material are incomplete. The model table lists a three-wire AC form whose code repeats the two-wire AC code, so that form is named on this page with the discrepancy stated rather than left out. And the temperature effect on sensing is quoted twice with different tolerances depending on the range considered. Both are published as given rather than one being chosen.

The material also states that the mounting bracket is not supplied, so a bracket has to be provided by the machine builder. In a strong magnetic field, screened cable is recommended rather than the standard cable.

Features

  • Non-contact detection of a metal target, so there is no lever to wear and no force applied to the part being sensed
  • Shielded and unshielded versions at 2 mm and 4 mm, which allows the switch to be buried flush in a metal surface or mounted clear of it
  • Four output forms covering NPN, PNP and two-wire DC and AC, so the switch can be matched to a controller input or wired into an existing AC circuit
  • Normally open, normally closed and changeover action modes, so the logic can be set by the part ordered rather than by an external relay
  • Reverse-connection, surge and short-circuit protection on the three-wire forms
  • A nickel-plated brass body and an IP65 rating, for mounting on the machine rather than inside an enclosure
  • A 1.1 m stranded copper cable, which is long enough to reach a terminal box on most machine frames
  • Operation from 6 to 36 VDC, so the same DC part covers 12 V and 24 V control systems

Technical specifications

Every value below is taken from source documentation. Where a parameter is not stated in the available material it is marked as information required rather than estimated.

Sensing
Sensing distance, shielded2 mm ±10%Standard
Sensing distance, unshielded4 mm ±10%Standard
Setting distance, shielded0 to 1.6 mmStandard
Setting distance, unshielded0 to 3.6 mmStandard
Standard target, shieldedIron, 12×12×1 mmStandard
Standard target, unshieldedIron, 15×15×1 mmStandard
Hysteresis10% or less of the sensing distanceStandard
Target material effectStainless steel switches at about 0.8 times the rated distance and brass at about 0.4 timesStandard
Response frequency, DC0.5 kHzStandard
Response frequency, AC25 HzStandard
Mounting allowance85% of the rated sensing distance in service, to allow for temperature and voltageStandard
Electrical
Supply, DC12 to 24 VDC, 6 to 36 V range, ripple 10% peak-to-peak or lessStandard
Supply, AC110 to 220 VAC, 36 to 250 V range, 50/60 HzStandard
Current consumption, NPN and PNP13 mA or lessStandard
Current consumption, two-wire DC0.8 mA or lessStandard
Current consumption, two-wire AC1.7 mA or lessStandard
Output current, NPN and PNP300 mA or lessStandard
Output current, two-wire DC200 mA or lessStandard
Output current, two-wire AC400 mA or lessStandard
Protection, three-wire formsReverse connection, surge absorption and load short circuitStandard
Protection, AC formSurge absorptionStandard
Voltage effect on sensingWithin ±10% of the rated distance over ±15% of the rated supplyStandard
Insulation resistance50 MΩ or more at 500 VDC between the live parts and the housingStandard
Dielectric strengthAC 1,000 V at 50/60 Hz for 1 minute between the live parts and the housingStandard
IndicatorAction lamp on the rear of the bodyStandard
Cable1.1 m, stranded copperStandard
Environment and construction
Operating temperature-25 to +65°CStandard
Temperature effect on sensingWithin ±15% of the rated distance over the full range; within ±10% over -25 to +60°CInformation required
Humidity35 to 95 %RHStandard
Vibration10 to 55 Hz, 1.5 mm double amplitude, 2 hours in each of three axesStandard
Shock500 m/s², ten times in each of three axesStandard
SealingIP65Standard
HousingNickel-plated brass, with an ABS sensing faceStandard
Overall length62 mm on the 2 mm version, 60 mm on the 4 mm versionStandard
Body diameter21 mm overall, on an M12×1 threadStandard
Supplied fittingsTwo nuts and two toothed washersStandard
Mounting bracketNot suppliedOptional
Three-wire AC modelThe model table lists a row for this form with a code that repeats the two-wire AC code; the form is not fully specifiedInformation required

Available models

Selection table
Model Configuration Key ranges Availability
LJ12A3-2-Z/BX and LJ12A3-4-Z/BX NPN, normally open 2 mm shielded or 4 mm unshielded; 6 to 36 VDC; 300 mA Three-wire
LJ12A3-2-Z/AX and LJ12A3-4-Z/AX NPN, normally closed 2 mm shielded or 4 mm unshielded; 6 to 36 VDC; 300 mA Three-wire
LJ12A3-2-Z/BY and LJ12A3-4-Z/BY PNP, normally open 2 mm shielded or 4 mm unshielded; 6 to 36 VDC; 300 mA Three-wire
LJ12A3-2-Z/AY and LJ12A3-4-Z/AY PNP, normally closed 2 mm shielded or 4 mm unshielded; 6 to 36 VDC; 300 mA Three-wire
LJ12A3-2-Z/CX and LJ12A3-4-Z/CX NPN, normally open plus normally closed 2 mm shielded or 4 mm unshielded Changeover action
LJ12A3-2-Z/EX and LJ12A3-4-Z/EX Two-wire DC, normally open 2 mm shielded or 4 mm unshielded; 6 to 36 VDC; 200 mA Two-wire
LJ12A3-2-Z/DX and LJ12A3-4-Z/DX Two-wire DC, normally closed 2 mm shielded or 4 mm unshielded; 6 to 36 VDC; 200 mA Two-wire
LJ12A3-2-J/EZ and LJ12A3-4-J/EZ Two-wire AC, normally open 2 mm shielded or 4 mm unshielded; 36 to 250 VAC; 400 mA Response frequency 25 Hz
LJ12A3-2-J/DZ and LJ12A3-4-J/DZ Two-wire AC, normally closed 2 mm shielded or 4 mm unshielded; 36 to 250 VAC; 400 mA Response frequency 25 Hz

Certification and compliance

Certification documents not yet supplied

Certifications are only published once a certificate copy can be produced, so this section is deliberately empty rather than populated with assumed approvals. Tell us which approvals your application requires and we will confirm what is available for this instrument.

Parameters still to be confirmed

The following are required for a complete specification but are not stated in the documentation supplied to us. They are listed rather than estimated:

  • Full specification of the three-wire AC form, whose model code repeats the two-wire AC code in the supplied table
  • Which temperature effect figure applies in service, since two ranges are given with different tolerances
  • Sensing distance derating factors for target materials other than iron, stainless steel and brass
  • Whether the output action can be changed on site or is fixed at order
  • Certification list and availability of certificate copies
  • Warranty period and the terms that apply
  • English-language datasheet and wiring diagram in PDF form
  • Packaging dimensions and gross weight for freight calculation
  • Recommended mounting torque for the M12 thread
  • Cable conductor cross-section

Frequently asked questions

Shielded or unshielded — what decides it?

How the switch is mounted decides it. A shielded switch can be buried in metal so that its sensing face is flush with the surrounding surface, which is what an installation on a machine frame normally needs. An unshielded switch must have its sensing face clear of any surrounding metal by a distance, and in exchange it senses further: 4 mm against 2 mm on this series. If the mounting position is a tapped hole in a metal bracket, the shielded version is the one to take, and the shorter distance is the price of not having to machine a clearance around the face.

Why does the sensing distance not match the rated figure in service?

Two reasons, and both are stated in the supplied material. The rated distance is measured against a standard iron target, and a different material switches at a different distance: stainless steel at about 0.8 times the figure and brass at about 0.4 times. And the material recommends mounting at 85% of the rated distance to allow for the effect of temperature and supply voltage. A 4 mm switch on a brass target is therefore closer to a 1.6 mm switch, so the mounting position should be set from the target material and not from the catalogue figure alone.

Which output form suits which controller?

An NPN output switches the load to the negative supply and suits a sinking input; a PNP output switches to the positive supply and suits a sourcing input. A two-wire DC form is wired in series with the load and suits a relay or a controller input where only two conductors are available. The two-wire AC form suits a circuit that is already AC, such as a lamp or a contactor coil on a 110 or 220 V control circuit. The output current differs between the forms, from 200 mA on the two-wire DC version up to 400 mA on the AC version, so a load near the limit should be checked against the form being ordered.

What does the switch need in the way of mounting hardware?

The switch is supplied with two nuts and two toothed washers, which is what is needed to set the position in a threaded hole and lock it. The mounting bracket is not included, so a bracket has to be provided or ordered separately. When the switch is set up, the position should be adjusted on the machine rather than set to the nominal distance on the bench, because the target material and the surrounding metal both affect where the switch actually operates.

Can the switch be used on a non-metal target?

No. An inductive switch responds to the eddy currents a metal target induces in its field, so a plastic, glass or wooden part passes without being detected. A metal part behind a plastic cover is detected through the cover provided the total gap is inside the sensing distance. For a non-metal target, a capacitive or a photoelectric sensor is the type to use rather than an inductive one.

Request a quotation for the LJ12A3

Send the configuration you need and we will confirm availability, lead time and terms. Minimum order quantity is 1 pc.

Request for quotation

Request a quotation - LJ12A3

Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.

The more of this you can give us, the fewer exchanges are needed before we can quote.
No file chosen
Datasheet, drawing, BOM or photograph. One file, up to 10 MB (PDF, Office, image or ZIP).

By submitting this form you agree that we may contact you about this enquiry. We do not sell or share enquiry data. See our privacy policy.

Items held in stock are dispatched within 48 hours of order confirmation. Customized specifications are produced to order and typically ship within 2 to 10 days. Transit time then depends on the shipping method and destination.

Request a Quote WhatsApp