This page holds a place in the catalogue structure. The specification shows the indicative figures published for this instrument class so the layout can be reviewed; it does not describe a supplied product. Confirmed values, brand and documentation are issued with the quotation for the model actually sourced.
Data Acquisition & Monitoring · Industrial Data Loggers
Industrial Data Logger
Standalone multi-channel data logger recording temperature, voltage and current inputs at programmable intervals, with internal memory and network export.
DL-16 · DL range · Sourced to order
Key specifications
- Channels
- 16 universal inputs
- Input types
- Thermocouple, RTD, 4-20 mA, 0-10 V
- Sampling interval
- 1 s to 24 h
- Internal memory
- 8 GB, expandable by SD card
- Communication
- Ethernet, RS485, USB
- Protection
- IP65 enclosure
A data logger answers a question that a control system does not: what happened over weeks or months, at a resolution fine enough to show the trend. Because it runs independently of the control system it also survives it, which is why loggers are the usual instrument for proving a process was within specification after the fact.
Channel count and isolation decide most applications. An unisolated logger is cheaper and perfectly adequate for a set of thermocouples referenced to the same ground, but the moment a channel connects to a different circuit, or a thermocouple touches a live surface, isolation stops being optional.
Features
- Universal inputs accepting thermocouples, RTDs, current and voltage on any channel
- Independent recording that continues when the control system does not
- Alarm-triggered recording to capture an event without filling the memory
- Web interface for configuration and data download over the network
- Battery backup preserving the clock and configuration through a power failure
Technical specifications
Every value below is taken from source documentation. Where a parameter is not stated in the available material it is marked as information required rather than estimated.
| Channel count | 16 universal, expandableMade to order |
|---|---|
| Thermocouple | Types K, J, T, E, N, R, S, BStandard |
| RTD | PT100, PT1000, two or three wireStandard |
| Current | 4-20 mA with 24 V loop supplyStandard |
| Voltage | 0-10 V, ±10 V, ±100 mVStandard |
| Isolation | Channel to channel, 500 VOptional |
| Sampling interval | 1 s to 24 h per channelStandard |
|---|---|
| Internal memory | 8 GBStandard |
| Removable storage | SD cardStandard |
| Recording modes | Continuous, trigger, alarmStandard |
| Accuracy | ±0.1% of spanStandard |
| Ethernet | 10/100 Mbps, web interface and FTPStandard |
|---|---|
| Serial | RS485 Modbus RTUStandard |
| USB | Configuration and downloadStandard |
| Power supply | 24 V DC or mains adapterStandard |
| Enclosure rating | IP65Standard |
Available models
| Model | Configuration | Key ranges | Availability |
|---|---|---|---|
| DL-16U | 16 universal channels | TC, RTD, mA, V | |
| DL-32U | 32 universal channels | TC, RTD, mA, V |
Customization
- Channel complement and isolation to the measurement task
- Sensor wiring and termination supplied as a pre-wired assembly
- Reporting templates and export format configured for the quality system
Certification and compliance
Certification documents not yet supplied
Certifications are only published once a certificate copy can be produced, so this section is deliberately empty rather than populated with assumed approvals. Tell us which approvals your application requires and we will confirm what is available for this instrument.
Parameters still to be confirmed
The following are required for a complete specification but are not stated in the documentation supplied to us. They are listed rather than estimated:
- Certification list (CE / RoHS / EMC) and availability of certificate copies
- Accuracy reference standard defining the stated accuracy class
- Operating temperature range
- Ingress protection rating of the supplied variant
- Warranty period and the terms that apply
- English-language datasheet and manual in PDF form
- Wiring diagram and terminal definitions
- Packaging dimensions and gross weight for freight calculation
Frequently asked questions
How long can it record?
It depends on channel count and interval, but the arithmetic is simple: 16 channels at one minute intervals fills an 8 GB card in a matter of years. The constraint in practice is usually how often someone downloads the data.
Do I need isolated inputs?
If every channel shares the same reference and none touches a live conductor, no. If channels come from different circuits, or a thermocouple is welded to a live surface, isolation prevents a ground loop that will corrupt every reading on the instrument.
Request a quotation for the DL-16
Send the configuration you need and we will confirm availability, lead time and terms. Minimum order quantity is 1 pc.
Request for quotation
Request a quotation - DL-16
Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.