Pressure Measurement · Differential Pressure Transmitters

Differential Pressure Transmitter

A differential pressure transmitter from 0-1 kPa to 0-10 MPa, with 0.075 to 0.5 class accuracy, 4-20 mA with HART or RS-485, single and double flange forms, and 316L, Hastelloy or tantalum diaphragms.

Key specifications

Range
0-1 kPa to 0-10 MPa, with 0-3000 Pa, 0-30 kPa and 0-100 kPa as the low spans
Accuracy
0.075, 0.1, 0.2 or 0.5 class depending on the form
Output
4-20 mA with HART, or RS-485; 0-10 V on the micro-differential form
Supply
24 V DC as standard, 9-32 V DC on the transmitter shown
Process connection
Flanged DN50 or DN80, with NPT 1/4 on the micro-differential form
Diaphragm
316L stainless, Hastelloy or tantalum
Display
LCD with a 0-100 % scale
Ingress protection
IP67, with IP65 versions

Most pressure instruments measure one pressure. A differential transmitter measures two and reports the difference, which is why it appears wherever the difference carries the meaning: flow across an orifice, level in a tank, the pressure drop across a filter, the draught in a furnace.

That also makes it the instrument that is most often quoted wrongly. The range and the static pressure are separate figures, and a cell chosen for a small difference can still be destroyed by the line pressure it sits on.

Product overview

The instrument has two pressure sides separated by a diaphragm. The material covers spans from 0-1 kPa to 0-10 MPa, with 0-3000 Pa, 0-30 kPa, 0-100 kPa and 0-10 MPa named as common ones, and offers 0.075, 0.1, 0.2 and 0.5 class accuracy.

The output is 4-20 mA with HART as the common form, with RS-485 on the communication form and 0-10 V on the micro-differential form. The enclosure is IP67 on the main form, and the transmitter shown carries a nameplate marked 9-32 V DC supply, 4-20 mA/HART output and an ambient range of -20 to 85 °C.

How a differential pressure transmitter works

A diaphragm separates the high and low sides. The pressure difference deflects it, and the deflection is converted into an electrical signal proportional to that difference. Because the diaphragm sees both pressures, the static pressure on the line acts on both sides at once and largely cancels; what remains is the difference.

Three consequences follow. The instrument needs two process connections, not one, and the piping that brings them has to be arranged so that both legs see the same static head — which is what a manifold and a pair of impulse lines are for. A blocked or partly filled leg becomes a measurement error rather than a fault, because the transmitter keeps reading a plausible difference. And the diaphragm is the only part in contact with the medium, so its material decides what the instrument can survive.

How to select the right transmitter

What the difference is used for. Flow across an orifice, level in a tank and pressure drop across a filter all use the same instrument but are specified differently. The first needs a span matched to the calculated differential; the second needs the static head of the vessel accounted for; the third needs a low span and a connection that will not block.

Range and static pressure, separately. The differential range is what the instrument measures; the static pressure is what it sits on. A 0-1 kPa cell on a 4 MPa line is a different order from the same cell on a duct.

Single flange, double flange or remote seal. A single flange suits a pipe. A double flange with two capillaries suits level in a closed tank, because the second seal puts the vessel head on the low side so that it cancels. A remote seal is used where the medium is hot, viscous or corrosive enough that it should not reach the transmitter body.

Diaphragm material. 316L stainless covers most duties; Hastelloy and tantalum are for media that would attack it. This is the choice that decides whether the instrument lasts, and it is best settled with the medium list rather than after the order.

Installation and configuration

The transmitter is bolted to the process by its flange, or by an NPT 1/4 port on the micro-differential form. The impulse lines, the manifold and the orientation matter more than the instrument: air trapped in a liquid leg and condensate in a gas leg both produce a steady offset that looks like a real reading.

The zero is set with the keys beside the display, with both sides vented or equalised. The material gives no installation torque, no straight-run requirement and no impulse-line diameter, and none is invented here.

Measurement limitations and selection considerations

The first limitation is that both legs must be sound. A differential transmitter does not fail when a leg blocks; it keeps reading, and the error appears as a slow disagreement with a total taken elsewhere.

The second is the low end. A cell built for megapascals cannot resolve a few hundred pascals, which is why the material offers a separate micro-differential form with a 0-3000 Pa span and a 0-10 V output rather than extending the main range downwards.

Several figures are unsettled and are listed as information required rather than filled in: the static pressure rating, the temperature effect, the fill fluid, the seal material and the flange standard. The flange standard is the one that most often delays an order, because the drilling has to match the line that is already there.

Features

  • A 0.075 class form for a measurement that is used as a reference rather than as an indication, alongside 0.1, 0.2 and 0.5 class forms for ordinary duties
  • Single-flange, double-flange and remote-diaphragm forms, so a transmitter can be mounted away from a line that is hot, corrosive or difficult to reach
  • 4-20 mA with HART as the common output, with RS-485 on the communication form and 0-10 V on the micro-differential form
  • Diaphragms in 316L stainless, Hastelloy and tantalum, which is where the medium compatibility of the whole instrument is decided
  • An LCD showing the output in mA against a 0-100 % scale, so the loop current can be read at the transmitter before a meter is connected
  • IP67 sealing on the enclosure

Technical specifications

Every value below is taken from source documentation. Where a parameter is not stated in the available material it is marked as information required rather than estimated.

Measurement
Range0-1 kPa to 0-10 MPa across the range; 0-3000 Pa, 0-30 kPa, 0-100 kPa and 0-10 MPa are the spans named in the materialStandard
Accuracy0.075, 0.1, 0.2 and 0.5 class all appear, with plus or minus 0.03 %, 0.15 % and 0.2 % of span on individual listingsStandard
Static pressureNot stated in the materialInformation required
Temperature effectNot stated in the materialInformation required
Long-term stabilityNot stated in the materialInformation required
Response timeNot stated in the materialInformation required
Output and supply
Output4-20 mA with HART as the common form, RS-485 on the communication form, and 0-10 V on the micro-differential formStandard
Supply24 V DC as standard; the transmitter shown is marked 9-32 V DC; 220 V AC appears on some listingsStandard
DisplayLCD showing the output in mA against a 0-100 % scaleStandard
Zero and span adjustmentKeys beside the display on the transmitter shownStandard
Wetted parts
Diaphragm316L stainless steel, Hastelloy or tantalum, chosen against the mediumStandard
Flange material304 stainless steel on the forms describedStandard
Fill fluidNot stated in the materialInformation required
Seal and gasketNot stated in the materialInformation required
Mechanical
Process connectionFlanged DN50 or DN80; NPT 1/4 on the micro-differential formStandard
Flange standardNot stated in the material, and the flange drilling has to match the mating lineInformation required
Ingress protectionIP67, with IP65 versionsStandard
WeightNot stated in the materialInformation required
Environment
Ambient temperature-20 to 85 °C on the transmitter shownStandard
Medium temperatureNot stated in the material; it depends on the fill fluid and the sealInformation required
Hazardous areaAn explosion-proof form is listed, but the marking and certificate are not statedInformation required

Available models

Selection table
Model Configuration Key ranges Availability
Flanged, 4-20 mA with HART Two flanged pressure sides with a diaphragm between them; LCD and zero/span keys 0-1 kPa to 0-10 MPa; 0.075 to 0.5 class; DN50 or DN80 flange The general form for a line or a filter
Single flange with diaphragm seal One side flanged to the process, the other at atmosphere through a capillary Low spans for level and low-pressure duty Used where the medium would block or attack a plain diaphragm
Double flange with remote seals Two diaphragm seals on capillaries, for level in a closed or open tank Low spans; the two seals cancel the static head on the high side The form for a tank rather than a pipe
Micro-differential Low-range form for furnace and duct pressure, with 0-10 V or 4-20 mA output 0-3000 Pa and 0-30 kPa; NPT 1/4 connection For air and flue-gas pressure rather than liquid

Customization

  • Range, from a 0-1 kPa micro-differential span to 0-10 MPa
  • Accuracy class, from 0.5 through 0.2 and 0.1 to 0.075
  • Diaphragm material, from 316L stainless through Hastelloy to tantalum
  • Process connection, as a DN50 or DN80 flange or an NPT 1/4 port on the low-range form
  • Output, as 4-20 mA with HART, RS-485 or 0-10 V
  • Mounting, as a direct-mount transmitter or one on a capillary with a remote seal

Certification and compliance

Certification documents not yet supplied

Certifications are only published once a certificate copy can be produced, so this section is deliberately empty rather than populated with assumed approvals. Tell us which approvals your application requires and we will confirm what is available for this instrument.

Parameters still to be confirmed

The following are required for a complete specification but are not stated in the documentation supplied to us. They are listed rather than estimated:

  • The static pressure rating, which is separate from the differential range and is not stated
  • The temperature effect on the zero and span
  • Long-term stability and the recommended recalibration interval
  • The fill fluid, and the medium temperature it allows
  • The seal and gasket material
  • The flange standard and drilling, since the mating line decides it
  • The weight of each form
  • The explosion-proof marking and the certificate that covers it
  • The official model code, since the material does not give one
  • The response time
  • Warranty period and the terms that apply

Frequently asked questions

What has to be confirmed before a differential pressure transmitter can be quoted?

The two pressures and what the difference is used for, because a transmitter measuring flow across an orifice and one measuring level in a tank are specified differently. Then the range and the static pressure, which are separate figures: a low-range cell can be destroyed by a high line pressure even though the difference it measures is small. Then the diaphragm and seal material, the fill fluid if the medium is hot or viscous, the flange standard the line already uses, and the output and protocol the control system expects.

What is the difference between differential, gauge and absolute pressure?

A differential transmitter measures the difference between two pressures and has two process connections. A gauge transmitter measures one pressure against atmosphere and has one connection plus a vent. An absolute transmitter measures one pressure against a sealed vacuum reference. The three are different instruments rather than ranges on one, and the material covers the differential form only.

When is a double flange form used instead of a single flange?

When the measurement is level in a closed tank. The low side then carries the static head of the vessel, and a second diaphragm seal on a capillary puts the same head on the low side so the two cancel and the transmitter reads the level rather than the level plus the vessel pressure. On an open tank or a pipe, a single flange or a direct-mount form is the simpler answer.

Why does the low-range form read in pascals rather than megapascals?

Because the pressure difference across a filter, a fan or a furnace duct is small, and a cell built for megapascals cannot resolve it. The material offers 0-3000 Pa and 0-30 kPa spans with an NPT 1/4 connection and a 0-10 V or 4-20 mA output for that duty. The two ends of the range are different instruments, which is why they are listed as separate forms.

Related products

Other models in the same range

Three stainless steel pressure transmitters side by side, one with a plug connector, one with a plug and tubular body, and one with a circular connector and cable gland

MIK-P300 · Pressure Transmitters

Configurable Pressure Transmitter

Diffusion silicon pressure transmitters built in a family of housings, from a plain plug version to sanitary, high-temperature, explosion-proof and 4G wireless forms, with 4-20 mA, voltage or RS-485 Modbus output.

Pressure ranges
-100 kPa to 60 MPa across the series
Pressure types
Gauge, absolute and sealed gauge
Accuracy
0.2, 0.25 or 0.5 grade, by range and configuration
Output
4-20 mA two-wire; 0-5 V, 1-5 V or 0-10 V three-wire; RS-485 with Modbus
Stainless steel pressure transmitter with a plug connector on top, a hex body and a threaded pressure port

TFD-801 · Pressure Sensors

Diffusion Silicon Pressure Transmitter

Diffusion silicon pressure transmitters with a 304 stainless steel body, IP65 sealing and ranges from -100 kPa to 100 MPa, in two-wire 4-20 mA and three-wire voltage forms.

Pressure ranges
-100 kPa to 100 MPa across the series
Pressure types
Gauge, absolute and sealed gauge
Accuracy
0.2%FS on the stocked ranges; a 0.5% grade is listed for the series
Output
4-20 mA two-wire as standard; 0-5 V, 0-10 V or RS-485 to order
Stainless steel cylindrical probe with a black end cap carrying a central pressure port and a ring of four smaller ports around it, joined to a coiled length of black cable with two bare conductors emerging at the far end

XK-136P · Hydrostatic Level Transmitters

Submersible Level Transmitter

Submersible hydrostatic level transmitter for water tanks, sumps, reservoirs and pits, from 1 m to 10 m as standard, with a probe rated IP68.

Model
XK-136P
Type
Submersible hydrostatic level transmitter with a vented cable
Range
0 to 1 m, 0 to 3 m, 0 to 5 m and 0 to 10 m as standard, to 500 m to order
Accuracy
0.5 class, with 0.2 class to order

Request a quotation

Send the configuration you need and we will confirm availability, lead time and terms. Minimum order quantity is 1 pc.

Request for quotation

Request a quotation - Differential Pressure Transmitter

Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.

The more of this you can give us, the fewer exchanges are needed before we can quote.
No file chosen
Datasheet, drawing, BOM or photograph. One file, up to 10 MB (PDF, Office, image or ZIP).

By submitting this form you agree that we may contact you about this enquiry. We do not sell or share enquiry data. See our privacy policy.

Items held in stock are dispatched within 48 hours of order confirmation. Customized specifications are produced to order and typically ship within 2 to 10 days. Transit time then depends on the shipping method and destination.

Request a Quote WhatsApp