This page holds a place in the catalogue structure. The specification shows the indicative figures published for this instrument class so the layout can be reviewed; it does not describe a supplied product. Confirmed values, brand and documentation are issued with the quotation for the model actually sourced.

Gas Detection & Safety Instruments · Portable Gas Detectors

Portable Multi-Gas Detector

Four-gas personal detector with a pumped or diffusion inlet, audible and visual alarms, and a datalog for confined space entry and plant rounds.

MGD-4 · MGD range · Sourced to order

Key specifications

Sensors
LEL, O₂, CO, H₂S
Sampling
Diffusion or integral pump
Alarms
Audible 95 dB, visual, vibration
Protection
IP66, drop tested 2 m
Battery
Rechargeable, 12 h runtime
Datalog
Continuous with time stamps

A personal gas detector is a life-safety device, and the specification that matters is not the sensor resolution but the confidence that it will alarm. That depends on bump testing and calibration discipline far more than on the instrument.

The two failure modes to design against are a sensor that has drifted out of calibration and a detector that is switched off. Pumped sampling extends the instrument to confined spaces and remote points where diffusion alone will not reach, while a datalog provides the record that a permit-to-work system requires.

Features

  • Four gas channels with audible, visual and vibration alarms on every alarm level
  • Integral pump option extending measurement to confined spaces and remote points
  • Continuous datalog with time stamps for permit-to-work records
  • Two, three or four channel configurations as required by the task
  • Bump test and calibration station compatible

Technical specifications

Every value below is taken from source documentation. Where a parameter is not stated in the available material it is marked as information required rather than estimated.

Sensing
Combustible gas0-100% LEL, catalytic beadStandard
Oxygen0-30% vol, electrochemicalStandard
Carbon monoxide0-500 ppm, electrochemicalStandard
Hydrogen sulphide0-100 ppm, electrochemicalStandard
Alternative sensorsCO₂ infrared, VOC PIDOptional
Alarms and housing
Audible alarm95 dB at 30 cmStandard
Visual alarmRed and blue flashing LEDsStandard
Vibration alarmIntegralStandard
Enclosure ratingIP66Standard
Drop resistance2 m onto concreteStandard
General
SamplingDiffusion or integral pump with 10 m hoseMade to order
BatteryRechargeable lithium, 12 h typicalStandard
DatalogContinuous, 6 months at one minute intervalsStandard
InterfaceUSB or infrared exportStandard
Operating temperature-20 to 50 °CStandard

Available models

Selection table
Model Configuration Key ranges Availability
MGD-4D Four gas, diffusion LEL, O₂, CO, H₂S
MGD-4P Four gas, integral pump LEL, O₂, CO, H₂S

Customization

  • Sensor complement matched to the hazards actually present
  • Alternative sensors for carbon dioxide or volatile organic compounds
  • Docking and bump test station supplied for fleet management

Certification and compliance

Certification documents not yet supplied

Certifications are only published once a certificate copy can be produced, so this section is deliberately empty rather than populated with assumed approvals. Tell us which approvals your application requires and we will confirm what is available for this instrument.

Parameters still to be confirmed

The following are required for a complete specification but are not stated in the documentation supplied to us. They are listed rather than estimated:

  • Certification list (CE / RoHS / EMC) and availability of certificate copies
  • Accuracy reference standard defining the stated accuracy class
  • Operating temperature range
  • Ingress protection rating of the supplied variant
  • Warranty period and the terms that apply
  • English-language datasheet and manual in PDF form
  • Wiring diagram and terminal definitions
  • Packaging dimensions and gross weight for freight calculation

Frequently asked questions

What is a bump test and how often is it needed?

A bump test exposes the sensor to a known concentration briefly, to confirm it responds and alarms. It is not a calibration. Most permit-to-work systems require it before each shift or each entry, whichever is less frequent.

Diffusion or pumped?

Diffusion is adequate for personal protection where the wearer is in the atmosphere being monitored. A pump is required for confined space entry, where the atmosphere has to be sampled from several depths before the space is entered.

Request a quotation for the MGD-4

Send the configuration you need and we will confirm availability, lead time and terms. Minimum order quantity is 1 pc.

Request for quotation

Request a quotation - MGD-4

Send the technical detail and we will confirm availability, lead time and terms. In-stock items ship within 48 hours; customized specifications typically take 2-10 days. Minimum order quantity is 1 pc.

The more of this you can give us, the fewer exchanges are needed before we can quote.
No file chosen
Datasheet, drawing, BOM or photograph. One file, up to 10 MB (PDF, Office, image or ZIP).

By submitting this form you agree that we may contact you about this enquiry. We do not sell or share enquiry data. See our privacy policy.

Items held in stock are dispatched within 48 hours of order confirmation. Customized specifications are produced to order and typically ship within 2 to 10 days. Transit time then depends on the shipping method and destination.

Request a Quote WhatsApp