- Application
- Pressure testing of PPR water pipe, mains pipe, underfloor heating loops and plumbing installations
- Gauge fitted
- 25 MPa on the standard version; a 7 MPa oil gauge on the upgraded version; 40 or 60 MPa on the enlarged version
- Tank
- 18 litres, iron, 1.35 mm wall, sprayed finish, 300 × 200 × 90 mm
- Pump body
- Aluminium; thickened on the upgraded and enlarged versions
- Ram diameter
- 35 mm standard; 45 mm on the upgraded and enlarged versions
- Flow
- 35 cm³ per stroke
- Lever length
- 29 cm standard; 38 cm upgraded; 33 cm or 38 cm for the enlarged version — the material states both
- Connection
- Four fen (1/2) threads throughout
- Hose
- 1.0 m or 1.5 m reinforced hose, stated as rated to 32 MPa
- Typical test pressure held
- 0.8 to 1 MPa on domestic pipework, held for 2 to 4 hours
A manual pressure test pump exists to answer one question about a pipe installation: does it hold water under pressure. It is carried to a site, filled from its own tank, connected to the run, and worked by hand until the gauge reaches the test figure. The run is then left closed and watched, and what happens to the reading over the next few hours is the result.
The pump on this page is built around an 18 litre iron tank with an aluminium pump body on top, a lever, a brass check valve, a relief valve and a reinforced hose. Three versions are offered with different gauges and rams - 25 MPa standard, 7 MPa oil gauge upgraded, and 40 or 60 MPa enlarged - and a third-generation version carries a 70 kg oil gauge for finer reading.
How a hydrostatic test pump works
The lever drives a piston in a small cylinder. On the upstroke water is drawn from the tank through a strainer and a check valve; on the downstroke it is pushed into the hose and so into the closed pipe run. Because the run is closed and water is very nearly incompressible, each stroke raises the pressure by a small amount, and the pressure stays where it is put rather than relaxing back. That is why a hand pump of this size can hold a large pipe run at pressure: it is not storing energy in the water, it is filling a volume that cannot get any smaller.
The check valve is what turns a pump into a test instrument. With its shut-off closed, the water can pass from the pump into the run but not back, so the lever can be left alone and the gauge watched. The relief valve provides the other half of the arrangement: a controlled way to release the pressure before anything is disconnected, which is not optional on a closed hydraulic system.
The gauge is the only measuring element in the chain, and its condition decides what the test is worth. Vibration-resistant gauges are fitted, which steadies the needle while the lever is being worked and makes a small fall in pressure visible against a background of flutter.
How to select the right pump
Choose the version from the test pressure and the pipe volume. The gauge range has to sit above the test figure with enough margin to read it, so a 25 MPa gauge covers domestic and general plumbing work comfortably, while a system tested at a higher figure needs the enlarged version and its 40 or 60 MPa gauge. The ram diameter and lever length then decide how quickly the run is filled: the upgraded and enlarged versions carry a 45 mm ram against the standard version’s 35 mm, and a longer lever moves it more easily, which matters on a large run where the initial filling takes many strokes.
Then decide the hose length from where the pump will actually stand. A 1.0 m hose is enough when the test point is beside the pump, and 1.5 m versions are offered for the cases where it is not. The hose is stated as rated to 32 MPa, so on the standard version it is not the limiting item, but on a higher-pressure version the assembly can only be taken to the lowest rating in the chain, and the material does not state a maximum for the pump body and tank.
Then check the connection. Everything in the assembly is four fen (1/2), which matches the fittings used in the pipe systems this pump is intended for, and the relief port has to line up with the drain hole in the tank when the body is bolted down, so that a release does not put water over whoever is operating it.
Carrying out a pressure test
The documented procedure is short and worth following in order. Fix the body to the tank with the four screws, with the relief port over the drain hole. Fit the outlet hose to the body with its gasket, or with PTFE tape, since this is one of the joints that leaks if it is assembled dry. Connect the other end of the hose to the pipe, again taped. Fill the pipe and vent the air out of it, then close the relief valve and fill the tank with clean water. Work the lever until the gauge reaches the test figure, then stop.
For domestic work the test pressure is around 0.8 to 1 MPa and the hold is two to four hours. If the gauge holds, the run is sound; if it falls, the pipe or a joint is leaking. The material notes plainly that testing above the figure the system calls for shortens the life of the pipe and can damage it, so the test figure comes from the specification rather than from what the pump can reach.
Measurement limitations and selection considerations
This is a test pump, not a pressure source for calibration. It generates a pressure and holds it, but it does not measure it to a stated accuracy, and the gauge fitted is a process gauge rather than a reference. Checking an instrument against a known pressure is a different job with a different instrument, and a calibrator is the one for it.
The pump is also limited to water and to pipework duties. It is not built for a medium that would attack the brass check valve or the aluminium body, and it is not a means of testing a pressure vessel to a code rather than a pipe run to an installation specification. Where a test has to be recorded against a named standard, the acceptance criterion, the hold time and the permitted drop come from that standard, and the material documents none of those for this pump.
Two smaller points are worth knowing before the first use. The unit is supplied with spare seals, O-rings and washers because the joints are the parts that wear, and the fault chart in the material attributes almost every symptom to a seal, a blockage or a loose connection rather than to the pump itself. And the tank is filled with clean water by hand, which sets a practical limit on how large a run can be filled before a refill is needed.
Ordering
A quotation needs the system to be tested and the test pressure required, which fixes the version and the gauge range. Then the connection at the test point, the hose length that reaches it from where the pump will stand, and whether a spare set of seals and washers is wanted. If the test is to a specification that names a hold time and a permitted pressure drop, state which specification, since that fixes the acceptance criterion rather than the pump.
Every value below is taken from source documentation. Where a parameter is not stated in the available material it is marked as information required rather than estimated.