A coating thickness gauge measures the depth of a layer sitting above a substrate, without cutting through it. Paint on steel, zinc on steel, anodising on aluminium, copper on a board and a plastic film on a metal sheet are all the same measurement problem: a non-magnetic or non-conductive layer, a solid substrate beneath it, and a figure that has to be shown to be inside a tolerance. It is one of the few coating checks that is non-destructive, which is why it is taken on the delivered part and not only on a coupon.

What a coating thickness gauge is

A coating thickness gauge measures the depth of a layer sitting above a substrate, without cutting through it. Paint on steel, zinc on steel, anodising on aluminium, copper on a board and a plastic film on a metal sheet are all the same measurement problem: a non-magnetic or non-conductive layer, a solid substrate beneath it, and a figure that has to be shown to be inside a tolerance. It is one of the few coating checks that is non-destructive, which is why it is taken on the delivered part and not only on a coupon.

The method is decided by the substrate, not by the coating. A magnetic induction probe works on ferromagnetic steel and iron and reads how far the coating pushes the probe away from the substrate; an eddy current probe works on non-ferrous metals such as aluminium, copper and austenitic stainless steel and reads the effect the coating has on an induced field. A gauge that carries both can switch between them and identify the probe in use, but the reading is always a reading for one method, and the two are not interchangeable on the same substrate.

What limits the measurement is mostly geometry. Curvature, the proximity of an edge, and a substrate thinner than the method needs all distort the field and bias the reading, and each has a published limit attached to the probe. Above those limits the error grows quietly, so the practical task is to match the probe range to the expected thickness and then to check that the part satisfies the probe conditions before trusting the number.

How a coating thickness gauge measures

A magnetic induction gauge energises a coil in the probe and measures the reluctance of the path between the probe and the ferromagnetic substrate. The coating is a gap in that path, so the reading is essentially a distance measurement across the layer, which is why the method depends on the substrate being genuinely ferromagnetic and on the coating being genuinely non-magnetic. Nickel plating and some stainless steels break that assumption, and the gauge reads them as substrate rather than as coating.

An eddy current gauge drives an alternating field into a conductive substrate and measures the change in impedance caused by eddy currents flowing in it. Because the field is affected by the standoff, the same coil geometry becomes a thickness reading when the substrate is known. It is the method for aluminium, copper, brass and 300-series stainless steel, where a magnetic gauge would read nothing useful at all.

Both methods are relative measurements and are calibrated rather than absolute. Zeroing on the bare substrate establishes the datum, and one or two foils of known thickness establish the slope, with the two-point form correcting the gain as well as the offset. Almost every surprising reading traces back to that setup: zeroing on a coated area, using a foil outside the probe range, or leaving the calibration untouched when the probe is changed. The physical conditions - curvature, edge distance, substrate thickness, temperature - are the second half of the same story, and the instrument cannot correct for them on its own.

Configuration choices

Most of the specification is fixed by these decisions rather than by the accuracy class. Each one constrains the next, which is why they are settled in order.

ConfigurationOptions to fixWhat it actually decides
Measuring method Magnetic induction, eddy current, or a gauge carrying both and identifying the probe automaticallyWhether the intended substrate can be measured at all. The method follows the substrate material, not the coating.
Probe range A short-range probe for thin coatings, a long-range probe for thick ones, and the resolution each offersThe thickness band that can be read with useful resolution. A probe stretched to the end of its range loses both accuracy and repeatability.
Probe format A probe built into the housing, or a separate probe on a cableWhether the instrument can reach the surface. An integral probe cannot be laid flat on a curved or recessed area.
Probe geometry The tip form and the minimum measurement area the probe needsWhether small parts, narrow areas near an edge, or tight curvature can be measured without a correction that the instrument does not know about.
Calibration method One-point zeroing, two-point calibration against foils, or the factory setting left untouchedHow much of the reading error is removed. Zeroing alone corrects the offset and leaves the gain uncorrected.
Data handling Direct display, internal memory with statistics, and export to a host or a printerWhether a batch record with mean, minimum, maximum and standard deviation can be produced, which acceptance criteria increasingly require.
Limits and alarms Settable upper and lower limits with an audible or visual indicationWhether the instrument can be used for screening by an operator who is not reading the numbers, and what tolerance the limits can express.
Verification Reference foils, reference substrates of known thickness, and the interval at which they are usedWhether the gauge can be shown to be reading correctly on the day, which is what a quality record has to demonstrate.

How to choose a coating thickness gauge

FactorWhy it decides the answerHow to settle it before enquiring
The substrate material It selects the method, and a magnetic gauge reads nothing useful on aluminium while an eddy current gauge reads nothing useful on carbon steelState the substrate exactly, including the grade, because some stainless steels and nickel layers behave as the opposite of what their name suggests.
The expected coating thickness and its tolerance The probe range and its resolution have to bracket the tolerance, not merely the nominal figureGive the target thickness and the tolerance band, and the process that produces it.
Whether the coating may be magnetic Nickel and some alloy coatings defeat a magnetic induction gauge by acting as part of the substrateState the coating material and its deposition method, not only its name.
The geometry of the part Curvature, edges and small areas all bias the field, and each probe has published limits beyond which the reading is not validGive the smallest radius, the distance from the nearest edge, and the smallest area to be measured.
Substrate thickness Below a critical thickness the substrate stops behaving as an infinite body and the reading fallsGive the substrate thickness, and whether the part is a sheet or a heavy section.
Whether results must be recorded A batch record with statistics changes the instrument class, and often the way the readings are takenState the acceptance criteria, how many readings per part, and in what form the record is required.

If any of these are still open, send what is known. A quotation can be issued against a described part and refined once the gaps are filled.

The nearest alternatives

These are the types an enquiry for a coating thickness gauge usually turns out to be, and the point at which the choice is genuinely decided.

Nearest alternativeWhat separates it from a coating thickness gauge
Surface roughness testers Measures the texture of the outermost surface rather than the depth of the layer beneath it. A coated part often carries both requirements, and the two are measured separately because a smooth coating can still be too thin and a thick one can still be rough.
Hardness testers Measures resistance to indentation in the material, which for a coated part is usually a question about the substrate rather than about the layer. It presses into the surface, so it is not a substitute where the coating must remain intact.
Ultrasonic thickness gauges Measures the thickness of the material itself, and can be set to resolve a coating as one of two echoes on some instruments. That is a wall-thickness instrument answering a remaining-life question; a coating gauge answers a finish and corrosion-protection question.
Magnetic particle testing equipment Also uses a magnetic field on ferromagnetic parts, but looks for cracks rather than for layer depth. Sharing a physical principle is not the same as sharing a purpose, and neither instrument reports what the other does.
Eddy current flaw detectors Use the same induced-field principle to find discontinuities in conductive material rather than to measure a layer above it. Some instruments combine both functions, and where they do, the two modes are calibrated separately.
Destructive coating examination A microscope measurement of a cut section, or a chemical strip-and-weigh. Slower and it consumes the sample, but it is the reference method where a dispute arises, and it is worth keeping a coupon for exactly that reason.

Roughness, hardness and coating thickness are the three surface requirements a drawing most often names together; a coating gauge answers only the last of them, and the three are measured with three different instruments.

What to include in the enquiry

The first reply can be a quotation rather than a set of questions if the enquiry carries these. Where a figure is not known, send the duty description and we will confirm what it implies.

  1. The substrate material and grade, and its thickness
  2. The coating material and how it is applied
  3. The expected coating thickness, with its tolerance band
  4. The geometry of the part, including the smallest radius, the nearest edge and the smallest measurement area
  5. Whether the coating may be magnetic, and whether any nickel or alloy layer is present
  6. Whether the coating is on one side or both, and whether the reverse face is accessible
  7. Whether readings must be stored and exported, and in what form the record is required
  8. The acceptance criteria and the number of readings per part
  9. Reference foils or reference substrates available locally for verification
  10. Quantity, destination port and required delivery date

Available products

3 models in Coating Thickness Gauges

Handheld coating thickness gauge with a light grey front panel, a display showing a thickness reading above four statistics columns and a substrate indicator, and four round keys beneath the screen

LS225 (4 models) · Coating Thickness Gauges

High-Precision Coating Thickness Gauge

Coating thickness gauge with interchangeable magnetic and eddy current probes, five-point calibration and an accuracy of ±(2% of reading + 0.3 µm) for plating and paint on small parts.

Measuring range
0.0 to 500 µm with F500; 0.0 to 1500 µm with N1500; 0.0 to 2000 µm with N2000
Accuracy
±(2% H + 0.3 µm) after five-point calibration, H being the standard value
Repeatability
≤ (0.8% H + 0.1 µm) on F500 and N1500 with the hand press stand; ≤ ±(1% H + 0.2 µm) on N2000
Probes
F500 magnetic induction; N1500 and N2000 eddy current
Yellow handheld coating thickness gauge with a red backlit display in a dark bezel, a single round key below the screen and a narrow probe barrel at the lower end

LS238 (5 models) · Coating Thickness Gauges

Handheld Automotive Paint Thickness Gauge

Handheld paint thickness gauge with a 3500 µm range, automatic recognition of steel, galvanised steel, aluminium and plastic substrates, and a putty detection warning for used-car inspection.

Measuring range
0.0 to 3500 µm
Resolution
0.1 µm from 0 to 99.9 µm; 1 µm from 100 to 3500 µm
Accuracy
≤ ±(3% H + 2 µm), where H is the standard value
Substrates
Ferrous by Hall effect; non-ferrous by eddy current; identified automatically
Split-probe coating thickness gauge in a black housing with a cable entering the top, a backlit display reading 49.4 um above a line showing the probe type and single measurement mode, and a twelve-key control pad below with eight keys grouped in coloured pairs and a round key in the centre

TT220 (3 models) · Coating Thickness Gauges

Dual-Principle Coating Thickness Gauge

Magnetic and eddy current coating thickness gauge measuring 0 to 1250 µm on steel and aluminium, with automatic probe identification, statistics, limit alarms and 500 stored readings.

Model
TT220 / TT230 / TT260 and the split-probe F and N series
Measuring principle
Magnetic induction on ferromagnetic substrates, eddy current on non-ferrous substrates, selected automatically by the probe fitted
Measuring range
0 to 1250 µm with the standard F1 or N1 probe; 0 to 400 µm with F400; 0 to 5000 µm with F5; 0 to 10000 µm with F10; 0 to 2000 µm on the integral TT220
Resolution
0.1 µm below 100 µm; 10 µm on the long-range F10 probe; 1 µm above 100 µm on the integral model

Also in Industrial Testing Equipment

Other product types in this category

Every type we quote for under Industrial Testing Equipment. A type with no link yet is still quoted for - it is described on the Industrial Testing Equipment overview, and gets a page of its own as soon as a model is published against it.

Frequently asked

Coating Thickness Gauges questions

Why does the gauge read zero on a painted steel part?

Because the probe is not seeing the steel. A magnetic induction gauge reads the stored value against a ferromagnetic substrate, and a nickel layer, a thick non-ferrous intermediate layer or a substrate that is not actually ferromagnetic will present a path the probe reads as though the coating were not there. The other common cause is a calibration that was zeroed on a coated area rather than on bare substrate, which shifts every subsequent reading by the thickness of that area. Both are corrected before the instrument is blamed.

Do I need one method or two?

It depends on what will be measured over the life of the instrument. If every part is carbon steel, a magnetic induction gauge is sufficient and simpler. If aluminium, copper or stainless steel parts are also inspected, an eddy current probe is required as well, and a gauge that carries both and identifies the probe automatically avoids the mistake of using the wrong one. Buying both in one instrument costs less than buying one method twice.

How close to an edge or how small a part can be measured?

Each probe has a published minimum measurement area and a minimum distance from an edge, and the field is distorted inside those distances. The distortion does not announce itself - the number simply drifts - so the practical approach is to state the smallest area and the nearest edge in the enquiry and let the probe be chosen around them. For very small or very curved features, a probe with a smaller tip is the answer rather than a correction factor applied afterwards.

What has to be sent for a quotation?

The substrate material and grade, its thickness, the coating material and the process that applies it, the expected thickness with its tolerance, and the geometry of the part including the smallest radius and the closest edge. State whether any layer is magnetic, because that decides whether a magnetic method is usable. If the coating specification is still being settled, send what is known - a quotation can be issued against the described part and adjusted once the tolerance is fixed.

Quoting for Coating Thickness Gauges

Send the specification and we will confirm the matching model, availability and lead time. Minimum order quantity is 1 pc.

Request for quotation

Request a quotation - Coating Thickness Gauges

Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.

The more of this you can give us, the fewer exchanges are needed before we can quote.
No file chosen
Datasheet, drawing, BOM or photograph. One file, up to 10 MB (PDF, Office, image or ZIP).

By submitting this form you agree that we may contact you about this enquiry. We do not sell or share enquiry data. See our privacy policy.

Items held in stock are dispatched within 48 hours of order confirmation. Customized specifications are produced to order and typically ship within 2 to 10 days. Transit time then depends on the shipping method and destination.

Request a Quote WhatsApp