Industrial Automation & Control · PID Controllers

Panel-Mount PID Temperature Controller

Panel-mount PID temperature controllers in four panel sizes, taking thermocouple, RTD, 4-20 mA or 0-10 V inputs and driving relay, SSR, linear and RS-485 outputs.

Key specifications

Panel sizes
48×48, 48×96, 72×72, 96×96 mm
Input types
K, E, J, R, S, B, N, T, PT, CU; 4-20 mA; 0-10 V
Default input
Type K, changeable in the menu
Output forms
Relay, SSR drive, PID 4-20 mA or 0-10 V, linear 0-10 V or 4-20 mA
Alarm outputs
One or two, depending on the alarm code ordered
Relay contact rating
250 VAC, 3 A / 5 A
Instrument depth
71 mm
Communication
RS-485, on the communication option
Weight
0.120 / 0.170 / 0.235 kg, by size code

A panel-mount PID temperature controller reads a temperature sensor, compares the reading against a setpoint and drives a heating or cooling output to close the gap. It is the instrument that holds a process at temperature, which is why it appears on extruders, injection moulding machines, packaging lines, ovens, baths and environmental chambers rather than only on test benches.

The controllers on this page cover four panel sizes from 48×48 to 96×96 mm. Inputs cover ten thermocouple and RTD types plus 4-20 mA and 0-10 V, selected in the instrument menu rather than fixed at order. Outputs cover relay contacts, SSR drive, a PID current or voltage output and a linear transmit output, and some of those combine where the panel size allows.

The configuration is ordered as a code built from five positions. The size code sets the panel cut-out, the output code sets the switching form, the alarm code sets one or two alarm channels, and a trailing letter adds RS-485. Because the output position is one digit on some options and two on others, the code length changes with the configuration.

How a PID temperature controller works

The controller runs a control loop rather than a thermostat. A relay-only controller switches the heater fully on until the setpoint is reached and then fully off, which overshoots and then undershoots around the setpoint. A PID loop measures how far the process is from the setpoint, how long it has been away from it, and how fast it is moving, and adjusts the output proportionally rather than in steps. On the same heater, the PID loop settles closer to the setpoint and holds it there.

The output form decides how that adjustment reaches the load. A relay output can only switch, so the loop works by varying how long the relay stays closed within a cycle. An SSR drive switches solid-state, which allows the same proportioning at a much shorter cycle. A linear 4-20 mA or 0-10 V output drives a power controller or a valve rather than switching the load directly, and it is the form that suits a load too large for a contact.

Input type is a menu setting, not a hardware choice. A controller set for a type K thermocouple will read a plausible and wrong value from a PT100 on the same terminals, because the instrument is linearising the signal against the wrong curve. The input type is therefore part of the commissioning, not part of the order alone.

How to select the right controller

Start with the panel cut-out. It is usually already fixed by the enclosure, and on this series it also decides what is available: the 48×48 size carries either an SSR drive or a relay, not both, so a machine that needs a linear transmit output and a contact together cannot use that size.

Then settle the output from the load. A contactor or a solenoid valve suits a relay output. A solid-state relay or a thyristor unit suits an SSR drive, which switches faster and has no contact to wear. A power controller or a control valve suits a linear output, and a load that must also be recorded or fed to a plc suits a linear transmit output alongside the switching one.

Then the sensor and the alarms. Ten thermocouple and RTD types are covered, plus 4-20 mA and 0-10 V for a sensor that is already conditioned. Two alarm channels are available on the higher alarm code. Where the alarm is there to catch a failed heater rather than a high reading, the heater-break type is the one to specify, and it needs its two parameters set to suit the process before it can be relied on.

State the cut-out, the sensor type, the output form, the number of alarm channels and whether RS-485 is needed, and the code follows from those.

Limitations and points to confirm

This instrument is a controller, not a transmitter. It does not provide an isolated retransmission of the measured value unless the linear transmit output is ordered, and it does not record. A process that needs a documented temperature record needs a data logger or a recorder in addition.

The relay rating published here is a contact rating of 250 VAC at 3 A or 5 A, given as a single figure without being tied to a particular panel size or output code. A contact rating is not a load rating: an inductive load such as a solenoid or a motor draws a surge on break that a resistive load of the same nominal current does not, and the usual practice is to switch such a load through an interposing relay rather than directly from the controller.

Several figures that a specification often calls for are not in the supplied material at all, and they are listed on this page as information required rather than estimated: ingress protection, operating temperature and humidity, measurement accuracy, sampling period and dielectric strength. The alarm table in the supplied drawing also omits setting values 9 and 10, so those two are published as unknown.

Finally, the controller shown in the photograph carries a different reference from the series code given in the supplied document. Until that is resolved, treat the identification as open and quote the configuration you need rather than a code, so the two can be matched before the order is placed.

Features

  • Four panel sizes from 48×48 to 96×96 mm, so a panel layout can be filled from one series rather than from several suppliers
  • Ten thermocouple and RTD input types plus 4-20 mA and 0-10 V, selected in the instrument menu rather than at order
  • Relay, SSR, PID current or voltage and linear transmit outputs, combinable where the panel size allows
  • Sixteen alarm types including deviation, absolute, band, timer end and heater-break, with a standby variant of most of them
  • Four PID parameter menu levels (P-1 to P-4), so the loop can be tuned without entering a deeper engineering menu
  • RS-485 communication on the T option, for connection to a host or a supervisory system
  • A relay or an SSR drive in the 48×48 size, which suits machines where panel space is the constraint

Technical specifications

Every value below is taken from source documentation. Where a parameter is not stated in the available material it is marked as information required rather than estimated.

Input
Thermocouple and RTD typesK, E, J, R, S, B, N, T, PT, CUStandard
Default input typeType K, set in the instrument menuStandard
Analogue input4-20 mA (code A) or 0-10 V (code V)Standard
Input type changesMade in the parameter menu; the display reads incorrectly until the type matches the sensor fittedStandard
Output
RelayCode 1; contact rating 250 VAC 3 A / 5 AStandard
SSR driveCode 2Standard
Relay plus SSRCode 12Standard
PID 4-20 mA plus SSRCode 3Standard
PID 0-10 V plus SSRCode 4Standard
Linear transmit 0-10 V plus SSRCode 5Standard
Linear transmit 4-20 mA plus SSRCode 6Standard
Linear 0-10 V, SSR and relayCode 15; not available in the 48×48 sizeStandard
Linear 4-20 mA, SSR and relayCode 16; not available in the 48×48 sizeStandard
Output and alarm combination in 48×48Either an SSR or a relay, not bothInformation required
Contact rating per panel sizeInformation required; the document gives one rating without tying it to a size or output codeInformation required
Alarm
Alarm channelsCode 20 for one, code 24 for twoStandard
Alarm types availableNo alarm, deviation high and low, band in and band out, absolute high and low, heater break (LBAT), timer end, and the six standby variants of the deviation and absolute typesStandard
Setting values absent from the documentValues 9 and 10 are missing from the supplied alarm table; their behaviour is unknownInformation required
Panel and environment
Panel cut-out48×48, 48×96, 72×72 or 96×96 mm by size codeStandard
Instrument depth71 mmStandard
MountingPanel mount, with the display and keys on the front faceStandard
Ingress protectionInformation requiredInformation required
Operating temperature and humidityInformation requiredInformation required
Measurement accuracy and sampling periodInformation requiredInformation required
Dielectric strengthInformation requiredInformation required
2026-11 supply batch
ScopeAdditional forms supplied in November 2026 for this product type. Figures below are from that batch; where they differ from the rows above, both are recorded rather than merged.Standard
InputPT100 and K type thermocoupleStandard
OutputRelay contacts and 4-20 mAStandard
Accuracy0.5 classStandard
Supply220 V ACStandard

Available models

Selection table
Model Configuration Key ranges Availability
48×48 mm Size code A Relay or SSR drive only; output codes 15 and 16 are not available One output form only, because the case cannot carry both
48×96 mm Size code B Full output code range Vertical format
72×72 mm Size code D Full output code range
96×96 mm Size code E Full output code range Largest of the four sizes

Certification and compliance

Certification documents not yet supplied

Certifications are only published once a certificate copy can be produced, so this section is deliberately empty rather than populated with assumed approvals. Tell us which approvals your application requires and we will confirm what is available for this instrument.

Parameters still to be confirmed

The following are required for a complete specification but are not stated in the documentation supplied to us. They are listed rather than estimated:

  • Official model designation for the controller shown (the panel photograph and the supplied document give different codes)
  • Which reference the panel code belongs to, and whether both belong to the same instrument
  • Relay contact rating that applies to each panel size and output code
  • Behaviour of alarm setting values 9 and 10, which are absent from the supplied alarm table
  • Ingress protection of the front face and of the case
  • Operating temperature and humidity range
  • Measurement accuracy and sampling period
  • Dielectric strength
  • Certification list and availability of certificate copies
  • Warranty period and the terms that apply
  • English-language datasheet and manual in PDF form
  • Packaging dimensions and gross weight for freight calculation

Frequently asked questions

How is the model code built, and what has to be stated at order?

The code is built from five positions: a size code, an input index, an output code, an alarm code and an optional communication letter. The size code sets the panel cut-out. The output code selects relay, SSR drive, PID current or voltage, linear transmit, or a combination of these. The alarm code sets one or two alarm channels. The letter T at the end adds RS-485. Because the output position is one digit on some options and two on others, the code length changes with the configuration, so quote the whole string rather than a shortened form.

Can the 48×48 size take the same output configuration as the larger ones?

No. The supplied drawing states that the 48×48 size can carry either an SSR drive or a relay, not both, which is why output codes 15 and 16 are not available in that size. If the application needs a linear transmit output and a relay together, the next size up is the one to order. Raising this before the order is what avoids a panel that has to be re-cut.

Do the alarm types cover a heater that fails open circuit?

Yes, one of the alarm types is a heater-break alarm. It works from two parameters together, a time window and a change in the measured value, rather than from the reading crossing a threshold, so both have to be set to suit the process. An alarm of this kind set with parameters that do not match the process either fails to operate or operates on every cycle, so it is worth commissioning it deliberately rather than accepting the defaults.

What is needed before a quotation can be given?

State the panel cut-out, the sensor type being connected, the output form needed for the load, how many alarm channels are required, and whether RS-485 is needed. If the load is inductive, say so as well: the relay rating published here is a contact rating, and an inductive load is normally switched through an interposing relay rather than directly.

Is the accuracy of the controller published?

No. The supplied document does not state measurement accuracy, sampling period, dielectric strength, ingress protection or the operating temperature and humidity range, so none of those figures appear on this page. If a tolerance has to be demonstrated against a specification, tell us the figure required and we will confirm what the manufacturer publishes before quoting.

Request a quotation

Send the configuration you need and we will confirm availability, lead time and terms. Minimum order quantity is 1 pc.

Request for quotation

Request a quotation - Panel-Mount PID Temperature Controller

Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.

The more of this you can give us, the fewer exchanges are needed before we can quote.
No file chosen
Datasheet, drawing, BOM or photograph. One file, up to 10 MB (PDF, Office, image or ZIP).

By submitting this form you agree that we may contact you about this enquiry. We do not sell or share enquiry data. See our privacy policy.

Items held in stock are dispatched within 48 hours of order confirmation. Customized specifications are produced to order and typically ship within 2 to 10 days. Transit time then depends on the shipping method and destination.

Request a Quote WhatsApp