Electrical Test & Measurement · LCR Meters

Precision LCR Digital Bridge with Graphical Sweep

Precision bench LCR bridges covering 20 Hz to 300 kHz, 500 kHz or 1 MHz at 0.05% basic accuracy, with 1 mHz frequency resolution, a 7-inch colour display, 40-point list sweeps and graphical analysis.

HG7829A (3 models) ·

Key specifications

Test frequency
20 Hz to 300 kHz on HG7829A, to 500 kHz on HG7829B, to 1 MHz on HG7829C
Frequency resolution
1 mHz, continuously variable
Basic accuracy
0.05%
Test level
5 mV to 2 V as standard; 5 mV to 10 V on the enhanced version
Measurement time
9 ms fast, 67 ms medium, 187 ms slow
DC bias
−5 V to +5 V, continuous, 1% accuracy
Sweep
40-point list sweep and continuous graphical sweep of frequency, level or bias
Display
7-inch TFT colour LCD
Interfaces
RS232C, USBTMC, USBCDC and HANDLER; GPIB optional
Body
400 × 132 × 350 mm, 6.8 kg

A bridge that reports four digits at one frequency is a sorting tool. A bridge that can be swept across frequency, level and bias is an engineering instrument, and the difference shows up the first time a component behaves differently from its datasheet. This family is built for the second job.

Product overview

Three models share one chassis and one display, and differ only in how far the frequency reaches: 300 kHz, 500 kHz and 1 MHz, all starting at 20 Hz. Basic accuracy is 0.05% across the three, and the frequency is continuous with 1 mHz resolution rather than a list of fixed points.

The front panel carries a 7-inch colour display, a column of soft keys beside it, a rotary knob and a numeric keypad at the right, and the coaxial test terminals along the lower edge. The case is 400 mm wide, 132 mm high and 6.8 kg, which is a bench instrument rather than a portable one. The rear panel carries the device, external trigger, handler, serial and barcode connectors.

How the LCR bridge works

The instrument applies a sine wave at the chosen frequency and level, and measures the voltage across the component and the current through it. Both signals are resolved into an in-phase and a quadrature component; their ratio gives impedance and their angle gives phase. From that pair the instrument derives whichever parameter set the operator has chosen, in series or in parallel form.

Four terminals separate the current path from the voltage sense path, so the impedance of the leads and of the contact does not enter the result. Because the residual of the fixture itself still matters at the edges of the range, the instrument provides open and short calibration at spot frequencies, a full-frequency zero and a load calibration.

The sweep functions use the same engine repeatedly. A list sweep steps through up to 40 programmed points of frequency, level or bias; a graphical sweep runs continuously across a range and plots the result. The internal bias supply, adjustable between −5 V and +5 V, shifts the operating point of the component during either.

How to select the right LCR bridge

The first question is the highest frequency the parts are specified at. A part quoted at 100 kHz is comfortably inside all three models; one quoted at 400 kHz needs HG7829B or HG7829C; one quoted at 1 MHz needs HG7829C. Buying beyond that costs money and buys nothing.

The second is the test level. Five millivolts to 2 V covers most small-signal work, and the enhanced version extends that to 10 V for parts that need a larger drive. The level has to be settable at the value the datasheet uses, because a ceramic capacitor measured at a different level will not match its quoted capacitance.

The third is bias. The internal supply covers a few volts either way, which is enough for the level dependence of a ceramic or an electrolytic; a part that operates at a high voltage needs an external bias fixture, and the instrument has to be specified with that in mind.

The fourth is how results leave the instrument: ten-bin sorting with counting for a line, a handler port for a fixture, USB or serial for logging, and GPIB where an older test system expects it. The fifth is throughput: 9 ms per reading is fast enough for a handler, and the averaging setting from 1 to 255 readings trades that speed for stability.

Measurement limitations and selection considerations

The instrument measures small-signal parameters. It does not apply a high voltage, so it cannot reproduce the bias conditions of a capacitor that works at several hundred volts, and it cannot test insulation or leakage.

The connection is part of the measurement. At 1 MHz, a few centimetres of lead is a significant impedance, and the fixture has to hold the part at a repeatable geometry. Calibration removes a fixed residual but not a residual that changes when the leads are moved, which is why a proper fixture matters more at the top of the frequency range than at the bottom.

Averaging and speed interact with the part, not only with the instrument. A high-value capacitor or a large inductor takes time to settle after the signal is applied, and a 9 ms reading taken before it has settled will be different from a 187 ms reading of the same part. Where the reading is used as a limit, the timing setting belongs in the test procedure.

Finally, the sweep functions describe a component, not a specification. A curve that looks smooth is reassuring, but a pass or fail decision still needs a limit, and the limit has to come from the drawing rather than from the shape of the plot.

Features

  • Continuous frequency coverage from 20 Hz upwards with 1 mHz resolution, so a measurement can be taken at any point rather than at a fixed list of frequencies
  • Graphical sweep of frequency, level or bias, which shows how a component behaves across a range instead of at one condition
  • A 40-point list sweep for a fixed test program, so a bench can step through the same points on every part
  • Internal DC bias from −5 V to +5 V, which shifts the operating point of a capacitor without external equipment
  • Measurement time down to 9 ms, for a line that has to keep up with a handler
  • Ten-bin sorting with bin counting, for grading parts into tolerance bands rather than accepting or rejecting them
  • RS232C, USBTMC, USBCDC and HANDLER as standard, with GPIB as an option, so the instrument can be driven from a PC or a fixture
  • Internal storage of 100 setups and 500 files on a USB drive, with fuzzy, exact and barcode file search

Technical specifications

Every value below is taken from source documentation. Where a parameter is not stated in the available material it is marked as information required rather than estimated.

Measurement
ParametersZ, Y, C, L, X, B, R, G, D, Q, phase angle and DC resistanceStandard
Equivalent circuitSeries or parallelStandard
Basic accuracy0.05%Standard
Frequency range, HG7829A20 Hz to 300 kHzStandard
Frequency range, HG7829B20 Hz to 500 kHzStandard
Frequency range, HG7829C20 Hz to 1 MHzStandard
Frequency resolution1 mHzStandard
RangingAutomatic, hold or manual selectionStandard
Averaging1 to 255 readingsStandard
CalibrationOpen and short at spot frequencies, full-frequency zero, and load calibrationStandard
Display ranges
Impedance, resistance and reactance0.00001 Ω to 99.9999 MΩStandard
DC resistance0.00001 Ω to 99.9999 MΩStandard
Admittance, conductance and susceptance0.00001 µS to 99.9999 SStandard
Capacitance0.00001 pF to 9.9999 FStandard
Inductance0.00001 µH to 99.9999 kHStandard
Dissipation factor0.00001 to 9.99999Standard
Quality factor0.00001 to 99999.9Standard
Phase angle in degrees−179.999° to 179.999°Standard
Phase angle in radiansPrinted with the inductance range against it, which is a typesetting error in the sourceInformation required
Deviation−999.999% to 999.999%Standard
Signal and timing
Test level, standard5 mV to 2 VStandard
Test level, enhanced version5 mV to 10 VStandard
Automatic level range5 mV to 1 V, 5% accuracy, 1 mV resolutionStandard
Output impedance10 Ω with constant current, 25 Ω, 50 Ω or 100 ΩStandard
Internal DC bias−5 V to +5 V continuous, 1% accuracyStandard
Measurement time9 ms fast, 67 ms medium, 187 ms slowStandard
Delay0 to 60 s in 1 ms stepsStandard
TriggerInternal, manual, external or busStandard
Sweep, sorting and storage
List sweep40 points of frequency, level, bias voltage or bias currentStandard
Graphical sweepFrequency, level, bias voltage or bias current, with graphical analysisStandard
ComparatorTen bins with bin countingStandard
Internal memory100 setupsStandard
USB memory500 files on a USB driveStandard
File searchFuzzy, exact and barcode searchStandard
Interface, power and mechanical
Standard interfacesRS232C, USBTMC, USBCDC and HANDLERStandard
Optional interfaceGPIBOptional
Rear panel connectorsDevice, external trigger, HANDLER, RS-232C and barcodeStandard
Mains supplyNot stated in the materialInformation required
Dimensions400 mm × 132 mm × 350 mm, width by height by depthStandard
Weight6.8 kgStandard
Supplied fixtureA test fixture is listed for this familyStandard

Available models

Selection table
Model Configuration Key ranges Availability
HG7829A Precision LCR bridge with a 7-inch colour display 20 Hz to 300 kHz; 5 mV to 2 V as standard; 0.05% accuracy; 9 ms fast measurement The base model of the family
HG7829B Precision LCR bridge with a 7-inch colour display 20 Hz to 500 kHz; otherwise as HG7829A Extends the frequency range for parts specified above 300 kHz
HG7829C Precision LCR bridge with a 7-inch colour display 20 Hz to 1 MHz; otherwise as HG7829A The widest frequency range in the family

Customization

  • GPIB interface, fitted as an option
  • Test fixtures for a particular package or a particular board
  • An enhanced signal level of 5 mV to 10 V instead of the standard 5 mV to 2 V

Certification and compliance

Certification documents not yet supplied

Certifications are only published once a certificate copy can be produced, so this section is deliberately empty rather than populated with assumed approvals. Tell us which approvals your application requires and we will confirm what is available for this instrument.

Parameters still to be confirmed

The following are required for a complete specification but are not stated in the documentation supplied to us. They are listed rather than estimated:

  • The phase angle range in radians, which the source prints as an inductance range and which is almost certainly a typesetting error
  • The mains input voltage, frequency and power consumption, which the material does not give
  • Whether HG7829B and HG7829C are supplied with the same standard level range as HG7829A or with the enhanced level
  • The warm-up time and the calibration conditions under which the stated 0.05% applies
  • The measurement time of the medium setting, whose unit is missing in the source and has been read as milliseconds
  • Whether the 7-inch TFT display or the five-digit LED display described elsewhere in the same material is correct
  • Whether a calibration certificate is supplied and to which standard
  • Warranty period and its terms
  • The model designation of the supplied test fixture, which the material gives only for the wider family

Frequently asked questions

What does the graphical sweep add over a single reading?

It shows the component rather than a point on it. A capacitor whose capacitance falls with frequency, or an inductor that approaches self-resonance, looks acceptable at one test frequency and clearly out of specification across a band. Sweeping frequency, level or bias and plotting the result makes that visible in one pass, and the 40-point list sweep gives a repeatable version of the same check for production.

How much does the internal DC bias cover?

Minus 5 V to plus 5 V, continuously adjustable, with 1% accuracy. That is enough to check how a ceramic capacitor behaves with a few volts across it, which is where the larger capacitance changes appear. It is not a substitute for a high-voltage bias fixture, so a part that operates at a few hundred volts still needs external bias equipment.

What has to be confirmed before a quotation?

The highest frequency at which the parts are specified, since that decides between the three models; the test level and whether a bias is needed; the tolerance bands and how many bins they occupy; and whether the instrument will be driven over GPIB, USB or the handler port. The fixture for the package should be settled at the same time.

Related products

Other models in the same range

Bench LCR bridge in a grey case, with a five-digit LED display showing a primary and a secondary reading, four coaxial test terminals across the lower centre of the panel, a column of range and function keys at the right and the power switch at the left

HG2810B (6 models) · LCR Meters

Bench LCR Digital Bridge

Bench LCR bridges covering fixed-frequency and wide-band models, with 0.10% or 0.05% basic accuracy, five-terminal connections, bin sorting and optional RS232 and HANDLER interfaces for incoming inspection and production sorting.

Test frequencies
100 Hz, 120 Hz, 1 kHz and 10 kHz on the general models; up to 100 kHz on HG2817 and HG2817B; 8 points to 100 kHz on HG2817D; 37 points from 50 Hz to 200 kHz on HG2817A
Basic accuracy
0.10% on the general models; 0.05% on HG2816A and HG2817A
Test level
0.3 V on HG2810B; 0.1 V, 0.3 V or 1.0 V on most other models; 10 mV to 2.00 V in 10 mV steps on HG2816A and HG2817A
Display ranges
L 0.01 µH to 99999 H and C 0.01 pF to 99999 µF on the general models, with wider ranges on the LCD models
Benchtop inductance meter seen from the front, with a blue backlit LCD at the left showing an inductance value and a quality factor, a numeric keypad and arrow keys at the right, and four BNC terminals with a ground terminal along the lower front edge

HG2776A (2 models) · LCR Meters

Precision Inductance Meter with Wide Frequency Coverage

Two bench inductance meters, one covering 100 Hz to 200 kHz in 37 points at 0.05% accuracy and one covering four points to 10 kHz at 0.1%, both with four-terminal connection and multi-parameter display.

Test frequency
100 Hz to 200 kHz in 37 points on HG2776A; 100 Hz to 10 kHz in four points on HG2775A
Basic accuracy
0.05% on HG2776A; 0.1% on HG2775A
Test level
10 mV to 2.00 V in 10 mV steps on HG2776A; 0.1 V, 0.3 V or 1 V on HG2775A
Inductance range
0.01 nH to 9999.99 H

Request a quotation for the HG7829A

Send the configuration you need and we will confirm availability, lead time and terms. Minimum order quantity is 1 pc.

Request for quotation

Request a quotation - HG7829A

Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.

The more of this you can give us, the fewer exchanges are needed before we can quote.
No file chosen
Datasheet, drawing, BOM or photograph. One file, up to 10 MB (PDF, Office, image or ZIP).

By submitting this form you agree that we may contact you about this enquiry. We do not sell or share enquiry data. See our privacy policy.

Items held in stock are dispatched within 48 hours of order confirmation. Customized specifications are produced to order and typically ship within 2 to 10 days. Transit time then depends on the shipping method and destination.

Request a Quote WhatsApp