Reference listing

This page holds a place in the catalogue structure. The specification shows the indicative figures published for this instrument class so the layout can be reviewed; it does not describe a supplied product. Confirmed values, brand and documentation are issued with the quotation for the model actually sourced.

Data Acquisition & Monitoring · Industrial Data Loggers

Industrial Data Logger

Standalone multi-channel data logger recording temperature, voltage and current inputs at programmable intervals, with internal memory and network export.

DL-16 · DL range · Sourced to order

Key specifications

Channels
16 universal inputs
Input types
Thermocouple, RTD, 4-20 mA, 0-10 V
Sampling interval
1 s to 24 h
Internal memory
8 GB, expandable by SD card
Communication
Ethernet, RS485, USB
Protection
IP65 enclosure

A data logger answers a question that a control system does not: what happened over weeks or months, at a resolution fine enough to show the trend. Because it runs independently of the control system it also survives it, which is why loggers are the usual instrument for proving a process was within specification after the fact.

Channel count and isolation decide most applications. An unisolated logger is cheaper and perfectly adequate for a set of thermocouples referenced to the same ground, but the moment a channel connects to a different circuit, or a thermocouple touches a live surface, isolation stops being optional.

Features

  • Universal inputs accepting thermocouples, RTDs, current and voltage on any channel
  • Independent recording that continues when the control system does not
  • Alarm-triggered recording to capture an event without filling the memory
  • Web interface for configuration and data download over the network
  • Battery backup preserving the clock and configuration through a power failure

Technical specifications

Every value below is taken from source documentation. Where a parameter is not stated in the available material it is marked as information required rather than estimated.

Inputs
Channel count16 universal, expandableMade to order
ThermocoupleTypes K, J, T, E, N, R, S, BStandard
RTDPT100, PT1000, two or three wireStandard
Current4-20 mA with 24 V loop supplyStandard
Voltage0-10 V, ±10 V, ±100 mVStandard
IsolationChannel to channel, 500 VOptional
Recording
Sampling interval1 s to 24 h per channelStandard
Internal memory8 GBStandard
Removable storageSD cardStandard
Recording modesContinuous, trigger, alarmStandard
Accuracy±0.1% of spanStandard
Communication and general
Ethernet10/100 Mbps, web interface and FTPStandard
SerialRS485 Modbus RTUStandard
USBConfiguration and downloadStandard
Power supply24 V DC or mains adapterStandard
Enclosure ratingIP65Standard

Available models

Selection table
Model Configuration Key ranges Availability
DL-16U 16 universal channels TC, RTD, mA, V
DL-32U 32 universal channels TC, RTD, mA, V

Customization

  • Channel complement and isolation to the measurement task
  • Sensor wiring and termination supplied as a pre-wired assembly
  • Reporting templates and export format configured for the quality system

Certification and compliance

Certification documents not yet supplied

Certifications are only published once a certificate copy can be produced, so this section is deliberately empty rather than populated with assumed approvals. Tell us which approvals your application requires and we will confirm what is available for this instrument.

Parameters still to be confirmed

The following are required for a complete specification but are not stated in the documentation supplied to us. They are listed rather than estimated:

  • Certification list (CE / RoHS / EMC) and availability of certificate copies
  • Accuracy reference standard defining the stated accuracy class
  • Operating temperature range
  • Ingress protection rating of the supplied variant
  • Warranty period and the terms that apply
  • English-language datasheet and manual in PDF form
  • Wiring diagram and terminal definitions
  • Packaging dimensions and gross weight for freight calculation

Frequently asked questions

How long can it record?

It depends on channel count and interval, but the arithmetic is simple: 16 channels at one minute intervals fills an 8 GB card in a matter of years. The constraint in practice is usually how often someone downloads the data.

Do I need isolated inputs?

If every channel shares the same reference and none touches a live conductor, no. If channels come from different circuits, or a thermocouple is welded to a live surface, isolation prevents a ground loop that will corrupt every reading on the instrument.

Request a quotation for the DL-16

Send the configuration you need and we will confirm availability, lead time and terms. Minimum order quantity is 1 pc.

Request for quotation

Request a quotation - DL-16

Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.

The more of this you can give us, the fewer exchanges are needed before we can quote.
No file chosen
Datasheet, drawing, BOM or photograph. One file, up to 10 MB (PDF, Office, image or ZIP).

By submitting this form you agree that we may contact you about this enquiry. We do not sell or share enquiry data. See our privacy policy.

Items held in stock are dispatched within 48 hours of order confirmation. Customized specifications are produced to order and typically ship within 2 to 10 days. Transit time then depends on the shipping method and destination.

Request a Quote WhatsApp